manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. CyberData
  6. •
  7. Intercom System
  8. •
  9. CyberData 011211 series Manual

CyberData 011211 series Manual

Quick Reference 931602A © 2019, CyberData Corporation, ALL RIGHTS RESERVED© 2019, CyberData Corporation, ALL RIGHTS RESERVED 931602A Quick Reference
Wall Mounting Options
Gang Box Mounting Options
Mounting Screw &
Wall Cutout
on Wall
Pre Drill Holes
to J1
Cable
Network
Backplate
Plastic Ribbed Anchor
Remove Screw & Nut
Before Install to Wall
Mounting
Screw (3x)
Loop Wire
Clockwise
Wire
Ground
Wire
Ground
Closed
Slots
Slots
Opening
Slot
Entry
Cable
Wall Cutout
or Two Gang Box
Backplate accept
Single Gang Box
Backplate
Wall Cutout
Wire
Ground
Two Gang Box use four
Single Gang Box use two
Screw Accessory Kit
In Two Gang Box Mounting
Move Ground Cable to Center Hole
Remove Screw & Nut
Before Install to Gang Box
Mounting
Screw (3x)
Loop Wire
Clockwise
Wire
Ground
Cable
Network
Closed
Slots
Cable
Slot
Entry
Cable
Getting Started
• Download the Operations Guide PDF file, from the Downloads tab at the following webpage:
https://www.cyberdata.net/products/011211
• Create a plan for the locations of your devices.
• WARNING: This product should be installed by a licensed electrician according to all local electrical and building codes.
• WARNING: To prevent injury, this apparatus must be securely attached to the floor/wall in accordance with the installation
instructions.
• WARNING: The PoE connector is intended for intra-building connections only and does not route to the outside plant.
• WARNING: This enclosure is not rated for any AC voltages!
Parts
Contacting CyberData
Parameter Factory Default Setting
IP Addressing DHCP
IP Addressa10.10.10.10
Web Access Username admin
Web Access Password admin
Subnet Maska255.0.0.0
Default Gatewaya10.0.0.1
a. Default if there is not a DHCP server present.
(4) Plastic Ribbed Anchor (4) #6-32 FlatHead Countersunk
Machine Screw
(1) Wall Mounting Kit(1) Intercom Assembly (1) Gang Box Mounting Kit
(4) Sheet Metal Screw
Sales: (831) 373-2601 ext. 334
Support: 831-373-2601 ext. 333
Support Website: http://support.cyberdata.net/
RMA Department: (831) 373-2601 ext. 136
RMA Email: [email protected]
RMA Status: http://support.cyberdata.net/
Warranty Information: http://support.cyberdata.net/
Corporate Headquarters
CyberData Corporation
3 Justin Court
Monterey, CA 93940, USA
Phone: 831-373-2601
Fax: 831-373-4193
http://www.cyberdata.net/
The IP Endpoint Company
Installation Quick Reference
SIP Indoor Intercom
SIP Compliant
011211*, RAL 9003, Signal White
*Replaces the 011111 number.
© 2019, CyberData Corporation, ALL RIGHTS RESERVED 931602A Quick Reference Quick Reference 931602A © 2019, CyberData Corporation, ALL RIGHTS RESERVED
RTFM Button
Maximum Recommended Wall Cutout Dimensions
RTFM button (SW1)
When the device is operational and linked to a net-
work, you can use the Reset Test Function Man-
agement (RTFM) button (SW1 [see picture]) to
announce the device’s IP address or restore the
device to the factory
default settings.
To announce the device’s current IP address:
• Press and release the RTFM button within a
five second window.
Note The device will use DHCP to obtain the
new IP address (DHCP-assigned address
or default to 10.10.10.10 if a DHCP server
is not present).
To restore the device to factory default settings:
• Press and hold the RTFM button for longer
than five seconds until you hear the device
announce that it is restoring the factory default
settings.
DIMENSIONS ARE IN INCHES [MILLIMETER]
3.40 [86.4]
ø0.19 [ø4.8]
2.39 [60.8]
3.40 [86.4]
2.65 [67.3]
0.50 [12.8]
0.38 [9.5]
(4 Places)
Dimensions
Terminal Block Connections
4.53 [115.0]
4.53 [115.0]
DIMENSIONS ARE IN INCHES [MILLIMETER]
2.14 [54.3]
1
8
Wire (IN)
Tin Leads
Approx. 1/4” or
6mm
Terminal Block
can accept 16 AWG wire
Alternate Power Input:
1 = +8 to +12VDC @ 1000mA Regulated Power Supply*
2 = Power Ground*
Relay Contact:
(1 A at 30 VDC for continuous loads)
3 = Relay Common
4 = Relay Normally Open Contact
5 = Sense Input
6 = Sense Ground
7 = Remote Switch "A"
8 = Remote Switch "B"
*Contacts 1 and 2 on the terminal block are only for
powering the device from a non-PoE 12VDC power
source as an alternative to Network PoE power. Use of
these contacts for any other purpose will damage the
device and void the product warranty.
34
Use a 3.17 mm (1/8-inch) flat blade
screwdriver for the terminal block screws

Other manuals for 011211 series

3

Other CyberData Intercom System manuals

CyberData 11111 User manual

CyberData

CyberData 11111 User manual

CyberData 011414 User manual

CyberData

CyberData 011414 User manual

CyberData 011414 Manual

CyberData

CyberData 011414 Manual

CyberData 11272 Manual

CyberData

CyberData 11272 Manual

CyberData 11307 User manual

CyberData

CyberData 11307 User manual

CyberData 11214 Manual

CyberData

CyberData 11214 Manual

CyberData 11310 User manual

CyberData

CyberData 11310 User manual

CyberData 11308 Manual

CyberData

CyberData 11308 Manual

CyberData 11307 User manual

CyberData

CyberData 11307 User manual

CyberData 011211x User manual

CyberData

CyberData 011211x User manual

CyberData 011035 Manual

CyberData

CyberData 011035 Manual

CyberData 11214 Manual

CyberData

CyberData 11214 Manual

CyberData 11214 User manual

CyberData

CyberData 11214 User manual

CyberData VoIP Intercom 010935B Manual

CyberData

CyberData VoIP Intercom 010935B Manual

CyberData 11186 Manual

CyberData

CyberData 11186 Manual

CyberData 11186 User manual

CyberData

CyberData 11186 User manual

CyberData 11186 User manual

CyberData

CyberData 11186 User manual

CyberData RAL 9003 Manual

CyberData

CyberData RAL 9003 Manual

CyberData VoIP Indoor Intercom 011030 Manual

CyberData

CyberData VoIP Indoor Intercom 011030 Manual

CyberData RAL 9003 User manual

CyberData

CyberData RAL 9003 User manual

CyberData 11186 User manual

CyberData

CyberData 11186 User manual

CyberData 11304 Manual

CyberData

CyberData 11304 Manual

CyberData 011306 Manual

CyberData

CyberData 011306 Manual

CyberData 011211 series Manual

CyberData

CyberData 011211 series Manual

Popular Intercom System manuals by other brands

Greenice EC-CAR-300 instructions

Greenice

Greenice EC-CAR-300 instructions

Somogyi home DPV 27 instruction manual

Somogyi

Somogyi home DPV 27 instruction manual

Filo GM-20P instruction manual

Filo

Filo GM-20P instruction manual

DoorKing 1835 owner's manual

DoorKing

DoorKing 1835 owner's manual

golmar Rock Series installation manual

golmar

golmar Rock Series installation manual

golmar Platea Uno Installation

golmar

golmar Platea Uno Installation

Aiphone LEF-3C Operation manual

Aiphone

Aiphone LEF-3C Operation manual

Aiphone NE-NVP-RA Specifications

Aiphone

Aiphone NE-NVP-RA Specifications

Vimar ELVOX K40505.R Installer manual

Vimar

Vimar ELVOX K40505.R Installer manual

Aiphone JKW-IP quick start guide

Aiphone

Aiphone JKW-IP quick start guide

PROLYNX PL-VDO03M user manual

PROLYNX

PROLYNX PL-VDO03M user manual

TekTone Tek-SELECT II SM401 Operation, installation and service manual

TekTone

TekTone Tek-SELECT II SM401 Operation, installation and service manual

Valcom VE9894-1-Finish Specifications

Valcom

Valcom VE9894-1-Finish Specifications

CDVI CD97-4ID user manual

CDVI

CDVI CD97-4ID user manual

Siedle BTSV 850-02 operating instructions

Siedle

Siedle BTSV 850-02 operating instructions

Eclipse V12LD user guide

Eclipse

Eclipse V12LD user guide

Alphatech GSM-Variobell user manual

Alphatech

Alphatech GSM-Variobell user manual

Niko 10-285 manual

Niko

Niko 10-285 manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.