manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Contrel
  6. •
  7. Measuring Instrument
  8. •
  9. Contrel ELRC-1 User manual

Contrel ELRC-1 User manual

Other Contrel Measuring Instrument manuals

Contrel EMA-90N User manual

Contrel

Contrel EMA-90N User manual

Contrel EMM-D4h User manual

Contrel

Contrel EMM-D4h User manual

Contrel RI-R44-V User manual

Contrel

Contrel RI-R44-V User manual

Contrel EMA-D6 User manual

Contrel

Contrel EMA-D6 User manual

Contrel EMA-D9 User manual

Contrel

Contrel EMA-D9 User manual

Contrel EMC Series User manual

Contrel

Contrel EMC Series User manual

Contrel RMS-12 User manual

Contrel

Contrel RMS-12 User manual

Contrel EMA11 User manual

Contrel

Contrel EMA11 User manual

Contrel EMS-96 User manual

Contrel

Contrel EMS-96 User manual

Contrel RI-SM User manual

Contrel

Contrel RI-SM User manual

Contrel EMM-m3-VA User manual

Contrel

Contrel EMM-m3-VA User manual

Contrel CTT8 User manual

Contrel

Contrel CTT8 User manual

Contrel EMA90 User manual

Contrel

Contrel EMA90 User manual

Contrel CTT8 User manual

Contrel

Contrel CTT8 User manual

Contrel EMU-3ea User manual

Contrel

Contrel EMU-3ea User manual

Contrel EMM-4h User manual

Contrel

Contrel EMM-4h User manual

Popular Measuring Instrument manuals by other brands

Powerfix Profi 278296 Operation and safety notes

Powerfix Profi

Powerfix Profi 278296 Operation and safety notes

Test Equipment Depot GVT-427B user manual

Test Equipment Depot

Test Equipment Depot GVT-427B user manual

Fieldpiece ACH Operator's manual

Fieldpiece

Fieldpiece ACH Operator's manual

FLYSURFER VIRON3 user manual

FLYSURFER

FLYSURFER VIRON3 user manual

GMW TG uni 1 operating manual

GMW

GMW TG uni 1 operating manual

Downeaster Wind & Weather Medallion Series instruction manual

Downeaster

Downeaster Wind & Weather Medallion Series instruction manual

Hanna Instruments HI96725C instruction manual

Hanna Instruments

Hanna Instruments HI96725C instruction manual

Nokeval KMR260 quick guide

Nokeval

Nokeval KMR260 quick guide

HOKUYO AUTOMATIC UBG-05LN instruction manual

HOKUYO AUTOMATIC

HOKUYO AUTOMATIC UBG-05LN instruction manual

Fluke 96000 Series Operator's manual

Fluke

Fluke 96000 Series Operator's manual

Test Products International SP565 user manual

Test Products International

Test Products International SP565 user manual

General Sleep Zmachine Insight+ DT-200 Service manual

General Sleep

General Sleep Zmachine Insight+ DT-200 Service manual

Sensa Core Lacto Spark user manual

Sensa Core

Sensa Core Lacto Spark user manual

VOLTCRAFT UTS-1980 operating instructions

VOLTCRAFT

VOLTCRAFT UTS-1980 operating instructions

EBCHQ 94915 Operation manual

EBCHQ

EBCHQ 94915 Operation manual

Balluff BIP LD2-T017-01-EP-S4 Series user guide

Balluff

Balluff BIP LD2-T017-01-EP-S4 Series user guide

Pulsar IMP Lite Series instruction manual

Pulsar

Pulsar IMP Lite Series instruction manual

ETCR 6800 user manual

ETCR

ETCR 6800 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

ELRC-1 IM250-IUEDF v1.4 1 / 2
manuale istruzioni - instruction manual – manual de instrucciones – betriebsanleitung - manuel d'instruction
1
2
3
4
5
8
9
67
10
a
b
c
d
MANUALE ISTRUZIONI - INSTRUCTION MANUAL - MANUAL DE INSTRUCCIONES -
BETRIEBSANLEITUNG - MANUEL D'INSTRUCTION
IM250-IUEDF v1.4
ELRC-1
Relè differenziale di terra
Earth Leakage Relay
Relé diferencial
Erdschlussrelais
Relais différentiel de défaut à la terre
IT
legenda
1) Potenziometro di regolazione tempo d’intervento;
2) Potenziometro di regolazione corrente di guasto a terra;
3) Commutatore a slitta per la scelta delle costanti:
-riarmo automatico con commutatore (a) in posizione 1;
-scelta costante per taratura di tempo:
K = 1 commutatore (b) in posizione 0;
K = 10 commutatore (b) in posizione 1;
-scelta costante per taratura di corrente:
K = 0.1 per commutatori (c-d) in posizione 0;
K = 1 per commutatore (c) in posizione 1 e commutatore (d) in posizione 0;
K = 10 per commutatori (c) e (d) in posizione 1;
4) Pulsante per prova;
5) Pulsante per riarmo manuale;
6) Lampada di segnalazione presenza di alimentazione ausiliaria (LED verde);
7) Lampada di segnalazione di relè intervenuto (LED rosso);
8) Morsetti per alimentazione ausiliaria;
9) Morsetti di uscita relè;
IMPORTANTE: Nella versione con relé eccitato (sicurezza positiva) la bobina
(Ba) deve essere connessa hai morsetti 4-5.
UK
legend
1) Delay adjustment potentiometer;
2) Tripping current adjustment potentiometer;
3) Sliding contact switch for selection of constants:
- automatic resetting with switch (a) in pos.1;
- selection of constant for delay rating:
K = 1 for switch (b) in pos. 0;
K = 10 for switch (b) in pos. 1;
- selection of constant for current rating:
K = 0.1 for switch (c) and (d) in pos. 0;
K = 1 for switch (c) in pos. 1 and switch (d) in pos. 0;
K = 10 for switches (c) and (d) in pos. 1;
4) Test push-button;
5) Manual reset push-button;
6) Signalling lamp of existing auxiliary voltage supply (green LED);
7) Signalling lamp of tripped relay (red led);
8) Terminals for auxiliary supply;
9) Relay output terminals;
IMPORTANT: In the version with excited relay (fail safe), the coil (Ba) must
be connected at the terminal 4-5.
ES
legenda
1) Potenciómetro de regulación tiempo de disparo.
2) Potenciómetro de regulación intensidad de fuga.
3) Micro interruptor para la elección de las constantes:
- Rejuste con interruptor automático (a) en pos.1
- tiempo:
K = 1 para micro (a) en posición 0;
K=10 para micro(a) en posición 1;
- Intensidad:
K=0,1 para micro (b-c) en posición 0;
K= 1 para micro(b) en posición 1 y (c) en posición 0;
K=10 para micro (c-b) en posición 1
4) Pulsador de prueba.
5) Pulsador de rearme manual.
6) Lámpara de señalización presencia de tensión auxiliar (LED verde).
7) Lámpara de señalización de relé disparado (LED rojo).
8) Terminales de alimentación auxiliar;
9) Terminales terminales de salida Relé
IMPORTANTE: En la version con relé excitado (seguridad positiva) la
bobina (Ba) debe estar conectada a los terminales 4 y 5.
DE
legende
1) Potentiometer für die Einstellung der Auslösezeit.
2) Potentiometer für die Einstellung des Auslösestroms.
3) Mikroschalter für die Auswahl der Konstante:
- Automatischen Zurücksetzen mit Mikroschalter (a) auf Position 1;
- Zeit:
K = 1 mit Mikroschalter (b) auf Position 0;
K=10 mit Mikroschalter (b) auf Position 1;
- Strom:
K=0,1 mit Mikroschalter (c-d) auf Position 0;
K= 1 mit Mikroschalter (c) auf Position 1und (d) auf Position 0;
K=10 mit Mikroschalter (c-d) auf Position 1
4) Testdrucktaste.
5) Manuelle Reset-Taste.
6) Signallampe für Hilfsspannung (grüne LED-Anzeige).
7) Signallampe für ausgelöstes Relais (rote LED-Anzeige).
8) Klemmen für Hilfsspannung
9) Klemmen für Ausgangsrelais
WICHTIG: In der Version mit erregtem Relais (Fehlersicherheit), die Spule
(BA) mit den Klemmen 4-5 verbinden.
FR
légende
1) Potentiomètre de réglage du temps d’intervention;
2) Potentiomètre de réglage de la seuil de courant d’intervention;
3) Commutateurs a coulisse pour la sélection des constants:
-réarmement automatique avec commutateur (a) en pos. 1;
- sélection de la constante pour réglage de temps:
K = 1 pour commutateur (b) en position 0;
K = 10 pour commutateur (b) en position 1;
- sélection de la constante pour réglage de la courant:
K = 0.1 pour commutateurs (c-d) en position 0;
K = 1 pour commutateur (c) en pos. 1 et (d) en pos. 0;
K = 10 pour commutateurs (c-d) en pos. 1;
4) Bouton-poussoir d’essai;
5) Bouton-poussoir de réarmement;
6) Lampe de signalisation de la tension d’alimentation auxiliaire (LED VERT);
7) Lampe de signalisation d’intervention (LED ROUGE);
8) Terminaux pour l’alimentation auxiliaire
9) Terminaux sortie relais
IMPORTANT: En version relais excite (positif), la bobine de décrochage
(Ba) doit etre connectée aux bornes 4-5.
ELRC-1 IM250-IUEDF v1.4 2 / 2
manuale istruzioni - instruction manual – manual de instrucciones – betriebsanleitung - manuel d'instruction