6 5/16
3 5/8
1/2
7/16 TYP.
11/16 1/2
1 3/8
1 3/16
2
6 1/4
LOWER
LIQUID LEVEL
25/32
DIA.
1 3/8.
2 5/8 MAX.
FLOAT UP
2 13/16
1 15/164 3/16
IF ROD IS INSERTED THRU TOP OF TANK USE
2" HOLE ALLOWANCE FOR LATERAL ROD MOVEMENT.
8"
MIN.
FLOAT
UP
UPPER
LIQUID LEVEL
1" TO 19"
ADJ.
RANGE
30 1/2"
FLOAT
DOWN
27"
MAX
FLOAT
DOWN
5 3/8 DIA
3 3/4
2 3/8
1/2" DIA.
3 3/8
DRAIN
9/16
1/8" NPT
TYP
MAX. LATERAL
MOVEMENT
CF1-C1
Float Control For Open Tanks
Specifications
Pipin
Connections 1/8" NPT
Pressure Ratin 150 psi max.
Temperature
Ratin Water: to 150°F.
Materials In contact with operating fluid:
Nylon Reinforced Delrin®, Stainless Steel,
Monel, with Buna-N®Seals
Float linkage and float rod:
Brass and PVC
Base plate: 316 Stainless Steel
Float: 304 Stainless Steel float
ther materials available:
Stainless Steel rod and stops
Brass rods
Brass base plate
Float 5 3⁄8" diameter.
Float Rod Standard: Two 12" sections of PVC rod
12" extension increments at extra cost. If
maximum temperature exceeds 160°F.
specify Stainless Steel rods. Available at
extra cost
Larger counterweight required if float
rod length exceeds 5' at extra cost
ptional: 24" Stainless Steel rod, with
12" extension increments at extra cost
Larger counterweight required if float rod
length exceeds 2' at extra cost
Level Differential 1" min to 18" max. with PVC rod
1" min to 40" max. with Stainless Steel rod
Operatin Fluids Clean liquids or gases compatible with
specified materials.
Shippin Wei ht 12 lbs.
• Accurate Liquid Level Control
• Fully Hydraulic Operation
• Simple Desi n, Easy Maintenance
• No Lubrication Necessary
• No Gears, No Mechanical Linka e Between
Valve and Control
The Cla-Val Model CF1-C1 Float Control is a float-actuated, multi-
port pilot control which provides non-modulating, two-position, on-off
operation. It is used primarily to operate remotely located Cla-Val
valves requiring three-way or four-way pilot valve operation.
Designed for used in open tanks, this control operates on a minimum
level change of approximately one inch. Maximum level change is
nineteen inches. This level adjustment can be located up to 111⁄2feet
from the control by adding float rod extensions.
The float moves freely on the float rod. n rising liquid level, the float
contacts the upper stop and lifts the float linkage to the "UP" position.
As the liquid level lowers, the control stays in the "UP" position until
the float contacts the lower stop. The control then shifts to the
"D WN" position.
Dimensions (In Inches) M UNT BRACKET A MINIMUM
F 1-1/2" FR M TANK WALL
F R FL AT CLEARANCE.
M DEL