Quick Reference 931602A © 2019, CyberData Corporation, ALL RIGHTS RESERVED© 2019, CyberData Corporation, ALL RIGHTS RESERVED 931602A Quick Reference
Wall Mounting Options
Gang Box Mounting Options
Mounting Screw &
Wall Cutout
on Wall
Pre Drill Holes
to J1
Cable
Network
Backplate
Plastic Ribbed Anchor
Remove Screw & Nut
Before Install to Wall
Mounting
Screw (3x)
Loop Wire
Clockwise
Wire
Ground
Wire
Ground
Closed
Slots
Slots
Opening
Slot
Entry
Cable
Wall Cutout
or Two Gang Box
Backplate accept
Single Gang Box
Backplate
Wall Cutout
Wire
Ground
Two Gang Box use four
Single Gang Box use two
Screw Accessory Kit
In Two Gang Box Mounting
Move Ground Cable to Center Hole
Remove Screw & Nut
Before Install to Gang Box
Mounting
Screw (3x)
Loop Wire
Clockwise
Wire
Ground
Cable
Network
Closed
Slots
Cable
Slot
Entry
Cable
Getting Started
• Download the Operations Guide PDF file, from the Downloads tab at the following webpage:
https://www.cyberdata.net/products/011211
• Create a plan for the locations of your devices.
• WARNING: This product should be installed by a licensed electrician according to all local electrical and building codes.
• WARNING: To prevent injury, this apparatus must be securely attached to the floor/wall in accordance with the installation
instructions.
• WARNING: The PoE connector is intended for intra-building connections only and does not route to the outside plant.
• WARNING: This enclosure is not rated for any AC voltages!
Parts
Contacting CyberData
Parameter Factory Default Setting
IP Addressing DHCP
IP Addressa10.10.10.10
Web Access Username admin
Web Access Password admin
Subnet Maska255.0.0.0
Default Gatewaya10.0.0.1
a. Default if there is not a DHCP server present.
(4) Plastic Ribbed Anchor (4) #6-32 FlatHead Countersunk
Machine Screw
(1) Wall Mounting Kit(1) Intercom Assembly (1) Gang Box Mounting Kit
(4) Sheet Metal Screw
Sales: (831) 373-2601 ext. 334
Support: 831-373-2601 ext. 333
Support Website: http://support.cyberdata.net/
RMA Department: (831) 373-2601 ext. 136
RMA Email: [email protected]
RMA Status: http://support.cyberdata.net/
Warranty Information: http://support.cyberdata.net/
Corporate Headquarters
CyberData Corporation
3 Justin Court
Monterey, CA 93940, USA
Phone: 831-373-2601
Fax: 831-373-4193
http://www.cyberdata.net/
The IP Endpoint Company
Installation Quick Reference
SIP Indoor Intercom
SIP Compliant
011211*, RAL 9003, Signal White
*Replaces the 011111 number.
© 2019, CyberData Corporation, ALL RIGHTS RESERVED 931602A Quick Reference Quick Reference 931602A © 2019, CyberData Corporation, ALL RIGHTS RESERVED
RTFM Button
Maximum Recommended Wall Cutout Dimensions
RTFM button (SW1)
When the device is operational and linked to a net-
work, you can use the Reset Test Function Man-
agement (RTFM) button (SW1 [see picture]) to
announce the device’s IP address or restore the
device to the factory
default settings.
To announce the device’s current IP address:
• Press and release the RTFM button within a
five second window.
Note The device will use DHCP to obtain the
new IP address (DHCP-assigned address
or default to 10.10.10.10 if a DHCP server
is not present).
To restore the device to factory default settings:
• Press and hold the RTFM button for longer
than five seconds until you hear the device
announce that it is restoring the factory default
settings.
DIMENSIONS ARE IN INCHES [MILLIMETER]
3.40 [86.4]
ø0.19 [ø4.8]
2.39 [60.8]
3.40 [86.4]
2.65 [67.3]
0.50 [12.8]
0.38 [9.5]
(4 Places)
Dimensions
Terminal Block Connections
4.53 [115.0]
4.53 [115.0]
DIMENSIONS ARE IN INCHES [MILLIMETER]
2.14 [54.3]
1
8
Wire (IN)
Tin Leads
Approx. 1/4” or
6mm
Terminal Block
can accept 16 AWG wire
Alternate Power Input:
1 = +8 to +12VDC @ 1000mA Regulated Power Supply*
2 = Power Ground*
Relay Contact:
(1 A at 30 VDC for continuous loads)
3 = Relay Common
4 = Relay Normally Open Contact
5 = Sense Input
6 = Sense Ground
7 = Remote Switch "A"
8 = Remote Switch "B"
*Contacts 1 and 2 on the terminal block are only for
powering the device from a non-PoE 12VDC power
source as an alternative to Network PoE power. Use of
these contacts for any other purpose will damage the
device and void the product warranty.
34
Use a 3.17 mm (1/8-inch) flat blade
screwdriver for the terminal block screws

Other manuals for 011211 series

3

Other CyberData Intercom System manuals

CyberData VoIP Intercom 010935B Manual

CyberData

CyberData VoIP Intercom 010935B Manual

CyberData 11113 User manual

CyberData

CyberData 11113 User manual

CyberData 11307 User manual

CyberData

CyberData 11307 User manual

CyberData 11209 User manual

CyberData

CyberData 11209 User manual

CyberData 011211 series Manual

CyberData

CyberData 011211 series Manual

CyberData VoIP Intercom 010935B User manual

CyberData

CyberData VoIP Intercom 010935B User manual

CyberData 011214 Manual

CyberData

CyberData 011214 Manual

CyberData 11214 User manual

CyberData

CyberData 11214 User manual

CyberData VoIP Indoor Intercom 011030 Manual

CyberData

CyberData VoIP Indoor Intercom 011030 Manual

CyberData 011186 User manual

CyberData

CyberData 011186 User manual

CyberData 011306 Manual

CyberData

CyberData 011306 Manual

CyberData 11209 Manual

CyberData

CyberData 11209 Manual

CyberData 11186 User manual

CyberData

CyberData 11186 User manual

CyberData 11113 User manual

CyberData

CyberData 11113 User manual

CyberData 011478 Manual

CyberData

CyberData 011478 Manual

CyberData 11304 Manual

CyberData

CyberData 11304 Manual

CyberData 11310 Manual

CyberData

CyberData 11310 Manual

CyberData 011414 User manual

CyberData

CyberData 011414 User manual

CyberData 011211 series Manual

CyberData

CyberData 011211 series Manual

CyberData 11035 User manual

CyberData

CyberData 11035 User manual

CyberData VoIP Indoor Intercom 011030 User manual

CyberData

CyberData VoIP Indoor Intercom 011030 User manual

CyberData 011410 Manual

CyberData

CyberData 011410 Manual

CyberData #011123 Manual

CyberData

CyberData #011123 Manual

CyberData #011123 Manual

CyberData

CyberData #011123 Manual

Popular Intercom System manuals by other brands

Telex BTR-24 User instructions

Telex

Telex BTR-24 User instructions

Bell System bellissimo Installation & operation manual

Bell System

Bell System bellissimo Installation & operation manual

Bpt BVKIT Connection examples

Bpt

Bpt BVKIT Connection examples

Aiphone AP-10M Operation manual

Aiphone

Aiphone AP-10M Operation manual

Upgrading everyday security Commpact user manual

Upgrading everyday security

Upgrading everyday security Commpact user manual

Byron DIC-24122 instruction manual

Byron

Byron DIC-24122 instruction manual

Nexx SX.COM user guide

Nexx

Nexx SX.COM user guide

AVE DOMINA Smart VI-PEAUX manual

AVE

AVE DOMINA Smart VI-PEAUX manual

Alcad GRF-302 manual

Alcad

Alcad GRF-302 manual

Commax CDV-43Q user manual

Commax

Commax CDV-43Q user manual

urmet domus 956/94 Installation and instruction manual

urmet domus

urmet domus 956/94 Installation and instruction manual

Avidsen ELIA manual

Avidsen

Avidsen ELIA manual

Fermax FVQ-6020APP Installer manual

Fermax

Fermax FVQ-6020APP Installer manual

GTO F3101MBC manual

GTO

GTO F3101MBC manual

IDTECK Star RFK101 user manual

IDTECK

IDTECK Star RFK101 user manual

Akuvox C317A quick guide

Akuvox

Akuvox C317A quick guide

Commax CDV-50 Use and care guide

Commax

Commax CDV-50 Use and care guide

Fermax DUOX MARINE Series Installer manual

Fermax

Fermax DUOX MARINE Series Installer manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.