3
• MMA
-
The VRD (Voltage Reduction Device) can be activated, which
reduces voltages to below 12 V, which means that the weld-
ing machine can be used in ambient conditions in which there
is a high electrical risk, thereby providing maximum opera-
tor safety.
-
Arc Force to select the best dynamic characteristics of the
welding arc (only adjustable with the RW22 control panel).
-
Hot Start to improve ignition with particularly difficult electrodes
(only adjustable with the RW22 control panel).
- Anti-sticking function to avoid the electrodes sticking.
Usage limits (IEC 60974-1)
The use of a welder is typically discontinuous, in that it is made up
of effective work periods (welding) and rest periods (for the posi-
tioning of parts, the replacement of wire and underflushing opera-
tions etc. This welder is dimensioned to supply a I2max nominal
current in complete safety for a period of work of X% of the to-
tal usage time. The regulations in force establish the total usage
time to be 10 minutes. The work cycle is considered to be X% of
this period of time. If the permitted work cycle time is exceeded,
an overheat cut-off occurs to protect the components around the
welder from dangerous overheating. Activation of thermal protec-
tion is signaled by “t° C” flashing on control panel display (for fur-
ther information see the RW21 / RW22 control panel manual). After
several minutes the overheat cut-off rearms automatically and the
welder is ready for use again.
Technical data
The general technical data of the system are summarized in ta-
ble 1.
How to lift up the machine
The weld machine has a strong handle all in one with the frame,
used for transporting the machine manually only.
NOTE: These hoisting and transportation devices conform to Eu-
ropean standards. Do not use other hoisting and transportation
systems.
Open the packaging
Upon receiving the system:
•
Remove the welding generator and all relevant accessories-
components from their packaging.
•
Check that the weld machine is in good condition, if not report
any problems immediately to the seller-distributor.
•
Make sure all ventilation grilles are open and that no foreign bod-
ies are blocking the air circulation.
Serial number
The welding machine’s serial number is shown on the unit’s data
plate.
The serial number provides the key to tracing the production lot
applicable to the product. The serial number may be essential with
ordering spare parts or planning maintenance.
Installation
The installation site for the system must be carefully chosen in or-
der to ensure its satisfactory and safe use. The user is responsi-
ble for the installation and use of the system in accordance with
the producer’s instructions contained in this manual. Before install-
ing the system the user must take into consideration the potential
electromagnetic problems in the work area. In particular, we sug-
gest that you should avoid installing the system close to:
• Signalling, control and telephone cables.
• Radio and television transmitters and receivers.
• Computers and control and measurement instruments.
• Security and protection instruments.
Table 1
Model RAINBOW 201 HF RAINBOW 182 HF PRO RAINBOW 202 HF PRO
TIG DC MMA TIG DC MMA TIG DC MMA
Single-phase power supply 50/60 Hz V 1~230 ±20% 1~230 ±20% 1~230 ±20%
Mains supply: Zmax (*) Ω0,19 0,19 0,19
Power input @ I2Max kVA 8,5 9,0 6,9 8,3 8,5 9,0
Delayed fuse (I2@ 100%) A201620
Power factor / cosφ0,67 / 0,99 0,67 / 0,99 0,67 / 0,99
Maximum efficiency degree η0,82 0,84 0,82 0,84 0,82 0,84
Open circuit voltage V889088
Current range A 5÷200 5÷160 5÷180 5÷160 5÷200 5÷160
Duty cycle @ 100% (40°C) A 120 110 110 80 120 110
Duty cycle @ 60% (40°C) A 140 130 130 100 140 130
Duty cycle @ X% (40°C) A 200 (25%) 160 (30%) 180 (25%) 160 (20%) 200 (25%) 160 (30%)
Standards IEC 60974-1 • IEC 60974-3 • IEC 60974-10
Insulation class IP 23 S IP 23 S IP 23 S
Protection class FFF
Dimensions mm 390-300-135 390-300-135 390-300-135
Weight kg 7,5 7,5 7,5
(*) Mains supply Zmax: maximum impedance value allowed for the grid according to the EN/IEC 61000-3-11 standard.
WARNING: This equipment does not comply with EN/IEC 61000-3-12. If it is connected to a public low voltage system, it is the responsibility
of the installer or user of the equipment to ensure, by consultation with the distribution network operator if necessary, that the equipment may
be connected.