  9. Cole Parmer Geno/Grinder HG-600 User manual

Cole Parmer Geno/Grinder HG-600 User manual

Other Cole Parmer Laboratory Equipment manuals

Cole Parmer CB-200 Series User manual

Cole Parmer

Cole Parmer CB-200 Series User manual

Cole Parmer Stuart SP152B User manual

Cole Parmer

Cole Parmer Stuart SP152B User manual

Cole Parmer FSB-200 Series User manual

Cole Parmer

Cole Parmer FSB-200 Series User manual

Cole Parmer Colony Counter 14312-00 User manual

Cole Parmer

Cole Parmer Colony Counter 14312-00 User manual

Cole Parmer TR-200 Series User manual

Cole Parmer

Cole Parmer TR-200 Series User manual

Cole Parmer Stuart SC6PLUS User manual

Cole Parmer

Cole Parmer Stuart SC6PLUS User manual

Cole Parmer HG-600 Geno/Grinder 2010 User manual

Cole Parmer

Cole Parmer HG-600 Geno/Grinder 2010 User manual

Cole Parmer SH-200 Series User manual

Cole Parmer

Cole Parmer SH-200 Series User manual

Cole Parmer ShatterBox SM-300 User manual

Cole Parmer

Cole Parmer ShatterBox SM-300 User manual

Cole Parmer RHC-400 Mounting instructions

Cole Parmer

Cole Parmer RHC-400 Mounting instructions

Cole Parmer PCRmax Alpha Cycler 1 User manual

Cole Parmer

Cole Parmer PCRmax Alpha Cycler 1 User manual

Cole Parmer MP-200 Series User manual

Cole Parmer

Cole Parmer MP-200 Series User manual

Cole Parmer Julabo 200F User manual

Cole Parmer

Cole Parmer Julabo 200F User manual

Cole Parmer GenoLyte HG-250 User manual

Cole Parmer

Cole Parmer GenoLyte HG-250 User manual

Cole Parmer RV-400 Series User manual

Cole Parmer

Cole Parmer RV-400 Series User manual

Cole Parmer RS-200 Series User manual

Cole Parmer

Cole Parmer RS-200 Series User manual

Cole Parmer Stuart SM27 User manual

Cole Parmer

Cole Parmer Stuart SM27 User manual

Cole Parmer EH-200 Series User manual

Cole Parmer

Cole Parmer EH-200 Series User manual

Cole Parmer ST-100 Series User manual

Cole Parmer

Cole Parmer ST-100 Series User manual

Cole Parmer WBS-300 Series User manual

Cole Parmer

Cole Parmer WBS-300 Series User manual

Cole Parmer HO-400 Series User manual

Cole Parmer

Cole Parmer HO-400 Series User manual

Cole Parmer BM-600 User manual

Cole Parmer

Cole Parmer BM-600 User manual

Cole Parmer StableTemp 03405-00 User manual

Cole Parmer

Cole Parmer StableTemp 03405-00 User manual

Cole Parmer CG-500 User manual

Cole Parmer

Cole Parmer CG-500 User manual

Popular Laboratory Equipment manuals by other brands

Qiagen DML 3000 user manual

Qiagen

Qiagen DML 3000 user manual

Queensgate NANOSCAN OP400 Quick start instructions

Queensgate

Queensgate NANOSCAN OP400 Quick start instructions

Conviron GEN1000-GE Operator's manual

Conviron

Conviron GEN1000-GE Operator's manual

Parr Instrument 4560 Operating instructions manual

Parr Instrument

Parr Instrument 4560 Operating instructions manual

IKA IC control operating instructions

IKA

IKA IC control operating instructions

Integra DOSE IT operating instructions

Integra

Integra DOSE IT operating instructions

Agilent Technologies 5800 ICP-OES user guide

Agilent Technologies

Agilent Technologies 5800 ICP-OES user guide

Endress+Hauser Cleanfit CPA875 operating instructions

Endress+Hauser

Endress+Hauser Cleanfit CPA875 operating instructions

NI PXI-5422 CALIBRATION PROCEDURE

NI

NI PXI-5422 CALIBRATION PROCEDURE

Collomix Aqix operating instructions

Collomix

Collomix Aqix operating instructions

SPEX SamplePrep 6875 Freezer/Mill Series operating manual

SPEX SamplePrep

SPEX SamplePrep 6875 Freezer/Mill Series operating manual

Ocean Insight FLAME-NIR+ Installation and operation manual

Ocean Insight

Ocean Insight FLAME-NIR+ Installation and operation manual

Parker ALIGN-MG-NA Installation, operation and maintenance manual

Parker

Parker ALIGN-MG-NA Installation, operation and maintenance manual

BD 644787 user guide

BD

BD 644787 user guide

DENTAURUM Compact Megaplus Instructions for use

DENTAURUM

DENTAURUM Compact Megaplus Instructions for use

Biuged Laboratory Instruments BGD 626 instruction manual

Biuged Laboratory Instruments

Biuged Laboratory Instruments BGD 626 instruction manual

VWR SAS Super IAQ instruction manual

VWR

VWR SAS Super IAQ instruction manual

illumina MiSeqDx reference guide

illumina

illumina MiSeqDx reference guide

https://manuals.online logo
https://manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2026 Manuals.Online. All Rights Reserved.

1300-87055QSG-1G, REV 4
HG-600 Geno/Grinder® 2010
Tissue and Cell Lyser for Biological Applications
Quick Start Guide
For 115V (04500-17) and 230V (04576-84)
Step 1. Connect the powercord to the AC Inlet located in the back of the unit. Do not plug mill into
GFCI outlet. Power On the 2010 GG. “Please Wait”appears on the screen during start-up as the
software loads followed by the Home Screen.
Step 2. Load samples into the clamp (titer plates or vials). When using 4 or 6 titer plates, place a nesting
tray between them. If using vials (2ml or 5ml), vial holders can be stacked to maximize throughput.
Step 3. Position the clamp lid above the threaded rod with the guide on the upright at the rear of the clamp,
press and hold button on the locking knob while sliding down the threaded rod.
Step 4. Turn knob to tighten (finger tight) and check that the button has popped out.
How To Operate HG-600 Geno/Grinder®
Set up the Geno/Grinder® in a well ventilated,
unconfined space. The unit should be operated on a
flat, hard, stable benchtop due to the vigorous motion
and vibration generated during operation.
To install the clamp, use the 3/16 in Allen wrench
(supplied with power cord and manual). Raise lid and
attach clamp using the lock washers and bolts to the
top of the shaft.
Secure clamp base to shaft
using bolts and lock washers
supplied with clamp.
Upright must be
at rear of unit.
Lid
2012
Clamp
Touchscreen
Display
AC Inlet
Do not plug into GFCI outlet
(Ground Fault Circuit Interrupter)
Locking
Knob
On/Off
button
Stacking Titer Plates
Double-sided
nesting tray
Single-sided
nesting tray
(bottom only)
B) Turn knob clockwise to
tighten (finger tight).
C) Make sure that vial
holders
are secure
and cannot be
moved from side
to side.
A) Slide the clamp lid on top
of the vials. Screw down
the locking knob on the
threaded rod.
1300-87055QSG-1G, REV 4 Cole-Parmer®
THE TOUCHSCREEN DISPLAY
Our Application Specialists at Cole-Parmer are here to help with advice on accessories and grinding protocols.
Call USA Tel: +1.800.323.4340 or techinfo@coleparmer.com
Important: Never run the Geno/Grinder with the 2012 clamp not screw-tightened or with titer plates held
loosely in the clamp. Damage and leakage will result. When processing samples in only one titer plate, load
an empty titer plate on the other half of the clamp assembly. Similarly, if less than a full holder of vials is
used, be sure to place an equal number of vials on the front and rear of the clamp, to ensure that the load is
balanced and tightly clamped. Empty vials can be used as place holders if an uneven number of samples are
run. The maximum recommended total sample load in the clamp assembly is 4 lb. (1.8 kg). The total sample
load includes sample, vials (or titer plates), grinding media, holders (or cryo-blocks), and nesting trays. For
sample loads exceeding 2.0 lb. (0.9 kg), the maximum recommended operating rate is 1500 rpm. Sample
loads less than 2.0 lb. can be run at rates up to the maximum of 1750 rpm. Dynamic loads greater than 2 lb.
can create a rate error. When stacking 4 or 6 titer plates, do not add more than five 4 mm steel balls to a
single titer plate well.
From the Home Screen the
Control Panel, Saved Protocols,
and Run History, and Settings
can be accessed by the user.
Programmable operating
commands through a series of
touchscreen displays. USB to
imports/export saved protocols,
run history, diagnostic data, or
upgrade the system software.
Administrative lockout (passcode)
which allows Lab Manager to
restrict user access to specific
protocols. Default code is 0000.
On the Control Panel, runtime
parameters can be set as well
as stored or recalled.
A pop-up keyboard is activated
when editing, adding, or saving
a protocol.
From the Settings Screen the
Diagnostics, System Settings
and Administrative lockout are
accessed.