manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. CAME
  6. •
  7. Keypad
  8. •
  9. CAME MTMNA Owner's manual

CAME MTMNA Owner's manual

Keypad module for access control
MTMNA
PROGRAMMING MANUAL
EN
En
g
l
i
s
h
FA01407-EN
SW2
MASTER
VAS/101
Page 2- Manual FA01031-IT - 08/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
Page 2- Manual FA01407-EN - 10/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructionsPage 2- Manual FA01407-EN - 10/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Original instructions
Use codes to access the programming functions. During a programming functions, the red light strip flashes every
two seconds for an amount of times that corresponds the first digit of the programming code (when changing the
password, the code is 10, and the light alert will flash once).
At the end of each correct procedure, a long beep will act as confirmation, while a wrong procedure will cause
three short beeps to sound o.
To enter the programming, type the Master code (the de-
fault one is 0000) and press . The lower light strip
on the keypad turns red to confirm that you have entered
the programming mode.
General Precautions
• WARNING! Important people-safety instructions: READ CAREFULLY!
• Installing, programming, commissioning and maintenance must only be done by qualified, expert sta and in
full compliance with the applicable law.
• Wear antistatic protective clothing when working on the control board.
• Keep these precautions.
• Always cut o the mains power when doing cleaning and maintenance jobs.
• This product must only be used for its specifically intended purpose. Any other use is dangerous.
• The manufacturer declines all liability for any damage as a result of improper, incorrect or unreasonable use.
• This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
1 - This device may not cause harmful interference.
2 - This device must accept any interference received, including interference that may cause undesired operation.
RESTORE FACTORY DEFAULT
To restore the MTMNA module to its factory settings, disconnect the power supply and then power up the module
again. Enter the code within 1 minute.
This phase is characterized by the button-lighting flashing: the device, is in any case, working.
PROGRAMMING IN MASTER MODE
The device requires the numerical access codes to be associated to users. This enables the subsequent removal
of all of the numerical codes associated to a user for each relay-switch.
USER ID: A user is characterized by a an ID included between 1 and 999.
USER CODE: An alphanumerical access code that is between four and eight digits long and which can activate
either one or both relays
You can associate several codes to each user. The number codes must all be dierent.
Up to 3,500 number codes can be assigned.
Page 3- Manual FA01031-IT - 08/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
Page 3- Manual FA01407-EN - 10/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructionsPage 3- Manual FA01407-EN - 10/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Original instructions
Code for
programming
device
Function Sequence
Changing Master code + new Master code +
Deleting the codes list + + +
Associating user ID and user code
to relay-switch 1
+ + user ID (max 4 digits) + +
user code (from 4 to 8 digits) +
Removing all user codes
associated to relay-switch 1 + + user ID (max 4 digits)+
Associating user ID and user code
to relay-switch 2
+ + user ID (max 4 digits)+ +
user code (from 4 to 8 digits) +
Removing all user codes
associated to the user ID of re-
lay-switch 2
+ + user ID (max 4 digits) +
Setting the relay-switch 1 time
(default 1 s - max 3,600 s) + 'time in seconds' +
Setting the relay-switch 2 time
(default 1 s - max 3,600 s) + 'time in seconds' +
Setting the LED color
WHITE: + +
BLUE (default): + +
Setting the brightness of
the LEDs
OFF: + +
25%: + +
50% (default): + +
75%: + +
100%: + +
Setting the tone
OFF: + +
ON (default): + +
To exit programming, press the button . The red light alert will turn o.
CAME S.p.A.
Via Martiri Della Libertà, 15
31030 Dosson di Casier - Treviso - Italy
tel. (+39) 0422 4940 - fax. (+39) 0422 4941
SW2
SLAVE
VA/08 - ETI/XIP
ETI/XIP APP
DVC/IP
MTMIP
Page 4- Manual FA01031-IT - 08/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
Page 4- Manual FA01407-EN - 10/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructionsPage 4- Manual FA01407-EN - 10/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Original instructions
USING THE DEVICE
There are two operating modes:
1- enter the access code (4-8 digits) and press button ;
2- press button , enter the access code and again press button .
In both modes, a valid code will cause a confirmation beep to sound and a green light to light up.
A wrong code will cause 3 quick beeps and a red light to light up.
The sending of the device's ID code happens when
you type the code .
This product complies with the law.
Decommissioning and disposal. Dispose of the packaging and the device at the end of its life cycle responsibly, in compliance with the laws in force in
the country where the product is used. The recyclable components are marked with a symbol and the material's ID marker.
THE DATA PRESENTED IN THIS MANUAL MAY BE SUBJECT TO CHANGE, AT ANY TIME, AND WITHOUT NOTICE.
MEASUREMENTS, UNLESS OTHERWISE STATED, ARE IN MILLIMETERS.
PROGRAMMING IN SLAVE MODE
In SLAVE configuration mode, the device is connected to the CAN BUS and the programming is executed by the
PCSXIP software.

Other CAME Keypad manuals

CAME S6000 User manual

CAME

CAME S6000 User manual

CAME S9000 User manual

CAME

CAME S9000 User manual

CAME BPT MTMKB Assembly instructions

CAME

CAME BPT MTMKB Assembly instructions

CAME BPT MTM Assembly instructions

CAME

CAME BPT MTM Assembly instructions

CAME TOP 864NA User manual

CAME

CAME TOP 864NA User manual

CAME PTDC70 User manual

CAME

CAME PTDC70 User manual

CAME STDCSNWL User manual

CAME

CAME STDCSNWL User manual

CAME SELT1W4G User manual

CAME

CAME SELT1W4G User manual

CAME PXKTN01 User manual

CAME

CAME PXKTN01 User manual

CAME PXWKTN01 User manual

CAME

CAME PXWKTN01 User manual

Popular Keypad manuals by other brands

Aritech ATS1136 Installation sheet

Aritech

Aritech ATS1136 Installation sheet

Speco SG-WR150 instruction manual

Speco

Speco SG-WR150 instruction manual

Satel INT-TSG2 Quick user manual

Satel

Satel INT-TSG2 Quick user manual

LEGRAND 0 767 17 manual

LEGRAND

LEGRAND 0 767 17 manual

DSC Power PK55 433 Series installation instructions

DSC

DSC Power PK55 433 Series installation instructions

Digichain WP6K user manual

Digichain

Digichain WP6K user manual

Targus WKP-100 user manual

Targus

Targus WKP-100 user manual

United Technologies Interlogix TVK 800 user manual

United Technologies

United Technologies Interlogix TVK 800 user manual

Gemini GEM-DXK2 operating guide

Gemini

Gemini GEM-DXK2 operating guide

Digiplex DGP-641ACC Programming guide

Digiplex

Digiplex DGP-641ACC Programming guide

Eaton DX-KEY-LED instruction manual

Eaton

Eaton DX-KEY-LED instruction manual

Paxton ins-20800-US manual

Paxton

Paxton ins-20800-US manual

XPR Access LCS-RS user manual

XPR Access

XPR Access LCS-RS user manual

Speed Link SL-6433 user guide

Speed Link

Speed Link SL-6433 user guide

Security Command SC Series user guide

Security Command

Security Command SC Series user guide

Black Box SC-Keypad manual

Black Box

Black Box SC-Keypad manual

Paradox Grafica User quick reference guide

Paradox

Paradox Grafica User quick reference guide

Contro l4 C4-SKCB2 installation guide

Contro l4

Contro l4 C4-SKCB2 installation guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions