1.1 Warnings
All installations must be in accordance
with the regulations. These instructions
must be handed to the user on comple-
tion of the installation. Installers and ser-
vice engineers must be able to demon-
strate competence and be suitably
qualified in accordance with the regula-
tions. To ensure continued and safe op-
eration it is recommended that the ap-
pliance is serviced annually. The air cur-
tain outlet/inlet grille must not be ob-
structed during use. Any modifications
made to the unit not approved by Con-
sort will void manufacturer’s warranty
and potentially create a hazard. The ap-
pliance is NOT intended for use by per-
sons (including children) with reduced
physical, sensory or mental capabilities
or lack of experience or knowledge un-
less they have been given instruction
concerning use of the appliance by a
person responsible for their safety. Chil-
dren should be supervised to ensure that
they do not play with the appliance.
Parts of the heater can become very hot
when in operation and cause burns. The
heater is not equipped with a room ther-
mostat and should not be used in small
rooms as it will overheat.
1.2 Health and Safety
Please read these instructions thoroughly be-
fore installing the appliance. Sole liability
rests with the installer to ensure that all site
safety procedures are adhered to during in-
stallation. Sole liability rests with the installer
to ensure that protective safety wear such
as hand, eye, ear and head protection is
used during installation of the product. En-
sure that all anchoring points are suitable for
the weight of the appliance.
1.3 Electrical Supply
This heater must be permanently connected
to the electricity supply via an all pole switch
having 3mm gap on each pole. There are
no exceptions.
All units must be wired in accordance with
I.E.E. regulations for the Electrical Equip-
ment of Buildings.
BMS control, time switches and door inter-
locks can be installed at the discretion and
responsibility of the installer
1.4 Location
All units should be installed directly over
the door opening. It is recommended that
the air curtain is installed on the inside of
the building.
Care must be taken to allow complete
free air movement into the inlet grilles of
the unit to ensure correct working opera-
tion of the air curtain. The discharge open-
ing should be as close to the top of the
door as possible and cover the entire door
width.
Units can be mounted adjacent to each
other to cover the full door opening across
wider entrances.
1.5 Clearance Distance
It is recommended that a minimum clear-
ance of 50mm is allowed above the heat-
er. The clearance allows for cable entry
and additional air inlet. It also prevents sur-
faces overheating.
The minimum mounting height (floor to
grille) is 2m. The maximum mounting height
is 3.4m.
1.6 Standards
The heater conforms to the following
standards
Electrical Equipment (Safety) Regulations
2016 SI. 2016 1101
Electromagnetic Compatibility Regulations
2016 SI. 2016 No. 1091
Radio Equipment Regulations 2017 SI.
2017 No. 1206
The Ecodesign for Energy Related Products
and Energy Information (Amendment) (EU
Exit)Regulations 2019. SI. 2010 2617
The Restriction of use of Certain Hazardous
Substances. SI. 2012 No. 3032