manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Eaton
  6. •
  7. Switch
  8. •
  9. Eaton IZM Manual

Eaton IZM Manual

Other Eaton Switch manuals

Eaton NHI-E-PKZ0 Series Manual

Eaton

Eaton NHI-E-PKZ0 Series Manual

Eaton Tripp-Lite B005-HUA2-K User manual

Eaton

Eaton Tripp-Lite B005-HUA2-K User manual

Eaton KA349WE User manual

Eaton

Eaton KA349WE User manual

Eaton RMQ-Titan M22 Series Manual

Eaton

Eaton RMQ-Titan M22 Series Manual

Eaton T6-160-6/V/SVB/HI11 Manual

Eaton

Eaton T6-160-6/V/SVB/HI11 Manual

Eaton T6-160-6/V/SVB/HI11 Manual

Eaton

Eaton T6-160-6/V/SVB/HI11 Manual

Eaton TRIPP LITE Series User manual

Eaton

Eaton TRIPP LITE Series User manual

Eaton GHG 273 User manual

Eaton

Eaton GHG 273 User manual

Eaton XNH00-1-S160 Manual

Eaton

Eaton XNH00-1-S160 Manual

Eaton EATS16N User manual

Eaton

Eaton EATS16N User manual

Eaton Magnum DS Series Manual

Eaton

Eaton Magnum DS Series Manual

Eaton CurrentWatch ECS7 Series User manual

Eaton

Eaton CurrentWatch ECS7 Series User manual

Eaton TM-1-15431 Series Manual

Eaton

Eaton TM-1-15431 Series Manual

Eaton TRIPP LITE U460-004-4A-C User manual

Eaton

Eaton TRIPP LITE U460-004-4A-C User manual

Eaton RTC-50 User manual

Eaton

Eaton RTC-50 User manual

Eaton P1-25/SE1 Series Manual

Eaton

Eaton P1-25/SE1 Series Manual

Eaton Crouse-hinds series User manual

Eaton

Eaton Crouse-hinds series User manual

Eaton RMQ-Titan M22-PV 30 Series User manual

Eaton

Eaton RMQ-Titan M22-PV 30 Series User manual

Eaton TriSync COOPER POWER MN230011EN Owner's manual

Eaton

Eaton TriSync COOPER POWER MN230011EN Owner's manual

Eaton LS4/S ZB Series Manual

Eaton

Eaton LS4/S ZB Series Manual

Eaton Bussmann Series User manual

Eaton

Eaton Bussmann Series User manual

Eaton Pow-R-Line SPX0361126 User manual

Eaton

Eaton Pow-R-Line SPX0361126 User manual

Eaton MEM Memera User manual

Eaton

Eaton MEM Memera User manual

Eaton LBS Series Installation and operating instructions

Eaton

Eaton LBS Series Installation and operating instructions

Popular Switch manuals by other brands

TRENDnet TK-401R null

TRENDnet

TRENDnet TK-401R null

TRENDnet TK-200K null

TRENDnet

TRENDnet TK-200K null

TRENDnet TE100-S8 null

TRENDnet

TRENDnet TE100-S8 null

URC Total Control MFS-8 installation manual

URC

URC Total Control MFS-8 installation manual

Azbil HPQ-D11 user manual

Azbil

Azbil HPQ-D11 user manual

Sony DFS-900M operating instructions

Sony

Sony DFS-900M operating instructions

SICK i17S operating instructions

SICK

SICK i17S operating instructions

F&F SZR-277 quick start guide

F&F

F&F SZR-277 quick start guide

Shure UAMS/BK user guide

Shure

Shure UAMS/BK user guide

Dräger X-zone Switch Off Instructions for use

Dräger

Dräger X-zone Switch Off Instructions for use

Asco Joucomatic 349 Series manual

Asco

Asco Joucomatic 349 Series manual

BT Mini Hub user guide

BT

BT Mini Hub user guide

D-Link DES-1226G manual

D-Link

D-Link DES-1226G manual

Johnson Controls FS80-C installation instructions

Johnson Controls

Johnson Controls FS80-C installation instructions

MicroNet SP1200A user manual

MicroNet

MicroNet SP1200A user manual

Ruijie RG-PF2920 Series Hardware  installation and reference guide

Ruijie

Ruijie RG-PF2920 Series Hardware installation and reference guide

Altinex DA1914SX user guide

Altinex

Altinex DA1914SX user guide

RJM MASTERMIND PBC/6X user manual

RJM

RJM MASTERMIND PBC/6X user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Effective December 2021
Instructional Leaet IL0131170EN
Auxiliary switch kit in
IZM low voltage circuit breakers
mWARNING
(1) ONLY QUALIFIED ELECTRICAL PERSONNEL SHOULD
BE PERMITTED TO WORK ON THE EQUIPMENT.
(2) ALWAYS DE-ENERGIZE PRIMARY AND
SECONDARY CIRCUITS IF A CIRCUIT BREAKER
CANNOT BE REMOVED TO A SAFE WORK LOCATION.
(3) DRAWOUT CIRCUIT BREAKERS SHOULD BE
LEVERED (RACKED) OUT TO THE DISCONNECT
POSITION.
(4) ALL CIRCUIT BREAKERS SHOULD BE SWITCHED
TO THE OFF POSITION AND MECHANISM SPRINGS
DISCHARGED.
FAILURE TO FOLLOW THESE STEPS FOR ALL
PROCEDURES DESCRIBED IN THIS INSTRUCTION
LEAFLET COULD RESULT IN DEATH, BODILY INJURY,
OR PROPERTY DAMAGE.
Section 1: General information
An auxiliary switch is an optional device providing
remote electrical indication if the circuit breaker is
open or closed. Up to three auxiliary switches can
be mounted in the circuit breaker. Each switch has
four normally open (“A”) and four normally closed
(“B”) contacts for a total of 12 available change
over contacts.
Section 2: Installation of the
auxiliary switch
To install the auxiliary switch, proceed with the
following five steps:
Step 1: Remove the front cover by unscrewing the
hex head captive bolts (four for three-pole, six for
four-pole) that join the cover to the breaker hous-
ing using a 10 mm 1/4-inch drive socket. Then hold
the charge handle down approximately 45 degrees
to pull off the cover.
Step 2: Place the appropriate label on the
front cover nameplate space located under
“Accessories.”
Figure 1. Steps 1 and 2
Step 3: Slide the lock on the switch to the
unlocked (up) position. Install the hook feet
down through openings as shown. Then slide
the auxiliary switch forward so the feet engage
the mounting plate. Slide the lock down into the
locked position.
Figure 2. Step 3
ote:N The number of auxiliary switches and shunt trips
cannot exceed four.
Label Bolt
Forward
Auxiliary Switch
Second Switch
Here
Mounting
Plate
Third Switch Here
First
Switch
Here
Hook
Feet
Lock
Eaton is a registered trademark.
All other trademarks are property of their
respective owners.
Auxiliary switch kit in
IZM low voltage circuit breakers
Eaton Industries GmbH
Hein-Moeller-Straße 7-11,
53115 Bonn,
Germany
Eaton.com
© 2021 Eaton Industries GmbH
All Rights Reserved
Printed in Germany
Publication No. IL0131170EN
Effective December 2021
Instructional Leaflet IL0131170EN
Effective December 2021
Step 4: Wire auxiliary switches per Table 1 and wire markings.
Figure 3. Step 4
ote:N Securely tie wires away from moving parts.
Table 1. Auxiliary Switch Secondary Wiring
Auxiliary Switch Position
#1 Contacts 49–60
#2 Contacts 61–72
#3 Contacts 73–84
Step 5: Reinstall front cover removed in Step 1.
Terminal 49 Terminal 84
Disclaimer of warranties and
limitation of liability
The information, recommendations, descriptions, and safety
notations in this document are based on Eaton Corporation’s
(“Eaton”) experience and judgment, and may not cover all
contingencies. If further information is required, an Eaton sales
office should be consulted.
Sale of the product shown in this literature is subject to the terms
and conditions outlined in appropriate Eaton selling policies or other
contractual agreement between Eaton and the purchaser.
THERE ARE NO UNDERSTANDINGS, AGREEMENTS,
WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING
WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE OR
MERCHANTABILITY, OTHER THAN THOSE SPECIFICALLY SET
OUT IN ANY EXISTING CONTRACT BETWEEN THE PARTIES. ANY
SUCH CONTRACT STATES THE ENTIRE OBLIGATION OF EATON.
THE CONTENTS OF THIS DOCUMENT SHALL NOT BECOME
PART OF OR MODIFY ANY CONTRACT BETWEEN THE PARTIES.
In no event will Eaton be responsible to the purchaser or user in
contract, in tort (including negligence), strict liability, or otherwise
for any special, indirect, incidental, or consequential damage or loss
whatsoever, including but not limited to damage or loss of use of
equipment, plant or power system, cost of capital, loss of power,
additional expenses in the use of existing power facilities, or claims
against the purchaser or user by its customers resulting from the
use of the information, recommendations, and descriptions
contained herein.
The information contained in this manual is subject to change