manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Chenzhu
  6. •
  7. Surge Protector
  8. •
  9. Chenzhu CZLB series User manual

Chenzhu CZLB series User manual

CZ.CZLB.11(S)E-4.3/15.05
Maintenance
User Manual
危险区
Surge Protective Devices
Caution
Please check whether the product type on the package accords
to the ordering contract;
Read this manual carefully before installation or use. If there is
something unclear ,you can dial our technic support hotline;
Prevent friction, avoid electrostatic;
Users are not allowed to dismantle or repair the SPD otherwise
it will induce malfunction.
Disassembly
Installation
Connections
54
Add: Building 6, 201 Minyi Road, Caohejing Hi-Tech Park
Songjiang New Industrial Park, Shanghai 201612, P.R. China
Tel : +86-21-64513350 Fax : +86-21-64846984
Email:chenzhu@chenzhu-inst.com
http://www.chenzhu-inst.com
(1).When using the SPD,you must have a reliable grounding.
(2).Check again wiring and polarity are correct before SPD energizing.
(3).The products were test strictly before leaving factory. If users find any
abnormalities in the module, please contact the nearest agent or our
company.
(4).In 5 years from the delivery date, if the product works improperly during
normal operation, we will repair or replace it without payment.
CZLB series
(1).The SPDs adopt screw terminals;
(2).The wires are single or multiple cables with a cross section area of
1 ~ ;
(3).The length of bared wire is about 8mm,locked tightly by M3 bolt.
2 2
.0mm 2.5mm
Wrie
W 4mm ≤
2 2
1.0mm <S <2.5mm
8mm L 10mm ≤ ≤
1 2
3
2
1
(1).Insert a screwdriver (its edge length≤6mm)into the downside
metal lock of the SPD;
(2).Push the screwdriver upwards to open the metal clip;
(3).Take the SPD out of the guide rail.
This SPD is designed for mounting on 35mm DIN guide rail.
Installation according with the following steps:
(1).Make the upside of the SPD locked into the guide rail;
(2).Push the downside of the SPD in the rail.
Summarize
Specification
Voltage bandwith
(-0.5dB)
Resistance
per path
Leakage current
Response time
Protection level
Up(line to line)
Protection level
Up(line to ground)
Rated operating
voltage Un
Max.operating
voltage Uc
Max.operating
current IL
Model designations
1 2 3
Type
-
-
Parameter
Feature:
(1).Easy replacement of protection modules.
(2).Space-saving :case width of only 7.6mm.
(3).Earthing via DIN rail to simplify field wiring.
1Ω/line 1Ω/line
10MHz 10MHz
40V 60V
600V 600V
5VDC
6VDC
250mA
24VDC
32VDC
250mA
CZLB-5(T2)
CZLB-5(R3)
<3uA <1uA
<1ns <1ns
CZLB-24P
24VDC
16A
32VDC
<1uA
85V
600V
<1ns
CZLB-24(B2)
CZLB-24(B3)
Rated discharge current
Max. current Imax:
Ambient temperature
Relative humidity
Dimensions(L x W x H)
Connections
Max.sectional area
Installation
Test standards
In:
Total discharge current Itotal:
:
:
:
:
:
:
:
discharge
5kA(
20kA(8/20us)
-40°C~+85°C
10%~90%
92.4mm×7.6mm×97.7mm
2.5mm
DIN 35mm
GB/T 18802.21
IEC 61643-21
Shanghai lightning protection
centre
8/20us)
10kA(8/20us)
Screw connection
2
Lightning protection performance test:
CZLB - □ - □ (□ □)
CZLB s eries
2:2-Wire
3 :3-Wire
Operating voltage
Blank:General type
B:Transmitters
R:Thermocouples
T : Communication signals
EX:Instrinsic safety type
SPD Protected
device
Earthing system
Dimensions
97.7mm
92.4mm
35.0mm
7. 6 m m
6
1
2
4
5
3
Typical application
Terminal or the mounting rail
Note:Put the line to connect SPD grounding and the protected
equipment shell,then If the protected equipment without a grounding
end, only make the surge protective devices connected to earth
2
ground. The grounding wire should adopt the diameter of 2.5mm
cable.When you connected to grounding by terminal or the mounting
rail,the grounding wire should adopt the diameter of cable.
2
4~6mm
National Quality Supervision and Inspection Center for Products of
Process Automation Instrumentation
Cerfication standards:
GB/T 20438.1(IEC 61508-1)
GB/T 20438.2(IEC 61508-2)
GB/T 18802.21(IEC 61643-21)
Functional safety level:SIL3
Safety cerfication
DIN rail
Input
1
2
3
4
5
6
4
5
1
2
Output
DIN rail
Function principle diagram
6
SPD
1
3
2
4
5SPD
6
4
5
1
2
4
5
SPD SPD
DCS
PLC
PCS
FGS
ESD
CZLB- □□ (□3) CZLB- □□ (□3)
CZLB- □ 2)□(□CZLB- □□ (□2)
1
3
2
4
5
1
2
Protected
device
Equipotential bonding(if required)
DIN rail
Protected
device
DIN rail
Equipotential bonding(if required)
DIN rail DIN rail
Protected
device
Protected
device
DCS
PLC
PCS
FGS
ESD
CZLB series general-mode SPD is mainly used to protect the transmitters、
switches、frequency signal、communication equipments、DC power
supply,etc. Two-part design comprising a base part and a protection
module.
Surge
Input
Output

This manual suits for next models

7

Other Chenzhu Surge Protector manuals

Chenzhu GS8567-EX User manual

Chenzhu

Chenzhu GS8567-EX User manual

Chenzhu CZLB-160/440 Series User manual

Chenzhu

Chenzhu CZLB-160/440 Series User manual

Chenzhu CZLB-160/440 Series User manual

Chenzhu

Chenzhu CZLB-160/440 Series User manual

Chenzhu CZLB-EX Series User manual

Chenzhu

Chenzhu CZLB-EX Series User manual

Chenzhu CZLBX-48-S Series User manual

Chenzhu

Chenzhu CZLBX-48-S Series User manual

Chenzhu CZLBX-48 Series User manual

Chenzhu

Chenzhu CZLBX-48 Series User manual

Chenzhu GS8568-EX User manual

Chenzhu

Chenzhu GS8568-EX User manual

Chenzhu CZLB-80/440 Series User manual

Chenzhu

Chenzhu CZLB-80/440 Series User manual

Chenzhu GS8515-EX User manual

Chenzhu

Chenzhu GS8515-EX User manual

Chenzhu GS8558-EX User manual

Chenzhu

Chenzhu GS8558-EX User manual

Popular Surge Protector manuals by other brands

Infinite L-com SRCN-C037 user guide

Infinite

Infinite L-com SRCN-C037 user guide

Arcon 19658 quick start guide

Arcon

Arcon 19658 quick start guide

Panamax MX5102 instructions

Panamax

Panamax MX5102 instructions

Emerson PowerSure PST Specifications

Emerson

Emerson PowerSure PST Specifications

ARRI BALLASTS Brochure & specs

ARRI

ARRI BALLASTS Brochure & specs

Sygonix 1086327 operating instructions

Sygonix

Sygonix 1086327 operating instructions

Philips Resettable SPP7354WA Specifications

Philips

Philips Resettable SPP7354WA Specifications

Clamper DCL SLIM Use and installation guide

Clamper

Clamper DCL SLIM Use and installation guide

Patton electronics 550 Series user manual

Patton electronics

Patton electronics 550 Series user manual

Mersen Surge-Trap XP Series installation instructions

Mersen

Mersen Surge-Trap XP Series installation instructions

Ubiquiti ETH-SP-G2 quick start guide

Ubiquiti

Ubiquiti ETH-SP-G2 quick start guide

PROCET PT-PR01G-10 Quick installation guide

PROCET

PROCET PT-PR01G-10 Quick installation guide

Rocket Fish RF-HTS130 Guide d'installation rapide

Rocket Fish

Rocket Fish RF-HTS130 Guide d'installation rapide

Tripp Lite ISOTEL4ULTRA Specifications

Tripp Lite

Tripp Lite ISOTEL4ULTRA Specifications

JuiceGoose RX Series owner's manual

JuiceGoose

JuiceGoose RX Series owner's manual

Tripp Lite DEU2 TEL Specification sheet

Tripp Lite

Tripp Lite DEU2 TEL Specification sheet

3One data FL485 Quick installation guide

3One data

3One data FL485 Quick installation guide

PRO-TEK PR-91W Quick setup guide

PRO-TEK

PRO-TEK PR-91W Quick setup guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.