Page 3- Manual FA01722-EN - 12/2021 - © CAME S.p.A. - The contents of this manual may be changed at any time and without notice. - Translation of the original instructions
GENERAL PRECAUTIONS FOR INSTALLERS
Important safety instructions.
Please follow all of these instructions. Improper installation may cause serious bodily harm.
Before continuing, please also read the general precautions for users.
Only use this product for its intended purpose. Any other use is hazardous. • The manufacturer cannot be held liable for
any damage caused by improper, unreasonable or erroneous use. • This product is defined by the Machinery Directive
(2006/42/EC) as partly completed machinery. • Partly completed machinery means an assembly which is almost
machinery but which cannot in itself perform a specific application. • Partly completed machinery is only intended to be
incorporated into or assembled with other machinery or other partly completed machinery or equipment thereby forming
machinery to which the Machinery Directive (2006/42/EC) applies. • The final installation must comply with the Machinery
Directive (2006/42/EC) and the European reference standards in force. • The manufacturer declines any liability for using
non-original products, which would also void the warranty. • All operations indicated in this manual must be carried out
exclusively by skilled and qualified personnel and in full compliance with the regulations in force. • The device must be
installed, wired, connected and tested according to good professional practice, in compliance with the standards and laws
in force. • All the components (e.g. actuators, photocells and sensitive edges) needed for the final installation to comply
with the Machinery Directive (2006/42/EC) and with the reference harmonised technical standards are specified in the
general CAME product catalogue or on the website www.came.com. • Make sure the mains power supply is disconnected
during all installation procedures. • Check that the temperature ranges given are suitable for the installation site. • The
appliance must be powered with a voltage corresponding to the value shown on the rating plate. Power must be supplied
through a very low safety voltage system. • When excavating to lay the foundation box, ensure there is sufficient drainage
to prevent water from stagnating inside it. • Make sure that no jets of water can wet the foundation box where it is
installed, either directly (sprinklers, pressure washers, etc.) or indirectly (taps, trench drains). • Make sure you have set up
a suitable dual-pole cut-off device along the power supply that is compliant with the installation rules. It should completely
cut off the power supply according to category III surcharge conditions. • Demarcate the entire site properly to prevent
unauthorised personnel from entering, especially minors. • In case of manual handling, have one person for every 20 kg
that needs hoisting; for non-manual handling, use proper hoisting equipment in safe conditions. • Use suitable protection
to prevent any mechanical hazards due to persons loitering within the operating range of the operator. • The electrical
cables must pass through special pipes, ducts and cable glands in order to guarantee adequate protection against
mechanical damage. • Make sure that the moving mechanical parts are suitably far away from the wiring. • The electrical
cables must not touch any parts that may overheat during use (such as the motor and transformer). • Before installation,
check that the guided part is in good mechanical condition, and that it opens and closes correctly. • The product cannot be
used to automate any guided part that includes a pedestrian gate, unless it can only be enabled when the pedestrian gate
is secured. • Make sure that nobody can become trapped between the guided and fixed parts, when the guided part is set
in motion. • All fixed controls must be clearly visible after installation, in a position that allows the guided part to be directly
visible, but far away from moving parts. In the case of a hold-to-run control, this must be installed at a minimum height
of 1.5 m from the ground and must not be accessible to the public. • Where operated with a hold-to-run control, install a
STOP button to disconnect the main power supply to the operator, to block movement of the guided part. • If not already
present, apply a permanent tag that describes how to use the manual release mechanism close to it.