1 General
The EDS-2000AM is a unique motion detector utilizing a single (quad element) passive
infra-red element and Microwave technology with antimask feature
for use outdoors in harsh
environments.
The EDS-2000AM is designed for outdoor use in the most severe and climatic conditions and
may also accommodate pets with the addition of optional pet immunity lenses.
High reliability is achieved by combining both dual tech hardware with highly sophisticated
software, greatly reducing the possibility of false alarms.
The active elements are comprised of a single (quad element) PIR and advanced Microwave
detector inside a stylish, rigid plastic body.
These special optics combined with a Microwave Doppler sensor assures elimination of “false
alarms” while maintaining high security standards for the detection of human intruders into the
protected area.
The detection sensitivity and range is controlled by a potentiometer allowing fine tuning, so that
the correct detection pattern will be set for every installation.
The EDS-2000AM is designed to protect large areas and can easily be installed on walls in
order to provide a solid protection of the area while rejects interferences from birds and small
animals due to the optional “PET MASK” optics.
2 Features
•Microwave detection based on Doppler concept.
•N.O relays switched at the same time.
•Installation height is calibration free from 1.8m to 2.4m (5.9 to 7.8 ft)
•PIR sensitivity adjustment.
•MW intensity selection.
•Temperature compensation.
•Microcontroller signal processing.
•Anti mask mechanism (for PIR lens).
•Front and back tamper protection.
•Unique waterproof and sealed plastic design.
•Detection Range: Up to 12m
•Detects human intruders walking or running.
•No maintenance required.
•High RFI/EMI Immunity.
•Protection from: direct sunlight, wind up to 30 m/sec, snow and rain, small animals, removal
of top cover and removal from mounting bracket.
P/N: 7101796A
NC
SW DIP-4
2
SW2
FACTORY SETTING
1 2 3 4
SW DIP-2
IR-78
PIR
100R
NC
NC
DM-03S-1P
POT
1M
1K 2.61K
845R 3.48K 2.61K 3.48K
1K
HEADER 2X4
HEADER 2X4
HEADER 2X4 HEADER 2X2
BLOCK 10
365R
365R
845R
SW1
FACTORY SETTING
1 2
SW1
MW sensitivity
PIR sensitivity
Anti mask module
connector
MW antenna
PIR sensor
3 Assembly description
The EDS-2000AM is a robust yet small detector which includes a large LED indicator that can
be easily observed from long distances to provide indication of intrusion. Using the supplied
mounting bracket, the EDS-2000AM can be easily mounted to walls using the provided
mounting screws. For
installations requiring the detection beam to be adjusted horizontally or
vertically to obtain the desired field of protection use the Outdoor Mounting Bracket pictured
below. (not included)
EDS-2000AM Outdoor Motion Detector Outdoor Mounting Bracket
The EDS-2000AM consists of two detection elements:
•PIR element
•Microwave element
P/N: 7101796A
4 Detection Pattern
The EDS-2000AM has a 90°top view PIR and MW detection pattern with 12m detection
distance (when installed at 2.4m above the ground surface).
Standard Lens
P/N: 7101796A
Corridor Lens (sold separately)
Having MW movement detection combined with PIR detection beam, the EDS-2000AM
can differentiate between pets and human bodies and alert accordingly.
By having both PIR detection beam and MW crossing an object it will be defined as intrusion,
Causing an alarm. In case only MW detects motion and PIR does not, no alarm will be generated.
P/N: 7101796A
5 Selecting mounting location
The installation of the EDS-2000AM requires straight and solid base for the detector and
setting of front panel against the center of protected area.
The protected area must be free from obstacles like walls, fences, trees, ditches and
other microwave detectors, as well as systems of anti-intrusion
surveillance.
The bracket provides EDS-2000AM installation on a wall. The
wall should be leveled.
Choose a location most likely to intercept an intruder according
to detection pattern on page 5.
Avoid the following Installation Locations:
•Facing direct sunlight.
•Facing areas subject to rapid temperature changes.
•Mounted at more than 10º from the vertical or horizontal plane.
•Facing metal doors.
•Near direct sources of heat or airflow.
•Clear all physical obstacles from the detection area
(e.g. plants, laundry, etc.)
•Clear all light reflecting surfaces from the detection area,
including puddles or other standing water.
•Avoid installation on the following types of ground:
Thick vegetation, Grass (un-mown), Water, Sand and Metal.
NOTES:
•Recommended installation height is 2.1m (6.8 ft).
•The PIR sensor detects motion crossing the beam; it is less sensitive detecting motion
towards the detector.
•The EDS-2000AM performs best when provided with a constant and stable environment.
•In order to ensure suitable operation of the EDS-2000AM, the type of ground should be one
of the following: Asphalt concrete, Cement, Soil, Clay, Gravel or Grass (mown).
P/N: 7101796A
6 Detector Installation
Important! Prior to installation, read both “Operation” and “Selecting the mounting location”
sections carefully.
1. Install the detector in such manner that the intruder is
most likely to cross the detection area from side to side.
2. The detector is to be installed at height of 1.8 to 2.4
meters (5.9 to 7.8 ft) , ideally 2.1m (6.8 ft)
3. Make sure to attach the metal bracket to a leveled
straight and firm wall, leaving 10cm (3.9 inches) from
the top and 10cm (3.9 inches) from both sides, for easy
installation and maintenance.
4. Placing the detector on perpendicular wall is
required for guarding a side window opening.
Alternately the LC-B1-15X Outdoor Mounting bracket
can be installed on the same wall, allowing the
detector beam to be rotated towards the window.
5. Open the detector unwinding the bottom screw.
6. Release the rear metal bracket by unwinding
internal bottom screw.
P/N: 7101796A
7. Release the detector body from the metal bracket by
pulling the detector up and out.
8. Attach the rear bracket to the wall using mounting
screws.
9. Insert wires through provided access hole and wiring
channels.
10. Attach the sealing sponge pad to the wire opening
from the rear side after the wires have been
connected and prior to final product affixing to the
mounted bracket.
11. Place the detector on the mounting bracket from top
side down and then lock the screw at the bottom.
12. If Pet immunity up to 15kg is desired do not install
the mechanical pet filter.
If Pet immunity up to 36kg is desired install the
mechanical pet filter. In this case, the AM option must
be turned off to avoid AM alarm.
P/N: 7101796A
7 Terminal Block Connections
Terminal 1 - Marked “+” (+12V) - Connect to a positive Voltage of 9.6 -16Vdc source
(Usually from the alarm CP)
Terminal 2 - Marked “-” (GND) - Connect to the ground of the CP.
Terminal 3 –Marked "Test" 9.6-16 v on this pin will enter the EDS2000AM to walk test
mode even if SW2 position 1 is off
Terminals 4 & 5 - Marked “ALARM” - These are the output relay contacts of the detector.
Connect to a normally closed or normally opened zone in the control unit. When an
intruder is detected, alarm relays (N.C. and N.O.) will switch for 1.8 sec.
Terminal 6&7 - Marked “AM/FAIL" These are the output of the anti mask and Trouble relay
(N.C. and N.O.) Will switch if one from the following scenario happens:
The supply voltage is under 8.5v
Mask detection (will restore if the mask is removed)
PIR or MW self test fail (every 10 hours the detector made self test for PIR and MW
sensors)
Terminal 8 - Marked “TEOL” - End of line – optional terminal for end of line resistors
connections.
Terminals 10 & 9 - Marked “TAMPER” - If a Tamper function is required connect these
terminals to a 24-hour normally closed protective zone in the CP.
If the top cover of the detector is opened or the detector is detached from installation wall,
an immediate alarm signal will be sent to the CP.
7.1 Wire Size Requirements
Use #22 AWG or larger wires. Use the following table to determine required wire gauge
and length.
Wire Length [m] 205 310 510 870
Wire Length [ft.] 800 1200 2000 3400
Wire Gauge [#] 22 20 18 16
P/N: 7101796A
NC
SW DIP-4
2
SW2
FACTORY SETTING
1 2 3 4
SW DIP-2
IR-78
PIR
100R
NC
NC
DM-03S-1P
POT
1M
1K 2.61K
845R 3.48K 2.61K 3.48K
1K
HEADER 2X4
HEADER 2X4
HEADER 2X4 HEADER 2X2
BLOCK 10
365R
365R
845R
SW1
FACTORY SETTING
1 2
SW1
MW sensitivity
PIR sensitivity
Anti mask module
connector
MW antenna
PIR sensor
8 Settings & Adjustments
8.1 Detection beam direction
The EDS-2000AM detection beam direction is fixed. As a result, it is recommended to
face the intrusion area with the detector.
8.2 Sensitivity and Range Adjustment
There are 2 options for PIR sensitivity option:
PIR potentiometer adjust
SW position 3 – PIR pulse setting when up- 2 pulses down -3 pulses
P/N: 7101796A
General configuration setting table (for sw2)
Feature Sw position On (up) Off (down)
Indication LEDs 1 Indication LEDs on Indication LEDs off
Anti Mask 2 ON Off
PIR pulse count 3 2 pulses 3 pulses
Pet immunity 4 On Off
The sensitivity adjustment is performed by setting a potentiometer and MW jumper as
Follows (using clock needle positioning):
Environment
t
y
pe
Potentiometer
position
Low risk
4 o’clock
Risk 12 ~ 3 o’clock
High risk 3 ~ 4 o’clock
Very high risk 12 ~ 3 o’clock
Noisy area 9 ~ 12 o’clock
Extremely Noisy area 8 o’clock
Note: Adjust sensitivity according to environmental conditions!
8.2.2 MW Sensitivity adjustment
The MW has 4 configurable levels by SW1:
Position 1 Position 2
up up High sensitivity more suitable for indoor application*
up down High sensitivity for outdoor application
down up Medium sensitivity for outdoor application
down down Low sensitivity for outdoor application
P/N: 7101796A
*Note: when the MW sensitivity is applied the detector is very sensitive and it’s effected the PIR
adjustment also to 1 pulse only.
8.3 Pet immunity setting
The EDS-2000AM has a detachable Pet immunity filter. As such the Pet immunity level may
vary between:
1. 36kg (80 lbs) with pet immunity filter assembled
2. 15kg (33 lbs) if no pet immunity filter is used.
Note: adding this optic filter will cause anti mask alarm, turn off the
AM when adding this filter (position 2 on SW2).
You can apply an electric pet immunity by pulling up SW2 position 4
The installer is to select the requested Pet immunity level.
The filter is to be installed according to the following orientation:
This side up!
P/N: 7101796A
8.4 Indications setting
The EDS-2000AM has 3 LEDs that each points at different indication:
1. Green LED indicates PIR detection.
2. Yellow LED indicates MW detection.
3. Red LED - alarm indication (logic AND of both MW and PIR).
The installer has an option to control LEDs operation, using the LED control on SW2
position 1, between “ON” and “OFF”. Or by apply 9.6-16v to terminal block position 3
("test")
•
Place the top cover to the base and close it using the bottom screw.
P/N: 7101796A
9. Anti mask
The EDS-2000AM has a sophisticate anti mask module:
This module is assembled on the EDS2000AM main board.
To activate the AM please pull up SW2 position 2 and remove the PET optic filter.
The EDS2000AM has aambient light sensor.
The EDS2000AM made self calibration for the anti mask 30 minutes after power up.
Please be verify during installation that the EDS2000AM is closed well before 30 minutes
from power up.
If the first power up is under direct sunlight the EDS2000AM will made the self calibration
30 minutes after the sun light intensity will decrease
10 Operation
Note! Connect the EDS-2000AM to a positive Voltage output of 9.6 -16VDC
source.
Use only a listed power limited source.
The detector shall be provided with minimum of 4 hours of standby power from either a
listed compatible control unit or power supply.
The detector is automatically operated once connected to power.
The LEDs start flashing one at a time (side to side) for 30 seconds during the warm-up
period and after that it will turn off.
At this time the detector is ready for operation.
P/N: 7101796A
11 Test procedures
Walk Test
Make sure LEDs control is set to “ON”
Allow 30 seconds of warm up time.
Make sure that the protected area is cleared of all people.
Start walking across the detection zone.
Look at the LEDs whenever motion is detected - all LEDs are turned ON.
Allow 5 sec. between each test for the detector to stabilize.
Upon installation, the unit should be thoroughly tested to verify proper operation.
Walk across the entire area where coverage is desired. Should the coverage be incomplete,
readjust sensitivity or relocate the detector.
Once coverage is as desired the LEDs may be disabled.
NOTE: Walk Test procedure should be conducted, at least once a year, to confirm
proper operation and coverage of the detector.
P/N: 7101796A
12 Specifications
Detection
Method
PIR AND MW
Microwave Frequency
X-band (9.9GHz / 10.525GHz / 10.687GHz)
Po
w
er Input
9.6 to 16Vdc
Current Draw
Active: 24mA (±5%)
Standby: 21mA (±5%)
Temp
C
o
mpensation
Dual slop temperature compensation
Alarm
Period
2 sec (±0.5sec)
Alarm Outputs
Form C (NC, NO, Common)
28Vdc 0.1 A with 10 Ohm
Tamper Switch(s)
Two Switches
N.C 28Vdc 0.1 A with 10 Ohm Series protection resistors
Opens when cover is removed from unit’s base
Warm
up Period
30sec (± 5sec)
RF
Immunity
10 V/m plus 80% AM from 80 MHz to 2GHz
Electrostatic
Immuni
t
y
6kV contact, 8kV air
Transient
Immunity
1kV
Operation
Te
mp
-35ºC ~ +55ºC
Dimensions
160 mm x 70 mm x 45 mm
Weight
210gr.
European directives RTTE , EMC, Low Voltage, RoHS
USA & Canada
47CFR part 15, subpart C, section 15.245, 47CFR part 15,
subpart B
RSS210, ICES-003
Protection
Degree
IEC 60529: IP 65
* Specifications are subject to change without prior notice.
P/N: 7101796A
CROW LIMITED WARRANTY
(CROW) warrants this product to be free from defects in materials and
workmanship under normal use and service for a period of two years from
the last day of the week and year whose numbers are printed on the printed
circuit board inside this product.
CROW’s obligation is limited to repairing or replacing this product, at its
option, free of charge for materials or labor, if it is proved to be defective in
materials or workmanship under normal use and service. CROW shall
Have no obligation under this Limited Warranty or otherwise if the product is
altered or improperly repaired or serviced by anyone other than CROW.
There are no warranties, expressed or implied, of merchantability or fitness
for a particular purpose or otherwise, which extend beyond the
Description on the face hereof. In no case shall CROW be liable to anyone
for any consequential or incidental damages for breach of this or any other
warranty, expressed or implied, or upon any other basis of liability
whatsoever, even if the loss or damage is caused by CROW’s own
negligence or fault.
CROW does not represent that this product cannot be compromised or
circumvented; that this product will prevent any person injury or property
loss or damage by burglary, robbery, fire or otherwise; or that this product
will in all cases provide adequate warning or protection. Purchaser
understands that a properly installed and maintained product can only
reduce the risk of burglary, robbery or other events occurring without
providing an alarm, but it is not insurance or a guarantee that such will not
occur or that there will be no personal injury or property loss or damage as a
result. Consequently, CROW shall have no liability for any personal injury;
property damage or any other loss based on claim that this product failed to
give any warning. However, if CROW is held liable, whether directly or
indirectly, for any loss or damage arising under this limited warranty or
otherwise, regardless of cause or origin, CROW’s maximum liability shall
not in any case exceed the purchase price of this product, which shall be
The complete and exclusive remedy against CROW.
ELECTRONIC
ENGINEERING
LTD.
CROW ELECTRONIC ENGINEERING LTD.
12 Kineret St.
Airport City, 70100 Israel
Tel. +972 3 9726000
Fax. +972 3 9726001
[email protected]
[email protected]
www.thecrowgroup.com
CROW LATIN AMERICA USA INC.
7200 NW 19 st.
Suite 307
Miami FI 33126, USA
Tel. +305 513 4001
Fax. +305 513 4005
rejane@crowlatinamerica.com
www.crowlatinamerica.com
ARROWHEAD ALARM PRODUCTS
344B, Rosedale Road
Park Farm Industrial Estate
Albany, Auckland
New Zealand
Tel. +64 9 414 0085
Fax. +64 9 414 0088
www.aap.co.nz
These instructions supersede all previous issues
in circulation prior to January 2012.

Other manuals for EDS-2000AM

1

Other Crow Security Sensor manuals

Crow SH-MAG-SHOCK-8F User manual

Crow

Crow SH-MAG-SHOCK-8F User manual

Crow EDS-2000 Manual

Crow

Crow EDS-2000 Manual

Crow TLC-360 User manual

Crow

Crow TLC-360 User manual

Crow TL-360 User manual

Crow

Crow TL-360 User manual

Crow FREEWAVE FW-P100 User manual

Crow

Crow FREEWAVE FW-P100 User manual

Crow SH-CRT-8F User manual

Crow

Crow SH-CRT-8F User manual

Crow SH-SIRINT-8F User manual

Crow

Crow SH-SIRINT-8F User manual

Crow MRX-220N User manual

Crow

Crow MRX-220N User manual

Crow FW2-SMK User manual

Crow

Crow FW2-SMK User manual

Crow BS-1 Manual

Crow

Crow BS-1 Manual

Crow EDS-2000 Manual

Crow

Crow EDS-2000 Manual

Crow SWAN QUAD User manual

Crow

Crow SWAN QUAD User manual

Crow SWAN QUAD User manual

Crow

Crow SWAN QUAD User manual

Crow NEO QUAD User manual

Crow

Crow NEO QUAD User manual

Crow GENIUS Setup guide

Crow

Crow GENIUS Setup guide

Crow SH-FLOOD-9F User manual

Crow

Crow SH-FLOOD-9F User manual

Crow SRDT-15 User manual

Crow

Crow SRDT-15 User manual

Crow SH-PIR-8F User manual

Crow

Crow SH-PIR-8F User manual

Crow SRDT-15 User manual

Crow

Crow SRDT-15 User manual

Crow SH-FLOOD-8F User manual

Crow

Crow SH-FLOOD-8F User manual

Crow SH-SIRINT-9F User manual

Crow

Crow SH-SIRINT-9F User manual

Crow FW2 FLOOD 8F User manual

Crow

Crow FW2 FLOOD 8F User manual

Crow SWAN 1000 User manual

Crow

Crow SWAN 1000 User manual

Crow SH-SIRINT-8F User manual

Crow

Crow SH-SIRINT-8F User manual

Popular Security Sensor manuals by other brands

MUNBYN IMC02 user manual

MUNBYN

MUNBYN IMC02 user manual

Gardner Denver THOMAS ASF VAKUMATIK IVF R34 Installation and operation manual

Gardner Denver

Gardner Denver THOMAS ASF VAKUMATIK IVF R34 Installation and operation manual

General RLD440 user manual

General

General RLD440 user manual

hyfire ALTAIR HFI-MA-05 quick start guide

hyfire

hyfire ALTAIR HFI-MA-05 quick start guide

Macurco OX-6 User instructions

Macurco

Macurco OX-6 User instructions

GEV TITAN FLAT180 LBB 16859 user manual

GEV

GEV TITAN FLAT180 LBB 16859 user manual

SYNCOLN 13100 quick start guide

SYNCOLN

SYNCOLN 13100 quick start guide

Bircher Reglomat MERKUR operating instructions

Bircher Reglomat

Bircher Reglomat MERKUR operating instructions

Visonic MP-840 installation instructions

Visonic

Visonic MP-840 installation instructions

Texecom Prestige DT installation instructions

Texecom

Texecom Prestige DT installation instructions

LST Series 200 Specifications

LST

LST Series 200 Specifications

Chentronics iScan3 Series Operation manual

Chentronics

Chentronics iScan3 Series Operation manual

Bosch DS935 VdS installation instructions

Bosch

Bosch DS935 VdS installation instructions

Interlogix EV1012-D Series Installation sheet

Interlogix

Interlogix EV1012-D Series Installation sheet

koban KTF 8 instruction manual

koban

koban KTF 8 instruction manual

THORLABS PDA07P2 user guide

THORLABS

THORLABS PDA07P2 user guide

Greenlee 1110 instruction manual

Greenlee

Greenlee 1110 instruction manual

Vanderbilt AGB800 Instruction and installation manual

Vanderbilt

Vanderbilt AGB800 Instruction and installation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.