Carus Adapto CAI2210 User manual

Product information
Video indoor station for hands-free talking
Carus Adapto
CAI2200, CAI2210

2

3
Table ofcontents
Scope of delivery...............................................................................................................5
Safety instructions ............................................................................................................5
General safety regulations ...............................................................................................5
Installation –protective measures....................................................................................5
Technical data....................................................................................................................6
Device overview.................................................................................................................6
Indication and operating elements...................................................................................7
Intended use.......................................................................................................................8
Max. number CAI22x0 in 6-wire operation.......................................................................8
Short description...............................................................................................................9
Basic module....................................................................................................................9
Video module...................................................................................................................9
Function key module........................................................................................................9
Installation........................................................................................................................10
Installation CAI2200 (wall mounting)..............................................................................10
Install the adapter plate ..............................................................................................10
Connect the lines........................................................................................................11
Terminating resistor CAI2200.....................................................................................11
Deinstall the device ....................................................................................................12
Installation CAI2210 (tabletop device)............................................................................13
Put up the table rack...................................................................................................13
Cable assignment.......................................................................................................13
Terminating resistor CAI2210.....................................................................................14
Install the device.........................................................................................................14
Deinstall the device ....................................................................................................14
Wiring diagram...............................................................................................................15
Connection diagram.......................................................................................................15
Commissioning................................................................................................................16
Settings ............................................................................................................................16
Ring tone selection.........................................................................................................16
Factory settings..............................................................................................................17
Pre-adjusted times......................................................................................................17
AS-address dependent image activation....................................................................17
Configuration options .....................................................................................................18
Programming the basic module .....................................................................................18
Manual programming .....................................................................................................18
Programming the function key of the basic module with Service Device TCSK-01........22
Programming the function key module .........................................................................23
Manual programming .....................................................................................................23
Programming further buttons......................................................................................24
Programming the function key module via Service Device TCSK-01.............................25
Labelling the function keys.............................................................................................25
General information on the conduit in TCS video systems .........................................26
6-wire operation .............................................................................................................26
Principle loop resistance.............................................................................................26
Measurement loop resistance.....................................................................................26
FAQ...................................................................................................................................28
Repair ...............................................................................................................................31
Cleaning............................................................................................................................31

4
Information on disposal ..................................................................................................31
Warranty...........................................................................................................................31
Service..............................................................................................................................32

5
Scope of delivery
1 x CAI22x0 (top shell, wall adapter plate or tabletop device)
2 x release bracket
4 x Phillips head screw
4 x dowel
assembly instruction
product information
instruction manual
programming table
Safety instructions
General safety regulations
!
Assembly, installation, commissioning and repair of electronic devices must be carried
out by qualified electricians and in compliance with current standards.
When working on main power connections of 230V AC, the general and regional installa-
tion and safety regulations must be met. i.e. DIN VDE 0100
TCS:BUS system installations must be in compliance with the general safety regulations
for telecommunication systems according to VDE 0800. Including:
separated cable routing of high and low voltage lines,
minimum distance of 10 cm in case of a common cable routing,
use of separators between high and low voltage lines within shared cable ducts,
use of standard telecommunication lines, e.g. J-Y (St) Y with 0.8 mm diameter,
already existing lines (modernisation) with deviating cross-sections can be used in
compliance with the loop resistance.
Installation –protective measures
!
Through suitable measures to protect against lightning, it has to be ensured that a
voltage of 32 V DC is not exceeded at each connection.

6
Technical data
supply voltage: +24 V ±8 % (power supply and control unit)
housing: aluminium anodised (colors as listed in price list)
dimensions CAI2200 H 163 mm x W 284 mm x D 16 mm
dimensions CAI2200: H 156 mm x W 284 mm x D150 mm
weight: 1370 g (CAI2200), 2102 g (CAI2210)
acceptable ambient temperature: 0 °C to 40 °C
input current: I(a) = 0.5 mA, I(P) = 7.4 mA
max. input current: I(Pmax) = 167 mA
3-wire installation necessary!
Device overview
indication ring tone
mute (red)
indication additional
functions (green)
door release
button
function key
light switch
button
call OFF-button
ring tone vol-
ume control
loudspeaker
function
keys
function indication
(green)
basic module
function key module
labelling of
the func-
tion keys
microphone
speech
button
video module
screen
4 navigation
buttons
left/right/
up/down
image
button
brightness
control
color
saturation
control

7
Indication and operating elements
Term
Function
speech button
call acceptance, activate speaking,
simplex communication
end communication
ring tone selection (door call front-door station 2 AS > AS-
border*)
door release but-
ton
door release (factory setting)
end communication
ring tone selection (door call front-door station 1 AS > AS-
border)
trigger light switch function**
function key of the
basic module
control function 8 (factory setting)
internal calling (to indoor station)
door release automatic
call diversion
ring tone selection internal call (call from indoor station)
light switch button
switching lights
ring tone selection floor call (call from the flat door)
call OFF-button
ring tone stopper
end communication
initiate the programming
indication call
OFF (red)
call OFF is activated (LED is ON) or
indication for busy speech channel (LED blinks)
indication addi-
tional functions
(green)
door call, incoming internal call, speaking activated
door release automatic or call diversion, when activated
alternatively door status indication
ring tone volume
control
ring tone volume can be adjusted continuously
function key
module
10 buttons. Each button can be programmed with 6 inde-
pendent functions:
specific connection to one front-door,
specific internal call,
indication of sensor information,
call diversion of door calls,
send control function,
send 2 control functions alternating
function indica-
tions
10 buttons. Each function key has its own function indication.
LED is ON when
a door call comes in
an internal call comes in
a control function from sensor comes in
call diversion is activated
two control functions with unique serial number are send
alternating

8
* factory setting: AS-border = 0, limit value of the AS-address areas can be configured with
configuration software configo™ or can be configured in the factory on request.
** when light switch function is activated in the front-door station
image button
in the video mod-
ule
to switch in the image resp.
for switching between different cameras
4 navigation but-
tons in the video
module
to swivel and incline a PTZ camera
(left, right, up, down)
brightness control
can be adjusted continuously
contrast / color
intensity control
can be adjusted continuously
Intended use
The CAI22x0 are video indoor stations with color screen for hands-free talking. Manual-
ly controled simplex communication can be activated.
The CAI22x0 are equipped with extended functions and can be used for internal com-
munication as well as for triggering control and switching functions in the home envi-
ronment. Further, they can be used as communication and control centrals which are
easy to operate.
The CAI22x0 are suitable for surface-mount and can be used as tabletop device.
They can be used for the operation within TCS audio systems and combined audio /
video systems.
Max. number CAI22x0 in 6-wire operation
Small and medium-
sized systems
max. number CAI22x0
VBVS05
10
Larger systems
max. number CAI22x0
AS front-door station
VS power supply and control unit
IS indoor station
Note: The max. number of front-door stations which
can be connected is limited. Details are described in
the product information!
BVS20 + NGV1011
35

9
Short description
Basic module
blue door release button with floor door release function (can be activated)
speech button: for call acceptance and changeover key speaking / listening
function key (ex works allocated with control function) with alternative allocation (can be
activated) internal call, door release automatic, call diversion
light switch button
ring tones can be adjusted by the resident, 13 ring tones can be selected
acoustic call distinction between 2 front-doors, flat door and internal call
ring tone volume can be adjusted manually
ring tone mute with optical indication
optical indication of door calls
optical display of a busy line in case of an established voice connection
automatic hands-free talking after internal call can be activated
parallel call can be activated
sending sender serial number in case of internal calls can be de-/activated, source indi-
cation at CAI11x0 or CAI2xx0 possible (with configuration software configoTM)
unlimited communication time can be de-/activated (with configuration software con-
figoTM)
(limited by other indoor or front-door stations, to which a voice connection is estab-
lished)
audio privacy function and automatic call cut-off
Video module
video surveillance: image button to activate the image resp. to switch between different
cameras
AS-dependent video image activation
4 navigation buttons (right, left, up, down)
brightness, color saturation / can be manually adjusted
integrated two-wire video receiver for direct connection to TCS video systems
Function key module
Each function key can be configured with any of the six functions.
specific connection to one front-door: Establishing a voice connection can be initiated
from the front-door or from the indoor station.
Door release by pressing the programmed button.
Key function: Establishing a voice connection to the calling front-door station, door re-
lease.
Indication: incoming door calls. (The AS-address is programmed and blocked in the
front-door station.)
Toggle: When several front-door stations are programmed, it is possible to toggle be-
tween them. The existing connection is terminated and afterwards a new connection is
established.
Specific internal calling: Key function. Sending an internal call to an indoor station. At
the called indoor station the incoming internal call can be indicated.
Sensor functions: Status indication of incoming control functions of sensors via LED.

10
Call diversion. Key function: De-/Activate the function.
Indication: Function de-/activated (does not work in case of internal calls).
Send control function with unique serial number.
Send two control functions with unique serial number alternately.
Key function (example for button 1): first keystroke –control function 11 is sent, second
keystroke –control function 41 is sent (see programming)
Indication: LED is on –control function 11 was sent, LED off –control function 41 was
sent.
Installation
Installation CAI2200 (wall mounting)
Attention!
The video indoor stations have to be (de-)installed only voltage-free!
Ensure not to over tighten the screws when installing the wall adapter plate on uneven sur-
faces. Otherwise the plate might be deformed. Further, the devices may not be locked into
position correctly on the adapter plate.
Install the adapter plate
For an optimal operation, a mounting height of 1.6 m is
recommended.
In order to connect the cables without any problems, the
device must be installed on a flush-mounted socket.
Position the flush-mounted socket behind the adapter
plate by using all drill holes. Ensure that the connection
terminal does not contact the flush-mounted socket.
Do not use the adapter plate as drilling template!
Only use the adapter plate as aid for marking the
holes.
Install the adapter plate with the four enclosed screws
to the wall.

11
Connect the lines
acceptable cross-section (diameter)
0.08 … 0.82 mm2(Ø 0.32 … 1.0 mm)
max. number of wires per terminal contact
each 2 x 0.8 mm, 3 x 0.6 mm
Further wires have to be connected via auxiliar terminals!
Use only connecting lines with the same diameter within one terminal contact.
Connect the lines according to the
labelling.
a
b
E
P
M
C
V1
V2
terminating resistor
Terminating resistor CAI2200
In delivery state the terminating resistor is inactive:
Plug the terminating resistor on the contacts on the right
side.
If the device should be installed at the end of a cable chain, the
terminating resistor must be activated.
Plug the terminating resistor on the contacts on the left side.
Install the device
Take the device into both hands and posi-
tion it on the adapter plate.
Position the device centrally on the adapter
plate and leave out a little space of 10 mm
to the bottom edge of the adapter plate.
Press the device flush to the adapter plate
(1). Slide it carefully and vertically down-
wards (2) until the lock pins of the adapter
plate lock into the holes in the rear panel of
the device.
Slide it downwards until stop.
To make sure that the device is locked cor-
rectly, slightly try to push it upwards. That
should not be possible.
Lock pins 4 x:
(1)
(2)

12
Take the device into both hands and
position it on the adapter plate.
Position the device centrally on the
adapter plate and leave out a little
space of 10 mm to the bottom edge
of the adapter plate.
Press the device flush to the adapter
plate (1). Slide it carefully and verti-
cally downwards (2) until the lock
pins of the adapter plate lock into
the holes in the rear panel of the de-
vice.
Slide it downwards until stop.
To make sure that the device is
locked correctly, slightly try to push
it upwards. That should not be pos-
sible.
Lock pins 4 x:
Deinstall the device
For deinstalling the device, the enclosed
release bracket is necessary.
Insert the release bracket into the opening
of the adapter plate behind the device (1).
Push the device upwards (2) and pull it out
towards you (3).
(1)
(2)
(1)
(3)
(2)

13
Installation CAI2210 (tabletop device)
Attention!
The video indoor stations have to be (de-)installed only voltage-free!
The table rack is pre-configured and has to be connected to a RJ45 socket. Therefore
please note the connection diagram under cable assignment.
1 adapter plate
2 lock pins
(4 x)
3 connecting cable
(2.5 m)
4knurled screws
5 grub screw
(hexagonal socket)
Put up the table rack
Turn the table rack into desired position and fix
the position by tightening the knurled screws by
hand.
The cable is already pre-installed.
Cable assignment
Wires
Plug PIN no.
Connect to
connection terminal:
2
3
4
5
6
7
8
orange-green
green-white
blue
blue-white
green
brown-white
brown
a
b
E
P
M
V1
V2
1
5
max. 60°
4
3
2

14
Terminating resistor CAI2210
Observe when installing video tabletop devices:
The installation of the lines to the connection sockets must be realised star-shaped and
must NOT be looped through.
Noncompliance leads to a video image with limited quality.
Install the device
Take the device into both hands and position it
on the adapter plate.
Position the device centrally on the adapter
plate and leave out a little space of 10 mm to the
bottom edge of the adapter plate.
Press the device flush to the adapter plate (1).
Slide it carefully and vertically downwards (2)
until the lock pins of the adapter plate lock into
the holes in the rear panel of the device.
Slide it downwards until stop.
Tighten the grub screw with a suitable
screwdriver only by hand!
To control, if the device is locked correctly,
slightly try to push it upwards. That should not
be possible.
Deinstall the device
Loosen the grub screw for dein-
stalling the device. Take the de-
vice into both hands.
Push the device upwards (3) and
pull it out towards you (4).
Lock pins 4 x:
(1)
(2)
(4)
(3)

16
Commissioning
!
First install the system completely, than connect it to the mains voltage!
Install the devices of the system completely.
V1 and V2 must not be connected with the P-, a- or b-wire.
When connecting the video wires V1 (+) and V2 (−) the polarity must be observed.
Proof the a-, b- and P-wire against each other on short-circuit.
Switch on the main voltage.
Settings
Ring tone selection
For 4 different incoming calls (calls from 2 front-door stations, floor call, internal call) the
ring tones can be selected.
1
End voice communication: Press call OFF-button and
keep it pressed for around 8 s. A positive acknowledgement tone sounds.
The ring tone selection is activated.
By pressing the following buttons a ring tone can be selected. You can choose be-
tween 13 tones. 7 alpha tones, 6 gong tones.
2a
select door ring tone
of the front-door sta-
tion*
Press the door release button until the required ring tone
sounds. The ring tone selected last, will be stored.
2b
select door ring tone
of the second front-
door station
(if available)
Press the speech button until the required ring tone
sounds. The ring tone selected last, will be stored.
2c
select door ring tone
of the floor door
Press the light switch button until the required ring tone
sounds. The ring tone selected last, will be stored.
2d
select internal call
tone
Press the function key as often as the required ring tone
sounds. The ring tone selected last, will be stored.
3
Press call OFF button short.
In case that no button is pressed for around. 8 sec, the device ends the ring tone
selection automatically. An acknowledgement tone sounds, the ring tone selection
is deactivated.
* The first configuration of this door ring tone is adopted for the second front-door station.
Only after having select the ring tone for the second front-door station separately (2b), it always has to be selected in-
dependently.

17
Factory settings
Ex works the following settings are stored in the device:
serial number for parallel call
1000000
function key
control function 8
Pre-adjusted times
communication time
2 min
flashing period of the green LED, if the voice
channel is busy after the voice communication is
established
3 sec
3 x flashing
internal standby time, if the device is calling or is
called
around
30 s
floor door release time
around
30 s
AS-address dependent image activation
If there are also front-door stations without cameras in a system with CAI22x0 and video
front-door stations, the image is not activated when the CAI22x0 is called by an audio
front-door station.
To guarantee this function, the possible AS addresses are separated into two sections:
AS address
0 –31*
reserved for video front-door sta-
tions
the image is activated in case of a
door call (from max. 16 video front-
door stations)
AS address
as of 32*
free, for front-door stations with-
out camera
the image is not activated in case of a
door call
*) The video AS-border can be configured with the configurator configoTM.
Note:
The AS-addresses of the front-door stations have to be assigned via Service Device.
For detailed information see point Service information in the TCS Installer 5 / 4 (Version 1) or TCS Installer 7 / 4 (Ver-
sion 2).

18
Configuration options
Function
manually
TCSK-01
configoTM
as of version
1.7.x
fixed simplex communication
–
–
x
simplex communication to the front-door
station
–
–
x
ring tone volume
x
–
–
ring tones for 2 front-door calls, internal
calls and floor calls
x
–
x
call diversion
x
x
x
door release automatic
x
x
x
internal call via function key
x
x
x
control function 8 via function key
x
x
x
parallel allocation
–
x
x
floor door release function on / off
x
–
x
automatic hands-free talking after internal
call on / off
x
–
x
determine door call AS-border
–
–
x
block ring tone output
x
–
–
block ring tone selection
x
–
x
block programming
x
–
x
programming function key module
x
–
–
Reload factory settings
x
–
x
determine video AS-border
–
–
x
Programming the basic module
Manual programming
Legend for programming
press button shortly
negative acknowledgement
(NoProg tone)
press the button until...
repeat
release the button
further
LEDs off
LEDs blinking

19
The programming is realised in four steps:
1
2
3
4
Initiate the programming
Pre-selection
End-selection
End the programming
1
Initiate the programming
Press the call OFF-button (8 sec), release
until an acknowledgement tone sounds shortly
Programming func-
tion
2
Pre-selection
3
End-selection
Press the button (8 sec) until an acknowl-
edgement tone sounds shortly and the green
LED blinks, release the button
shortly press the button,
an acknowledgement tone sounds
shortly and the green LED expires
door release automatic
call diversion
Note: Before program-
ming the call diversion,
the AS-address of the
front-door station is to
be fixed and blocked.
Execute at the required indoor station:
press speech button

20
Programming func-
tion
2
Pre-selection
3
End-selection
internal call
(at function key)
Execute at the required indoor station:
press speech button
control function 8
(on function key)
automatic hands-free
talking after internal call
switch on (when
switched off) or
switch off (when
switched on)
switch on floor door
release function (if
switched off) or
switch off (if switched
on)
parallel allocation
Execute at the required indoor station:
press speech button
delete
parallel allocation
This manual suits for next models
1
Table of contents
Other Carus Intercom System manuals

Carus
Carus CAI 1100 User manual

Carus
Carus CAI 2010 User manual

Carus
Carus IRIS CAE100 Series User manual

Carus
Carus Adapto CAI2100 User manual

Carus
Carus ARGOS User manual

Carus
Carus Adapto CAI1200 User manual

Carus
Carus ARGOS CAE3 02-IP-015 Series User manual

Carus
Carus IRIS User manual

Carus
Carus Adapto CAI1100 User manual

Carus
Carus CAI2300-015X User manual