Cardin Elettronica ACD-148 User manual

CARDIN ELETTRONICA spa
Via Raffaello, 36- 31020 San Vendemiano (TV) Italy
Tel: +39/0438.404011-401818
Fax: +39/0438.401831
Http: www.cardin.it
1
CODE Nr. SERIES MODEL
L183.00 ACD 148
This product has been tried and tested in the manufacturer’s la-
boratory, during the installation of the product follow the supplied
indications carefully.
32
WIRELESS ACCESS CONTROL
SYSTEM
ACD-148
IMPORTANT FOR THE OPERATOR
This statement is proof of the correct installation and testing of the appli-
ance
This document should be filled out in the presence of the client on concluding
the installation of the appliance and should be conserved as a warranty.
Date.................................................
Appliance type __________________________ Code number _________________
Applicable security N. Note
Photoelectric cells
Pneumatic safety tubes _____________ ___________________________
Luminous warning lights ____________ ___________________________
_____________ ___________________________
Radio controls _____________________ Model ____________________
STRUCTURAL CONDITION AFTER INSTALLATION
Dimensions: __________________________ Weight: ___________________
Conforms to UNI 8612 YES NO Client N.: _________________
Installed by:___________________________ Firm: _____________________
Address:______________________________ Telephone: ________________
Interventions carried out after installation
____________________________________________________________________
_____________________________________________________________________
Conserve this document even after the warranty period has expired in order to
facilitate the ordering and replacement of spare parts.
MOD. 16-03-2004

231
REMARKS
Before commencing with the installation of this appliance make sure
that you have read the following instructions carefully.
In particular familiarise yourself with the safety devices required by
the system, only then will you be able to use them to great effect.
Not all of the safety devices required by Italian or local safety stand-
ards have been taken into consideration in this manual.
The installer must make sure that any eventual safety devices re-
quired by the local standards and regulations have been installed
both ahead of and after the products described in this manual.
This appliance must be used exclusively for the purpose for which
it has been made. Any non authorised modifications are to be con-
sidered improper and therefore dangerous.
These instructions are aimed at professionally qualified “install-
ers of electrical equipment” in conformity with the standard “Nr.
46/5.3.1990”.
The manufacturer accepts no liability for damage caused by, or
situations arising from, the improper use of these appliances and
therefore all work carried out after the delivery of the appliance is to
be considered the complete responsibility of the installer.
Appendix A
Communications parameters
Using a P.C. fitted with a serial port controller the following parameters are
required
Speed: 1200 … 9600
Data bits: 8
Parity: None
Stop bits: 1
Duplex: Full
Emulation: VT100
Mode: Answer

30 3
I N D EX
Introduction ................................................................................. pag. 4
Electrical specifications............................................................... pag. 5
Interconnection and wiring.......................................................... pag. 6
Installation ................................................................................... pag. 9
Initialising the system .................................................................. pag. 10
Setting the internal clock............................................................. pag. 10
Memorising a user code.............................................................. pag. 11
Cancelling a user code................................................................ pag. 13
Enabling/disabling a user code ................................................... pag. 14
Enabling/disabling user transmitter channels ............................. pag. 14
Deleting memory ......................................................................... pag. 15
Printing options.............................................. ............................. pag. 16
Operation according to different zones....................................... pag. 18
On-Line function.......................................................................... pag. 19
Interfacing with a terminal or a P.C............................................. pag. 20
C A R D I N ACD-148 V. 3102 (1994) Cardin Elettronica S.p.A.
**** LISTS ****
1. ENABLED USER LIST
2. FORMER EVENTS LIST
3. END
ENTER >>>
Il
D1. Enabled user list
This list is the same as that obtained using option 8 from menu level B.
D2. Former events list
The appliance former events memory contains the last 198 events which provoked
the activation of a relay in output
The list appears in the following format
***CARDIN ELETTRONICA S.p.A.*** LIST of accepted former
events
1. 02/04-Transmitter #0001 Channel “A” Activated at 14:06:07.
2. 02/04-Transmitter #0002 Channel “B” Activated at 14:12:21.
3. 02/04-Transmitter #0001 Channel “A” Activated at 14:12:58.
**** END of LIST****
TYPE < ESC > to EXIT
NOTE: The following keys are used to control the information scrolling on the
screen
< SPACE > : stop scrolling
< CR > : start scrolling

4
WIRELESS ACCESS CONTROL SYSTEM ACD-148
ACD-148 is an access control system which uses a quartz radiocontrol as a per-
sonal identification device.
The radiocontrol CARDIN mod. S48 is specifically used in the ACD-148 system as
its principal characteristic is the user code which is randomly created and stored
in a non-volatile memory inside the radiocontrol itself.
Nobody, not even the owner of the specific device, is able to discover his/her own
code nor are they able to reproduce another identical code.
The central unit of the ACD-148 is based on a CPU which is able to control up 2000
codes referring to 4 different entrances and exits which can also be subdivided
into 4 different zones.
The following types of operation are possible for each code:
1. MEMORISATION OF A NEW USER CODE
2. MODIFYING THE USER’S PERSONAL DETAILS
2. CODE ENABLING/DISABLING
3. DISTINCT CODE ENABLING/DISABLING FOR EACH
OF THE 4 DIFFERENT ENTRANCES AND EXITS
4. CODE DELETION
All these operations can be carried out on site, if the operator is in possession of
the encoded access key, or remote access is available via a terminal or personal
computer network.
The device is equipped with an internal random code generator and with an inter-
face device which allows the codes to be transferred to the transmitter via direct
coupling.
The codes and user details are stored in non-volatile memory and therefore are
maintained even during blackouts.
For this reason there is also an erasing command for all the codes maintained in
memory.
The ACD-148 can be operated both on site or via the use of a terminal and the
principal operations can be carried out using either of these solutions. To complete
the user details however a terminal or personal computer is required.
The liquid crystal display allows you to follow all the operations performed by the
device and verify the completion of each action.
When an enabled code is received one of the 4 internal relays, depending on which
radio control channel has received the signal, is activated and the following infor-
mation is indicated on the display.
- User number
- Activated channel
- Date and time of activation
If a code is used which is not present in memory a warning message will ap-
pear on the display, even if the code is compatible with the S48 handshaking
procedure, but the relative channel will not be activated.
The following operations are possible via the serial connection:
- modifying the system configuration parameters, i.e. date,time,baud rate,password
etc.;
29
After an enabled user has been recognised the corresponding relay is activated.
The relay activation time, i.e. the time during which the normally open contact
remains closed can be chosen.
The relay default time is 500 mS. Choosing option 3 from menu level C will allow
you to modify this time
The following message appears on the screen:
CURRENT DELAY: 500 mS
ARE YOU SURE? [Y/N] >>
Choosing N the following message will appear
DELAYS AVAILABLE
1. [500 mS ]
2. [1 Sec. ]
3. [2 Sec. ]
4. [4 Sec. ]
ENTER [ 1- 4 ] >>>
If you choose option 2 the memorised delay time will be 1 second, i.e. the relay
will be released 1 second after it has been activated.
To cancel the operation and maintain the current delay time press the <ESC>
key.
C4. Output activation
The relay in output can be activated directly by choosing option 4 from menu level
C. The following message appears on the screen:
SELECT THE OUTPUT TO BE ACTIVATED
1. Relay1 [ CHA ]
2. Relay2 [ CHB ]
3. Relay3 [ CHC ]
4. Relay4 [ CHD ]
5. END
ENTER >>>
The chosen relay will be activated immediately and will be released after the delay
time set in C3
D. Information lists
Choosing option 4 (print utilities) from the main menu you enter the menu LIST.
The following menu appears on the screen:

5
28
- inserting or modifying user details;
- cancelling the user memory or the events buffer memory;
- modifying the relay drop-out delay time;
- displaying a complete list of the systems user’s both enabled and disabled and
the display of information regarding the last transition.
At the back of the appliance there are 4 dip-switches allowing zone partitioning
(see fig.6 page 18) e.g. these can allow programming in specific time bands by
connecting an external timer or signal reception only when the user is located
within the range of a detector.
ELECTRICAL SPECIFICATIONS
- Power supply voltage: ......................................................... 230 V ac / 50 Hz
- Power consumption: .......................................................... 35 mA @ 220 Vac
- Maximum number of memorised user codes: .................... 2000
- Maximum number of events stored in the buffer memory: 198
- Transmitter model: .............................................................. CARDIN - mod. S48
- Number of individual channels: .......................................... 4
- Number of controllable I/O’s: .............................................. 4
- Number of inputs which may be enabled: .......................... 4
- Average time lag per enabled TX: ...................................... 225 mS
- N. 4 Relays with resistive load
- Maximum commutable power
- Load in dc ........................................................................... 28W
- Load in ac ........................................................................... 60 VA
- Adjustable drop out delay ................................................... from 500 mS to 4 S.
- Maximum number of random generated codes: ................ 7077888
- Number of combinations per encoded access key:............ 16384
- 8 character password
- Stand-by battery ................................................................. 2.1 Ah
- Stand-by battery autonomy................................................. 24 hrs
- Hardware watchdog
RADIOFREQUENCY RECEPTION CARD
- reception frequency ............................................................. 27.195 MHz
- local oscillation frequency.................................................... 27.650 MHz
- local oscillation frequency.................................................... 30 p.p.m.
............................................................................................. from -10° to +55°C
- intermediate frequency ........................................................ 455 KHz
- impedance in input .............................................................. 50 Ω
- sensibility (with a finely tuned signal)................................... 0.5 µV
- local oscillation emission ..................................................... ≤70dBm (<100pW)
RS-232 INTERFACE
- CANNON 9 pole Male connector
5 : GND
3 : TX
2 : RX
- Protocol : XON / XOFF
- Baud rate : SELECTION: from 1200 BAUD to 9600 BAUD
- Parity : NONE
- N Bit : 8
C. General settings
Choose option 3 from the main menu and the following menu will appear on the
screen.
C A R D I N ACD-148 V. 3102 (1994) Cardin Elettronica S.p.A.
**** GENERAL SETTINGS****
1. CANCEL USER CODE MEMORY
2. CANCEL FORMER EVENTS MEMORY
3. RELAY DELAY
4. OUTPUT ACTIVATION
5. END
ENTER >>>
C1. Cancel user code memory.
Choosing option 1 from this menu allows you to cancel all the users from (EEP-
ROM) memory.
The following message appears on the screen:
!! CANCEL MEMORY: CANCEL ALL USER CODES !!
ARE YOU SURE? [Y/N] >>
If you answer Y twice all the user information will be cancelled from memory
Throughout this operation (the length of which depends on the amount of memorised
data) the following message will remain on the screen
** D E L E T I N G **
after which the following message will appear
TYPE < ESC > to EXIT
C2. Cancel former events memory
Choosing option 1 from this menu allows you to cancel the buffer memory which
contains the last 198 events.
The following message appears on the screen:
!! CANCEL MEMORY: CANCEL FORMER EVENTS MEMORY !!
ARE YOU SURE? [Y/N] >>
If you answer Y the buffer memory will be erased
C3. Relay delay

Collegamenti scheda ACD48
YAC048B002
05-02-2002
DC0087 Description :
Product Code :
Date :
Drawing number :
P.J.Heath
CARDIN ELETTRONICA S.p.A - 31020 San Vendemiano (TV) Italy - via Raffaello, 36 Tel: 0438/401818 Fax: 0438/401831
Draft :
All rights reserved. Unauthorised copying or use of the information contained in this document is punishable by law
S48
FUSE
1.6A
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
1 2 3 4
Iskra
TRK 1233
F 9V
Iskra
TRK 1233
F 9V
Iskra
TRK 1233
F 9V
Iskra
TRK 1233
F 9V
BUZ
1 2 3 4 5 6 94
94 95 A B C D
220V ac
Channel D
Channel C
Channel B
Channel A
Channel outputs
External devices
in input
on
Reset
Serial line
1 2 3 4 5 6 94 95 96 A B C D
C A R D I N
*****ACD-48*****
16265S
CONTRAST
ADJ
141312111098
NO
7654321
NO
7654321
NO
141312111098
+
BUFFER BATTERY
KEY-SLOT
TX-SLOT
DISPLAY P.C.B. CARD
MAIN P.C.B. CARD
CODE SECURITY
Zone selection
627
If the answer Y is given the following message appears:
CODE #### !!! D I S A B L E D !!!
TYPE < ESC > to EXIT
In this way the user #### is disabled; this operation allows you to disable a user
temporarily without having to erase the information from memory.
B7. Modifying the enable status of a particular channel
To modify the enable status of a particular channel choose option 7 from menu
level B
The following message appears on the screen:
ENTER USER NUMBER >>>
Introduce the number which appears in the first column of the list D.
The following message appears on the screen:
ARE YOU SURE? [Y/N] >>
If the answer Y is given the following message appears:
CHANNEL SETTINGS
E.g.: CHA CHB CHC CHD
Y Y N N
ARE YOU SURE? [Y/N] >>
Answer N if you wish to change the enable status; at this point the following
message appears:
- TYPE < CR > to CONFIRM , < SPACE > to TOGGLE
CHA [ Y/N ] Y
Complete the choice
B8. List of users
Choosing option 8 from menu level B a list of all enabled users appears on the
screen as follows:
*** CARDIN ELETTRONICA S.p.A. *** ENABLED USER LIST
CODE N° CHA CHB CHC CHD ENABLED/DISABLED USER NAME
0 0 0 0 y y y y E MR.JONES
0 0 0 1 Y Y Y Y E ROBERT HALL
0 0 0 2 Y Y Y Y D V.MacINTIRE
0 0 0 3 Y Y Y Y E HENRY LLOYD
0 0 0 4 N N Y Y D G.M.JENNINGS
*** END OF LIST ***
TYPE < ESC > to EXIT
Interconnection and wiring Fig.1

7
26
The following message appears on the screen:
ENTER USER NUMBER >>>
Introduce the number which appears in the first column of the list D.
The following message appears on the screen:
ARE YOU SURE? [Y/N] >>
If the answer Y is given the following message appears:
CODE #### !!! D E L E T E D !!!
TYPE < ESC > to EXIT
In this way the user #### is cancelled and the corresponding transmitter code is
removed from memory
B5. Enabling a user
To enable a user choose option 5 from menu level B
The following message appears on the screen:
ENTER USER NUMBER>>>
Introduce the number which appears in the first column of the list D.
The following message appears on the screen:
ARE YOU SURE? [Y/N] >>
If the answer Y is given the following message appears:
CODE #### !!! E N A B L E D !!!
TYPE < ESC > to EXIT
In this way the user #### is enabled; this operation is only useful if the user was
previously disabled using the procedure B6.
B6. Disabling a user
To disable a user choose option 6 from menu level B
The following message appears on the screen:
ENTER USER NUMBER >>>
Introduce the number which appears in the first column of the list D.
The following message appears on the screen:
ARE YOU SURE? [Y/N] >>
Backpanel connections Fig.2
Collegamenti scheda ACD48
YAC048B002
05-02-2002
DC0095 Description :
Product Code :
Date :
Drawing number :
P.J.Heath
CARDIN ELETTRONICA S.p.A - 31020 San Vendemiano (TV) Italy - via Raffaello, 36 Tel: 0438/401818 Fax: 0438/401831
Draft :
All rights reserved. Unauthorised copying or use of the information contained in this document is punishable by law
S48
FUSE
1.6A
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
1 2 3 4
220V ac
Channel D
Channel C
Channel B
Channel A
Channel outputs External devices
in input
on
Reset
Serial line
CH-A
CH-B
CH-C
CH-D

SCALA: 1:
Prodotti Cardin
ACD148
07-04-98
DI0004 Description :
Product Code :
Date :
Drawing number :
P.J.Heath
CARDIN ELETTRONICA S.p.A - 31020 San Vendemiano (TV) Italy - via Raffaello, 36 Tel: 0438/401818 Fax: 0438/401831
Draft :
All rights reserved. Unauthorised copying or use of the information contained in this document is punishable by law
Collegamento RS232
SET COD-GEN
MENU 1 MEMO MENU 2
POWER
MAIN BATTERY CHARGE KEY-ENABLED
CODE
TRANSFERED
KEY-SLOT
TX-SLOT
MODE
*** CARDIN ELETTRONICA S.p.A. *** LIST of former activated events ***
1. 02/04 - Transmitter #0001 Channel "A" Activated at 14:06:07.
2. 02/04 - Transmitter #0002 Channel "B" Activated at 14:12:21.
3. 02/04 - Transmitter #0001 Channel "A" Activated at 14:12:58.
4. 02/04 - Transmitter #0003 Channel "D" Activated at 15:00:45.
5. 02/04 - Transmitter #0010 Channel "C" Activated at 15:06:37.
6. 02/04 - Transmitter #0006 Channel "C" Activated at 15:19:07.
7. 02/04 - Transmitter #0004 Channel "A" Activated at 16:56:17.
8. 02/04 - Transmitter #0023 Channel "B" Activated at 16:58:00.
9. 02/04 - Transmitter #0018 Channel "A" Activated at 17:00:00.
10. 02/04 - Transmitter #0001 Channel "D" Activated at 18:00:02.
*** END of LIST ***
13 1
25 14
51
96
SET COD-GEN
MENU 1 MEMO MENU 2
POWER
MAIN BATTERY CHARGE KEY-ENABLED
CODE
TRANSFERED
KEY-SLOT
TX-SLOT
MODE
*** CARDIN ELETTRONICA S.p.A. *** LIST of former activated
events ***
1. 02/04 - Transmitter #0001 Channel "A" Activated at
14:06:07.
2. 02/04 - Transmitter #0002 Channel "B" Activated at
14:12:21.
3. 02/04 - Transmitter #0001 Channel "A" Activated at
14:12:58.
4. 02/04 - Transmitter #0003 Channel "D" Activated at
15:00:45
5. 02/04 - Transmitter #0010 Channel "C" Activated at
15:06:37.
6. 02/04 - Transmitter #0006 Channel "C" Activated at
15:19:07.
7. 02/04 - Transmitter #0004 Channel "A" Activated at
16:56:17
8. 02/04 - Transmitter #0023 Channel "B" Activated at
16:58:00.
9. 02/04 - Transmitter #0018 Channel "A" Activated at
17:00:00.
10. 02/04 - Transmitter #0001 Channel "D" Activated at
18:00:02.
*** END of LIST ***
13 1
25 14
51
96
51
96
51
96
RS232
RS232
DB9 DB9
DB9 DB25
DB9 DB25
825
By choosing option 2 from menu level B you can add the name of the user.
This option exists due to the fact that data entered directly into the ACD-148 can-
not contain names as it has no alphanumeric keyboard.
To add on a name choose option 2 from menu level B: the following message ap-
pears on the screen:
ENTER USER NUMBER>>>
Introduce the number which appears in the first column of the list D1 and con-
firm.
If the number is incorrect (the number does not correspond to a user), the following
message appears on the screen:
CODE NOT STORED!!
TYPE < ESC > to EXIT
Otherwise the following message will appear:
B2.1 ENTER USER NAME [ max 12 car ] >>:
Insert the desired information and press < CR >.
The following message appears on the screen:
ARE YOU SURE? [Y/N] >>Y
Press <SPACE> or <CR> to confirm or refuse the choice
If the answer Y is given you end the procedure and go back to menu level B. An-
swering N will take you to menu level B2.1.
B3. Modify a name
Option 3 of menu level B will allow you to modify the information relative to the
name of the user
The following message appears on the screen:
ENTER USER NUMBER>>>
Introduce the user number whose name is to be changed
If the number is correct the following message appears on the screen:
E.g.: USER NAME: Henry Smith
ENTER NEW USER NAME max 12 car ]>>:
Introduce the new name and press < CR >
The following message appears on the screen:
ARE YOU SURE? [Y/N] >>Y
Press <SPACE> to change or <CR> to confirm the choice and escape
B4. Cancelling a user
To cancel a user choose option 4 from menu level B.
Connecting to a printer Fig.3
Connecting to a computer or terminal Fig.4

9
24
INSTALLATION
Each appliance is provided internally with a 14-way binary dip-switch, the combi-
nation of which must correspond to the combination set on the two dip-switches
located in the access key (see fig.1 page 6).
If the two combinations correspond it will be possible to carry on with the installa-
tion procedure otherwise the control panel buttons will remain inoperable.
To personalise the access combination proceed as follows:
1. Open the container so as to gain access to the upper pcb card;
2. Undo the four screws holding the pcb card in place, remove the card and turn
it over, the dip-switch is located on the underside of the card;
3. Set the desired combination on the dip-switch and then set the corresponding
combination on the two serial access keys supplied with the kit;
4. Replace the pcb card and close the container.
Switch on the power either by connecting the device to the mains or by connecting
the stand-by battery and then verify the correct functioning of the two serial access
keys by inserting them into the slot on the front panel. The led Key-Enabled will
light up indicating that the key has been accepted.
If the led fails to light up but the code combinations on the ACD-148 and the ac-
cess keys are the same contact your dealer.
B1.1 ENTER TRANSMITTER CODE [ 10 characters]:
At this point activate the transmitter which is to be memorised and read the code
number which appears on the display of the device CARDIN ACD 248.
E.g.: CODE
1F451B207C
Type the code into the terminal only using uppercase letter and then press < CR
>
If the code is wrong (the code also carries redundant information to facilitate the
checksum), the following message appears on the screen:
!! CODE WRONG !! - RETYPE ? [ Y/N ]>>
If the answer Y is given you go back to menu level B1.1 otherwise you go back to
menu level B.
If the introduced code is correct but already present in memory the following mes-
sage appears on the screen:
!! CODE ALREADY STORED !!
TYPE <ESC> to EXIT
at this point you will have to create another random code and then reprogram the
transmitter
If the code is accepted the system asks:
TYPE USER NAME [ max 12 char ]>>
after typing the name and confirming the choice the following message appears
on the screen:
CODE #### ** STORED !! ** >> ENABLE ALL CHANNELS ? [ Y/N ] >>Y
If you have a 2 channel transmitter or if you don’t want to enable all the channels,
answer no, and the following message will appear:
B1.2 - TYPE < CR > to CONFIRM , < SPACE > to TOGGLE
CHA [ Y/N ] Y
Enable each channel separately by alternating between Y and N as required using
the < SPACE BAR > and confirm the choice by pressing < CR >.
The following message will then appear on the screen:
ARE YOU SURE? [Y/N] >>
Answer Y to escape or N to return to menu level B1.2
To check whether the operation was carried out correctly; return to menu level B
and choose option 8 (enabled users list). If all is well the code should appear in
the list.
B2. Add the name of the user
Control panel Fig.5
SET COD-GEN
MENU 1 MEMO MENU 2
POWER
MAIN BATTERY CHARGE KEY-ENABLED
CODE
TRANSFERED
KEY-SLOT
TX-SLOT
MODE
Membrane pannello comandi ACD148
ACD148
29-07-94
DM0058 Description :
Product Code :
Date :
Drawing number :
P.J.Heath
CARDIN ELETTRONICA S.p.A - 31020 San Vendemiano (TV) Italy - via Raffaello, 36 Tel: 0438/401818 Fax: 0438/401831
Draft :
All rights reserved. Unauthorised copying or use of the information contained in this document is punishable by law

10 23
SYSTEM INITIALIZATION
To initialize the system proceed as follows:
A. Move the 4 dip-switches (fig.2 page.7) to the “OFF” position
B. Simultaneously press the MODE and MEMO keys
The following will occur:
B1. System clock reset
B2. BAUD RATE set to 1200 BAUD
B3. Generic password set to “12345678”.
C. If all is well the display will indicate the message:
“INIT MEMORY”;
D. Simultaneously press the SET and MEMO keys
This will reset the former events buffer memory;
E. If all is well the display will indicate the message:
“DELETING FORMER EVENTS”;
F. Move the 4 dip-switches to the “ON” position
G. Press the RESET button.
C A R D I N
***** ACD-148 *****
In its normal operating mode the ACD-148 does not require enabling via the
serial key; this key is only required when system management tasks are to be
carried out (memorising new user codes, cancelling codes, setting the date and
time etc.).
SETTING THE CLOCK
1. Simultaneously press the MODE and SET keys
2. The display will show the following :
YY MM DD HH MM
0
3. Press the SET key several times scrolling the digits relative to the years (80,S-
90,s etc.).
4. Once the desired number is reached (e.g. 9 ) press the MODE key;
The cursor prompt will then move to the single year units and a starting “0” will
be shown.
5. Press the SET key once again and repeat the instructions at point 3 until the
year has been set.
6. Press the MODE key again and the cursor prompt will move to the letter indi-
cating the month
A4. Modifying the password
To personalise the system password choose Nr. 4 from the System Menu.
The following message appears on the display:
!! CHANGE PASSWORD!! ARE YOU SURE? [Y/N] >>
If the answer Y is given the following message appears on the display:
ENTRY NEW PASSWORD[ 8 characters ] >> . . . . . . .
ATTENTION: You must insert an eight digit password
To avoid typing errors the password is asked for a second time and if the two
passwords do not conform the following message appears on the display:
WRONG PROCEDURE!! - PASSWORD UNCHANGED
TYPE < ESC > to EXIT
B. USER MANAGEMENT
Choose Nr. 2 from the main menu to enter the user management menu :
The following menu appears on the screen:
C A R D I N ACD-148 V. 3102 (1994) Cardin Elettronica S.p.A.
**** USERS MANAGEMENT ****
1. ADD USERS 6. DISABLE USER CODE
2. ADD USER NAME 7. CHANNEL SETTINGS
3. CHANGE USER NAME 8. ENABLED USERS LIST
4. DELETE USER CODE 9. END
5. ENABLE USER CODE
ENTER >>>
This menu features all the user management tools which can be operated from a
remote station.
For each individual user the system is able to memorise the following data:
- an internal identification code number, the enabled status for each channel and each
code, and a 12 character string for generic data ( the name of the user etc.).
The possibility to memorise a new user from a remote terminal is also possible if
you possess the “ CARDIN ACD-248”. This device is a remote display which al-
lows you to read the S48 transmitter code number, which can then be inserted
into the terminal
B1. Programming a new user code
Choose Nr. 1 from the management menu.
The following message appears on the screen:

11
22
Repeat the above mentioned procedure until all the categories are complete:
YEAR YY YY MM DD HH MM
Example MONTH MM 93 05 08 15 37
DAY DD
HOUR HH
MINUTE MM
When the units relating to the minutes have been set, press the MODE key and
the system will complete the data by adding the seconds.
At the end of this operation the system prompts the following message:
ARE YOU SURE?>> Y
AT this point it is possible to switch between the answer Y and N by pressing the
SET key and confirming the choice by pressing the MODE key .
If the answer “N” is given the system restarts with the initial clock setting proce-
dure; If the answer Y is given the time and date are confirmed and the following
message appears:
C A R D I N
***** ACD-148 *****
The internal clock is now set.
The internal clock automatically adjusts to compensate for leap years
STEP A: MEMORIZING THE USER CODE
1.Insert the encoded key in the slot. If the code is confirmed the led “Key-Enable”
will light up; Caution: If you are using pre-encoded Cardin model S48 radio
controls go directly to point 7 otherwise carry on from point 2.
2.Press the COD-GEN button to memorise one of the randomly generated codes
and make it available for transfer to a transmitter (TX);
3. Insert a 2/4 channel S48 transmitter into the relative slot on the front
panel
4.Press the TX key relative to the channel which is to be memorised. If the code
has been correctly transferred from the ACD-148 to the transmitter the LED Code
transferred will light up.
5.Repeat operation 4 by pressing all the transmitter keys of the channels you want
to activate;
In this way the generated code is transferred from the ACD-148 to the EEPROM
in the transmitter.
pressing CHA key: code ------------> Section A of the TX
pressing CHB key: code ------------> Section B of the TX
pressing CHC key: code ------------> Section C of the TX
pressing CHD key: code ------------> Section D of the TX
If the answer Y is given the current time is confirmed and you are returned to the
system menu. If the answer N is given the following message appears:
A2.1. ENTRY NEW TIME [ HH:MM:SS]>>:
Insert the desired time following the format indicated in the brackets and then
press the return key <CR>; If the information is correct the following message
will appear:
!! UPDATED !!
Type <ESC> to EXIT
If the information is incorrect the following message will appear:
TIME WRONG! RETYPE? [ Y/N]>Y
Pressing the <space bar> alternates between Y and N, pressing <CR> confirms
the choice.
If the answer Y is given you return to point A2.1 otherwise you are returned to the
system menu without altering the time.
A3 Modifying the BAUD RATE
The system BAUD RATE can be modified by choosing Nr. 3 from the system
menu: The current BAUD RATE will appear on the screen as follows:
CURRENT BAUD RATE: 9600
ARE YOU SURE? [Y/N] >>
If the answer Y is given the current baud rate is confirmed and you are returned to
the system menu. If the answer N is given the following message appears:
BAUD RATES AVAILABLE
1. [ 1200 ]
2. [ 2400 ]
3. [ 4800 ]
4. [ 9600 ]
ENTRY NEW BAUD RATE [ 1-4 ]>>
To select the desired BAUD RATE press 1,2,3 or 4 or press the <ESC> key to
make no changes.
The following message appears after the baud rate has been chosen:
Type <ESC> to EXIT.
ATTENTION: After the BAUD RATE has been modified the system will continue to
operate using the old baud rate until the next system RESET (activated by pressing
the relative button on the back of the ACD-148) or until the next SERIAL TIMEOUT
interruption. If the BAUD RATE is changed from a remote station you must wait
for 2 minutes to pass without introducing data via the keyboard in order to update
the baud rate.

12 21
6. Remove the transmitter from the slot;
7.Press the MEMO key of the ACD-148 and the key relative to channel A of the
transmitter S48 at the same time.
Keep both pressed until the display changes and shows the following message:
TRANSMITTER WITH
MULTIPLE CODES ?>Y
8.If the answer Y is given the system moves directly to point 9 giving the possibility
to enable each channel individually. S48 in fact is able to memorize a different code
for each channel.
If the answer N is given the following message will appear:
CODE ACCEPTED
ENABLE ALL CH?>Y
9.If the answer Y is given all the channels are enabled for the same code
If the answer N is given you have the possibility to enable each channel individu-
ally:
CHA CHB CHC CHD
Y
10. Press the SET button if you wish to change the enable status of channel A.
Repeatedly pressing the SET button will alternate between “N”,”Y”,”N”,”Y”, etc.
Y = TX CHANNEL A: ENABLED
N = TX CHANNEL A: DISABLED
11. Press the MODE button to confirm the setting for channel A and move on to
the next channel
12. Repeat operations 9 and 10 until all options have been completed.
13. After the last confirmation the following question will appear:
ARE YOU SURE ? Y
14. Repeatedly pressing the SET button will alternate between “N”,”Y”, etc.
A. System menu
Choose Nr. 1 from the main menu to enter the system menu.
The following menu appears on the screen:
C A R D I N ACD-148 V. 3102 (1994) Cardin Elettronica S.p.A.
**** ****SYSTEM MENU ****
1. DATE
2. TIME
3. BAUD RATE
4. CHANGE PASSWORD
5. END
ENTRY>>>
A1. Setting the system clock ( DATE )
Choose Nr. 1 from the system menu and the following message appears:
e.g.:
CURRENT DATE : 25/12/94
ARE YOU SURE? [Y/N] >>
If the answer Y is given the current date is confirmed and you are returned to the
system menu. If the answer N is given the following message appears:
A1.1 ENTRY NEW DATE [ DD/MM/YY ]>>:
Insert the desired date following the format indicated in the brackets and then
press the return key <CR>; If the information is correct the following message
will appear:
!! UPDATED !!
TYPE <ESC> to EXIT
If the information is incorrect the following message will appear:
DATE WRONG RETYPE? [ Y/N]>Y
Pressing the <space bar> alternates between Y and N, pressing <CR> confirms
the choice.
If the answer Y is given you return to point A1.1 otherwise you are returned to the
system menu without altering the date
A2 Setting the system clock ( TIME )
Choose Nr. 2 from the system menu and the following message appears:
e.g.:
CURRENT TIME : 15:26:41
ARE YOU SURE? [Y/N] >>

13
20
15. If the MODE button is pressed with the answer “Y” on the display the system
will answer:
CODE N. ####
* S T O R E D *
This means that the transmitter code has been memorized by the system with the
progressive number: ####
16. If the MODE button is pressed with the answer “N” on the display the system
will show the start up message and no operations will be carried out:
17. To insert user information such as names or other forms of identification you
must be connected to a terminal.
STEP B: DELETING THE USER CODE
1. Press the “Menu 1” button with an enabled transmitter inserted and the
following message will appear on the display:
ENTRY CODE
NUMBER = 0000
2.Repeatedly press the SET button to change the number indicated by the cursor
prompt (from 0 to 9);
3.Press the mode button to confirm the choice and move on to the next unit of the
number to be set;
4.Repeat operation 2 and 3 until the required code is completed;
5.After the last confirmation the system asks:
ARE YOU SURE ? Y
6.Press the MODE button to confirm or the SET button to change the answer;
7.If the answer Y is given the system answers with the following message:
1=DEL 2=DIS 3=EN
4=CH 0=OUT >> 0
8.Repeatedly press the SET button until a “1” appears in the option indicated by
the cursor prompt;
INTERFACING WITH A TERMINAL
All the on site operations carried out using the control buttons on the appliance
front panel may also be executed via terminal ( VT100 compatible terminal ) or via
a PC fitted with a serial interface controller. Once the connections have been car-
ried out as shown in fig. 4 pag. 8 and the correct communication parameters have
been set (see appendix A), press the <TAB> key on the keyboard
If the communication is correct the following message will appear on the screen:
ENTER PASSWORD [ 8 characters ] >> ........
If the system has just been initialised type in the generic password “12345678 “ ,
otherwise type in your personal password. If the password is correct you will be
given access to the main menu, otherwise the following message will appear on
the display:
** END ** [ type < TAB > for MENU ].
ATTENTION: The system is “Case Sensitive”, and makes a distinction between
uppercase and lowercase letters. This means that the password:” ABCDEFGH”
is different to the password “ABCDEFGh”.
If the introduced password is correct the following menu will appear on the
display
C A R D I N ACD-148 V. 3102 (1994) Cardin Elettronica S.p.A.
**** MAIN MENU ****
1. SYSTEM
2. USERS MANAGEMENT
3. GENERAL SETTINGS
4. PRINT UTILITIES
5. END
ENTER >>>
To enter one of the sub-menus press a number from 1 to 4; to exit the menu press
number 5 or <ESC>.
The program allows you to move between menus by pressing number keys and to
exit the system using the <ESC> key.
Each time a serial connection is made the following message will appear on the
display:
SERIAL LINK
CAUTION: While the serial line is occupied the appliance is unable to receive
and process data via the radiocontrol inputs.
For this reason, if a two minute time period has passed during which no keys have
been pressed, the system will automatically return to the “ ON LINE” mode and
the following message will appear on the screen
SERIAL TIMEOUT
while the following message will appear on the ACD-148 display:
CA R D I N
*** ACD-148 ***

14 19
9.Press the MODE button. The system answers with:
ARE YOU SURE ? Y
10. Press the MODE button to confirm or the SET button to change the answer;
If the mode button is pressed the deletion of the code is conformed and the fol-
lowing message appears on the display.
CODE N. ####
* D E L E T E D *
The code is removed from the non volatile internal memory.
If however the SET button is pressed and then the mode button, the operation is
cancelled and the display will return to point 7.
11. If you wish to cancel the operation go back to point 7 and then exit the level by
confirming the 0 already shown in the display.
The system confirms that you are out of the deletion menu by showing the start
up display.
STEP C: ENABLING OR DISABLING THE USER CODE
1.Press the MENU 1 button and follow all the operations of step B up to point 7.
2.Use the SET and MODE buttons to choose option 2 ( 2=DIS ) if you wish to dis-
able a user code. If you wish to enable a new user code choose option 3 ( 3=EN
).
3.If you confirm option 2 by pressing the MODE button (code disabling) the system
will answer with the following message:
CODE N. ####
* D I S A B L E D *
If you confirm option 3 by pressing the MODE button (code enabling) the system
will answer with the following message:
CODE N. ####
* E N A B L E D *
STEP D: ENABLING OR DISABLING USER TRANSMITTER CHANNELS
In order to change the status of the channels set during the memorisation stage
(channel enabled or disabled) follow the user code deletion instructions (Step B)
up to point 7.
ON-LINE FUNCTION
Once the ACD-148 has been installed the four I/O ports can only be accessed
by users who possess a radio control with a correctly memorised code. When a
recognised code is received the system performs the following operations:
A) The relay relative to the encoded channel is activated
B) The following message appears on the display
CODE N. 0012 CH. A
08/04 16:20:14
C) The following message is sent to the printer
08/04 - Transmitter #0012 Channel “A” Activated at 16:20:14
If the received code - even if generated by a CARDIN transmitter mod. S48
- was not previously memorized, the ACD-148 will send the following message
to the display :
CODE NOT FOUND
ACCESS INVALID
If a previously disabled code - according to the procedure described in step C
- has been received, the following message will be sent to the display:
CODE N. ####
DISABLED
The following message will also be sent via the I/F232 serial line:
08/04 - Transmitter #0012 Code disabled received at 16:20:14
If the system receives a code attempting to gain access through a disabled
channel - by means of the procedure described in step D - the following mes-
sage is sent to the display :
CODE N. ####
CH. # DISABLED
The following message will also be sent via the I/F232 serial line:
08/04 - Transmitter #0012 Code CH.”A” disabled received at
16:20:14
The following situations where there is no relay activation, are not stored in the
events memory:
- Code not found, access invalid
- Code N. #### disabled
- Code N. #### Ch. # disabled

15
18
1.After reaching point 7 use the SET button to choose option 4 (4=CH) and then
press the mode button.
2. The system will show the same display as point 9 of step A:
CHA CHB CHC CHD
Y
3. Use the SET and MODE buttons and follow points 9,10,11 of step A;
4.At the end of the operation the system asks:
ARE YOU SURE ? Y
5. Use the SET and MODE buttons to select the desired answer.
If the answer Y is given the setting is confirmed and the system answers with
the following message.
C A R D I N
***** ACD -148 *****
If the answer N is given the system exits the level and goes back to point 7 of
step B. At this point you can exit the menu and cancel the operation or restart the
operation.
INITIAL DELETION OF ALL THE CODES IN MEMORY
The ACD-148 stores all the user codes in a non-volatile EEPROM memory which
maintains them even during blackouts.
In order to initialize the system a procedure is required for deleting all the codes
stored in memory.
1. Press the MENU2 button
The system answers with the following message:
1= LIST 2= EVENTS
3= ERASE 0=OUT: > 0
3.Press the MODE button to confirm the choice
The system answers with the following message:
ERASE ALL CODES
ARE YOU SURE ? Y
ENABLING AND DISABLING CHANNELS IN DIFFERENT ZONES
By means of the 4 way dip-switch located inside the container towards the rear of
the p.c.b card (see fig.6) it is possible to partition the enabled users in four distinct
zones.
Each channel of the radiocontrol transmitter has its own enabling input through
which it is possible to control the corresponding relay in output.
CHANNEL CORRESPONDENCE TABLE
TX Channel Terminal - relay N° Dip N° Enable control terminal input
A 13 - 14 1 15 - 17
B 11 - 12 2 16 - 17
C 9 - 10 3 18 - 20
D 7 - 8 4 19 - 20
Each external control device (timer, active infrared sensor, metallic mass detector
etc.) must be connected to the input binding posts in such a way so as to short
circuit the normally open contact (see fig.6):
To activate the external device move the Dip-switch of the corresponding channel
to the “OFF” position (see the above table).
EXAMPLE 1: Creating a timer controlled access system Fig.6
SET COD-GEN
MENU 1 MEMO MENU 2
POWER
MAIN BATTERY CHARGE KEY-ENABLED
CODE
TRANSFERED
KEY-SLOT
TX-SLOT
MODE
7 8 9 10 11 12 13 14 15 16 17 18 19 20
Channel A
PRG
1 2 3 4
Zone selection
Contact N.A.
Extern. Input
Esempio d'installazione temporizzato
ACD148
10-06-94
DI0005 Description :
Product Code :
Date :
Drawing number :
P.J.Heath
CARDIN ELETTRONICA S.p.A - 31020 San Vendemiano (TV) Italy - via Raffaello, 36 Tel: 0438/401818 Fax: 0438/401831
Draft :
All rights reserved. Unauthorised copying or use of the information contained in this document is punishable by law
ACD148

16 17
4.Press the MODE button to confirm or the SET button to change the answer.
If the answer Y is given the system answers with the following message:
ALL USERS WILL
BE DELETED!!>>Y
5. Answering Y starts the deletion procedure for all user codes stored in memory
(this command is irreversible).
Throughout this period the display will show the following message:
D E L E T I N G
ALL CODES
6. Once the codes have been deleted the system shows the following message:
C A R D I N
***** ACD-148 *****
PRINT OPTIONS
The ACD-148 allows 2 information listed to be sent to the RS-232 port
1) A list of all users
2) A list of former events
1. LIST OF USERS
It is possible to ask the system for information regarding all the enabled users. This
information can be printed by connecting the ACD-148 to a printer via the serial
port RS-232.
For the electrical characteristics of the connection see page 5.
The printing procedure is as follows:
1.Press the MENU2 button
The system answers with the following message:
1= LIST 2= EVENTS
3= ERASE 0=OUT: > 0
2.Press the SET button to choose selection 1 (1=LIST) and then press the MODE
button
A list will be transmitted to the printer similar to the following:
*** CARDIN ELETTRONICA S.p.A. *** ENABLED USER LIST
CODE N° CHA CHB CHC CHD ENABLED/DISABLED USER NAME
0 0 0 0 y y y y E MR.JONES
0 0 0 1 Y Y Y Y E ROBERT HALL
0 0 0 2 Y Y Y Y D V.MACINTIRE
0 0 0 3 Y Y Y Y E HENRY LLOYD
0 0 0 4 N N Y Y D G.M.JENNINGS
*** END OF LIST ***
The enabled status of each user and his internal code number appear on the
display.
2. LIST OF FORMER EVENTS
ACD-148 is able to memorise the last 200 former events. The following procedure
will allow you to print a list containing all this information.
1. Press the MENU2 button
The system answers with the following message:
1= LIST 2= EVENTS
3= ERASE 0=OUT: > 0
2. Use the SET and MODE buttons to select option 2 (2=EVENTS).
A list will be transmitted to the printer similar to the following:
**CARDIN ELETTRONICA S.p.A.*LIST of former activated events*
1. 02/04-Transmitter #0001 Channel “A” Activated at 14:06:07.
2. 02/04-Transmitter #0002 Channel “B” Activated at 14:12:21.
3. 02/04-Transmitter #0001 Channel “A” Activated at 14:12:58.
4. 02/04-Transmitter #0003 Channel “D” Activated at 15:00:45.
5. 02/04-Transmitter #0010 Channel “C” Activated at 15:06:37.
6. 02/04-Transmitter #0006 Channel “C” Activated at 15:19:07.
7. 02/04-Transmitter #0004 Channel “A” Activated at 16:56:17.
8. 02/04-Transmitter #0023 Channel “B” Activated at 16:58:00.
9. 02/04-Transmitter #0018 Channel “A” Activated at
17:00:00.
10.02/04-Transmitter #0001 Channel “D” Activated at 18:00:02.
*** END of LIST ***