CONTENTS
1. Precautions Before Using The Scale ..................5
2 . Overall view.............................................................8
3. Installation................................................................9
4. Explanation Of Display Symbols .......................11
5. Keypad Functions ............................................... 13
6. Operations ............................................................ 14
A.Switch on / off....................................................................14
B.Zero the scale ...................................................................14
C.Sampling before counting ................................................14
D.How to use memory cells.................................................16
E.Subtract container’s weight ..............................................18
F. Weight/Quantity accumulation.........................................21
G.Preset counting check range ...........................................22
H.Preset weight check range ..............................................24
7. User Programming Functions ............................. 26
A.Auto. shut off time setting.................................................26
B.Zero Tracking range .........................................................27
C.Zero display range ...........................................................27
D.Stable class range............................................................28
E.Stable class rate ...............................................................28
F. Backlight type ...................................................................29
G.Change unit of measure from kg to pound .....................30
H.Unit weight recomputing ..................................................31
I.Check alarm type...............................................................32
J.Baud rate setting ...............................................................34
K.Transmit method setting...................................................34
L.
Label format setting(available when a label printer is connected.)
35
M.Cancel Tare setting ..........................................................35

4
8. Calibration(can be done in kg/lb) .........................36
9. Power supply & battery operation .......................37
10. RS-232 Output .......................................................38
11. Error Codes............................................................45
12. Technical Data.......................................................46

5
1. Precautions Before Using The Scale

6

7
Environment
The scale should always be used in an environment, which is free form excessive
air currents, corrosives, vibration, and temperature or humidity extremes.
These factors will affect displayed weight reading.
DO NOT install the scale :
●Next to open windows or doors causing drafts or rapid temperature changes.
●Near air conditioning or heating vents.
●Near vibrating, rotating or reciprocating equipment.
●Near magnetic fields or equipment that generates magnetic fields.
●On an unstable work surface
●In a dusty environment
●In direct sunlight.
Leveling the Scale
The scale is equipped with a level indicator on the back side at the middle of platform and
four adjustable leveling feet. Adjust the leveling feet until the bubble appears in the center
of the circle.
Turn on Scale
Do not turn on scale with anything on the platform.
After switch at the bottom of indicator ON, The scale will start to count down from 9 to 0. It
is self checking time to be ready for use the scale.
Besides, should give a warm-up for 15 ~ 30 mimutes before use.

8
2. Overall view

9
3. Installation
1. Open the box with care because indicator is connected to the scale with
load cell wire.
2. Turn the post knob so as to fix indicator.
3. Pull down the wire out of post pipe and insert the post pipe to the post
bracket. (Refer to fig. 1)
4. Fasten the post pipe with two bolts. (Refer to fig. 1)
5. Insert the wire to the post pipe. (Refer to fig. 2, 3)
6. If the scale is not properly level, please adjust 4 leg(adjusting bolt) at the
bottom of the scale so as to center the bubble of the leveling gauge.
Note : Place the scale on a flat and stable surface.※
Inside the indicated circle.

10
※
Note
: Before using the scale, unscrew the five shipping protection
screws. If not, the weighing operation works wrong.
1) Location of screws
2) Adjusting procedure

11
4. Explanation Of Display Symbols
1) Display Windows
z Weight Display: Total 6 digits for weight accumulated or being measured on the
platform.
z Unit Weight Display: Total 6 digits for unit weight or times of weight accumulated.
zCount Display: Total 6 digits for number accumulated or being counted on the
platform.
2) Indicated Symbols
Sysmbols Specification
Scale is in TARE mode.
Scale is in ZERO mode.
Scale is in ACCUMULATION mode.
The display reading is in STABLE condition.
Lack of Sample Weight
If the total sample weight on the platform is less than 10 display divisions,
a triangular indicator will appear to remind the user to add more samples
until the indicator disappears.
Lack of Unit Weight
If the unit weight is less the 1/10 display divisions, a triangular indicator will
appear to remind the user that the displayed unit weight is too small for
getting accurate quantity calculations.
Low Voltage

12
5. Keypad Functions
Keys 내용
~ Numeric keys
Decimal point key
Use this key to clear out the displayed numeric readings.
If there is a minor weight displayed without anything on the platform,
press the zero key to clear the display.
Use this key to subtract the container’s weight, indicates that the current
weight reading is net weight.
Use this key to input sample size.
Use this key to input the known unit weight of item to be counted.
Use this key to input the HIGH & LOW weight/quantity limit for check
function.
Use this key to accumulate weight/quantity measured.
Use this key to recall total weight, count & accumulation on times.
Use this key to preset TARE weight.

13
Use this key to enter into User Programming Functions.
Use this key to confirm the parameter setting
Use this key to move the parameter value in Set Mode.
Use this key to memory a value to a location.
Use these 24 blank keys to store values in memory.

1
4
6. Operations
A. Switch ON/OFF
Push the on & off switch at the bottom of indicator to turn on or off the scale.
B. Zero the scale
Press ZERO key to return the display to zero in case there is any zero drifting while unloaded.
C. Sampling before counting
1) Unknown unit weight
● Place a few pieces of item to be counted on the platform.
● Input the quantity of item on the platform.. (ex. 50pcs)
● Press SMPL key
Note : The system default is “Unit Weight”. If the “SMPL” key is clicked when the value (ex : 40) in
COUNT window is blinking, then the numerical value input will be as “Quantity”.
If the “SMPL” key is not clicked when the value (ex : 40) in COUNT window is blinking,
then the numerical value input will be as “Unit Weight”.

15
● The sampling operation is completed while stable display appears as below :
※
The larger sample size, the more accurate unit weight
※ Press SMPL key to recomputing unit weight during in counting process if the setting of
“Unit Weight Recomputing” set to “on”
2) Known unit weight
● Input the known unit weight. (ex. 40g)
● Press U.Wt key to complete sampling operation & enter into counting mode.
Note : The system default is “Unit Weight”. If the “U.WT” key is clicked when the value (ex : 0) in
COUNT window is blinking, then the numerical value input will be as “Unit Weight”.

16
D. How to use memory cells
1) How to store into direct/indirect memory cells
● Give a long press of MEMORY key. Then the display as below will be shown up.
Input the unit weight values by using numeric key(ex. 35g). After input U/W, press ENTER
key to to Confirm it and move on the next step.
Note : Press the MOVE key to change the value when a wrong value is entered.
● The second step is for storing Tare value. So, Input the tare value (ex. 10kg) and press the
ENTER key to confirm it and move on the next step.
● The third step is for storing item number. So, Input the item number (ex. 800125)and press the
ENTER key to confirm it and move on the next step.
Note : You can enter up to 6 digits

1
7
● The fourth step is for storing address cell. There are two memory spaces :
Direct memory / In-Direct memory:
[Into direct memory]
Press one of Direct memory keys (Total 24 keys) which you want to use stored values for recalling.
Then, the scale will be back to the normal counting mode directly.
[Into indirect memory]
Input an address number by using Numeric key(1~100) and Press ENTER key to confirm it.
Then, the scale will be back to the normal counting mode directly.
※ 1) An error massage “E4” appears if the address code is out of “1 ~ 100”.
Then press MOVE key to return to last step. Press CANCEL key to exit the storing mode.
2) When the address number has been used, the display will be shown as below.
At this time, if you want to still use the address number, press ENTER key to confirm it
If you want to change the address number, press MOVE key to go back to the fourth step again.

1
8
2) How to recall stored memory
[From direct memory]
Just press the direct memory key one time which you already stored in it..
[From indirect memory]
Press the address number by using numeric keys which you want to recall and then press MEMORY key
Twice rapidly.
※ 1) Place parts on the platform, you will know the number of parts.
2) Press the C key to exit from recalling memory mode.
3) Press the U.WT key during recalling memory mode to check address & item number.
E. Subtract container’s weight
1) Weight unknown
● Place a container on the platform.
● Press TARE key

19
● After operate Tare function well, indicators of stable( ) & Net weight( ) will appear as below.
2) Container’s weight known
☞With no weight on the platform
Nothing on the platform
● Press P.TARE key
● Input container’s weight value by using numeric keys(ex.0.96kg)
● Press P.TARE key again.

20
☞ With some weight on the platform
Scale is loaded
● Press P.TARE key
● Input container’s weight value by using numeric keys (ex. 0.5kg)
● Press P.TARE key again.
※Eliminate TARE
Remove all weights from the platform. If so the weight display will show a negative (-)
container’s weight. At this moment, Pressing TARE key will bring the weight display to zero.
Then TARE indicator( ) will be disappeared.

21
F. Weight/Quantity accumulation
● Place item to be weighed / counted on the platform.
● Press ADD key. Display images will be shown as below in sequence.
● Press TOTAL key or wait approx. 2 seconds, the scale will return to counting mode.
※The weight window should be zeroed before the next accumulation.
● Following to the process above, you can add up whatever you want continuously.
After then press TOTAL key. Then the total weight will be shown on WEIGHT window,
the total count will be shown on COUNT window and the number of accumulation
will be shown on UINT WEIGHT window.
● Press TOTAL key to enter into accumulation status mode. At this moment, total accumulated
weight is shown on WEIGHT window, total accumulated times is shown on UNIT WEIGHT
window and TOTAL PIECES is shown on count window.
PressTOTAL key again to go back to counting mode.
Table of contents
Other CAS Scale manuals
Popular Scale manuals by other brands

American Weigh
American Weigh AMW-250i user manual

Rice Lake
Rice Lake Roughdeck AX Technical manual

Steinberg Systems
Steinberg Systems SBS-KW-1000/10G user manual

Pelstar
Pelstar Health o meter Professional 8320KL Operation Manual for Reference & Training

Mesko
Mesko MS 3160 user manual

Jata hogar
Jata hogar HBAL1300 Instructions of use