BS-1SIREN
High PowerSiren With
BatteryBack-up and Flashlight
INSTALLATIONINSTRUCTIONS&USERMANUAL
BS-1Features
The BS-1siren isanewgeneration ofprofessional
high poweracousticsiren withbatteryback-up and
flashlight, whichinclude all performanceand reliability
forsecurityalarmsystem.
Features:
Outdoorbatteryback-up siren withflashlight.
Doublehousing:External–3mm plastic
PCwithUV,Internal–0.8mm metal.
Continuousfrequency modulated sound.
Tamperprotection in3ways –Screwor
Coveropening ortearing housing fromthe wall.
Positiveand negativealarmtriggerinputs.
Triggerinputtoactivateonlythe flashlight.
Siren period can setasfollowtriggeror3min
cutoff
Selectorforlamporxenon
Alarmbymainpowerfailure.
Protecting againsttotallybatterydischarge.
Plug Terminalforeasy Installation.
Environmentalimmunity.
FunctionalDescription AlarmTrigger:
The alarmcan be triggered byapplying high orlow
voltage tothe “GO+”or“GO-“ inputsterminals
respectively.The sound and flashlighttriggered
together.
Alarmsiren duration depended on the Triggerselector
state:
F.T-FollowTrigger.
TMR-siren cutoff after3minutes,thisstateis
recommended inordertoavoidviolation ofany
localregulations.
FlashTrigger:
The flashlightcan be triggered byapplying “low”
levelto“FL-“ terminal.Flashduration isnotlimited
and the timeofflashlightissetbycontrolpanel-as
long astriggeravailablethe flashlightwill be active
Tamper:
The tamperisnormallyclosed whilethe housing is
closed withthe screw,sointhisstatethe tamper
terminalsareshorted (0Ohm).The tamperwill open
whileopening the screworbytearing the housing
fromthe wall.
Note:It’sessentialtoscrewthe tampersocketto
the wall properly.
PowerFailure:
OnPowerFailurethe siren and flashlightare
triggering,until powersupplyisrestored ortimeout
period (5minutes)expires.
BatteryProtection
The Siren issupplied withprotection againsttotally
batterydischarge bycutting off the siren,when
voltage levelfallsdowntoless then 8Vdc.
Installation Instructions
1.Choosethe mounting location forthe siren –
the wall mustbe even and free ofholesand
excessiveprotrusions.
2.Markand drill 5holeswiththe helpofthe attach
drill patternplate(4holesforthe housing base
and 1forthe tamper).
Note:Takeaconsideration aboutthe wires
inputsinthe housing base.
Siren BS-1ManualInstallation
-1-
ELECTRONIC ENGINEERING LTD.