manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. CyberData
  6. •
  7. Speakers
  8. •
  9. CyberData 011216 Manual

CyberData 011216 Manual

Other manuals for 011216

1

Other CyberData Speakers manuals

CyberData 011121 Manual

CyberData

CyberData 011121 Manual

CyberData 11021 User manual

CyberData

CyberData 11021 User manual

CyberData 11180 Manual

CyberData

CyberData 11180 Manual

CyberData 11098 Manual

CyberData

CyberData 11098 Manual

CyberData 010844D User manual

CyberData

CyberData 010844D User manual

CyberData 011120 Manual

CyberData

CyberData 011120 Manual

CyberData 011394 SERIES User manual

CyberData

CyberData 011394 SERIES User manual

CyberData Alteva User manual

CyberData

CyberData Alteva User manual

CyberData 11180 User manual

CyberData

CyberData 11180 User manual

CyberData 11021 User manual

CyberData

CyberData 11021 User manual

CyberData 011504 Manual

CyberData

CyberData 011504 Manual

CyberData 011589 Manual

CyberData

CyberData 011589 Manual

CyberData 11103 User manual

CyberData

CyberData 11103 User manual

CyberData 10844 User manual

CyberData

CyberData 10844 User manual

CyberData 011185 User manual

CyberData

CyberData 011185 User manual

CyberData 011121 Manual

CyberData

CyberData 011121 Manual

CyberData 11098 User manual

CyberData

CyberData 11098 User manual

CyberData 011401 Manual

CyberData

CyberData 011401 Manual

CyberData 011401 Manual

CyberData

CyberData 011401 Manual

CyberData 011394 SERIES User manual

CyberData

CyberData 011394 SERIES User manual

CyberData 011487 Manual

CyberData

CyberData 011487 Manual

CyberData VoIP Ceiling Speaker User manual

CyberData

CyberData VoIP Ceiling Speaker User manual

CyberData 011396 User manual

CyberData

CyberData 011396 User manual

CyberData 11182 User manual

CyberData

CyberData 11182 User manual

Popular Speakers manuals by other brands

Electro-Voice LR4S engineering data

Electro-Voice

Electro-Voice LR4S engineering data

Definitive Technology Sound Cylinder user guide

Definitive Technology

Definitive Technology Sound Cylinder user guide

AudioSource LS545 user manual

AudioSource

AudioSource LS545 user manual

Paso C402-T Instructions for use

Paso

Paso C402-T Instructions for use

Altec Lansing 416-8C LF SPEAKER manual

Altec Lansing

Altec Lansing 416-8C LF SPEAKER manual

Kenwood KFC-1072 Servise manual

Kenwood

Kenwood KFC-1072 Servise manual

Peavey ProSys 112 user guide

Peavey

Peavey ProSys 112 user guide

JBL Control Contractor 60 Series installation instructions

JBL

JBL Control Contractor 60 Series installation instructions

Aura STORM-8 owner's manual

Aura

Aura STORM-8 owner's manual

Oontz ANGLE 3 PLUS quick start guide

Oontz

Oontz ANGLE 3 PLUS quick start guide

Electro-Voice LR4A engineering data

Electro-Voice

Electro-Voice LR4A engineering data

Rave RK-650-ICA-B owner's manual

Rave

Rave RK-650-ICA-B owner's manual

Flux Reference Series installation manual

Flux

Flux Reference Series installation manual

Lanzar AQAWBS64BK installation manual

Lanzar

Lanzar AQAWBS64BK installation manual

DAPAudio DCS-6230 manual

DAPAudio

DAPAudio DCS-6230 manual

Aluratek ABS03F quick start guide

Aluratek

Aluratek ABS03F quick start guide

Kenwood KES-5A instruction manual

Kenwood

Kenwood KES-5A instruction manual

Sonance ORIGINAL SERIES instruction manual

Sonance

Sonance ORIGINAL SERIES instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Quick Reference 931558B © 2022, CyberData Corporation, ALL RIGHTS RESERVED© 2022, CyberData Corporation, ALL RIGHTS RESERVED 931558B Quick Reference
Wall Mounting Options
Gang Box Mounting Options
Contacting CyberData
Backplate
Wall
Mounting
Screw (3x)
(Not Provided)
Network Cable &
for Ground Wire Connection
Pick One of Four Mounting Hole
Screw
121001A
Accessory Kit
(4 Places) on Wall
Pre Drill Holes
Ground Wire
Cutout
Slot
Entry
Cable
Closed
Slots
Cable
Two Gang Box use four
Wall Cutout
or Two Gang Box
Backplate accept
Single Gang Box
Single Gang Box use two
Backplate
Wall Cutout
121002B
Screw Accessory Kit
Mounting
Screw (3x)
(Not Provided)
Ground Wire
Any Available Mounting Hole
Ground Wire Connect to
(Not Provided)
Network Cable
Slot
Entry
Cable
Closed
Slots
Cable
Sales: 831-373-2601 ext. 334
Support: 831-373-2601 ext. 333
Support Website: https://support.cyberdata.net/
RMA Department Contact and Status: https://support.cyberdata.net/
Warranty Information: https://support.cyberdata.net/
Corporate Headquarters
CyberData Corporation
3 Justin Court
Monterey, CA 93940, USA
Phone: 831-373-2601
Fax: 831-373-4193
https://www.cyberdata.net/
Typical System Installation
Getting Started
• Download the Operations Guide PDF file, from the Downloads tab at the following webpage:
https://www.cyberdata.net/products/011216
• Create a plan for the locations of your Office Ringers.
• WARNING: This product should be installed by a licensed electrician according to all local electrical and building codes.
• WARNING: To prevent injury, this apparatus must be securely attached to the floor/wall in accordance with the installation
instructions.
• WARNING: The PoE connector is intended for intra-building connections only and does not route to the outside plant.
• WARNING: This enclosure is not rated for any AC voltages!
Parts
Parameter Factory Default Setting
IP Addressing DHCP
IP Addressa
a. Default if there is not a DHCP server present.
IPv4 Link Local
Web Access Username admin
Web Access Password admin
Subnet MaskaIPv4 Link Local
Default GatewayaIPv4 Link Local
802.3af Compliant Ethernet Switch
SIP Office Ringer IP Phone IP PBX ServerSIP Office Ringer SIP Office Ringer
*More installation and mounting
options are available in the
Operations Guide.
(4) #6 x 1.25-inch
Sheet Metal Screw
(4) Plastic ribbed anchor (4) 6-32 x 0.5-inch flat
undercut Phillips machine
screw
(1) Office Ringer Assembly (1) Wall Mounting Kit (1) Gang Box Mounting Kit
The IP Endpoint Company
Installation Quick Reference
SIP Office Ringer
SIP Compliant
011216
© 2022, CyberData Corporation, ALL RIGHTS RESERVED 931558B Quick Reference Quick Reference 931558B © 2022, CyberData Corporation, ALL RIGHTS RESERVED
RTFM Button
Terminal Block Connections
Plug in the Network Cable and Create Service Loop
RTFM button (SW1)
When the device is operational and linked to a network,
you can use the Reset Test Function Management
(RTFM) button (SW1 [see picture]) to announce the
device’s IP address or restore the device to the factory
default settings.
To announce the device’s current IP address:
• Press and release the RTFM button within a five
second window.
Note The device will use DHCP to obtain the new IP
address (DHCP-assigned address or default to
IPv4 Link Local if a DHCP server is not
present).
To restore the device to factory default settings:
• Press and hold the RTFM button for longer than five
seconds until you hear the device announce that it is
Alternate Power Input:
1 = +8 to +12VDC @ 1000mA Regulated Power Supply*
2 = Power Ground*
Relay Contact:
(1 A at 30 VDC for continuous loads)
3 = Relay Common
4 = Relay Normally Open Contact
5 = Sense Input
6 = Sense Ground
7 = Remote Switch "A"
8 = Remote Switch "B"
*Contacts 1 and 2 on the terminal block are only for powering the
device from a non-PoE 12VDC power source as an alternative to
Network PoE power. Use of these contacts for any other purpose will
damage the device and void the product warranty.
34
1
8
Wire (IN)
Tin Leads
Approx. 1/4” or
6mm
Terminal Block
can accept 16 AWG wire
Use a 3.17 mm (1/8-inch) flat blade
screwdriver for the terminal block screws
Two (2)
Cable Entry Slot
Two (2)
Cable Entry Slot
One (1)
Cable Entry Slot
Mounting
Screw (3x)
Create
Service Loop
Before Closing
Network
Connector
Network Cable
Backplate
Faceplate
Assembly
When Use in
Auxiliary Strobe
P/N: 011288A
(Sold Separately)
Conjunction with
Dimensions
Dimensions for Wall Mounting and One / Two Gang Box Mounting
4.53 [115.0]
4.53 [115.0]
DIMENSIONS ARE IN INCHES [MILLIMETER]
2.14 [54.3]
Dimensions Are in Inch [Millimeter]
Ø0.188 [Ø4.8]
Ø0.189 [Ø4.8]
0.910 [23.1]
3.400 [86.4]
3.280 [83.3]
3.400 [86.4]
1.820 [46.2]
Through Hole
Through Hole
82° Countersunk
= Slot Open
= Slot Close
Fits One/Two Gang Box
(6 Places)
*
*
*
3.150 [80.0]
2.895 [73.5]
(4 Places)
Cut Hole for Cable Through