manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Elane
  6. •
  7. Scale
  8. •
  9. Elane Plus User manual

Elane Plus User manual

Other Elane Scale manuals

Elane PS 3000N User manual

Elane

Elane PS 3000N User manual

Elane PS 3000 W User manual

Elane

Elane PS 3000 W User manual

Elane Exceed UK User manual

Elane

Elane Exceed UK User manual

Elane PS 3000N Australia User manual

Elane

Elane PS 3000N Australia User manual

Elane PS2000 UK User manual

Elane

Elane PS2000 UK User manual

Elane Plus Series User manual

Elane

Elane Plus Series User manual

Elane PS 3000N Australia User manual

Elane

Elane PS 3000N Australia User manual

Elane USB70 User manual

Elane

Elane USB70 User manual

Elane USB10 User manual

Elane

Elane USB10 User manual

Elane PS110 USA User manual

Elane

Elane PS110 USA User manual

Elane Postage Austria User manual

Elane

Elane Postage Austria User manual

Elane POSTAGE UK User manual

Elane

Elane POSTAGE UK User manual

Elane Exceed W 500 User manual

Elane

Elane Exceed W 500 User manual

Popular Scale manuals by other brands

KERN MCC-M operating instructions

KERN

KERN MCC-M operating instructions

Little Balance SB MECA 8113 user manual

Little Balance

Little Balance SB MECA 8113 user manual

Fitbit Zip Aria Wi-Fi Smart Scale user manual

Fitbit Zip

Fitbit Zip Aria Wi-Fi Smart Scale user manual

KERN MPU 250K100 operating instructions

KERN

KERN MPU 250K100 operating instructions

Steinberg Systems SBS-PF-200 user manual

Steinberg Systems

Steinberg Systems SBS-PF-200 user manual

Total TP2000 user guide

Total

Total TP2000 user guide

A&D HL-200i operating instructions

A&D

A&D HL-200i operating instructions

OHAUS Courier 3000 user guide

OHAUS

OHAUS Courier 3000 user guide

Scarlett SC-KS57P97 instruction manual

Scarlett

Scarlett SC-KS57P97 instruction manual

BASETech LS-40S operating instructions

BASETech

BASETech LS-40S operating instructions

SR Instruments SR Scales SR565i-H Operating and service manual

SR Instruments

SR Instruments SR Scales SR565i-H Operating and service manual

Gallet PEP 301ART instruction manual

Gallet

Gallet PEP 301ART instruction manual

AWS ZEO-50 user manual

AWS

AWS ZEO-50 user manual

Gima Glass Body Fat Analyzer Use and maintenance book

Gima

Gima Glass Body Fat Analyzer Use and maintenance book

Seca 374 user manual

Seca

Seca 374 user manual

EDLUND BBPZ-20 quick start guide

EDLUND

EDLUND BBPZ-20 quick start guide

TEC TEC SL59 SERIES owner's manual

TEC

TEC TEC SL59 SERIES owner's manual

Alecto ACW-40 user manual

Alecto

Alecto ACW-40 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

ELECTRONIC POSTAL SCALE
With fold up platform for weighing large letters
OPERATING MANUAL
Max. 10lbs d = 0.1oz
TECHNICAL DETAILS
Operates either on a 9V Alkaline battery or 9V AC power adapter (included)
Loadcell technology
Liquid crystal display
Capacity 10lbs
Graduation 0.1oz.
Auto switch-off after 6 minutes of non-use (Battery only)
Plus
Using the scale with batteries
Using the scale with the power adapter
What is the purpose of the TARE/ZERO key?
Be sure that the scale is operated on a flat surface
Weighing an item
You require 1 new 9V Alkaline, leak proof battery.
Remove the battery compartment cover underneath the scale, and insert the
battery as indicated. Ensure that they are inserted the correct way around.
Replace the battery compartment cover.
Place the container onto the platform, and then touch the key. The display
will show
Place the item to be weighed into the container, on the weigh platform. The scale
will now show the weight of the item, excluding the weight of the container.
Connect the supplied power adapter to the input socket at the rear of the scale,
and plug it into the power supply. It is advisable to remove the battery when using
power adapter.
You can tare (set to zero) any article used as a container for small items, in the
following way.
If the scale is switched off, touch the key and wait for to be
displayed.
In order to operate correctly, the scale must be installed on a firm, flat surface.
Touch the key. A sign will appear on the display for a short
while, during such time the scale performs a self-check/zeroing routine, and then
displays on the LCD.
Your scale is now ready to weigh. After placing an item onto the platform, there is
a delay of approximately one second before the weight display appears.
ON
TARE
ON
TARE
ON
TARE
Scale calibration
Error messages
Should any of the symbols shown below appear in the LCD, they have the
following meaning:
The weight capacity of the scale has been exceeded.
In case the scale loses it’s accuracy then the re-calibration of the scale may be
needed.
Unpack scale and if the scale did come from a colder or warmer environment let it
first stay for 30 minutes to be at the same temperature as your current
environment.
Plug in Scale
Turn on and leave on for 1 minute or more
Turn Off
Press the button ABOVE the ON key (this is he CAL key) and then hold this key
and press the ON key for 1 sec. and leave the CAL button pressed for another 3-4
sec.
Then release
The scale should show the ZERO value nominal about 120
If shows ZERO or over 200 it must be adjusted at the internal potentiometer.
(To access this adjustment the scale must be opened and this should only be done
by qualified technicians)
Press the CAL button and a “1” appears
Place 1 kg for 3 kg and 5 lb scale (100 gram for 300 gram scale) [1.5 kg for 10 lb
scale]
Press CAL
Let the display settle and press CAL again a “2” on the display
Place 2 kg for 3 kg and 5lb scale (200 gram for 300 gram scale) [3 kg for 10 lb
scale]
Let the display settle and press CAL again s “3” appears on the display
Place 3 kg for 3 kg and 5 lb scale (300 gram for 300 gram scale ) [4.5 kg for 10 lb
scale]
Let the display settle and press CAL again a “E” appears on the display
Turn Scale Off.
Completed
This calibration procedure can be repeated anytime in case the scale was severely
overloaded. The load cell of this precision scale is normally protected against
overloaded applied slowly, but overload caused by dropping the scale or dropping
something heavy on the scale may require recalibration or re-adjustment of the
ZERO potentiometer in case the Zero is not in the range of 100-200
T