CDVI ROFU BKC-5000B User manual

ROFU BKC-5000B Bluetooth Access
Control Keypad Instructions
Features:
Applicable card mode : EM Card / Key Fob
1 Administrator and 200 Users
200 Proximity Cards / Key Fobs
Access Modes : Use Bluetooth smartphone,
Card / Key Fob or enter passcode to access
Built-in Tamper alarm and Buzzer (85dB)
User Management : Add / Delete / View user
data, Grant user access for specific dates or
time periods, Change user passcode
Ability to add proximity card / fob to the
ADMIN or a user by reading the card instead
of typing the numbers (See page 8)
Audit trail logs for last 1,000 events
Alarm output to notify that tamper alarm has
been triggered
Overhead LEDs and Backlit keys for easy use
in the dark
Wrong code lockout : if an incorrect passcode
is entered 3 times in a row, the keypad will
lock down for 60 seconds
Specifications:
Operating Voltage : 12VDC / 24VDC
Bluetooth Module : BLE 4.2 Bluetooth Low Energy
Current Draw :
Standby Current:
52mA@12VDC; 30mA@24VDC
Working Current:
62mA@12VDC; 35mA@24VDC
Read Range : 3.5cm
Frequency : EM 125KHz
Bluetooth Operating Distance :
Up to 50 meters (164 ft) without blocking by metal
or concrete wall / door frames
Smartphone Compatibility : Android 5.0 and up,
iOS 9.0 and up
Working Temperature :
-20°C~+50°C (-4°F~+122°F)
Dimension : 123 (L) x 79 (W) x 23 (D) mm
Finish : Zinc Alloy
Copyright All Rights Reserved ROFU Security International Corp. ROFU BKC-5000B. Published: February 12, 2020 1
RFU
O
a Company

Copyright All Rights Reserved ROFU Security International Corp. ROFU BKC-5000B. Published: February 12, 2020
BKC-5000B Pre-Installation
LED & Audible Indicators
BKC-5000B Wiring Diagram
2
Parts List:
Flat head phillips screws,
Cone point
Three-point screwdriver
(special tool)
Anchor bolts x4
Proximity key fob x1
Proximity EM cards x2Crimp connectors x12
Three-point security screw x1
x4 x1
(BKC-5000B have same wiring and pin setting)
Power on, Standby mode
Unlocked, Door always unlocked
Invalid access, Door always locked
Blue
Green
Red
1 Short beep
1 Long beep
2 Short beeps
3 Short beeps
Constant beeping
Key press
Valid access, Reset is completed
Login completed
Invalid access, Forget to press #
after entering passcode within
30 seconds
Bluetooth device vandalized,
Door sensor is on
LED Status Audible Beeps Status
Reset Procedures
1. Power off Access Control Reader.
2. Move the Pin Jumper to P2 and P3, then power on.
3. Hear a long beep to complete resetting procedures.
4. Move the Pin Jumper back to P1 and P2 to Normal setting.
5. Login as Admin and check all users, audit trail events are all cleared and everything is reset to
factory default setting, except device name.
RTE (Request-To-Exit)
RTE (Request-To-Exit)
DS (Door Sensor)
DS (Door Sensor)
NC (Fail-Safe Electrified Lock)
COM
NO (Fail-Secure Electrified Lock)
V- (Power Supply)
V+ (Power Supply)
ALM (Alarm Output)
ALM (Alarm Output)
(Polarity
Insensitive)
Green
Green
Brown
Brown
Yellow
White
Blue
Black
Red
Orange
Orange
Cable
Normal
Buzzer
Jumper Pin Setting:
Reset
(Default)

Copyright All Rights Reserved ROFU Security International Corp. ROFU BKC-5000B. Published: February 12, 2020 3
Install Crimp Connectors
Crimp connectors included:
Use a pair of crimping pliers designed to crimp insulated connectors. Place the crimp connctor
into the compression slot. Be sure the crimping jaws are positioned over the stripped portion of
the wire. Squeeze the handles together with enough force to crush the end of the butt splice.
Crimp connectors
BKC-5000B Keypads Installation
Template Flat head phillips screws
Three-point security screw
Anchor bolts
System wiring
Open BKC-5000B Keypad by loosening and removing the back case three-point security
screw at the bottom with the special tool.
Use the provided drilling template to accurately locate and drill the required holes.
Use the screws provided to mount the back case on the wall. Be sure to draw the
wiring through the large center hole in back case, and keep level.
Connect accurately the system wiring following the label enclosed on the rear.
Put the unit back and screw it on by using the special tool.

Copyright All Rights Reserved ROFU Security International Corp. ROFU BKC-5000B. Published: February 12, 2020 4
ROFU B5000 APP
(a) Download ROFU B5000 APP
Download the ROFU B5000 APP to set up. Scan QR code
on the left or go to Apple Store or Google Play depending
on what kind of smartphone you use.
Press to go to Device page. Select the designated Bluetooth
device as shown on .
Login first ,
Administrator : Enter Admin ID and Admin Passcode to
login.
Default Admin ID: ADMIN
Default Admin Passcode: 12345
User: Enter User ID and User Passcode to login
User ID and User Passcode are given by the Administrator.
[Note]
1. Administrator ID”ADMIN” can not be changed. We recommend
changing Admin’s default passcode “12345” right after you login
as the admin. Go to setting page, tap Admin Passcode to edit
Admin Passcode.
2. Admin passcode and User passcode are also used as keypad
access passcodes.
(b) ROFU B5000 App for Administrator and Users
(c) Administrator Settings Page
(d) Administrator Settings Page User Management
Add / Delete / Edit User Information Press “Users” to edit
Individual user’s
Information. You can
add a user, delete a user,
and select individual
user to adjust a specific
setting.
Note:
User passcode is set as
keypad access code and
access type is set to
permanent by default.
Press to go to “Settings” page as shown .
Click to select the device name and press the OPEN button or the
door icon to unlock.

Copyright All Rights Reserved ROFU Security International Corp. ROFU BKC-5000B. Published: February 12, 2020
ROFU B5000 APP
5
Administrator Settings Page Introductions
You can Add / Delete /
Edit user information.
Audit Trail is tracking last 1000
event logs, including Tamper
Alarm. Audit Trail can be
exported in an excel file.
Tap to export all events to
excel file.
Tap to refresh all events.
Backup Data is to backup all data
to Administrator’s phone and can
be restored except Device Name,
Audit Trail logs and Device Times.
You can restore the last backup
data to a new Access Control
Keypad / Reader.
User Audit Trail Backup Data Restore Backup
Device Name Admin Passcode Door Sensor Lock Action
Device name can be edit as a
model number, Office, Front
door, Gate, etc.
12345 is Admin default
passcode. It’s important to
change your Admin passcode
Immediately.
You can enable Door Sensor
when you connect to a closed-
circuit magnetic sensor or a
monitored door lock that has
door sensor (or lock sensor)
outputs to monitor the open or
closed state of a door.
3 options. You can choose
Door Re-lock Time, Door
Always Unlocked and Door
Always Locked.
Make sure to set up Device Time
precisely as your current time
zone of where you are. It helps
having correct and precise data
and information.
See firmware version of Bluetooth
access and control keypad/reader.
Tamper Alarm Door Re-lock Time Device Time /
Firmware Version About Us
You can activate Tamper Alarm, if
the device is vandalized, the
tamper alarm will howl
immediately and won’t go off until
it’s switched off by Administrator.
Tamper Alarm is deactivated by
default.
Tap “About Us” to show Device
Model, APP version, website
and E-mail information.
You can set the door re-lock
time interval between 1 to 1800
seconds.

Copyright All Rights Reserved ROFU Security International Corp. ROFU BKC-5000B. Published: February 12, 2020
ROFU B5000 APP
6
Administrator Settings Pages - User Management
Edit User Information
ID PASSCODE
Tap user “ID” to edit ID
(Up to 16 character).
Keypad & Card /
Fob Access
Access Types Temporary
ScheduledNumber of Times
Tap user “PASSCODE”
to edit PASSCODE
(4 to 8 digits).
Tap user “CARD/FOB” to
enter assigned 10 digits
code printed in card/fob.
Keypad and Card/Fob
Access can be
independently enabled /
disabled for a user.
Tap “ Access Types” to choose Permanent, Temporary, Number of Times
or Scheduled. The App is set to give Permanent access by default.
Tap “Temporary” to set specific
access time periods
Tap “Number of Times” to set
Number of access granted to user.
Tap “Scheduled” to assign repeatedly access on specific days and hours
for a certain period of time. This setting is useful when temporary
access on a regular basis is needed.

Copyright All Rights Reserved ROFU Security International Corp. ROFU BKC-5000B. Published: February 12, 2020
ROFU B5000 APP
7
Auto Proximity Range Adjustment and Auto Unlock Function
Administrator Interface:
Figure Tap to go to Device List page as .
Figure Select the desired Bluetooth Access Control Keypads / Readers around you.
Tap Settings button to go into Settings page as figure to select “Proximity Read Range”.
Figure Adjust “Auto Proximity Range” for Auto unlock function between 0 to 20.
Figure Back to the main page. Tap “Auto” to enable Auto unlock function to access.
Figure Tap to go to Device List page as .
Figure Select the desired Bluetooth Access Control Keypads / Readers
around you.
Tap Settings button to go into Settings page as figure to select
“Proximity Read Range”.
Figure Adjust “Auto Proximity Range” for Auto unlock function between
0 to 20.
Figure Back to the main page. Tap “Auto” to enable Auto unlock function
to access.
Auto Proximity Range Adjustment and Auto Unlock Function
User Interface:
Note:
Make sure to disable Auto before pressing to enter Setting page.
Auto proximity range indicates approximate distance between mobil
app and Bluetooth keypad / reader. Scale is arbitrary.

Copyright All Rights Reserved ROFU Security International Corp. ROFU BKC-5000B. Published: February 12, 2020
ROFU B5000 APP
BKC-5000B Operation Instructions
8
ROFU BKC-5000B Bluetooth keypad can be accessed either to unlock or logged in with your
smartphone when the devices are within 50 meters (164ft) distance. The response time of
Bluetooth signal may vary depending on mobile device.
Add Proximity Card /Fob to A User by Reading the Card on The Keypad
Add card / fob numbers to the ADMIN:
Add card / fob numbers to a user:
Swipe the card
on the keypad
Swipe the card
on the keypad
Bluetooth range
Up to 50 meters
(164 ft)
Keypad Passcode Access
After login is complete, you can enter your
passcode follow by “#” to unlock the door.
For example, if your passcode is 12345,
enter 1 2 3 4 5 #
Other CDVI Door Lock manuals