* Door/Window Report:
When the door/window state changed, the device will unsolicited to
send the report to the nodes in the group 1.
Notification Report (V4)
Notification T pe: Access Control (0x06)
Event: Door/Window is open (0x16)
Door/Window is closed (0x17)
Sensor Binar Report (V2)
Sensor T pe: Door/Window (0x0A)
Sensor Value: 0x00 is closed, 0xFF is opened.
* Tamper Report:
Both the 2 tamper ke s are pressed over 5 seconds. The device will
into the alarm state. In that state, if an one of the tamper ke s be
released, the device will unsolicited to send the report to the nodes in
the group 1.
Notification Report (V4)
Notification T pe: Home Securit (0x07)
Event: Tampering. Product covering removed (0x03)
Sensor Binar Report (V2)
Sensor T pe: Tamper (0x08)
Sensor Value: 0xFF
In the default, when the temperature is changed to plus or minus one
degree Fahrenheit (0.56 degree Celsius), the device will report
temperature information to the nodes in the group 1.
The device will measure the temperature in ever one minute. And if
the temperature is over 140 degree Fahrenheit (60 degree Celsius), the
device will alwa s report in each measurement.
* Timing Report:
Beside the event triggered could report message, the device also
support the timing unsolicited report of the status.
•Batter level report: Ever 6 hours report once in default.
It could be changed b setting the configuration NO. 10.
•Low batter report: When the batter level is too low, ever 30
minutes will report once.
•Door/window state report: Ever 6 hours report once in default.
It could be changed b setting the configuration NO. 11.
•Illumination level report: Ever 6 hours report once in default.
It could be changed b setting the configuration NO. 12.
•Temperature report: Ever 6 hours report once in default.
It could be changed b setting the configuration NO. 13.
Notice: The configuration NO. 10, 11, 12 and 13 could be setting to
zero to disable the auto report. And the configuration NO. 20 could
change the tick interval, the default value is 30, if setting to 1, that
means the minimum auto report interval will be one minute. And please
notice if setting this value to zero, that means disable all of the timing
report except the low batter detection.
Power Up Procedure
* Battery Power Check
When the device power up, the device will detect the power level of the
batter immediatel . If the power level is too low, the LED will continue
flash about 5 seconds. Please change another new batter .
* NW
When the device power on, the device will check is it alread adding to
the network? If doesn't, it will auto start the NWI mode. The LED will
flash in ever second and continue 30 seconds. Until timeout or the
device successful to inclusion b controller. The use can presses the
tamper ke 3 times to abort the NWI mode.
3