manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Crow
  6. •
  7. Security Sensor
  8. •
  9. Crow SWAN QUAD User manual

Crow SWAN QUAD User manual

INSTALLATION INSTRUCTIONS
SWAN QUAD
PIR MOTION DETECTOR With PET IMMUNITY up to 25 kg
PRODUCT FEATURES
The SWAN QUAD detector uses a special
designed optical Lens with unique Quad (Four
element) PIR Sensor and new ASIC based
electronics optimized to eliminate false alarms,
caused by small animals and Pets.
The SWAN QUAD provides unprecedented levels
of immunity against visible light.
The Detector offers an exceptional level of
detection capability and stability for every
security installation.
The SWAN QUAD is supplied with a Wide Angle
lens.
•Quad Linear Imaging Technology for sharp
analysis of body dimensions and
differentiation from background and animals.
•ASIC based electronics.
•Immunity to animals up to 25kg.
•18m Detection Range with Wide Angle Lens.
•Temperature compensation.
•Compact Design for Residential Installation.
•Variable pulse width adjustment.
•Sensitivity adjustment.
•Environmental immunity.
•Height installation calibration free
(1.8m – 2.4m).
•LED Remote function.
SELECT MOUNTING LOCATION
Choose a location most likely to intercept an intruder.
(Our recommendation is a corner installation). See
detection pattern fig.3. The quad-element high quality
sensor detects motion crossing the beam; it is slightly
less sensitive detecting motion toward the detector.
The SWAN quad performs best when provided with a
constant and stable environment and background.
AVOID THE FOLLOWING LOCATIONS
•Facing direct sunlight.
•Facing areas that may change temperature
rapidly.
•Areas where there are air ducts or substantial
airflows.
WIRE SIZE REQUIREMENTS
Use #22 AWG (0.5 mm) or wires with a larger
diameter. Use the following table to determine the
required wire gauge (diameter) depending on the
length of wire between the detector and the control
panel.
Wire Length m 200 300 400 800
Wire Diameter mm .5 .75 1.0 1.5
Wire Length ft. 800 1200 2000 3400
Wire Gauge # 22 20 18 16
DETECTOR INSTALLATION
The detector can either be wall or corner mounted.
If ceiling or special wall mounting is required, use the
optional bracket base. Refer to bracket description.
(See fig. 6).
1.To remove the front cover, unscrew the holding screw
and gently raise the front cover.
Fig.1
2. To remove the PC board, carefully unscrew the
holding screw located on the PC board.
3. Break out the desired holes for proper installation.
Fig.2
4.The circular and rectangular indentations at the
bottom base are the knockout holes for wire entry.
You may also use mounting holes that are not in
use for running the wiring into the detector. (For
Bracket option - lead wire through the bracket)
5.Mount the detector base to the wall, corner or ceiling.
(For bracket installation option see fig. 6).
6.Reinstall the PC board by fully tightening the holding
screw. Connect wire to terminal block.
7.Replace the cover by inserting it back in the
appropriate closing pins and screw in the holding
screw.
DETECTOR CONNECTION
Terminal 1 - Marked “ - ” (GND)
Connect to the negative Voltage Supply or ground of
the control panel.
Terminal 2 - Marked “ + ” (+12V)
Connect to a positive Voltage Supply of 8.2 -16Vdc
source (usually from the alarm control unit)
Terminals 3 & 6 - Marked “ EOL ” – End of line
option.
Terminals 4 & 5 - Marked “ TAMPER ”
If a Tamper function is required connect these
terminals to a 24-hour normally closed protective zone
in the control unit. If the front cover of the detector is
opened, an immediate alarm signal will be sent to the
control unit.
Terminals 7 & 8 - Marked “RELAY ”
These are the output relay contacts of the detector.
Connect to a normally closed zone in the control
panel.
TESTING THE DETECTOR
Wait one minute after applying 12 Vdc power for warm
up time. Conduct testing with the protected area
cleared of all people.
Walk test
1. Remove front cover.
2. Set LED to ON position.
3. Reassemble the front cover.
4. Start walking slowly across the detection zone.
5. Observe that the LED lights whenever motion is
detected.
6. Allow 5 sec. between each test for the detector to
stabilize.
7. After the walk test is completed, you can set the
LED to OFF position.
NOTE:
Walk tests should be conducted, at least once a year,
to confirm proper operation and coverage of the
detector.
Fig.3
Fig.4
7101570_D.doc - 1 -
Holding screw
A. Wire access holes
B. Use for flat wall
mounting
C. Corner mounting -
use all 4 holes.
Sharp left or right
angle mounting -
use 2 holes (top
and bottom)
D. For bracket
mounting
C
A
D
A A
B
B
B
B
C
C
C
INSTALLATION INSTRUCTIONS
SWAN QUAD
PIR MOTION DETECTOR With PET IMMUNITY up to 25 kg
SETTING UP THE DETECTOR
PET IMMUNITYJUMPER SETTING
This jumper is used for setting the PET Immune
function - up to 15kg or 25kg, depending on the pet
size.
PULSE WIDTH JUMPER SETTING
This jumper is used for setting the PULSE count
function in order to provide PIR sensitivity control
according to the environment.
LED ENABLE JUMPER SETTING
This jumper is used for setting - LED Enable / Disable.
Note: The LED Switch does not affect the operation of
the relay.
When an intrusion is detected, the LED will activate
and the alarm relay will switch into alarm condition for
2 sec.
PIR SENSITIVITY ADJUSTMENT
Use the Potentiometer marked “SENS” to adjust the
detection sensitivity between 15% and 100%,
according to walk test in the protected area.
(Factory set to 57%)
Rotate the potentiometer clockwise to increase range,
counter-clockwise to decrease range.
Fig.5
BRACKET INSTALLATION OPTION
Ceiling bracket base Wall bracket base
Fig. 6
TECHNICAL SPECIFICATION
MODEL SWAN QUAD
Detection Method Quad (Four element) PIR
Power Input 8.2 to 16 VDC
Current Draw Standby: 8mA (±5%)
Active: 10mA (±5%)
Temperature
Compensation YES
Pulse Width Adjustable
Alarm Period 2 sec (±0.5sec)
Alarm Output N.C 28VDC 0.1 A with
27Ohm series protection
resistor
Tamper Switch N.C 28VDC 0.1A with
10 Ohm series protection
resistor - open when
cover is removed
Warm Up Period 60sec (±5sec)
LED Indicator LED is ON during alarm
Operating Temperature -20
°
C to +60
°
C
RFI Protection 30V/m 10 - 1000MHz
EMI Protection 50,000V of electrical
interference from lightning
or power through
Dimensions 92mm x 59mm x 37mm
Weight 40gr
CROW ELECTRONIC ENGINEERING LTD. ("Crow") - WARRANTY POLICY CERTIFICATE
This Warranty Certificate is given in favor of the purchaser (hereunder the "Purchaser") purchasing the products directly from Crow or from its authorized distributor.
Crow warrants these products to be free from defects in materials and workmanship under normal use and service for a period of 24 months from the last day of the week and
year whose numbers are printed on the printed circuit board inside these products (hereunder the "Warranty Period").
Subject to the provisions of this Warranty Certificate, during the Warranty Period, Crow undertakes, at its solediscretion and subject to Crow's procedures, as such procedures
are form time to time, to repair or replace, free of charge for materials and/or labor, products proved to be defective in materials or workmanship under normal use and service.
Repaired products shall be warranted for the remainder of the original Warranty Period.
All transportation costs and in-transit risk of loss or damage related, directly or indirectly, to products returned to Crow for repair or replacement shall be borne solely by the
Purchaser.
Crow's warranty under this Warranty Certificate does not cover products that is defective (or shall become defective) due to: (a) alteration of the products (or any part thereof)
by anyone other than Crow; (b) accident, abuse, negligence, or improper maintenance; (c) failure caused by a product which Crow did not provide; (d) failure caused by
software or hardware which Crow did not provide; (e) use or storage other than in accordance with Crow’s specified operating and storage instructions.
There are no warranties, expressed or implied, of merchantability or fitness of the products for a particular purpose or otherwise, which extend beyond the description on the
face hereof.
This limited Warranty Certificate is the Purchaser's sole and exclusive remedy against Crow and Crow's sole and exclusive liability toward the Purchaser in connection with the
products, including without limitation - for defects or malfunctions of the products. This Warranty Certificate replaces all other warranties and liabilities, whether oral, written,
(non-mandatory) statutory, contractual, in tort or otherwise.
In no case shall Crow be liable to anyone for any consequential or incidental damages (inclusive of loss of profit, and whether occasioned by negligence of the Crow or any
third party on its behalf) for breach of this or any other warranty, expressed or implied, or upon any other basis of liability whatsoever. Crow does not represent that these
products can not be compromised or circumvented; that these products will prevent any person injury or property loss or damage by burglary, robbery, fire or otherwise; or that
these products will in all cases provide adequate warning or protection.
Purchaser understands that a properly installed and maintained product may in some cases reduce the risk of burglary, fire, robbery or other events occurring without providing
an alarm, but it is not insurance or a guarantee that such will not occur or that there will be no personal injury or property loss or damage as a result.
Consequently, Crow shall have no liability for any personal injury; property damage or any other loss based on claim that these products failed to give any warning.
If Crow is held liable, whether directly or indirectly, for any loss or damage with regards to these products, regardless of cause or origin, Crow’s maximum liability shall not in
any case exceed the purchase price of these products, which shall be the complete and exclusive remedy against Crow.
P/N 7101570 REV. D Y.S - A.Y.
CROW ELECTRONIC ENGINEERING LTD.
12 Kineret St.
Airport City, 70100 Israel
Tel. +972 3 9726000
Fax. +972 3 9726001
sales@crow.co.il
[email protected]
www.thecrowgroup.com
CROW LATIN AMERICA USA INC.
7200 NW 19 st.
Suite 307
Miami FI 33126, USA
Tel. +305 513 4001
Fax. +305 513 4005
rejane@crowlatinamerica.com
www.crowlatinamerica.com
ARROWHEAD ALARM PRODUCTS
344B, Rosedale Road
Park Farm Industrial Estate
Albany, Auckland
New Zealand
Tel. +64 9 414 0085
Fax. +64 9 414 0088
www.aap.co.nz
These instructions supersede all previous issues in circulation prior to December 2011.
7101570_D.doc - 2 -
Immune to pet
weighting up to 15 kg
Immune to pet
weighting up to 25 kg
Very stable environment
Jumper #1 = ON
Without PET
Moderate nuisance situation
Jumper #2 = ON
PET up to 15 kg
Relatively high chance of false
alarms
Jumper #3 = ON
PET up to 25 kg
ON - LED ENABLE. The LED will
activate when the detector is in
alarm condition.
OFF - LED DISABLE, The LED is
disabled.
N345

Other Crow Security Sensor manuals

Crow SWAN QUAD User manual

Crow

Crow SWAN QUAD User manual

Crow TLC-360 User manual

Crow

Crow TLC-360 User manual

Crow BS-1 Manual

Crow

Crow BS-1 Manual

Crow FW2 FLOOD 8F User manual

Crow

Crow FW2 FLOOD 8F User manual

Crow FREEWAVE FW-P100 User manual

Crow

Crow FREEWAVE FW-P100 User manual

Crow SRDT-15 User manual

Crow

Crow SRDT-15 User manual

Crow SH-SIRINT-8F User manual

Crow

Crow SH-SIRINT-8F User manual

Crow SH-CRT-8F User manual

Crow

Crow SH-CRT-8F User manual

Crow SRDT-15 User manual

Crow

Crow SRDT-15 User manual

Crow SH-PIR-8F User manual

Crow

Crow SH-PIR-8F User manual

Crow SWAN 1000 User manual

Crow

Crow SWAN 1000 User manual

Crow TL-360 User manual

Crow

Crow TL-360 User manual

Crow EDS-2000AM User manual

Crow

Crow EDS-2000AM User manual

Crow MRX-220N User manual

Crow

Crow MRX-220N User manual

Crow NEO QUAD User manual

Crow

Crow NEO QUAD User manual

Crow SH-MAG-SHOCK-8F User manual

Crow

Crow SH-MAG-SHOCK-8F User manual

Crow SH-SIRINT-9F User manual

Crow

Crow SH-SIRINT-9F User manual

Crow SH-FLOOD-9F User manual

Crow

Crow SH-FLOOD-9F User manual

Crow FW2-SMK User manual

Crow

Crow FW2-SMK User manual

Crow GENIUS Setup guide

Crow

Crow GENIUS Setup guide

Crow SH-SIRINT-8F User manual

Crow

Crow SH-SIRINT-8F User manual

Crow EDS-2000 Manual

Crow

Crow EDS-2000 Manual

Crow SH-FLOOD-8F User manual

Crow

Crow SH-FLOOD-8F User manual

Crow EDS-2000 Manual

Crow

Crow EDS-2000 Manual

Popular Security Sensor manuals by other brands

Camp Safety GOBLIN manual

Camp Safety

Camp Safety GOBLIN manual

Ansell AE3LED/3M installation instructions

Ansell

Ansell AE3LED/3M installation instructions

UTC Fire and Security interlogix TX-2211-03-1 868 GEN2 Installation sheet

UTC Fire and Security

UTC Fire and Security interlogix TX-2211-03-1 868 GEN2 Installation sheet

Nokta FORS relic user manual

Nokta

Nokta FORS relic user manual

Nice F210 installation instructions

Nice

Nice F210 installation instructions

Quandify CubicDetector QCD-01 manual

Quandify

Quandify CubicDetector QCD-01 manual

LEGRAND 0 489 36 manual

LEGRAND

LEGRAND 0 489 36 manual

AJAX GlassProtect Fibra user manual

AJAX

AJAX GlassProtect Fibra user manual

Energy Saving Sensors HC-7B installation manual

Energy Saving Sensors

Energy Saving Sensors HC-7B installation manual

Optex Smart Line Series installation instructions

Optex

Optex Smart Line Series installation instructions

Satel APMD-150 manual

Satel

Satel APMD-150 manual

Satel GREY manual

Satel

Satel GREY manual

Gemtor FLW Series owner's manual

Gemtor

Gemtor FLW Series owner's manual

STEINEL Professional IR Quattro HD-2 COM1 manual

STEINEL

STEINEL Professional IR Quattro HD-2 COM1 manual

AdirPro MC-10 quick start guide

AdirPro

AdirPro MC-10 quick start guide

Busch-Jaeger Busch-Wachter 220 MasterLINE 6847 Series quick start guide

Busch-Jaeger

Busch-Jaeger Busch-Wachter 220 MasterLINE 6847 Series quick start guide

Trebs KC-186 Operation manual

Trebs

Trebs KC-186 Operation manual

Smartwares RM640K manual

Smartwares

Smartwares RM640K manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.