SETTING -UPTHEDETECTOR
TIMEADJUSTMENT:Switch1&2ofDIP-5Use forSetting “TIME”-providesN.O.relay.(Fouroptions).
Position Left -“OFF”.Position Right-“ON”.
LEDCONTROL:Switch3ofDIP-5,Use forSetting “LED”-LEDEnable/Disable
Position On-LEDENABLE-The REDLEDwill activatewhen the detectorisinalarmcondition.
Position Off -LEDDISABLE-The LEDisdisabled.
NOTE:the stateofthe switch“LED”doesnotaffectthe operation ofthe relay.When an intrusion isdetected,the LEDwill activateand the alarm
relaywill switchintoalarmcondition for2sec.
PIRSENSITIVITYADJUSTMENT:Switch4ofDIP-5.Use forSetting “PULSE”-providessensitivitycontrolofthe PIRaccording tothe
environment.
Position Left “OFF”-LowsensitivityForharshenvironments.Position Right“ON”-High sensitivityForstableenvironments.
PETIMMUNITYSETTING:Switch5ofDIP-5.Use forSettings“PET”15kg-25kg
Position Right“ON”-Immunitytoan animalup to15 kg.Position Left “OFF”-Immunitytoan animalup to25 kg
POTENTIOMETER“PIR”-adjustmentaccording toprotected area range.Use“PIR”toadjustthe detection range between 68%and 100%
(factorysetto84%).Rotatethe potentiometerclockwisetoincreaserange,counter-clockwisetodecreaserange.
AUDIOVOLUME:Usethe potentiometer“VOL.”toadjustthe audiovolume.Rotatethe potentiometerclockwisetoincreasevolume.Rotate
the potentiometercounter-clockwisetodecreasevolume.
TEST PROCEDURE:
Waitforone minutewarmup timeafterapplying 12 Vdcpower.Conducttesting withthe protected area cleared ofall people.
Walktest1.Removefrontcover.SetLEDtoONposition.2.Reassemblethe frontcover.3.Startwalking slowlyacross the detection zone.
4.Observethatthe red LEDlightswhenevermotion isdetected.5.Allow5sec.between eachtestforthe detectortostabilize.6.Afterthe walk
testiscompleted,you can setthe LEDtoOFF position.
NOTE:Walktestsshouldbe conducted,atleastonceayear,toconfirmproperoperation and coverage of
12TIMERELAYCLOSE/OPEN
ONON2SEC
ONOFF 15 SEC
OFF ON60 SEC
OFF OFF 240 SEC*TheN.C.Relay opensfor1.8-2sec.whenanalarmoccurs.
TECHNICALSPECIFICATION
Detection Method:Quad (four) elementPIR
PowerInput: 8.2to16 Vdc
CurrentDrawMono:115 mAColour:150 mA
Temp.
Compensation:YES
AlarmPeriod:2+/-1sec
AlarmOutput: N.C28Vdc0.1Awith10 Ohm
seriesprotection resistors
TamperSwitch:N.C28Vdc0.1Awith10 Ohm
seriesprotection resistor-open
when coverisremoved
WarmUpPeriod:1min
LEDIndicator:Red LEDisONduring alarm
Dimensions:116mm x62.5mm x40mm
(4.56”x2.46”x1.57”)
Weight: 135 gr.
CAMERA TECHNICALSPECIFICATION
CameraType:B&W:CCIRorEIACOLOR:PALorNTSC
PictureElements:290K(PAL;CCIR)250K(NTSC;EIA)
Resolution:420 TVlines(PAL;NTSC),380 TVlines(CCIR;EIA)
Sensitivity:0.5Lux-F2.0(NTSC;PAL),0.5Lux-F1.2(EIA;CCIR)
S/NRatio:Betterthen 48 dB
Electronic
ShutterTime:1/60 -1/100,000 sec(NTSC;EIA)
1/50 -1/100,000 sec(PAL;CCIR)
VideoOutput: 1Vp-p75W
LIMITEDWARRANTY:DigitalSecurityControlsLtd,warrantsthatforaperiod of12 monthsfromthe dateofpurchase,the productshall be free ofdefectsinmaterialsandworkmanshipundernormaluseand thatinfulfillmentofany
breachofsuchwarranty.DigitalSecurityControlsLtdshall,atitsoption,repairorreplacethe defectiveequipmentupon returnsofthe equipmenttoitsrepairdepot. Thiswarrantyappliesonlytodefectsinpartsand workmanshipandnotto
damage incurred inshippingorhandling,ordamage due tocausesbeyond the controlofDigitalSecurityControlsLtd,suchaslightning,excessivevoltage mechanicalshock,waterdamage,ordamage arising outofabuse,alteration or
improperapplication oftheequipment.
Theforegoingwarrantyshall applyonlytothe originalbuyer,and isand shall be inlieu ofanyand all otherwarranties,whetherexpressed orimplied and ofallotherobligationsorliabilitiesonthepartofDigitalSecurityControlsLtd.Digital
SecurityControlsLtdneitherassumesresponsibilityfor,norauthorizesanyotherperson purporting toacton itsbehalftomodifyortochange thiswarranty,nortoassumeforitanyotherwarrantyorliabilityconcerning thisproduct.
InnoeventshallDigitalSecurityControlsLtdbe liableforanydirect,indirectorconsequentialdamages,lossofanticipatedprofits,lossoftimeoranyotherlossesincurredbythebuyerinconnection withthepurchase,installation oroperation
orfailureofthisproduct.
Motion detectorscan onlydetectmotion withinthe designated areasasShownintheirrespectiveinstallationinstructions.Theycannotdiscriminatebetweenintrudersand intended occupants.Motion detectorsdonotprovidevolumetricarea
protection.Theyhavemultiplebeamsofdetection and motion can onlybe detectedinunobstructedareascovered bythesebeams.Theycannotdetectmotion whichoccursbehind walls,ceilings,floor,closed doors,glasspartitions,glass
doorsorwindows.Any
type oftampering whetherintentionalorunintentionalsuchasmasking ,painting,orspraying ofanymaterialon the lenses,mirrors,windowsoranyotherpartofthe detection systemwill impairitsproperoperation.
Passiveinfraredmotion detectorsoperatebysensingchangesintemperature.Howevertheireffectivenesscan be reduced whentheambienttemperaturerisesnearorabovebodytemperatureorifthereareintentionalorunintentionalsources
ofheatinornearthedetectionarea.Someoftheseheatsourcescouldbeheaters,radiators,stoves,barbeques,fireplaces,sunlight, steamvents,lighting and soon.
WARNING:DigitalSecurityControlsLtd,recommendsthattheentiresystembecompletelytestedon aregularbasis.However,despitefrequenttesting,anddueto,butnotlimitedto,criminaltampering orelectricaldisruption,
itispossibleforthisproducttofail toperformasexpected.
Importantinformation:Changes ormodificationsnotexpresslyapprovedbyDigitalSecurityControlsLtdcouldvoidtheuser'sauthoritytooperatethisequipment.
2005 DigitalSecurityControlsLtd
Toronto,Canada
www.dsc.com
FIG 7-PCBLayout
FIG5-BracketInstallation
Wall Mount
BracketCeiling Mount
Bracket
FIG6-Bracketoptions
1 2
1
3
4
BLOCK CONNECTOR
PYROSENSOR