manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. CREE LIGHTING
  6. •
  7. Outdoor Light
  8. •
  9. CREE LIGHTING OSQ Series User manual

CREE LIGHTING OSQ Series User manual

OSQ Series
LED Area Light
1 of 3 LPN00316X0003A0_C
INSTALLATIONINSTRUCTIONS
INSTRUCTIONS D’INSTALLATION
IMPORTANT SAFEGUARDS
When using electrical equipment, basic safety precautions should
always be followed including the following:
READ AND FOLLOW ALL SAFETY
INSTRUCTIONS
1. DANGER- Risk of shock- Disconnect power before installation.
DANGER – Risque de choc – Couper l’alimentation avant
l’installation.
2. This luminaire must be installed in accordance with the NEC or
your local electrical code. If you are not familiar with these codes
and requirements, consult a qualied electrician.
Ce produit doit être installé conformément à NEC ou votre code
électrique local. Si vous n’êtes pas familier avec ces codes et
ces exigences, veuillez contacter un électricien qualié.
SAVE THESE INSTRUCTIONS FOR
FUTURE REFERENCE
TRUNNION MOUNT
NOTE: Access to Components Compartment is not necessary for
installation. To access the Components Compartment, loosen (5) self-
retaining screws on the luminaire Cover Door. See Figure 3.
STEP 1:
Prepare mounting surface for installation. Ensure that mounting
surface and fasteners are suitable for the installation.
STEP 2:
Use dimensions on template shown on the back page for drilling if
mounting surface is not pre-drilled. (Template is not to scale.)
STEP 3:
If necessary, adjust the aiming angle of the trunnion mount by removing
the two aiming bolts, rotating the trunnion mount and then reinstalling
the aiming bolts. The trunnion mount can be aimed in 15 degree
increments. See Figure 1.
STEP 4:
Torque the (2) aiming bolts and (2) trunnion bolts to 30 ft-lbs (40.7 Nm)
using a 1/2" socket and a 7/32" Allen wrench. See Figure 1.
STEP 5:
Secure the trunnion mount to the mounting surface using customer
supplied hardware. Ensure that the fasteners and torque are suitable
for the installation
STEP 6:
After customer supplied mounting bolts are installed and properly
torqued. Torque the (2) 5/16" setscrews using a 5/32" Allen wrench to
100 in-lbs. See Figure 1.
NOTE: For utility flood (UD mounting code), skip to Step 10. For
trunnion accessory (OSQ-TM), continue to Step 7.
TO INSTALL:
1
NOTES:
• DO NOT remove the knock out on the top of the luminaire
(See Figure 3 on page 2). If a NEMA or photocontrol is
desired customer must order OSQ luminaire with factory
installed NEMA Photocell Receptacle (R option). NEMA
photocell receptacle or photo control’s are not field
installable.
TOOLS REQUIRED:
• 7/32", 3/16" and 5/32" Allen wrenches
• 1/2" socket
• Torque wrench
• Prior to installation, store luminaire in a dry location protected from rain,
dust, and outdoor environment. If equipped with a photocell receptacle,
remove the protective cover only if immediately replacing with a suitable
photocell, shorting cap, or other compatible device. The protective socket
cover is not intended to remain in place after installation. Do NOT leave
receptacle open to environmental elements. Luminaires with a top-
mounted photocell receptacle should not be installed in an up-light position
or at a tilt greater than 45 degrees from the down-light position.
Trunnion Bolts
(2) 5/16" Setscrews
Angle Marks 0
To 180 Degrees
In 15 Degree
Increments
Aiming Bolts
2 of 3 LPN00316X0003A0_C
STEP 7:
Route the cord coming from the luminaire head through the Trunnion
Mount. See Figure 2.
STEP 8:
Slide the mounting arm of the luminaire over the Trunnion Mount as
shown in Figure 2.
STEP 9:
Tighten (4) 3/8-16 socket head set screws located on the top of the
mounting arm with a 3/16" Allen wrench to 85 in-lbs (9.6 N•m). See
Figure 2.
STEP 10:
See the Electrical Connections section for wiring instructions.
NEMA®RECEPTACLE (OPTIONAL)
NOTE: When inserting a control unit into the nema receptacle and
rotating control unit to lock in, the engagement force may exceed
the rotational force of the receptacle. If this occurs, the receptacle
and control unit can be rotated clockwise until the hard rotation stop
is reached on the receptacle and locking engagement between the
receptacle and control is achieved. Once engaged, the control unit and
receptacle can be turned counter clockwise to the desired orientation.
Always verify proper installation by pulling up on the control module to
confirm that it is locked into the socket.
STEP 1:
Remove protective cap.
STEP 2:
Rotational adjustment of the photocontrol receptacle is tool-less . DO
NOT loosen/tighten the screws securing the receptacle to the housing.
STEP 3:
Engage/install photocontrol into photocontrol receptacle on top of
luminaire.
STEP 4:
If necessary, rotate photo-control so its photo-eye is aimed in the north
direction. Some photo-controls operate best somewhere between
north-west and north-east.
FIELD ADJUSTABLE DIMMING  (OPTIONAL)
NOTE: This luminaire may be provided with field adjustable dimming.
If so, luminaires leave the factory adjusted to the maximum setting
specified when ordered. Visit www.creelighting.com/products for
product specification sheets.
STEP 1:
The Dimming module is located inside the luminaire. Open the
luminaire door cover by loosening the (5) screws. See Figure 3.
STEP 2:
Establish the desired input power multiplier by referring to the product
dimming spec sheet and turn the switch to the correlating position
STEP 3:
Adjust the Dimming Module, see Figure 4, to the selected position and
reinstall the cover ensuring no wires are pinched.
DRV
DRV CRTL
1 2 3 4 5
9123
4
5
6
7
8
DRV
DRV CRTL
1 2 3 4 5
9123
4
5
6
7
8
4
2
Trunnion
Mount
Luminaire Cover Door
3
DO NOT remove knockout
Luminaire Cord
(4) 3/8" Socket Head
Set Screws
Both Style Switch Knobs are Shown in Position #1
3 of 3 LPN00316X0003A0_C
www.creelighting.com
©2019CreeLighting,AcompanyofIDEALINDUSTRIES.Allrightsreserved.Forinformationalpurposesonly.Content
issubjecttochange.Seewww.creelighting.com/warrantyforwarrantyandspecifications.Cree ®andtheCreelogoare
registeredtrademarksofCree,Inc.NEMA ® isaregisteredtrademarkoftheNationalElectricalManufacturersAssociation.
6.10 in
155mm
3.35 in
85mm
0.55 in
14mm
0.43 in
11mm
0.80 in
20mm
0.43 in
11mm
TEMPLATE
ELECTRICAL CONNECTIONS
STEP 1:
NOTE: Luminaires with PML sensor will have the dimming leads
capped off. Keep the dimming leads on these luminaires capped
off.
Using Listed 90°C minimum rated wire connectors make the
following electrical connections within the adjustable fitter
wiring compartment:
a. For 120/277/347V connect the black fixture lead to the
voltage supply or Hot 1 (for 208/240/480V wiring).
b. For 120/277/347V connect the white fixture lead to the
neutral supply or Hot 2 (for 208/240/480V wiring).
c. Connect the green or green/yellow ground lead to
ground.
d. If Dimming is an option; connect the blue dimming
positive fixture lead to the supply dimming positive lead.
e. If Dimming is an option; connect the white/black
dimming negative fixture lead to the supply dimming
negative lead.
f. Connect orange fixture lead to orange supply lead.
g. Connect red fixture lead to brown supply lead.
LINE
OR HOT 1
GREEN
LINE-BLACK
GROUND-GREEN
NEUTRAL-WHITE
DIM (-)
WHITE/BLACK
DIM (+) BLUE
NEUTRAL
OR HOT 2
VIOLET
GREY
SUPPLY WIRING
(DIMMING OPTIONAL)
LUMINAIRE
RED
ORANGE
BROWN
(CONTROLS FROM
PHOTOCONTROL
OPTIONAL)
ORANGE

Other CREE LIGHTING Outdoor Light manuals

CREE LIGHTING Traveyo Series User manual

CREE LIGHTING

CREE LIGHTING Traveyo Series User manual

CREE LIGHTING VSL Series User manual

CREE LIGHTING

CREE LIGHTING VSL Series User manual

CREE LIGHTING THE EDGE XPS Transportation Series User manual

CREE LIGHTING

CREE LIGHTING THE EDGE XPS Transportation Series User manual

CREE LIGHTING IG Series User manual

CREE LIGHTING

CREE LIGHTING IG Series User manual

CREE LIGHTING SYRIUS User manual

CREE LIGHTING

CREE LIGHTING SYRIUS User manual

CREE LIGHTING LEDway Series Installation instructions

CREE LIGHTING

CREE LIGHTING LEDway Series Installation instructions

CREE LIGHTING SYRIUS SYS-A Series User manual

CREE LIGHTING

CREE LIGHTING SYRIUS SYS-A Series User manual

CREE LIGHTING IG Series User manual

CREE LIGHTING

CREE LIGHTING IG Series User manual

CREE LIGHTING 304 Series Installation instructions

CREE LIGHTING

CREE LIGHTING 304 Series Installation instructions

CREE LIGHTING XSP Series Installation instructions

CREE LIGHTING

CREE LIGHTING XSP Series Installation instructions

CREE LIGHTING EDGE Series User manual

CREE LIGHTING

CREE LIGHTING EDGE Series User manual

CREE LIGHTING XSP Series User manual

CREE LIGHTING

CREE LIGHTING XSP Series User manual

CREE LIGHTING Traveyo Series User manual

CREE LIGHTING

CREE LIGHTING Traveyo Series User manual

CREE LIGHTING EDGE ARE-EDG-R3 User manual

CREE LIGHTING

CREE LIGHTING EDGE ARE-EDG-R3 User manual

Popular Outdoor Light manuals by other brands

Volt VSPL-1045-BBZ-R1 installation instructions

Volt

Volt VSPL-1045-BBZ-R1 installation instructions

kuzco lighting EG64810 quick start guide

kuzco lighting

kuzco lighting EG64810 quick start guide

Artika Trygon SCIN-TG-MB instruction manual

Artika

Artika Trygon SCIN-TG-MB instruction manual

Portfolio 00906 manual

Portfolio

Portfolio 00906 manual

Saxby Lighting Severus Instruction leaflet

Saxby Lighting

Saxby Lighting Severus Instruction leaflet

BES LED OUTDOOR Series manual

BES LED

BES LED OUTDOOR Series manual

Howard SLS008 Series Installation instructions manual

Howard

Howard SLS008 Series Installation instructions manual

Malmbergs JRA2 instruction manual

Malmbergs

Malmbergs JRA2 instruction manual

iGuzzini FLAMINIA manual

iGuzzini

iGuzzini FLAMINIA manual

Malibu Boats CS14SM Install manual

Malibu Boats

Malibu Boats CS14SM Install manual

Sulion REGA 400902 manual

Sulion

Sulion REGA 400902 manual

C Luce LUXEON M quick start guide

C Luce

C Luce LUXEON M quick start guide

Lumena OLY800-D-PIR/GSK-PS2 user manual

Lumena

Lumena OLY800-D-PIR/GSK-PS2 user manual

Malmbergs Cupid 77 170 03 instruction manual

Malmbergs

Malmbergs Cupid 77 170 03 instruction manual

Inca 8712F Instruction leaflet

Inca

Inca 8712F Instruction leaflet

Kichler Lighting 16099BK manual

Kichler Lighting

Kichler Lighting 16099BK manual

Performance In Lighting THEOS manual

Performance In Lighting

Performance In Lighting THEOS manual

WE-EF EFL540 LED Installation and maintenance instructions

WE-EF

WE-EF EFL540 LED Installation and maintenance instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.