-17-
4-2 OPERATION CHECK
TROUBLESHOOTING
5
5-1 TROUBLESHOOTING
PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION
LEDs are not illuminated
(Transmitter/receiver)
Inappropriate power voltage Check the voltage and make sure that it is
between 10.5 and 30 VDC
Inappropriate wiring distance or wire diameter
See "2-5 WIRING DISTANCE BETWEEN POWER
SUPPLY AND DETECTOR" on page 6,check the
wiring distance.
Power supply selector setting is incorrect.
See "6-2 SOLAR BATTERY UNIT SBU-4 (OPTION)"
on page 18, check the power supply selector
setting: Normal (left), SBU-4 (right)
"ALARM" LED is not illuminated
even if the beam is blocked
Alignment level indicator LEDs are
not illuminated (Transmitter/
Receiver)
5HÀHFWLRQRIWKHÀRRURUZDOO
Block all four beams at same time
See "4-1 OPTICAL ALIGNMENT" on Page 15 and
make realignment.
See "3-3 1 4 CHANNEL BEAM FREQUENCY
SELECTOR" on Page 11 and set to the same channel.
See"4-1 OPTICAL ALIGNMENT" on Page 15 and
make realignment. If the problem persist,
see "BEAM POWER CONTROL SELECTOR"
on Page 13 and step down the beam power.
Beam has not been blocked.
Optical alignment is not optimized.
The channel setting between the Transmitter
and the Receiver does not match.
Blocking the beam, and
illuminates "ALARM" LED but
does not active the alarm.
Alarm is activated even if the beam
is not blocked
Signal line short-circuited
Alarm contact welded
Check the wiring.
Repair is required. Contact the distributor or us.
Interruption time is too short See "BEAM INTERRUPTION ADJUSTMENT"
on page 11, set an appropriate interruption time.
Frost, snow or heavy rain causes
false alarm.
Improper output
Alignment level indicator LEDs of
only the Transmitter are not
illuminated.
Optical alignment was not performed properly
Optical alignment is not optimized
The wiring is incorrect
See"4-1 OPTICAL ALIGNMENT" on Page 15 and
make realignment.
See"4-1 OPTICAL ALIGNMENT" on Page 15 and
make realignment.
Inappropriate optical alignment for the upper
beam unit.
Make correct wiring.
See"4-1 OPTICAL ALIGNMENT" on Page 15 and
make realignment.
Surface of the transmitter/receiver cover soiled Clean the cover (wipe the cover with a soft cloth
dampened with water-diluted neutral detergent)
Channels of the transmitter and receiver are different
Multiple photoelectric detector for long
distance or beam stacking applications.
Set the same channel to both the transmitter and receiver.
Set channels 1-3 or 2-4 or 1-4.
Conduct a walk to check that the alarm indicator LED on the receiver turns ON or the beep sound rings
on the receiver as the walker interrupts the beam.
Be sure to conduct a walk test (to block the infrared beam) at the following three points:
In front of the transmitter
In front of the receiver
At the middle point between the transmitter and the receiver
The detector is installed properly when the Alarm indicator LED turns ON and the
beep sound rings in the tests at all three points. A B
Transmitter Receiver
C
Conduct a walk test at least once a year.
2SHUDWLRQFKHFNFDQEHSHUIRUPHGE\WKHEHHSVRXQGDWLQWHUUXSWLRQIRUPLQXWHVRIWKHWDPSHUEXWWRQRQERWKWKHWUDQVPLWWHUDQG
receiver are pressed (the covers are closed).
Note>>
A
B
C