Easy@Home HTJ-2060B User manual

ULTRASONIC COOL MIST
HUMIDIFIER
HUMIDIFICADOR ULTRASÓNICO
DE NIEBLA FRÍA
English……3
Español…..17
User Manual
Manual
del usuario

Contents
Parts list.....................................................................3
Contents ...............................................................3
Main parts disassembled ......................................4
General information..................................................5
Safety instructions ................................................7
User instructions .......................................................9
Before each use ....................................................9
How to operate...................................................10
Setting the correct humidity output ...................11
Using essential oils..............................................11
Helpful hints............................................................12
Troubleshooting......................................................13
Cleaning and maintenance......................................14
Other useful information ........................................15
Technical specifications ......................................15
Storing ................................................................15

Parts list
3
Main parts
1. Mist Lid
2. Water Tank
3. Humidifier Base
Contents of packaging
Humidifier Base
Water Tank
Mist Lid
2 Extra Aroma Pads (located in bag with manual)
Instruction Manual
3
2
1

Main parts disassembled
4
Main parts disassembled
Fig. 1 –Water Tank Mist Lid
1. Vapor Output
Fig. 2 –Top of Water Tank
2. Vapor Outlet Channel
3. Water Tank Handle
Fig. 3 –Bottom of Water Tank
4. Water Tank Valve
5. Water Tank Cap
6. Vapor Outlet Channel
Fig. 4 –Top of Base
7. Nebulizer
8. Valve Opener
9. Water Level Sensor Float
10. Fan Vent
11. Vaporization Chamber
Fig. 5 –Front of Base
12. Control Knob
13. Power Indicator Light
14. LED Night Light
15. LED On/Off Button
16. Aroma Tray with Aroma Pad
1
3
2
6
4
5
11
10
9
8
7
16
15
12
13
14

General information
5
General information
When using an electrical appliance, basic safety precautions should also be
observed, including the following. PLEASE READ AND SAVE ALL INSTRUCTIONS
BEFORE USING THE ULTRASONIC COOL MIST HUMIDIFIER.
DO NOT carry water tank by handle when it is filled with water. It is advisable
to carry filled water tank with two hands.
DO NOT operate outdoors. This humidifier is intended for indoor use only.
Always have water in the tank when operating the unit.
Use only clean, cool tap water to fill the tank. Filtered or distilled water is
recommended to avoid white dust if tap water is too hard. DO NOT use hot
water.
DO NOT pour water in any openings other than the water tank.
Be sure that the water tank cap is firmly tightened. Always have the mist
direction nozzle and the mist chamber in place while the unit is operating.
Rotate the mist direction nozzle so it aims away from children, walls,
furniture, and electrical appliances.
Use only a 110-120VAC outlet. ALWAYS plug and unplug humidifier with dry
hands.
Never operate the humidifier with a damaged power supply cord or plug.
Always place the humidifier on a smooth, flat, lint free, non-metallic,
waterproof, level surface, and away from direct sunlight. Keep the power
supply cord away from heated surfaces and areas where it could be walked on
or tripped over. DO NOT let the cord hang over the edge of a table or counter.
Unplug the humidifier when not in use and whenever you clean or move the
humidifier.
DO NOT add medication of any type into the nozzle, base or water tank. Do
not cover any openings on the humidifier or insert objects into any openings.
The humidifier should not be left unattended in a closed room as the air could
become saturated and leave condensation on walls or furniture. Leave room
door partly open.
The humidifier requires daily and weekly cleaning to operate appropriately.
Refer to cleaning instructions.
When cleaning the inside of the unit keep water away from the air outlet / fan
vent. The exterior may be wiped with a damp cloth, except the electrical
controls, only when the unit is off and unplugged.

General information
6
NEVER use detergents, gasoline, glass cleaner, furniture polish, paint thinner
or other household solvents to clean any part of the humidifier. Always use a
few drops of bleach with water to clean humidifier. Detergent film dissolved
in the water supply can interfere with the output of the unit.
Do not tilt or tip the unit or attempt to empty or fill it while it is in operation.
THIS HUMIDIFIER IS NOT A TOY! Do not let your child play with this appliance.
Serious injury and electrocution might be possible. This appliance has to be
operated by an adult only. Children should be supervised to ensure that they do
not play with the humidifier.
READ AND SAVE ALL INSTRUCTIONS!

Safety instructions
7
Safety instructions
WARNING: Read and understand all instructions. Failure to follow all instructions
listed below may result in electric shock, fire or serious personal injury. The
warnings, cautions, and instruction discussed in this instruction manual cannot
cover all possible conditions and situations that may occur. It must be understood
by the operator that common sense and caution are a factor which cannot be built
into this product, but must be supplied by the operator.
CAUTION: A short power supply cord is provided to reduce the risk of personal
injury resulting from becoming entangled in or tripping over a longer cord.
Extension cords are available from local hardware stores and may be used if care is
exercised in their use. If an extension cord is required, special care and caution is
necessary. Also the cord must be: (1) marked with an electrical rating of 125V, and
at least 13 A., 1625 W., and (2) the cord must be arranged so that it will not drape
over the countertop or tabletop where it can be pulled on by children or tripped
over accidentally.
Polarized plug
This humidifier has a polarized plug (one blade is wider than the other). As a safety
feature to reduce the risk of electrical shock, this plug is intended to fit in a
polarized outlet only one way. If the plug does not fit fully in the outlet, reverse
the plug. If it still does not fit, contact a qualified electrician. Do not attempt to
defeat this safety feature.
Electric power
If the electric circuit is overloaded with other appliances, your humidifier may not
operate properly. The humidifier should be operated on a separate electrical
circuit from other operating appliances.
Safety warning
Although your Ultrasonic Humidifier is easy to operate, for your safety, the
warnings below must be followed:
1. Do not place the Ultrasonic Humidifier near a heat source.
2. Never leave the Ultrasonic Humidifier unattended while connected to the
electrical outlet.
3. Use the Ultrasonic Humidifier on a stable surface away from water.

Safety instructions
8
4. Do not unplug the Ultrasonic Humidifier by pulling on the power supply cord.
5. The Ultrasonic Humidifier must be unplugged:
A. Before any cleaning or maintenance.
B. Before either filling or emptying.
C. After use.
D. If it appears to be faulty.
Please note: when the tank is empty the fan and nebulizer will stop so no damage
or melting will occur.
THIS PRODUCT IS INTENDED FOR HOUSEHOLD USE ONLY.
SAVE THESE INSTRUCTIONS
This power indicator light is
green when the power is on and
there is water in the tank. This
light will turn red if the unit runs
out of water.

User instructions
9
User instructions
Before each use
CHECK HUMIDIFIER PLACEMENT –Place the Humidifier on a non-metallic, lint
free, waterproof, level surface for best performance. This is to help disperse the
mist in the air and prevent it from being knocked or tipped over.
CAUTION:
DO NOT operate the humidifier without water in the water tank.
DO NOT plug in the power supply cord with wet hands; electric shock could
happen.
Be sure the humidifier is turned OFF and the humidifier is unplugged from the
electrical outlet.
Select a location for your humidifier on a flat surface approximately 4 inches
away from a wall.
DO NOT place the humidifier on a finished floor or near furniture which can be
damaged by moisture or water. Place on a water resistant surface.
DO NOT place humidifier on top of a towel, or a carpeted surface. This may
cause the humidifier to overheat.
DO NOT place humidifier on a wood surface.
DO NOT USE ANY ABRASIVE MATERIAL TO CLEAN THE SURFACE
DO NOT IMMERSE THE HUMIDIFIER BASE INTO WATER AT ANY TIME

User instructions
10
How to operate
1. Lift water tank off of base holding bottom of tank with both hands.
2. NOTE: DO NOT hold water tank by handle when empty or full.
3. Turn tank upside down and unscrew water tank cap by turning it counterclockwise.
4. Fill water tank with cold water. Do not fill all the way to the rim.
5. NOTE: If you have hard water, it is recommended to use filtered or distilled water.
While using the humidifier, if you see a film of white dust, it is because of hard water.
6. DO NOT add any medication or other additives into the water tank itself. For use of
essential oils, see page 11.
7. Screw water tank cap back onto tank by turning clockwise.
8. Place tank onto the base. Make sure it is laying flush into the base. There should not
be a space between the tank and base.
9. Place mist lid on top of water tank and turn mist lid to face desired direction of the
mist.
10. NOTE: DO NOT move humidifier while water tank is on base. Water may leak into the
base causing a malfunction.
11. Plug the power cord into an electrical outlet. DO NOT use an extension cord.
12. Turn power on by turning the knob clockwise (to the right). You will hear a minor
clicking noise when turning unit on and off. The green power indicator light will turn
on.
13. In a few moments, the mist will start coming through the mist lid. Use the control
knob to adjust the intensity of the mist output. Turning the knob clockwise will
increase the moisture output, turning the knob counterclockwise will reduce the
moisture output.
14. Note: When at maximum level it is normal to hear a faint dripping sound.
15. Turn on the blue LED light by pressing the ‘LED On/Off’ button in. To turn it off, press
the button again.
16. When the humidifier runs out of water the power light will turn red, and the mist
output will stop. This is a safety feature to prevent the humidifier from possibly
overheating and damaging the nebulizer. This safety feature uses a water level sensor
to stop the nebulizer once the water level sinks below the required level in the water
basin.
17. Turn the humidifier off and unplug before removing and refilling the water tank.

User instructions
11
Incorrect
Correct
Setting the correct humidity output
Adjust the mist control so that the mist rises up and gets absorbed by the room air. Do
not turn on too high an output as the mist cannot be absorbed by the air and
accumulates on the surface around the humidifier. If the humidifier is placed near a
fan or air conditioning outlet the mist may be forced down by the foreign air stream.
Change the location of the humidifier or reduce the output of the other room
conditioning appliances.
Using essential oils
Essential oils can be used on the aroma pad located in the aroma tray on the side of
the base. You can mix and match any oil scents you would like.
1. Place about 3 drops of desired scent on the aroma pad.
2. Place the pad back into the aroma tray.
3. Push the aroma tray into the base.
4. Each pad should only be used per desired scent.
5. Before attempting to reuse aroma pad with a different scent, clean the aroma pad
by lightly hand washing it in warm water and letting it thoroughly air dry.

Helpful hints
12
Helpful hints
1. It is best to keep the humidity level at about 30-50 percent of relative
humidity.
2. The comfort level of humidity will vary from room to room and with changing
room conditions.
3. In cold weather, windows and even some walls may fog or develop frost from
excessive indoor humidity. If this occurs, reduce the mist intensity setting to
avoid damage from condensed water dripping on windowsills.
4. Too much humidity in the room may allow moisture to accumulate on
surfaces where bacteria and fungi can grow. Moisture that gathers may also
damage furniture and walls, especially wallpaper.
5. To eliminate excessive humidity, especially in small rooms, leave the room
door open and adjust the mist intensity control setting.
6. Note: To avoid possible white dust due to hard water, it is recommended to
use filtered or distilled water.
7. DO NOT use hot water. Use cool tap water.
8. DO NOT add any medication or other additives to the water.
9. DO NOT pour water into Vapor Outlet Channel (Page 4, Fig. 2, Part 2).
10. Note: Do not attempt to move humidifier while water tank is placed on the
water basin. Doing so may cause leakage of water. Also do not place
humidifier on the floor. Place humidifier on an elevated surface.

Troubleshooting
13
Troubleshooting
CAUTION: DO NOT attempt to repair the motor or nebulizer yourself. If the
humidifier continues to not operate please call customer service.
Problem
Solution
The power indicator light is staying
red and not turning green:
Humidifier is working than stops:
Clean the base especially where
the water level sensor float is
If humidifier does not work at all:
Ensure it is properly plugged into a
power outlet.
Check that the control knob is in
the ON position.
If Power On indicator light does
not come on, bring to authorized
service station.
If there is a strange odor:
Clean the tank with water and
vinegar or bleach and rinse with
clean water.
Leave the tank open for some time
without the cap, in a cool place.
The power indicator light is green
but there is no mist being emitted:
Check that there is water in the
tank.
Check for possible lime deposits
on the water level sensor or the
nebulizer.
Make sure that nothing blocks the
vapor output slots.
Check that the fan vent on bottom
of humidifier is not blocked.
Empty the humidifier and rinse the
water basin with cool tap water
and allow to dry for 15 to 30 min.
White dust appears and settles
outside the humidifier:
Area tap water may have too
many minerals, change to filtered
or distilled water.

Cleaning and maintenance
14
Cleaning and maintenance
Portable humidifiers require regular cleaning in order to reduce the risk of bacterial
growth and also to remove any scale residue to maintain good operational
performance. Follow the procedures below for healthy maintenance of your
Ultrasonic Cool Mist Humidifier.
CAUTION:
Always be sure that the humidifier is unplugged and switched OFF before cleaning or
attempting to clean or store the item. NEVER PLUG OR UNPLUG HUMIDIFIER WITH
WET HANDS.
DO NOT leave water in water tank or water basin when unit is not in use as it may
result in the buildup of mineral deposits and bacteria that can inhibit the output
efficiency of the humidifier. PLEASE NOTE that if water remains in the water tank for
more than a day or two, bacterial growth is possible.
NOTE: When removing water tank, water may accumulate under vapor lid and on the
bottom of the water tank. It is recommended to have a dry cloth ready to dry wet
surfaces.
Disinfecting the water tank and water basin
1. Fill water tank with 2 tablespoons of white vinegar or bleach in a ½ gallon of
water. Let stand 20 minutes. Screw on water tank cap and shake vigorously with
two hands every few minutes, drain and rinse with clean water until the vinegar
or bleach smell is gone. Dry with a clean cloth or paper towel.
2. Fill the base with water and add 2 tablespoons of white vinegar or bleach to the
water and let it soak for 20 minutes. Drain the base and rinse with cool water.
Dry with a soft cloth. DO NOT IMMERSE WATER BASIN IN WATER. An electric
shock may result or the humidifier may be damaged.
3. Wipe all exterior surfaces of the base with a damp soft cloth.
4. It is normal for water to be in the water basin. However water must not get inside
the central body. If this should happen, take the humidifier to an authorized
service center before using it again.
NOTE: It is recommended to clean humidifier with the water and white vinegar
solution as stated above after using the humidifier about once a week or if cleaning
seems necessary.
IMPORTANT: Failure to keep this humidifier clean from mineral deposits normally
contained in any water supply will affect the efficiency of the operation. Customer
failure to follow these instructions may void the warranty.

Other useful information
15
Other useful information
Technical specifications
Model Number HTJ-2060B
Rating Voltage 120V –60Hz
Rated Wattage 25W
Storing
Allow the humidifier to dry completely before storing. Store the humidifier in a
dry location. Do not place any heavy items on top of humidifier during storage as
this may result in possible damage of the appliance. Always check the plug before
use to assure metal items have not become attached.
Save the box for off-season storage.
Make sure the tank, water basin and water tank cap are dried thoroughly
before storing.
If water is left in the unit during storage, it may evaporate completely and
leave deposits that can prevent the unit from operating properly.
Leave the water tank cap loose to prevent the water cap and gasket from
sticking together. This will prolong the life of the gasket.
Service center
If you have any questions in regards to the operation of this appliance please
contact our service center at:
Tel: 1-888-367-7373
Business Hours: Mon-Fri 10:00am –5:00pm EST
Email: help@myproduct.care
Environmental protection
If the appliance should no longer work at all, please make sure that it is disposed
of in an environmentally friendly way.

Lista de componentes
16
Contenido
Componentes principales....................................17
Contenido .......................................................17
Componentes principales desmontados .........18
Información general............................................19
Instrucciones de seguridad .............................21
Modo de empleo.................................................23
Antes de cada uso...........................................23
Para el funcionamiento...................................24
Configure la salida de humedad correcta........26
Uso de aceites esenciales................................26
Consejos útiles ....................................................27
Detección y solución de problemas ....................28
Limpieza y mantenimiento..................................29
Información adicional de utilidad .......................30
Especificaciones técnicas ................................30
Almacenamiento.............................................30

Lista de componentes
17
Componentes principales
1. Tapa de salida de la niebla
2. Tanque de agua
3. Base del humidificador
Contenido del empaque
Base del humidificador
Tanque de agua
Tapa de salida de la niebla
2 almohadillas aromáticas adicionales (se encuentran en la bolsa con el
manual)
Manual de instrucciones
3
2
1

Componentes principales desmontados
18
Componentes principales desmontados
Fig. 1 –Tapa del tanque de agua para
hacer la niebla
1. Salida de la niebla
Fig. 2 –Parte superior del tanque de agua
2. Canal de salida de la niebla
3. Manija del tanque de agua
Fig. 3 –Parte inferior del tanque de agua
4. Válvula del tanque de agua
5. Tapa del tanque de agua
6. Canal de salida de la niebla
Fig. 4 –Parte superior de la base
7. Nebulizador
8. Abertura de válvula
9. Flotador de sensor de nivel de agua
10. Orificio de ventilación del ventilador
11. Cámara de vaporización
Fig. 5 –Frente de la base
12. Perilla de control
13. Luz indicadora de alimentación
14. Luz nocturna a LED
15. Botón de encender/apagar LED
16. Bandeja de aroma con almohadilla
aromática
1
3
2
6
4
5
11
10
9
8
7
16
15
12
13
14

Información general
19
Información general
Al usar un aparato eléctrico, siempre deben seguirse medidas básicas de
seguridad, incluyendo las siguientes. POR FAVOR LEA Y CONSERVE TODAS LAS
INSTRUCCIONES ANTES DE USAR EL HUMIDIFICADOR ULTRASÓNICO DE NIEBLA
FRÍA.
NO transporte el tanque de agua usando la manija cuando está lleno de agua.
Se recomienda transportar el tanque de agua lleno con las dos manos.
NO lo ponga en funcionamiento en el exterior. Este humidificador está
destinado únicamente para uso en interiores. Siempre debe haber agua en el
tanque cuando la unidad esté en funcionamiento.
Utilice solamente agua del grifo limpia y fría para llenar el tanque. Se
recomienda usar agua filtrada o destilada para evitar el sarro si el agua del
grifo es demasiado dura. NO utilice agua caliente.
NO vierta agua en ninguna de las aberturas que no sean las del tanque de
agua.
Compruebe que la tapa del tanque de agua esté bien cerrada. Siempre tenga
colocadas la boquilla de dirección de la niebla y la cámara de la niebla cuando
la unidad esté en funcionamiento. Gire la boquilla de dirección de la niebla
para que no apunte a niños, paredes, muebles y aparatos eléctricos.
Utilice únicamente un tomacorriente de 110-120 VCA. SIEMPRE conecte y
desconecte el humidificador con las manos secas.
Nunca encienda un humidificador si el cable de alimentación o enchufe están
dañados.
Siempre coloque el humidificador sobre una superficie regular, plana, sin
pelusas, no metálica, impermeable y nivelada y fuera del alcance de la luz
directa del sol. Mantenga el cable de alimentación alejado de superficies
calientes y de áreas donde pudiera volcarse o provocar tropiezos. NO deje que
el cable cuelgue por el borde de una mesa o mesada.
Desconecte el humidificador cuando no esté en uso y siempre que necesite
limpiarlo o moverlo.
NO agregue medicación de ningún tipo en la boquilla, base o tanque de agua.
No cubra las aberturas del humidificador ni introduzca objetos en ninguna de
sus aberturas.
No debe dejar el humidificador sin atención en una habitación cerrada, ya que
el aire podría saturarse, dejando condensación en paredes y muebles. Deje la
puerta de la habitación parcialmente abierta.

Información general
20
El humidificador requiere limpieza diaria y semanal para que funcione
correctamente. Consulte las instrucciones de limpieza.
Cuando limpie el interior de la unidad, mantenga el agua alejada de la salida
de aire / orificio de ventilación del ventilador. Puede limpiar el exterior con un
trapo húmedo, con excepción de los controles eléctricos, solamente cuando la
unidad esté apagada y desconectada.
NUNCA utilice detergentes, gasolina, limpiavidrios, lustramuebles, diluyente
de pintura u otros solventes domésticos para limpiar cualquier parte del
humidificador. Siempre use unas pocas gotas de blanqueador con agua para
limpiar el humidificador. Las películas de detergente disueltas en el suministro
de agua pueden interferir con la salida de la unidad.
No incline ni vuelque la unidad; tampoco intente vaciarla o llenarla mientras
está en uso.
¡EL HUMIDIFICADOR NO ES UN JUGUETE! No permita que su hijo juegue con este
aparato. Podría sufrir lesiones graves o electrocución. Solo los adultos deben
utilizar este aparato. Se debe supervisar a los niños para asegurar de que no
jueguen con el humidificador.
¡LEA Y CONSERVE TODAS LAS INSTRUCCIONES!
Table of contents
Languages:
Other Easy@Home Humidifier manuals

Easy@Home
Easy@Home 1058-2021-W User manual

Easy@Home
Easy@Home EE-5200 W User manual

Easy@Home
Easy@Home HF3102A-UL User manual

Easy@Home
Easy@Home HTJ-2060 User manual

Easy@Home
Easy@Home 1094S2022 User manual

Easy@Home
Easy@Home 49136 User manual

Easy@Home
Easy@Home EE-5201W User manual

Easy@Home
Easy@Home HTJ-2108-USBM User manual

Easy@Home
Easy@Home EE-3186A User manual

Easy@Home
Easy@Home MD19143 User manual