Continental Refrigerator ContiPressureCheck Series Reference guide

GB
/USA Hand-held tool
ContiPressureCheck™

GB /USA Hand-held tool brief instructions................................................................................................3
Homologation/Kanada
Canada, Industry Canada (IC) Notices
“This device complies with Industry Canada license-exempt RSS standard(s). Operation is
subject to the following two conditions:
(1) this device may not cause interference,
and
(2) this device must accept any interference, including interference that may cause undesi-
red operation of the device.“
Canada, avis d‘Industry Canada (IC)
“Le présent appareil est conforme aux CNR d‘Industrie Canada applicables aux appareils
radio exempts de licence. L‘exploitation est autorisée aux deux conditions suivantes :
(1) l‘appareil ne doit pas produire de brouillage,
et
(2) l‘utilisateur de l‘appareil doit accepter tout brouillage radioélectrique subi, même si le
brouillage est susceptible d‘en compromettre le fonctionnement.“
This Class B digital apparatus complies with Canadian ICES003 plus the RESGEN, 003
(201012) and RSS210, issue 8 (201012).

3CPC hand-held tool
USA
General
►These brief instructions are only intended to illustrate the most im-
portant operating steps and functions of the hand-held tool and are
a supplement to the actual user manual. Make sure you also read the
detailed user manual.
Tool overview
6
2 3 4
5
1
Pos Bezeichnung Task
1Screen Menu display.
2ESC key
Exit a sub-menu.
Scroll back in some menus.
Press the ESC key for 3 s.
= cancel an action.
3Arrow keys Navigate within a menu.
Set values
4Return key Conirm selection.
Acknowledge a message.
5ON/OFF key Switch the hand-held tool ON/OFF.
6Antenna Antenna for responding to the tire sensors.

4CPC hand-held tool
USA
Charging the hand-held tool
►Before using the tool for the irst time, charge the tool for at least 12
hours according to the charging instructions.
►According to the the charging instructions, the tool must be charged
for at least 12 hours once a month.
Switch on the hand-held tool.
Remove the cover for the connection socket of the power adapter.
Connect the connecting cable of the power adapter and plug the power adapter
into a mains socket.
After approx. 10 seconds, the tool switches itself o automatically
and a charging symbol is displayed on the screen.
►If an adapter or a charging symbol
is not displayed during charging, the tool is not being charged
suiciently.
►Only use the power adapter supplied.
►The charging process takes approx. 7 hours.
►For accreditation reasons, the hand-held tool may not be operated
when the mains adapter is connected.

5CPC hand-held tool
USA
Menu control
Calling a menu function
Use the arrow keys to select the desired menu item.
Conirm selection with the Return key and call up the menu item.
If the menu includes submenus, use the arrow keys to select the desired menu
item and conirm selection with the Return key .
Press the ESC key to return to the previous menu level.
Press the ESC key for 3 s to cancel an action.
Changing a selection
Use the arrow keys to select between the settings/options.
Conirm selection with the Return key .
Setting the language
The menu begins with the main setting in English. Select the desired language by fol-
lowing the menu path: "SETUP/LANGUAGE".
►If no SD memory card is inserted in the hand-held tool, the memory
card is either defective or the software was not correctly installed, only
"ENGLISH" is available.

6CPC hand-held tool
USA
Menu structure
Tire sensor
Check sensor Read the data of the tire sensor.
Activate Sensor Switch sensor to operating mode.
Deactivate Sensor Switch o cyclic transmission (power save mode).
Actions on Tire
Show Display last received tire sensor data.
Check Read the data of the tire sensor.
Activate Switch sensor to operating mode.
Deactivate Switch o cyclic transmission (power save mode).
Check all tires Interrogate tire sensor data for vehicles without CCU and DSP.
Sniing Tool Special function:
Tool receives all tire sensors within reception range.
Trigger Tool
Special function:
The transmission power of the interrogating signal can be
varied accordingly.
Installation
New Installation Create a new CPC system coniguration.
Resume
installation Continue an interrupted CPC system coniguration.
Test drive
Check the reception quality if the CPC systems installed.
Modiication
Modify Installation
Check Installation Check the existing coniguration parameters.
Modify Parameters Change the already deined coniguration parameters.
Modify Sensor IDs Renew assignment of the sensor IDs.
Activate CPC Activate the CPC system.
Deactivate CPC Deactivate the CPC systems temporarily.
Diagnosis
DTC (error code)
Global DTCs Display general error messages.
Tire-related DTCs Display of error messages that refer to a speciic tire.
Erase all DTCs Delete all pending error messages.
Save DTCs Save all pending error messages.

7CPC hand-held tool
USA
Diagnosis
SW Update
CCU Update the software of the CCU (control unit).
DSP Update the software of the display.
CSW Update the software of the switching module.
Connection to the PC Communicate with the SD card via a USB cable.
Setup
Language
Set the desired menu language of the hand-held tool.
Available languages: Czech, Danish, German, English, Spanish,
French, Italian, Hungarian, Dutch, Norwegian, Polish, Portugue-
se, Rumanian, Slovak, Finnish, Swedish, Turkish
Measurement unit
Pressure Unit for displaying the pressure values (bar / psi).
Temperature Unit for displaying the temperature values (°C / °F).
Sound setup
Sound Select the desired setting for sound (ON / OFF).
Vibration Select the desired setting for vibration (ON / OFF).
Tool Properties
Automatic
power-o
Setting for automatic switch-o of the hand-held tool (o, 5
min, 10 min, 15 min).
Date/time Setting for date and time in the the hand-held tool.
(Date format can be selected).
Use date Should the date and time be used for log iles (yes / no)?
Release Display of the hand-held tool software version.

8CPC hand-held tool
USA
SD memory card
Slot for SD memory card
The SD memory card is supplied with the hand-held tool by default.
►If no SD memory card is inserted in the hand-held tool, the memory
card is either defective or the software was not correctly installed, only
"ENGLISH" is available.
►Storing of DTCs and log iles is not possible without an SD memory card.
Handling data on the SD memory card
Access to the SD memory card takes place via a USB connection to the PC as described
under "Connection to the PC".
►Failure to observe the speciications on handling iles on the SD memo-
ry card can lead to malfunction and total failure of the hand-held tool or
the CPC system.
►The directory structure and naming as well as the content of the iles
may not be changed
►Do not erase any iles on the memory card!
The log iles ("\REPORT") are an exception and can be copied and dele-
ted without aecting the system.
Directory structure
SD memory card
CONFIG Coniguration iles for the hand-held tool
LANGUAGE Language iles for the hand-held tool
REPORT Log iles
TEMP Temporary iles.
UPDATE Files for updating the software of CPC components
If the hand-held tool is to be connected to a PC via the USB cable and PC,
only "English" is available:
►Follow the menu path "Diagnosis/Connection to PC" to connect the
hand-held tool to the PC.

9CPC hand-held tool
USA
Log iles
The log iles that are created when working with the hand-held tool are stored in the
"REPORT" directory on the SD memory card (see Directory structure).
A unique name is automatically assigned to identify the individual log iles. This is
made up as follows:
File name?
Vehicle name Code letter for the menu function
executed
Date Time
(Serial no.)*(Consecutive
no.)*
Max. 19 charac-
ters
T= Test drive / D = DTC / I = Installation
/ V = "Check all tires"
YYYYMMDD hhmmss
(XXXXXX)*(ZZZZ)*
* Serial no. and consecutive no. only appear when use of date/time is deactivated
in the menu Setup - Tool Properties - Date date.
►A software program is oered for evaluating the log iles (see
www.contipressurecheck.com).
Handling the tool
In order to communicate with the tire sensors, the hand-held tool is equipped with an
antenna. The following describes the procedure for communication that is used in all
menus.
►Always hold the antenna in the direction of the sensor in order to ensu-
re the best possible communication.
►If sound and/or vibration was switched during setup, a corresponding
signal is emitted after successful reading.
►The read operation takes place via 3 steps with increasing transmission
power. If communication beyond that is still not possible, the process is
aborted.

10 CPC hand-held tool
USA
Reading an accessible sensor
In the event that the sensor is easily accessible, proceed as follows for reading:
Hold the hand-held tool with antenna directly in
front of the sensor as illustrated.
Fetching a sensor itted in the tire
When fetching the tire sensors, the following is displayed:
PWR: XX%
1/3
In the animation, the marker point moves
along the side wall in a speciied direction
and at a speciied speed.
Hold the hand-held tool with antenna in front of the
side wall of the tire as illustrated. The marker point is the
starting point in the display.
Move the hand-held tool along the side wall of the tire at
the same speed of the animation.
New Installation of a CPC system
When reinstalling a CPC system, follow the instructions in the user manual on the CD or
at www.contipressurecheck.com.
►Before initializing the CPC system, make sure that all tire sensors are
activated.

GB /USA
Disposal
This tool may not be disposed of in the domestic refuse.
The hand-held tool contains a lithium battery that is cast into the housing and
cannot be replaced. After reaching the end of its service life, the tool must
be disposed of in accordance with all current local, regional and national
laws and regulations. The tool can be taken to collection points for electrical/
electronic component or the CPC sales partner. It can also be sent back to the
following CPC collection point. Address of the central CPC collection point:
Continental Trading GmbH
„Abteilung Entsorgung“
VDOStraße 1,
Gebäude B14,
64832 Babenhausen
Germany

RF Testing Device
Tool-No. 040072
KA_HHT_0214_A1_EN
Continental Reifen Deutschland GmbH
Büttnerstraße25
30165 Hanover
Germany
www.contipressurecheck.com
www.continental-truck-tires.com
www.continental-corporation.com
Table of contents
Other Continental Refrigerator Measuring Instrument manuals

Continental Refrigerator
Continental Refrigerator ContiPressureCheck User manual

Continental Refrigerator
Continental Refrigerator DTCO 1381 User manual

Continental Refrigerator
Continental Refrigerator ContiPressureCheck Reference guide

Continental Refrigerator
Continental Refrigerator TPMS Go User manual

Continental Refrigerator
Continental Refrigerator ContiPressureCheck Reference guide