CORNING LSE 6770 User manual

Model No. 6770
Corning®LSE™
Mini Microcentrifuge
Instruction Manual
About This Manual
This manual is designed to assist in the optimal usage of the Corning LSE Mini Microcentrifuge
(Model No. 6770). The manual is available in English, French, German, Italian, Portuguese, and
Spanish at www.corning.com/lifesciences.
Register your product warranty online at
www.corning.com/lifesciences/warranty.
For a listing of trademarks, visit www.corning.com/clstrademarks.
All other trademarks are the property of their respective owners.
For more specific information on claims, visit the Certificates page at www.corning.com/lifesciences.
Warranty/Disclaimer: Unless otherwise specified, all products are for research use only. Not intended
for use in diagnostic or therapeutic procedures. Corning Life Sciences makes no claims regarding the
performance of these products for clinical or diagnostic applications.
For additional product or technical information, visit www.corning.com/lifesciences or
call 800.492.1110. Outside the United States, call +1.978.442.2200 or contact your local
Corning sales office.
© 2017 Corning Incorporated. All rights reserved. 12/17 CLS-EQ-123/LN208000
Corning Incorporated
Life Sciences
836 North St.
Building 300, Suite 3401
Tewksbury, MA 01876
t 800.492.1110
t 978.442.2200
f 978.442.2476
www.corning.com/lifesciences
ASIA/PACIFIC
Australia/New Zealand
t 61 427286832
China
t 86 21 3338 4338
f 86 21 3338 4300
India
t 91 124 4604000
f 91 124 4604099
Japan
t 81 3-3586 1996
f 81 3-3586 1291
Korea
t 82 2-796-9500
f 82 2-796-9300
Singapore
t 65 6572-9740
f 65 6861-2913
Taiwan
t 886 2-2716-0338
f 886 2-2516-7500
EUROPE
[email protected]
France
t 0800 916 882
f 0800 918 636
Germany
t 0800 101 1153
f 0800 101 2427
The Netherlands
t 020 655 79 28
f 020 659 76 73
United Kingdom
t 0800 376 8660
f 0800 279 1117
All Other European
Countries
t +31 (0) 206 59 60 51
f +31 (0) 206 59 76 73
LATIN AMERICA
[email protected]
Brasil
t 55 (11) 3089-7400
Mexico
t (52-81) 8158-8400
1
Instruction Manual
Corning®LSE™Mini Microcentrifuge
Table of Contents
General Information ................................................... 1
Intended Use of the Equipment ......................................... 1
Installation ............................................................ 1
Operation.............................................................. 2
Equipment Maintenance ............................................... 2
Rotors ................................................................. 2
Safety Precautions ..................................................... 3
Cleaning .............................................................. 3
Questions and Service ................................................. 3
Specifications ......................................................... 4
Environmental Conditions ............................................. 4
Spare Parts ........................................................... 4
Symbols and Conventions .............................................. 4
Equipment Disposal – European Regulations ........................... 4
Limited Warranty ...................................................... 5
Adapter body AustralianAmerican BritishEuropean
General Information
The Corning® LSE™ Mini Microcentrifuge is supplied with two rotors, one for
microcentrifuge tubes and one for 0.2 mL PCR strip tubes. The eight-place
rotor is designed to centrifuge up to eight individual 1.5/2.0 mL plastic
microcentrifuge tubes. The unit will also include adapters for the following
tubes: 0.5/0.6, 0.4/0.25, 0.2 mL. The strip tube rotor is designed to centrifuge
four 8 x 0.2 mL strip tubes. It will also accept up to 32 individual 0.2 mL
microcentrifuge tubes. Both rotors are designed for applications requiring
relatively low g-forces, such as microfiltration, cell separation and quick
spin downs from the walls of tubes.
Please read this manual thoroughly before attempting to operate the
microcentrifuge.
Intended Use of the Equipment
For quick spin-down from walls or caps of centrifuge tubes.
Installation
1. Make sure to always install the microcentrifuge on a stable, flat surface
only and place it near the electrical outlet.
2. Allow at least 20 cm from walls, 20 cm from ceiling, and 20 cm between
other products.
3. Power adapter instructions
3.1 Power adapter components
3.2 Assembly: Choose the correct plug type to match the local wall socket
and push the plug into its position firmly.
32
Safety Precautions
 Never use the microcentrifuge in any manner not specified in these
instructions.
 Never operate the microcentrifuge without a rotor properly attached to
the shaft.
 Never fill tubes while they are in the rotor. Liquid spillage may harm the
unit.
 Never put hands in the rotor area unless the rotor is completely stopped.
 Never move the microcentrifuge while the rotor is spinning.
 Never use solvents or flammables near this or other electrical equipment.
 Never centrifuge flammable, explosive, or corrosive materials.
 Never centrifuge hazardous materials outside of a hood or proper
containment facility.
 Never try to continue operating the microcentrifuge if the microcentrifuge
stops working prematurely. Stop the microcentrifuge immediately by
turning off the main power switch on the back side of the microcentrifuge.
Wait one minute before turning on the main power switch to operate the
microcentrifuge again.
 Always load the rotor symmetrically. Each tube should be counterbalanced
by another tube. Weight of individual tubes may not exceed 3.0 g.
 Always place the microcentrifuge within easy access to an electrical outlet.
 Always use only microcentrifuge tubes made from plastic and designed
to withstand centrifugal forces of at least 2,000 x g.
Cleaning
Before using any cleaning or decontamination methods other than those
recommended by the manufacturer, check with the manufacturer that
the proposed method will not damage the equipment. To clean the micro-
centrifuge, use a damp cloth and a mild, noncorrosive detergent (pH <8).
After cleaning, ensure all parts are dried thoroughly before attempting
to operate the unit. Do not immerse the microcentrifuge in liquid or pour
liquids over it.
Questions and Service
Should you have a question about the microcentrifuge or required service
for the unit, please use the contact numbers listed. Do not send a unit for
service without first calling to obtain a repair authorization (RA) number
and a decontamination form. Should the microcentrifuge require service,
be sure to decontaminate it and enclose the decontamination form. The
unit should be properly packed to avoid damage. Any damage resulting
from improper packaging shall be the responsibility of the user.
Operation
Before operating the microcentrifuge, be sure that the power switch on the
back of the unit is in the “on” position. To begin a run, simply close the lid
of the microcentrifuge. No other controls are required.
 Fast Stop: Press down and release the tab on the front of the lid. This will
release the lid lock, allowing the lid to open and the rotor to come to a
fast braked stop.
 Gradual Stop: Put the power switch in the “off” position, this will cut
power to the motor and the rotor will come to a gradual stop.
Caution: Do not attempt to open the lid or remove samples until the unit
has come to a complete stop. Once the lid has fully opened and the rotor
has stopped, samples may be removed from the rotor.
Safe operation of the microcentrifuge requires that the rotor be loaded in
a balanced fashion. Failure to load the rotor properly presents a hazardous
condition and may damage the microcentrifuge. Individual tubes, strip tubes,
and/or adapters must always be loaded symmetrically to ensure proper
balance. Never run the microcentrifuge with only one individual tube or
strip tube in place.
Equipment Maintenance
The microcentrifuge should be cleaned periodically. Ensure that the unit is
not plugged in. Use a damp cloth and a mild, noncorrosive detergent (pH <8).
Do not immerse the microcentrifuge in liquid or pour liquids over it. Excessive
amounts of liquid should be avoided. Liquid should not come in contact
with the motor. After cleaning, ensure all parts are dried thoroughly before
attempting to operate the unit.
Rotors
The microcentrifuge is supplied with two interchangeable quick release
rotors. No tools are required to exchange the rotors or attach them to
the motor shaft. The rotors can be easily exchanged with one hand by
way of the quick release system. Removal of the rotors is done by placing
your thumb on top of the motor shaft and lifting up with two fingers
underneath the rotor. Place the other rotor into position on the motor shaft
and snap in.
8 place tube rotor 4 place strip rotor
54
Limited Warranty
Corning Incorporated (Corning) warrants that this product will be free from
defects in material and workmanship for a period of two (2) years from
date of purchase. CORNING DISCLAIMS ALL OTHER WARRANTIES WHETHER
EXPRESSED OR IMPLIED, INCLUDING ANY IMPLIED WARRANTIES OF
MERCHANTABILITY OR OF FITNESS FOR A PARTICULAR PURPOSE. Corning’s
sole obligation shall be to repair or replace, at its option, any product or
part thereof that proves defective in material or workmanship within
the warranty period, provided the purchaser notifies Corning of any such
defect. Corning is not liable for any incidental or consequential damages,
commercial loss or any other damages from the use of this product.
This warranty is valid only if the product is used for its intended purpose
and within the guidelines specified in the supplied instruction manual.
This warranty does not cover damage caused by accident, neglect, misuse,
improper service, natural forces or other causes not arising from defects
in original material or workmanship. This warranty does not cover motor
brushes, fuses, light bulbs, batteries or damage to paint or finish. Claims for
transit damage should be filed with the transportation carrier.
In the event this product fails within the specified period of time because
of a defect in material or workmanship, contact Corning’s Customer Service
at the following numbers: USA: 1.800.492.1110; Canada: 1.978.442.2200.
For other regions of the world, visit www.corning.com/lifesciences or see
the included instruction manual for a list of Worldwide Support Offices.
Corning’s Customer Service team will help arrange local service where
available or coordinate a return authorization number and shipping
instructions. Products received without proper authorization will be
returned. All items returned for service should be sent postage prepaid
in the original packaging or other suitable carton, padded to avoid
damage. Corning will not be responsible for damage incurred by improper
packaging. Corning may elect for onsite service for larger equipment.
Some states do not allow limitation on the length of implied warranties
or the exclusion or limitation of incidental or consequential damages. This
warranty gives you specific legal rights. You may have other rights which
vary from state to state.
No individual may accept for, or on behalf of Corning, any other obligation
of liability, or extend the period of this warranty.
For your reference, make a note of the serial and model number, date of
purchase, and supplier here.
Serial No. ___________________________ Date Purchased _____________________
Model No. _______________________________________________________________
Supplier _________________________________________________________________
Specifications
Dimensions (LxWxH) 6.8 x 5.8 x 4.8 in. (17.4 x 14.8 x 12.2 cm)
Weight 2.43 lbs./1.1 kg
Electrical AC 110-240V, 50/60 Hz, 0.35 A
Unit Input 24VDC 1A
Speed 6,000 rpm
RCF 2,000 x g
Environmental Conditions
 Indoor use only
 Altitude up to 2,000 m
 Temperature 5°C to 40°C
 Maximum relative humidity 80% for temperature up to 30°C decreasing
linearly to 50% relative humidity at 40°C
 Pollution degree 2
Spare Parts
Cat. No. Description
6770-RT Rotor, holds 8 x 1.5/2.0 mL tubes
6770-RTS Rotor, holds 4 x 8 strip tubes
6770-RTA.20 Adapter, 0.20 for rotor (Cat. No. 6770-RT)
6770-RTA.25 Adapter, 0.25 for rotor (Cat. No. 6770-RT)
6770-RTA.5 Adapter, 0.5 for rotor (Cat. No. 6770-RT)
401025 Power Adapter, 24V
Symbols and Conventions
The following chart is an illustrated glossary of the symbols that may be
used in this manual or on the product.
The electrical warning indicates the presence of a potential
hazard which could result in electrical shock.
CAUTION This symbol refers you to important operating
and maintenance (servicing) instructions within the product
Instruction Manual. Failure to heed this information may present
a risk of damage or injury to persons or equipment.
This symbol identifies a Protective Earth (PE) terminal, which is
provided for connection of the supply system’s protective earth
(green or green/yellow) conductor.
Equipment Disposal – European Regulations
According to Directive 2012/19/EU of the European Parliament and of the
Council of 4 July 2012 on waste electrical and electronic equipment (WEEE),
Corning® LSE™ Mini Microcentrifuge (Model No. 6770) is marked with the
crossed-out wheeled bin and must not be disposed of with domestic waste.
Consequently, the buyer shall follow the instructions for reuse and
recycling of waste electronic and electrical equipment (WEEE) provided
with the products and available at www.corning.com/weee.

This manual suits for next models

1

Other CORNING Laboratory Equipment manuals

CORNING LSE 6775 User manual

CORNING

CORNING LSE 6775 User manual

CORNING Gosselin S-Blender 1 Product information sheet

CORNING

CORNING Gosselin S-Blender 1 Product information sheet

CORNING Stripettor 4998 User manual

CORNING

CORNING Stripettor 4998 User manual

CORNING 6928 User manual

CORNING

CORNING 6928 User manual

CORNING Spin-X UF 500 Instruction manual

CORNING

CORNING Spin-X UF 500 Instruction manual

CORNING Labnet Prism R User manual

CORNING

CORNING Labnet Prism R User manual

CORNING Axygen User manual

CORNING

CORNING Axygen User manual

CORNING LSE 6755 User manual

CORNING

CORNING LSE 6755 User manual

CORNING LSE 6780-4 User manual

CORNING

CORNING LSE 6780-4 User manual

CORNING SCF-1296 User manual

CORNING

CORNING SCF-1296 User manual

CORNING LSE 6703 User manual

CORNING

CORNING LSE 6703 User manual

CORNING Axygen Axypet User manual

CORNING

CORNING Axygen Axypet User manual

CORNING X-LAB 6917 User manual

CORNING

CORNING X-LAB 6917 User manual

CORNING LSE Series User manual

CORNING

CORNING LSE Series User manual

CORNING LSE 6703 User manual

CORNING

CORNING LSE 6703 User manual

CORNING LSE 6775 - 120V US User manual

CORNING

CORNING LSE 6775 - 120V US User manual

CORNING Spin-X UF 6 Instruction manual

CORNING

CORNING Spin-X UF 6 Instruction manual

CORNING AXYGEN AxySpin R User manual

CORNING

CORNING AXYGEN AxySpin R User manual

CORNING OptiTect User manual

CORNING

CORNING OptiTect User manual

CORNING PC-611 User manual

CORNING

CORNING PC-611 User manual

CORNING Lambda Plus User manual

CORNING

CORNING Lambda Plus User manual

CORNING LSE 6765-HS User manual

CORNING

CORNING LSE 6765-HS User manual

CORNING Lambda EliteMax User manual

CORNING

CORNING Lambda EliteMax User manual

CORNING CamSplice FBC-017 User manual

CORNING

CORNING CamSplice FBC-017 User manual

Popular Laboratory Equipment manuals by other brands

Air Vent UV-C FiltAir Quick installation guide

Air Vent

Air Vent UV-C FiltAir Quick installation guide

Alfalaval Heatpac EHS-71 System instructions

Alfalaval

Alfalaval Heatpac EHS-71 System instructions

Exor JSPOU0P2 installation guide

Exor

Exor JSPOU0P2 installation guide

Isotech Saturn 877 User maintenance manual/handbook

Isotech

Isotech Saturn 877 User maintenance manual/handbook

PerkinElmer Lambda 465 installation instructions

PerkinElmer

PerkinElmer Lambda 465 installation instructions

PerkinElmer FL 6500 installation instructions

PerkinElmer

PerkinElmer FL 6500 installation instructions

Bio-Science Ampulmatic-10 Purge Gas Injector Operation and maintenance manual

Bio-Science

Bio-Science Ampulmatic-10 Purge Gas Injector Operation and maintenance manual

LABBOX KJD20 user manual

LABBOX

LABBOX KJD20 user manual

red lion N-Tron 1000 Series Hardware guide

red lion

red lion N-Tron 1000 Series Hardware guide

Panlab Rotarod LE8205 Hardware user manual

Panlab

Panlab Rotarod LE8205 Hardware user manual

Assa Abloy SECURITRON AQE15 installation manual

Assa Abloy

Assa Abloy SECURITRON AQE15 installation manual

Beckman Coulter Spinchron DLX instruction manual

Beckman Coulter

Beckman Coulter Spinchron DLX instruction manual

Gilson ASPEC GX-274 Installation procedures

Gilson

Gilson ASPEC GX-274 Installation procedures

Balzers QMG421C operating instructions

Balzers

Balzers QMG421C operating instructions

Fricosmos 040472 instruction manual

Fricosmos

Fricosmos 040472 instruction manual

KoamTac SKXPro quick guide

KoamTac

KoamTac SKXPro quick guide

BIO RAD iCycler quick guide

BIO RAD

BIO RAD iCycler quick guide

MingTai SUN18-III Operation manual

MingTai

MingTai SUN18-III Operation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.