Digi DI-600 User manual

OPERATION MANUAL
Model: DI-600
Edition Month Year
1st August 2002
2nd
3rd
4th
5th
SHANGHAI TERAOKA ELECTRONIC Co., Ltd. --- Technical Support Dept.
A/18F East Tower, New Hua Lian Building,755# Huai Hai Zhong Road, Shanghai China 200020
Tel: +86-21-64739918 Fax: +86-21-54901934 E-mail: steservice@digi-scale.com
All manuals and user guides at all-guides.com
all-guides.com

DI-600 Operation Manual
1
CONTENTS
1. General Specification
1.1. Specifications -------------------------------------------------------------------------------------------------- 1
1.2. Features -------------------------------------------------------------------------------------------------------- 1
1.2.1. Indicators -------------------------------------------------------------------------------------------------- 1
1.2.2. Battery Indicator ----------------------------------------------------------------------------------------- 1
1.2.3. Interface --------------------------------------------------------------------------------------------------- 1
1.2.4. Printer ------------------------------------------------------------------------------------------------------ 1
1.2.5. Load Cell -------------------------------------------------------------------------------------------------- 2
1.2.6. Housing ---------------------------------------------------------------------------------------------------- 2
1.2.7. Calibration ------------------------------------------------------------------------------------------------ 2
1.2.8. Power Source -------------------------------------------------------------------------------------------- 2
1.2.9. Rechargeable Battery Specification ---------------------------------------------------------------- 2
1.2.10. Operation Condition ------------------------------------------------------------------------------------2
1.3. Main Functions ------------------------------------------------------------------------------------------------ 2
1.4. Overall View --------------------------------------------------------------------------------------------------- 2
1.4.1. Layout & Dimension ------------------------------------------------------------------------------------ 2
1.4.2. Display Panel -------------------------------------------------------------------------------------------- 3
1.5. Keyboard & Display Layout and Function -------------------------------------------------------------- 3
1.5.1. Indicators -------------------------------------------------------------------------------------------------- 3
1.5.2. Keyboard -------------------------------------------------------------------------------------------------- 4
1.6. Hardware ------------------------------------------------------------------------------------------------------- 4
2. Main Operation
2.1. Power On ------------------------------------------------------------------------------------------------------- 5
2.2. Power Off ------------------------------------------------------------------------------------------------------- 5
2.3. One Touch Tare ----------------------------------------------------------------------------------------------- 5
2.4. Digital Tare ----------------------------------------------------------------------------------------------------- 5
2.5. Tare Clear ------------------------------------------------------------------------------------------------------ 6
2.6. Date and Time Setting -------------------------------------------------------------------------------------- 6
2.7. Date and Time Recall --------------------------------------------------------------------------------------- 6
2.8. Grand Total Data Clear -------------------------------------------------------------------------------------- 7
2.8.1. Weight Grand Total Clear ----------------------------------------------------------------------------- 7
2.8.2. Quantity Grand Total Clear --------------------------------------------------------------------------- 7
2.9. Serial Number Setup ---------------------------------------------------------------------------------------- 7
2.10. Weight Unit Conversion ----------------------------------------------------------------------------------- 8
2.11. Set Point Value Setting & S. Memory Recall --------------------------------------------------------- 8
2.11.1. Set Point Value Setting ------------------------------------------------------------------------------- 8
2.11.2. Set Point Value Recall -------------------------------------------------------------------------------- 9
2.11.3. Set-Point Check and Alarm Mode Select -------------------------------------------------------- 9
2.11.4. Weight Check Bar of Set-Point --------------------------------------------------------------------- 10
All manuals and user guides at all-guides.com

2.12. Counting Mode ----------------------------------------------------------------------------------------------- 11
2.12.1. Key Entry Quantity ------------------------------------------------------------------------------------ 11
2.12.2. Sample Quantity Setting ----------------------------------------------------------------------------- 11
2.12.3. Sample Quantity Modification and Print Receipt ---------------------------------------------- 11
2.13. Accumulation Operation ----------------------------------------------------------------------------------- 12
2.13.1. WeightAccumulation --------------------------------------------------------------------------------- 12
2.13.2. Quantity Accumulation ------------------------------------------------------------------------------- 13
2.14. Grand Total Check and Print ----------------------------------------------------------------------------- 14
2.15. Printed Ticket Sample ------------------------------------------------------------------------------------- 14
3. Error Message
3.1. Error Message List & Solution ---------------------------------------------------------------------------- 15
4. Interface & Protocol
4.1. Load Cell Connector ----------------------------------------------------------------------------------------- 16
4.2. RS-232C Port ------------------------------------------------------------------------------------------------- 16
4.2.1. RS-232C Cable Connection ------------------------------------------------------------------------- 16
4.2.2. RS-232 Protocol ---------------------------------------------------------------------------------------- 17
4.3. Set-Point Connector ----------------------------------------------------------------------------------------- 20
4.3.1. Set-Point Control Cable Specification ------------------------------------------------------------- 20
4.3.2. Set-Point Port Specification -------------------------------------------------------------------------- 20
4.3.3. Set-Point Signal ON Timing -------------------------------------------------------------------------- 20
4.3.4. Set-Point Output Control ------------------------------------------------------------------------------ 21
All manuals and user guides at all-guides.com

DI-600 Operation Manual
1. General Specification
1.1. Specifications
zModel Name : DI-600
zDisplay Resolution : 1/1,000, 1/1,500, 1/2,000, 1/2,500, 1/3,000, 1/4,000, 1/5,000,
1/6,000, 1/7,500, 1/10,000, 1/15,000, 1/20,000, 1/25,000, 1/30,000
zInternal Resolution : 1/1,000,000 (Max)
zNon-linearity : <0.008% FS ( Just only include the indicator)
zCapacity Weight : Input when calibrating
zDisplay : 8 Segment 6 digits High density LCD GD-586. (With back-light)
zOverall Dimensions : 280mm (L) x 200mm(W) x 118mm(H)
1.2. Features
1.2.1. Indicators
z4 types selectable unit symbol: g, kg, lb and PCS
z4 piece set Point Indicator symbol (OV1,OV2,OV3,OV4)
z11 class drawing display for point checking indicator.
zAnd 21 indicators for other symbols.
z1 battery indicator.
1.2.2. Battery Indicator
There are 3 levels in battery indicator to display the volume of battery
power.
Fig.6
Fig.5
Fig.4
Fig.3
Fig.2
Fig.1
zFig. 1 means battery not installed, and AC power linked only.
zFig. 2 ~ Fig. 4 shows the volume of rechargeable battery in charging or
discharging mode.
zFig. 5 means battery lower, Fig. 6 is a flash indicator will keep about 2
minutes if still using battery for power supply only, then display will auto
off.
zWhen the AC power is connected, the battery indicator will keep light
on display although the On/Off key is pressed for display off. The
battery will be kept in charging mode till the AC plugged off.
1.2.3. Interface
z1 RS-232C port
zSet point output port
z14 Pin DDK Load Cell connecter
1.2.4. Printer (Optional):
Built-in dot matrix printer with English or Chinese printing
Page No. 1
All manuals and user guides at all-guides.com

DI-600 Operation Manual
1.2.5. Load Cell:
Exiting Voltage : 12V (DC)
Sensitivity (Selectable) : 0.4mV/V ~3.5mV/V
Input impedance : 350 Ohm
Maximum number of L/C : Max. 8 pcs L/C connected in parallel (350 Ohm only)
1.2.6. Housing: New design
1.2.7. Calibration: Software Calibration
1.2.8. Power Source: AC 220V (+10%, -15%) 50/60Hz
Or recharge battery 12V 2.7AH
1.2.9. Rechargeable Specification: 12V 2.7AH
a) Continuous Usage:
z8 Hours for 1 L/C connected & printer installed but not printing when fully charged.
zOr 5 hours for 8 L/C connected & printer installed but not printing when fully
charged.
z10 hours for 1 L/C connected & no printer when fully charged.
zOr 6 hours for 8 L/C connected & no printer when fully charged.
zOr 1 hour for continuously printing.
b) Charging specification
zNormally the charging current will be about 1.2A, but it depends on how much
power remained when charging.
zPlease ensure more than 8 hours for charging.
1.2.10. Operation Condition:
Temperature: 0 - 40 ℃
Humidity: < 85 % RH
1.3. Main Functions
zBase Unit selection : kg or g
zUnit conversion : between kg and lb
zCounting mode
zWeight & Quantity data can be output via RS-232 port to PC
1.4. Overall View
1.4.1. Layout & Dimension
Page No. 2
All manuals and user guides at all-guides.com

DI-600 Operation Manual
COUNT SET CAL SP1 SP2 SP3 SP4 TOTALCHECK
OK
LOW HIGH
Okg
lb
g
MEM
00
CH
TC
1 2 3
45
78
6
9S
lb
M
DI - 600
Page No. 3
All manuals and user guides at all-guides.com
all-guides.com

DI-600 Operation Manual
1.4.2. Display Panel
DI-600
OK
MEM
O
LOW
g
kg
lb
SP2
HIGH CHECK COUNT SET SP1CAL SP3 SP4 TOTAL
SM1 SM2 SM3 SM4 SM5 ALMHOLD
OS4
OS3
OS2
OS1
1.5. Keyboard & Display Layout and Function
1.5.1. Indicators
OK
MEM
O
LOW SP2
HI GH CHECK COUNT SET SP1CAL
g
kg
lb
SP3 SP4 TOTAL
⑴
⑵
⑷
⑶
⑸
⑹
SM1 SM2 SM3 SM4 SM5 HOLD ALM
OS4
OS3
OS2
OS1
Indicator Definition & Function
(1) Stable Light on when weight is stable
(2) Zero Light on when weight display is zero and stable
(3) Tare Light on when tare weight is set
(4) Net Display value is net weight indicator.
(5) MEM Memory indicator. Light on when accumulated
(6) Weight range Weight range checking indicator
(7) Battery Battery indicator
CHECK Light on when in weight checking mode
COUNT Counter Mode
SET Data set mode
CAL Light on when perform the system calibration or spec setting
SP1,SP2,SP3,SP4 Set point indicator
TOTAL Total Weight accumulation display mode indicator.
SM1,SM2,SM3,SM4 Set point memory group by used indicator.
HOLD Display hold mode
ALM Set point alarm is “on”, when it is flash the alarm is at filling mode.
When it is light on, means at the check mode.
g ,kg ,lb Weight unit
PCS Counter unit
Page No. 4
All manuals and user guides at all-guides.com

DI-600 Operation Manual
1.5.2. Keyboard
65
4
0
C
1
023
CH 79
8
Tlb
S M
Key Function
[ On/Off] Switch the display On/Off
[ Re-Zero ] Set the weight to zero
[ Tare ] Set tare value or escape form program mode
[ Mode] Set point setting Mode →Weighing Mode change
[ Enter ] (1) Sent the data to PC.
(2) Calculate unit weight in sample quantity setting mode
[ Number ] Set code number.
[Plus] Weight addition.
[Minus] Modification total weight.
[Feed] The print paper feed
[Count] Entry counting Mode
[Check] Entry check mode and hold switch
[MEM SEL] Set point memory select (1~4)
[Unit] Switch the weight unit.
[Clear] Clear data
[Numeric] Number key
1.6. Hardware
Microcomputer : MCS 51 single microprocessor (Winbond w78e58 8 bit)
Display Drive : HT 1620
LCD Display : MODEL GD-587
A/D Board : New design A/D
Page No. 5
All manuals and user guides at all-guides.com

DI-600 Operation Manual
Page No. 5
2. Main Operation
2.1. Power On
INDICATION FLAG : ( ▼EXPRESS BRIGHT, SPARKLING )
(1) Zero (2) Net (3) STA (4) Count (5) Check (6) MEM (7) OS1(8) OS2 (9) OS3 (10) OS4
(11) Hold (12) ALM
Indicators
Operation Key Weight 12345678910 11 12 Remarks
Press [On/Off] Ke
y
di-600
First display the
Indicator model,
Ur 1.00 DisplayversionNo.
0000000
1111111
:
9999999
▼▼Segment checking
0.000 kg ▼▼Weighting mode
Note: The segment checking mode can be skipped If [Re-Zero] key pressed after power on.
2.2. Power OFF
INDICATION FLAG : ( ▼EXPRESS BRIGHT, SPARKLING )
(1) Zero (2) Net (3) STA (4) Count (5) Check (6) MEM (7) OS1(8) OS2 (9) OS3 (10) OS4
(11) Hold (12) ALM
Indicators
Operation Key Weight 12345678910 11 12 Remarks
W
eighing mode 0.000 kg ▼▼
Press [On/Off] Key
2.3. One Touch Tare
INDICATION FLAG : ( ▼EXPRESS BRIGHT, SPARKLING )
(1) Zero (2) Net (3) STA (4) Count (5) Check (6) MEM (7) OS1(8) OS2 (9) OS3 (10) OS4
(11) Hold (12) ALM
Indicators
Operation Key Weight 12345678910 11 12 Remarks
Weighing mode 0.000 kg ▼▼
Load Tare weight 2.500 kg
▼Ex: tare 2.5kg
Press [Tare] Key [ tare] 0.000 kg ▼ ▼ Back to Weighing
mode
2.4. Digital tare
INDICATION FLAG : ( ▼EXPRESS BRIGHT, SPARKLING )
(1) Zero (2) Net (3) STA (4) Count (5) Check (6) MEM (7) OS1(8) OS2 (9) OS3 (10) OS4
(11) Hold (12) ALM
Indicators
Operation Key Weight 12345678910 11 12 Remarks
Weighing mode 0.000 kg ▼▼
Enter tare weight
value (Ex: 2.5kg) [2][5][0][0] 2.500 kg
▼Using number key.
Example:2.5kg
Press [Tare] Key [ Tare] 0.000 kg ▼ ▼ Back to weighing
mode
All manuals and user guides at all-guides.com

DI-600 Operation Manual
Page No. 6
2.5. Tare Clear
INDICATION FLAG : ( ▼EXPRESS BRIGHT, SPARKLING )
(1) Zero (2) Net (3) STA (4) Count (5) Check (6) MEM (7) OS1(8) OS2 (9) OS3 (10) OS4
(11) Hold (12) ALM
Indicators
Operation Key Weight 12345678910 11 12 Remarks
Weighing mode -2.500 kg ▼ ▼ ▼
Press [Tare] key [ Tare ] 0.000 kg ▼▼
Clear tare data and
back to weighing
mode
2.6. Date and Time Setting
INDICATION FLAG : ( ▼EXPRESS BRIGHT, SPARKLING )
(1) Zero (2) Net (3) STA (4) Count (5) Check (6) MEM (7) OS1(8) OS2 (9) OS3 (10) OS4
(11) Hold (12) ALM
Indicators
Operation Key Weight 12345678910 11 12 Remarks
W
eighing mode 0.000 kg ▼▼
Press [Mode] [Mode] P. totAL
Press [Mode] [Mode] C. totAL
Input Date
(Ex: 2002.6.9)
[0][2][0]
[6][0][9]
d.Y. N. d
d.020401
d.020609
Press [Enter] Ke
y
[Enter]
t. HH-NN
t. 00-00
Input TIME
(Ex: 18:26) [1][8][2][6] t. 18-26
Press [Enter] key [Enter] S.PoInt1
Press [Tare] return
t
o weighing mode [ Tare ] 0.000 kg ▼ ▼ ▼ Escape to weighing
mode
Note: If SPEC 07 bit3=1, the clock function will be disabled.
The date format is yy-mm-dd, the time format is HH-MM, date format can be set on
SPEC18 Bit0~1.
2.7. Date & Time Recall
INDICATION FLAG : ( ▼EXPRESS BRIGHT, SPARKLING )
(1) Zero (2) Net (3) STA (4) Count (5) Check (6) MEM (7) OS1(8) OS2 (9) OS3 (10) OS4
(11) Hold (12) ALM
Indicators
Operation Key Weight 12345678910 11 12 Remarks
Weighing mode 0.000 kg ▼▼
Press [Time] key [ Time ] t. 18-26 ▼▼
At this time must be
the weigh is 0 and
total weight as
same.
Press [Date] key [ Date ] d.020618 ▼▼
Press [Tare] key [ Tare ] 0.000 kg ▼▼Return to weight
mode.
All manuals and user guides at all-guides.com

DI-600 Operation Manual
Page No. 7
2.8. Grand Total Data Clear
3.8.1. Weight Grand Total Clear
INDICATION FLAG : ( ▼EXPRESS BRIGHT, SPARKLING )
(1) Zero (2) Net (3) STA (4) Count (5) Check (6) MEM (7) OS1(8) OS2 (9) OS3 (10) OS4
(11) Hold (12) ALM
Indicators
Operation Key Weight 12345678910 11 12 Remarks
Weighing mode 0.000 kg ▼▼
Press [Mode] key [Mode ] P. totAL
12.0235
Press [Clear] key [Clear] 0.000
Press [Enter] key [Enter] C. totAL
Press [Tare] ke
y
[Tare] 0.000 kg ▼▼Escape to
weighting mode
Note: SPEC 20 Bit1 should be set as 0 to enable the grand total operation.
3.8.2. Quantity Grand Total Clear
INDICATION FLAG : (▼EXPRESS BRIGHT, SPARKLING)
(1) Zero (2) Net (3) STA (4) Count (5) Check (6) MEM (7) OS1(8) OS2 (9) OS3 (10) OS4
(11) Hold (12) ALM 8293225 13964731996
Indicators
Operation Key Weight 12345678910 11 12 Remarks
Weighing mode 0.000 kg ▼▼
Press [Mode] key [Mode ] P. totAL
Press [Mode] [Mode] C. totAL
12899
Press [Clear] key [Clear] 0
Press [Enter] key [Enter] d. Y.N.d
Press [Tare] key [ Tare ] 0.000 kg ▼▼Escape to
weighting mode
Note: SPEC 20 Bit 0 should be set as 0 to enable the quantity grand total operation.
2.9. Serial number setup
INDICATION FLAG : ( ▼EXPRESS BRIGHT, SPARKLING )
(1) Zero (2) Net (3) STA (4) Count (5) Check (6) MEM (7) OS1(8) OS2 (9) OS3 (10) OS4
(11) Hold (12) ALM
Indicators
Operation Key Weight 12345678910 11 12 Remarks
Weighing mode 0.000
kg ▼▼
Press [ # ] [ # ] C.000000 ▼▼
Input CODE
number value
[1][8][5]
[6][2][6] C.185626 ▼▼Example: the serial
code is 185626
Press [Enter] key [ENTER] 0.000 kg ▼▼Back to weighting
mode
Note: This serial number can be used for print.
All manuals and user guides at all-guides.com
all-guides.com

DI-600 Operation Manual
Page No. 8
2.10. Weight Unit Conversion
INDICATION FLAG : ( ▼EXPRESS BRIGHT, SPARKLING )
(1) Zero (2) Net (3) STA (4) Count (5) Check (6) MEM (7) OS1(8) OS2 (9) OS3 (10) OS4
(11) Hold (12) ALM
Indicators
Operation Key Weight 12345678910 11 12 Remarks
Weighing mode 0.000
kg ▼▼
1.000 kg
▼Put 1.0kg
Press [lb] key [ lb] 2.204 Lb
▼Display in lb
Press [lb] key [ lb] 1.000 kg
▼Displayinkg
Note: Set the SPEC 19 Bit 0 as 0 to enable this function.
2.11. Set Point Value Setting & S. Memory Recall
System can be set 5 groups of set-point value, each group can be registered 4 points data.
Before be use this function, we should program the group data of set point into memory first.
When the weight exceeds the first point value, the indicator OS1 will be light.
When the weight exceeds the second point values, the indicator OS1 and OS2 will be light.
When the weight exceeds the third point values, the indicator OS1, OS2 and OS3 will be light.
When the weight exceeds the fourth point values, OS1, OS2, OS3 and OS4 will be light.
2.11.1. Set Point Value Setting
INDICATION FLAG : (▼EXPRESS BRIGHT, SPARKLING)
(1) Zero (2) Net (3) STA (4) Count (5) Check (6) MEM (7) OS1(8) OS2 (9) OS3 (10) OS4
(11) Hold (12) ALM
Indicators
Operation Key Weight 12345678910 11 12 Remarks
Weighing mode 0.000 kg ▼▼
Press [M][M][M][M] [M][M]
[M][M]
S.PoInt1
6.000 kg ▼▼
▼SM1, SP1 data Set.
SM1 bright
Input value
(Ex: 1.000kg) [1][0][0][0] 1.000 kg ▼▼
▼ ▼ SP1 Value is 1 kg
Press [Enter] ke
y
[Enter]
S.PoInt2
6.000 kg ▼▼
▼SM1, SP2 data Set.
SM1 bright
Input number value
(Example: 2.000kg) [2][0][0][0] 2.000 kg ▼▼
▼▼SP2 value is 2 kg
Press [Enter] ke
y
[Enter]
S.PoInt3
6.000 kg ▼▼
▼SM1, SP3 data Set.
SM1 bright
Input number value
(Example: 3.000kg) [3][0][0][0] 3.000 kg ▼▼
▼
▼SP3 value is 3 kg
Press [Enter] ke
y
[Enter]
S.PoInt4
6.000 kg ▼▼
▼SM1, SP4 data Set.
SM1 bright
Input number value
(Example: 4.000kg) [4][0][0][0] 4.000 kg ▼▼
▼
▼SP4 value is 4 kg
Press [Enter] key [Enter] S.PoInt1
6.000 kg ▼▼
▼SM2, SP1 data Set.
SM2 bright
Repeat above
operation :
:
SM2~SM5 data
Press [Tare] key [Tare] 0.000 kg ▼▼Weighing mode
Note: The value of each set point should be assure SP1 less then SP2, SP2 less then SP3,
SP3 less then SP4 and SP4 less then full capacity.
All manuals and user guides at all-guides.com

DI-600 Operation Manual
Page No. 9
2.11.2. Set Point Memory Recall
INDICATION FLAG : ( ▼EXPRESS BRIGHT, SPARKLING )
(1) Zero (2) Net (3) STA (4) Count (5) Check (6) MEM (7) OS1(8) OS2 (9) OS3 (10) OS4
(11) Hold (12) ALM
Indicators
Operation Key Weight 12345678910 11 12 Remarks
Weighing mode 0.000 kg ▼▼
▼
Press [ S ] [ S ] SEL. S. 1 ▼▼
Input number of
SM (1~5) (Ex: 2) [ 2 ] SEL. S. 2 ▼▼Select activity SM2
Press [Enter] key [Enter] 0.000 kg ▼▼
▼Weighting mode,
Weight is stabled
Note: The numeric keys 1~5 are available only for this operation.
2.11.3. Set-Point Check and Alarm Mode Select
There is Filling or Check Weighing methods for application of Set-Point Alarm Function.
zFilling Application
Operator can set the certain weight point to judge the filled weight reached or over target
range. The target range can be determined between 2 set-point (set-point 2 and set-point
3), the continuous and fast alarm will alert when weight is reached target weighing range.
And the range of Set-point 1 to 2 and Set-point 3 to 4 can be programmed as fine
adjustment range.
(Min.) (Max.)
Near Min. Target Over Max.
Zero Set-point 1 Set-point 2 Set-point 3 Set-point 4 Capacity
Note: means slow alarm and means fast alarm.
Indicators
Operation Key Weight 12345678910 11 12 Remarks
Weighing mode 0.000 kg ▼▼▼
Press [ CH ] [ CH ] ALA. FIL ▼▼
Press [Enter] [Enter] 0.000 kg ▼▼▼
Entry weighting
mode, filling check
alarm on.
Note: Please enable the set-point alarm via setting of SPEC 06 bit 1.
zWeight Check Application
Operator can set the allowable error weight range between 2 set-points (set-point 2 and
set-point 3), and the range of Set-point 1 to 2 and Set-point 3 to 4 can be programmed as
out of range.
(Min.) (Max.)
Out Allowable Out
Zero Set-point 1 Set-point 2 Set-point 3 Set-point 4 Capacity
Note: means slow alarm and means fast alarm.
All manuals and user guides at all-guides.com

DI-600 Operation Manual
Page No. 10
Indicators
Operation Key Weight 12345678910 11 12 Remarks
W
eighing mode 0.000 kg ▼▼▼
Press [ CH ] [ CH ] ALA. FIL ▼▼
Press [ CH ] [ CH ] ALA. CH ▼▼
Press [enter] ke
y
[Enter] 0.000 kg ▼▼▼▼
Entry weighting
mode, weight
check alarm on
Note: Please enable the set-point alarm via setting of SPEC 06 bit 1.
zAlarm Sound Off
Indicators
Operation Key Weight 12345678910 11 12 Remarks
W
eighing mode 0.000 kg ▼▼▼
Press [ CH ] [ CH ] ALA. FIL ▼▼
Press [ CH ] [ CH ] ALA. CH ▼▼
Press [ CH ] [ CH ] ALA.OFF ▼▼
A
larm off
Press [Enter] ke
y
[Enter] 0.000 kg ▼▼▼Back weighing mode
2.11.4. Weight Check Bar of Set-Point
The check bar can be separated as three phases of display range.
First phase corresponds to the range between set-point 1 and 2.
Second phase corresponds to the range between set-point 2 and 3.
Third phase equals to the range between set-point 3 and 4.
The first and third range has 5 grades of
indicators for each, and one grade of indicator
equals to 20% of weight range between
set-point 1 & 2 or 3 & 4.
Ex: The system once increment is 5 g.
Set-point data:
Set-point 1 = 1.000kg, Set-point 2 = 2.000kg
Set-point 3 = 4.000kg, Set-point 4 = 5.000kg
Display Sample Weight
Fig 1 1.000 ~ 1.195 kg
Fig 2 1.800 ~ 1.995 kg
Fig 3 2,000 ~ 3,995 kg
Fig 4. 4.800 ~ 4.395 kg
Fig 5 Over 5.000kg
LOW OK CHECK
HI GH
LOW OK CHECK
HI GH
LOW OK CHECK
HI GH
LOW OK CHECK
HI GH
LOW OK CHECK
HI GH
LOW OK CHECK
HI GH
Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
SP1 SP2 SP3 SP4
All manuals and user guides at all-guides.com

DI-600 Operation Manual
Page No. 11
2.12. Counting Mode
DI-600 has counting function. It can set the sample quantity.
The default sample quantity is 10, or you can set the certain quantity as you need.
2.12.1. Key Entry Quantity
INDICATION FLAG : ( ▼EXPRESS BRIGHT, SPARKLING )
(1) Zero (2) Net (3) STA (4) Count (5) Check (6) MEM (7) OS1(8) OS2 (9) OS3 (10) OS4
(11) Hold (12) ALM
Indicators
Operation Key Weight 12345678910 11 12 Remarks
W
eighing mode 0.000
kg ▼▼▼
Load10 pcs sample 0.025 kg
▼▼Counting mode
Press [ Count ] [ Count ] 10 PCS
▼▼▼
Remove all 0 PCS ▼▼▼▼
Put one package 100 PCS
▼▼▼
Remove all 0 PCS ▼▼▼▼
Press [ C ] ke
y
[ C ] 0.000 kg ▼▼▼Weighing mode.
2.12.2. Sample Quantity Setting
INDICATION FLAG : ( ▼EXPRESS BRIGHT, SPARKLING )
(1) Zero (2) Net (3) STA (4) Count (5) Check (6) MEM (7) OS1(8) OS2 (9) OS3 (10) OS4
(11) Hold (12) ALM
Indicators
Operation Key Weight 12345678910 11 12 Remarks
Weighing mode 0.000
kg ▼▼▼
Press [ Count ] [Count] 10 PCS ▼▼ ▼
▼
Key in quantity [8][5][0] 850 PCS ▼▼ ▼
▼
Press [Enter] key [Enter] 0.000 kg ▼▼▼Weighing mode
2.12.3. Sample Quantity Modification and Print Receipt
INDICATION FLAG : ( ▼EXPRESS BRIGHT, SPARKLING )
(1) Zero (2) Net (3) STA (4) Count (5) Check (6) MEM (7) OS1(8) OS2 (9) OS3 (10) OS4
(11) Hold (12) ALM
Indicators
Operation Key Weight 12345678910 11 12 Remarks
Weighing mode 0.000
kg ▼▼▼
Load10 pieces 0.025 kg
▼▼Into counting mode
Press [Count] [ Count ] 10 PCS
▼▼▼
Remove
0 PCS ▼▼▼▼
Press [ Count ] [ Count ] 10 PCS ▼▼▼▼ ▼Weight is “0”
Key in quantity [1][0][0][0] 1000 PCS ▼▼ ▼
▼EX: 1000
Press [Enter] key [Enter] 0.000 kg ▼▼▼
Load 1000 pieces 1.525 kg
▼▼Counting mode
Press [ Count ] [ Count ] 1000 PCS
▼▼▼
Put one package 2000 PCS
▼▼▼
Press [Enter] key [Enter] 2000 PCS
▼▼Print receipt
Remove all 0 PCS ▼▼▼▼
Press [ C] key [ C ] 0.000 kg ▼▼▼Weighing mode.
All manuals and user guides at all-guides.com

DI-600 Operation Manual
Page No. 12
Same of Printed Receipt:
2.13. Accumulation Operation
2.13.1. Weight Accumulation
INDICATION FLAG : ( ▼EXPRESS BRIGHT, SPARKLING )
(1) Zero (2) Net (3) STA (4) Count (5) Check (6) MEM (7) OS1(8) OS2 (9) OS3 (10) OS4
(11) Hold (12) ALM
Indicators
Operation Key Weight 12345678910 11 12 Remarks
W
eighing mode 0.000 kg ▼▼▼
Load weight on 25.500 kg
▼▼EX: 25.50kg
Press [ + ] ke
y
[ + ] Add. 1
25.500 kg
▼▼ ▼ Or auto print weight
receipt
W
ait for printing end 25.500 kg ▼▼ ▼ Auto return to
weighing mode.
Remove weight 0.000 kg ▼▼▼ ▼
Load weight on 15.500 kg
▼▼ ▼ Ex: 15.50kg
Press [ + ] key [ + ] Add. 2
41.000
kg
▼▼ ▼ Or auto print weight
receipt
W
ait for printing end 15.500 kg ▼▼ ▼ Auto return to
weighing mode.
Remove weight 0.000 kg ▼▼▼ ▼
Press [ + ] ke
y
[ + ] tot. 2
41.000
kg
▼▼▼ ▼ Display the total
weights stored
Press [ C ] ke
y
O
r
Press [ Enter ]
[ C ]
[ Enter ]
0.000 kg ▼▼
Here you can clear
or print the total
value and grand
total operation.
W
ait for printing end 0.000 kg ▼▼▼Return to weighting
mode.
Note: After printed the total value, accumulator will be clear to “0”, in meantime this total will be
added into grand total.
02 06-18 15:21
CODE: 123456
PIECES: 2000
------------------------------
All manuals and user guides at all-guides.com
all-guides.com

DI-600 Operation Manual
Page No. 13
2.13.2. Quantity Accumulation
INDICATION FLAG : ( ▼EXPRESS BRIGHT, SPARKLING )
(1) Zero (2) Net (3) STA (4) Count (5) Check (6) MEM (7) OS1(8) OS2 (9) OS3 (10) OS4
(11) Hold (12) ALM
Indicators
Operation Key Weight 12345678910 11 12 Remarks
Weighing mode 0.000 kg ▼▼▼
Load 10 pieces 0.025 kg
▼▼Ex: 10 pcs
Press [ Count ] [ Count ] 10 PCS
▼▼
Remove all 0 PCS ▼▼▼
Load one bag 200 PCS
▼▼Ex: 200 pieces
Press [ + ] [ + ] Add. 1
200 PCS
▼▼ ▼ With printing the
accumulated data
Remove all 0 PCS ▼▼▼ ▼
Put one bag 300 PCS
▼▼Ex: 300 pieces
Press [ + ] [ + ] Add. 2
500 PCS
▼▼ ▼ With printing the
accumulate data
Remove all 0 PCS ▼▼▼ ▼
Press [ + ] key
again [ + ] tot. 2
500 PCS ▼▼▼ ▼ Display the total
PCS.
Press [ C ] key
or
Press [ Enter ]
[ C ]
[ Enter ]
0
PCS ▼▼Hear you can clear
or print the total
Wait for printing
end 0 PCS ▼▼▼Return to weighing
mode.
Note: After printed the total value, accumulator will be clear to “0”, in meantime this total will be
added into grand total.
Sample of Printed Receipt:
02 06-18 15:21
# 123456
+ 200 PCS
# 123456
+ 300 PCS
A 0002
T 500 PCS
02 06-18 15:28
# 123456
+ 25.500kg
# 123456
+ 15.500kg
A 0002
T 41.000kg
All manuals and user guides at all-guides.com

DI-600 Operation Manual
Page No. 14
2.14. Grand Total Check and Print
INDICATION FLAG : ( ▼EXPRESS BRIGHT, SPARKLING )
(1) Zero (2) Net (3) STA (4) Count (5) Check (6) MEM (7) OS1(8) OS2 (9) OS3 (10) OS4
(11) Hold (12) ALM
Indicators
Operation Key Weight 12345678910 11 12 Remarks
Weighing mode 0.000 kg ▼▼
Press [ Mode ] [ Mode ] P.tOtAL
41.000 kg ▼▼
Ex: 41.000kg,
Auto print grand
total weight.
Press [ Enter ] [ Enter ] C.tOtAL
500 PCS ▼▼
Ex: 500PCS,
Auto print grand
total quantity.
Press [ Enter ] [ Enter ]
D
02.06.1
8
▼▼
Press [ Tare ] key [ Tare ] 0 kg ▼▼▼Wighting mode.
Note: After printed the grand total value, memory will be clear to “0”.
Sample Receipt of Grand total Printed. (English)
2.15. Printed Ticket Sample
02 06-18 15:28
GRANDTOTAL
GT 41.000kg
---------------------------------
-
02 06-18 15:28
GRANDTOTAL
GT 500PCS
---------------------------------
-
02 06-18 10:16
CODE: 123456
GROSS: 1.000kg
NET: 0.520kg
TARE: 0.480kg
--------------------------
DI-600 PRINT
All manuals and user guides at all-guides.com

DI-600 Operation Manual
3. Error Message
3.1. Error Message List & Solution
DI-600 will display error message if improper operation is performed or system defect.
No. Display Contents Solution
01 OF
Over Flow, weight is over full
capacity. Remove some weight form platform.
02 LO
Lower weight, weight value is
lower then limit of display
mask weight.
Add some weight or restart the
indicator
03 nOt Ad
A/D error Check the A/D board and load cell are
defective or not.
04 zErO Er
Zero Point error, not at zero
point or over start range Remove weight on platter or restart
the scale, otherwise calibrate it again.
05 Add. OF
Accumulated data over flow Clear the total data and operate again.
06 GrA. OF
Grand Total data over flow Clear the grand total.
If the problems still can not be resolved according to above information, please contact to our
local dealer or Technical Service Dept. of Shanghai Teraoka via the information which described
on manual cover.
Page No. 15
All manuals and user guides at all-guides.com

DI-600 Service Manual
4. Interface & Protocol
4.1. Load Cell Connecter
zDDK-14PIN connector.
zAllows to parallel connected 8 load cells with 350 Ohm impedance for each.
zRegulated 6 wire connection with power feedback signal.
zExciting voltage: DC 12V, 280 mA.
zPin connection:
Pin No. Signal Wire Color Pin No. Signal Wire Color
1 RS+ Orange 8 F.GND
Wire Layer
2 RS- Blue 9 NC
3 V+ Red 10 NC
4 V - White 11 NC
5 GND Black 12 NC
6 IN+ Green 13 NC
7 IN - Yellow 14 NC
4.2. RS-232C Port
The Baud Rate of RS-232C setting is selectable in SPEC 04, and the other parameters are fixed
as following:
(1)Data Length : 8 bit
(2)Stop Bit: : 1 bit
(3)Parity Bit : No
4.2.1. RS-232 Cable Connection
DI-600 (D-Din 8Pin) PC (D-SUB 9 Pins)
Pin No. Signal Name Pin No Signal Name
1 NC 1 NC
2 GND 2 RXD
3 NC 3 TXD
4 RXD 4 DTR
5 TXD 5 GND
6 DTR 6 DSR
7 NC 7 RTS
8 NC 8 CTS
9 SHIELD
9NC
Page No. 23