Cleveland
™
Project ________________________________
Item __________________________________
Quantity _______________________________
FCSI Section ____________________________
Approval _______________________________
Date __________________________________
1333 East 179 St.,
Cleveland, Ohio, U.S.A. 44110
Tel: 1-216-481-4900
Fax: 1-216-481-3782
Web Site: www.ClevelandRange.com
Email: Steam@ClevelandRange.com
STEAMCRA T®GENERATOR STYLE
HIGH SPEED CONVECTION STEAMERS
Stea Craft ®Power 10
TWO COMPARTMENT FLOOR MODEL DESIGN
GAS STEAM GENERATORS
240M BTU,
24" WIDE MODULAR DESIGN
MODEL: 24-CGP-10
Cleveland Standard Features
IIPressureless cooking permits doors to be opened during oper-
ation. Capacity for up to ten 12" x 20" x 21⁄2" deep Cafeteria
pans, five each compartment.
IIExclusive PowerPak Gas Steam Generator:
High Efficiency orced Air (Power Burner) Gas ired Boiler
has 240,000 Btu's Input, produces 180 Ibs of steam per hour.
10-12 PSI operating generator pressure. Steam generator is
equipped with a High-Limit Pressure Safety Switch, 15 psi
Safety Valve and a Secondary Low Water Shut Off Safety
standard. ully insulated rear mounted steam generator. Gas
Pressure Regulator and Control Valve included standard.
IIBoiler Descaling Port Connection: Inlet and Outlet descal-
ing port connections for use with the Descaling Pump
IIInstant Steam Stand By Mode: Holds generator at a
steaming temperature. Allows unit to start steaming instantly.
IIDurable 14 Gauge, Stainless Steel Construction: or
compartment door, cavity and cabinet frame.
IITwo 60 Mechanical Timers with ON/O Main Power
Switch with a Heat On, Low Water Indicator Lights and High
Temperature Safety Light and Shut-off (Reset Light).
IIMain Power On/Off Switch: Controls the electric power and
automatically fills the generator with water. A separate Steam
Switch ignites the burners via a fully automatic Electronic
(pilotless) Spark Ignition.
IIExclusive Steam Cooking Distribution System:
Exclusive Brass Steam Jets produce a high velocity
convection steam without fans. Coved Corner design in
cooking compartment distributes heat evenly, easy to clean.
Creased top & bottom enhance drainage. Cold Water
Condenser for each compartment maintains a dry steam. ully
insulated cooking compartment for thermal efficiency.
Removable Stainless Steel Slide Racks. Reversible Door
Gasket.
IIAutomatic Boiler Drain: Contains a “Water Jet” Spray Rinse
Drain Cleaning Cycle to keep drain clear.
IIExclusive Automatic Float for Water evel Control:
Separate from the generator for easy access, contains a high
velocity rinse cycle to eliminate mineral buildup.
IIExclusive “Cool to the Touch” Two-Piece Compartment
Door Design: ree floating inner door with reversible gasket
provides an air tight seal. Stainless Steel Slam/Latch Door
mechanism for reliability.
IICondensate Drip Trough: Provided under lower
compartment door to collect condensate.
IIeft Hand Door Hinging: Compartment Doors hinged on the
left, controls on the right.
IINSF Certified 6˝ Stainless Steel egs with adjustable
flanged feet for a one inch level adjustment.
IICSD-1 Compliant
Shall be CLEVELAND,
SteamCraftPower 10
, two compartments,
Floor Model Steamer, Model 24-CGP-10. Sin le, lar e capacity
Gas-fired Pressure Steam Generator, 240M BTU input. Exclusive
Automatic Water Level Float desi n. Steam Generator with
Automatic Water Fill on start up, Automatic Generator Blowdown,
Electronic Spark I nition and Generator Standby for instant steam.
Choice of Compartment Controls, Manual By Pass Operation
Mode. Exclusive Cold Water Condenser desi n.
Options & Accessories
ËBoiler Descaling Pump Kit (107142)
ËRight hand Door Hinging, Controls on Right (DHR)
ËElectronic Timer with Compensating Load eature (ETC)
ËON/O Steam Switch for compartment controls (MC)
ËPower Take Off Kit (GPTO-1O)
ËKettle Interconnecting Kit (IMK-)
ËCompartment Door Steam Shut Off Switch (SCS)
ËCafeteria Pans in depths of 1", 2
1
⁄
2
", 4" and 6"
ËType of gas other than natural
ËDissolve
®
Descale Solution, 6 one gallon container w/quart
markings (106174)
ËWater ilters
ËCorrectional Packages
Short For Specifications
SECT. IV PAGE 19
1007