Chenzhu CZLBX-48-S Series User manual

CZ.CZLBX-48-S.11(S)E-4.5/15.05
Maintenance
User Manual
危险区
Surge Protective Devices
Caution
Please check whether the product type on the package accords
to the ordering contract;
Read this manual carefully before installation or use. If there is
something unclear ,you can dial our technic support hotline;
Prevent friction, avoid electrostatic;
Users are not allowed to dismantle or repair the SPD otherwise
it will induce malfunction.
Connections
5
4
Add: Building 6, 201 Minyi Road, Caohejing Hi-Tech Park
Songjiang New Industrial Park, Shanghai 201612, P.R. China
Tel : +86-21-64513350 Fax : +86-21-64846984
Email:chenzhu@chenzhu-inst.com
http://www.chenzhu-inst.com
(1).Before using, SPD must have a reliable grounding.
(2).Before using, please check again whether the module's EX-proof rating
accords with the operating ambient, and wiring and polarity are correct. If
working with flameproof transmitter, live action is not allowed.
(3).The products were test strictly before leaving factory. If users find any
abnormalities in the module, please contact the nearest agent or our
company.
(4).In 5 years from the delivery date, if the product works improperly during
normal operation, we will repair or replace it without payment.
CZLBX-48-S series
Note:The wires connect SPD to protected device shoud be as short
as possible, and reduce bending. When use the earthing terminal
connect to ground, please cut the yellow-green lines and keep it
alignment.
Function principle diagram
CZLBX-48-S installation steps:
CZLBX-48-S3 installation steps:
Red
Black
Blue
Yellow Green
Input Output
CZLBX-48-S
Red
Black
Yellow Green
Input Output
CZLBX-48-S3
Earthing of casing
Red
Black
Yellow Green
1
Flameproof hose
3
FOURTH
FIRST FIFTH
Signal lines
CZ LBX- 48- S
CZL BX- 48-S
Surg e Potec tive De vice
Red
Blue
Black
Yellow Green
1
3
3 S
Earthing of casing
CZ LBX- 48- S
S+
1
2
1
2
3
SECOND THIRD
Back hose
Front hose
Flameproof hose
FOURTH
FIRST FIFTH
Signal lines
SECOND THIRD
Back hose Front hose
Installation steps:
(1).Put SPD(with wire) inside the screw thread interface of the protected
equipment.
(2).Connect the red, black, blue and yellow green lines to the correspond-
ing terminal.
(3).Connect shield twisted pair(STP) from control room to terminal 1, 2, 3 of
SPD.
(4).Connect the b .
(5).Connect the f
ack hose of SPD
lameproof hose.
1 2 3
Model designations
CZLBX-48 - □ □
CZLBX s eries SPD
Max. operating voltage
Note:Please tell us when you need a different thread require. Wire
2
size 32/0.2(1.0mmm , 18AWG), length 150mm. Either screw on the
shell or earthing terminal within the instrument can connect to
ground.
National Quality Supervision and Inspection Center for Products of
Process Automation Instrumentation
Cerfication standards:
GB/T 20438.1(IEC 61508-1)
GB/T 20438.2(IEC 61508-2)
GB/T 18802.21(IEC 61643-21)
Functional safety level:SIL3
Safety cerfication
Summarize
(1).No signal attenuation.
(2).Maximum discharge current is 20kA.
(3).Get double certifications which are Intrinsic Safety and Flame proof,
suitable for every occasions.
(4).Choose a variety of thread sizes for your require, suitable for all types of
equipment.
CZLBX-48-S serials SPD are part of field-installed.There are mainly
used to protect device such as transimitters、solenoid valve flowmeter、
RS232、RS485 and other equipments.A main objective is to avoid
damage caused by lightning strikes.The connecting ground by Yellow-
Green wires or .It can be used in 0 zone、
1zone、2zone、ⅡA、ⅡB、ⅡC、T4~T6 hazardous zone.
earthing terminal with the shell
Specification
Dimensions
Explosion-proof parameters
EX-standards:
Ex ia IIC T4~T6 Ga
Ex d IIC T4~T6 Gb
Cerfication standards:
GB3836.1-2010(IEC 60079-0)
GB3836.2-2010(IEC 60079-1)
GB3836.4 -2010(IEC 60079-11)
Explosion-proof parameters:
China National Quality Supervision and Testcentre for Explosion
Protected Electrical Products(CQST).
Rated operating voltage Un (DC):
Max. operating voltage Uc (DC) :
Rated operating current IL:
Rated discharge current In(8/20us):
Max. discharge current Imax(8/20us):
Total discharge current Itotal(8/20us):
Protection level Up(8/20us, line to line):
Protection level Up(8/20us, line to ground):
Response time (line to line):
Response time (line to ground):
Bandwidth(-0.5dB):
Resistance per path:
Leakage current:
Temperature range:
Relative humidity:
Material:
Degree of protection:
Test standards:
Lightning protection performance test:
24V
48V
400mA
10KA
20KA
40KA
60V
600V
1ns
100ns
2MHz
2.2Ω
<2uA
-40℃~+85℃
5%~95%
304 stainless steel
IP65
GB 18802.21
IEC 61643-21
Shanghai lightning protection
Thread Standards:
2、1/2" NPT
3、3/4" NPT
4、Pg 13.5
1、M20×1.5
5、G 1/2"
6、G 3/4"
external thread internal thread
Depth:14mm
45mm
28mm84mm
13mm
11mm13mm 26mm
3:3-Wire
Blank:2-Wire
4:4-Wire
S:Cascade model
Blank:Parallel model
50V 32mA 0.4W
Type
CZLBX-48-S
CZLBX-48-S3 50V 16mA 0.2W
Li
0uF 0mH
0mH
Ci
0uF
Pili
Ui
CZLBX-48- S
Customer can specify the thread standards:
□ M20×1.5(International)
□ 1/2" NPT(American)
□ Pg13.5(German)
□ G1/2"(British)
□ 3/4" NPT(American)
□ G3/4"(British)

This manual suits for next models

2

Other Chenzhu Surge Protector manuals

Chenzhu CZLB-80/440 Series User manual

Chenzhu

Chenzhu CZLB-80/440 Series User manual

Chenzhu CZLB-EX Series User manual

Chenzhu

Chenzhu CZLB-EX Series User manual

Chenzhu CZLB series User manual

Chenzhu

Chenzhu CZLB series User manual

Chenzhu GS8558-EX User manual

Chenzhu

Chenzhu GS8558-EX User manual

Chenzhu GS8567-EX User manual

Chenzhu

Chenzhu GS8567-EX User manual

Chenzhu GS8515-EX User manual

Chenzhu

Chenzhu GS8515-EX User manual

Chenzhu CZLB-160/440 Series User manual

Chenzhu

Chenzhu CZLB-160/440 Series User manual

Chenzhu GS8568-EX User manual

Chenzhu

Chenzhu GS8568-EX User manual

Chenzhu CZLB-160/440 Series User manual

Chenzhu

Chenzhu CZLB-160/440 Series User manual

Chenzhu CZLBX-48 Series User manual

Chenzhu

Chenzhu CZLBX-48 Series User manual

Popular Surge Protector manuals by other brands

M-system MD7LC instruction manual

M-system

M-system MD7LC instruction manual

Projoy Electric PESP-1000 instructions

Projoy Electric

Projoy Electric PESP-1000 instructions

CyberPower P705G user manual

CyberPower

CyberPower P705G user manual

Philips SPP5107C Additional information

Philips

Philips SPP5107C Additional information

Dynex DX-AVSP8 Package Contents

Dynex

Dynex DX-AVSP8 Package Contents

Leviton R Series manual

Leviton

Leviton R Series manual

Panamax MIW-XT installation instructions

Panamax

Panamax MIW-XT installation instructions

Acoustic Research ARHT10 user guide

Acoustic Research

Acoustic Research ARHT10 user guide

M-system MDR2 instruction manual

M-system

M-system MDR2 instruction manual

ZUUM SP6PH user manual

ZUUM

ZUUM SP6PH user manual

Ditek DTK-RM16POC Install instructions

Ditek

Ditek DTK-RM16POC Install instructions

SIMTEC SM20C 1P Installation instruction

SIMTEC

SIMTEC SM20C 1P Installation instruction

Energenie SPF5-C-5 user manual

Energenie

Energenie SPF5-C-5 user manual

ABB POLIM-R operating instructions

ABB

ABB POLIM-R operating instructions

ICM Controls ICM518 Installation, operation & application guide

ICM Controls

ICM Controls ICM518 Installation, operation & application guide

Panamax PM8-AV Specifications

Panamax

Panamax PM8-AV Specifications

P3 International P4400 Kill A Watt Operation manual

P3 International

P3 International P4400 Kill A Watt Operation manual

Panamax PM8-EX instructions

Panamax

Panamax PM8-EX instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.