manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Electrolux
  6. •
  7. Air Conditioner
  8. •
  9. Electrolux EXl09HL1W User manual

Electrolux EXl09HL1W User manual

Other manuals for EXl09HL1W

2

This manual suits for next models

2

Other Electrolux Air Conditioner manuals

Electrolux EPF09V1K8 User manual

Electrolux

Electrolux EPF09V1K8 User manual

Electrolux EXl09HL1W User manual

Electrolux

Electrolux EXl09HL1W User manual

Electrolux Kelvinator KSV26HRB User manual

Electrolux

Electrolux Kelvinator KSV26HRB User manual

Electrolux FAH125N2 User manual

Electrolux

Electrolux FAH125N2 User manual

Electrolux EAS(C User manual

Electrolux

Electrolux EAS(C User manual

Electrolux KSV26HRC User manual

Electrolux

Electrolux KSV26HRC User manual

Electrolux EXM18HV1W User manual

Electrolux

Electrolux EXM18HV1W User manual

Electrolux EXP26V578HW User manual

Electrolux

Electrolux EXP26V578HW User manual

Electrolux EXI09HJIW User manual

Electrolux

Electrolux EXI09HJIW User manual

Electrolux EPE 800 User manual

Electrolux

Electrolux EPE 800 User manual

Electrolux CXl09HL1W User manual

Electrolux

Electrolux CXl09HL1W User manual

Electrolux Frigidaire FFPA0822R1 Owner's manual

Electrolux

Electrolux Frigidaire FFPA0822R1 Owner's manual

Electrolux EXP12HN1W6 User manual

Electrolux

Electrolux EXP12HN1W6 User manual

Electrolux FAH08EN1 User manual

Electrolux

Electrolux FAH08EN1 User manual

Electrolux FAX050P7A-1 Quick start guide

Electrolux

Electrolux FAX050P7A-1 Quick start guide

Electrolux FAK123N1 User manual

Electrolux

Electrolux FAK123N1 User manual

Electrolux EPV09CRA User manual

Electrolux

Electrolux EPV09CRA User manual

Electrolux EASC12F2MBKLW User manual

Electrolux

Electrolux EASC12F2MBKLW User manual

Electrolux EXI09HD1W User manual

Electrolux

Electrolux EXI09HD1W User manual

Electrolux KSV26HRC User manual

Electrolux

Electrolux KSV26HRC User manual

Electrolux EXP09CKEWI User manual

Electrolux

Electrolux EXP09CKEWI User manual

Electrolux EL-KFR26G/TN2Y-A Operating manual

Electrolux

Electrolux EL-KFR26G/TN2Y-A Operating manual

Electrolux FAK083N7 User manual

Electrolux

Electrolux FAK083N7 User manual

Electrolux EXM18HV1W User manual

Electrolux

Electrolux EXM18HV1W User manual

Popular Air Conditioner manuals by other brands

Fujitsu ASYG 09 LLCA installation manual

Fujitsu

Fujitsu ASYG 09 LLCA installation manual

York HVHC 07-12DS Installation & owner's manual

York

York HVHC 07-12DS Installation & owner's manual

Carrier Fan Coil 42B Installation, operation and maintenance manual

Carrier

Carrier Fan Coil 42B Installation, operation and maintenance manual

intensity IDUFCI60KC-3 installation manual

intensity

intensity IDUFCI60KC-3 installation manual

Frigidaire FAC064K7A2 Factory parts catalog

Frigidaire

Frigidaire FAC064K7A2 Factory parts catalog

Sanyo KS2432 instruction manual

Sanyo

Sanyo KS2432 instruction manual

LG MultiV Series installation manual

LG

LG MultiV Series installation manual

CLIMAVENETA a-CHD U-2T 606+2209 OPERATING AND INSTALLATION Manual

CLIMAVENETA

CLIMAVENETA a-CHD U-2T 606+2209 OPERATING AND INSTALLATION Manual

Midea EWK06CW5 user manual

Midea

Midea EWK06CW5 user manual

Pioneer FAB Series installation manual

Pioneer

Pioneer FAB Series installation manual

SPT WA-1511S user manual

SPT

SPT WA-1511S user manual

Mitsubishi Electric Mr.Slim MSZ-A24NA operating instructions

Mitsubishi Electric

Mitsubishi Electric Mr.Slim MSZ-A24NA operating instructions

Mitsubishi Electric PUHZ-RP50VHA4 Service manual

Mitsubishi Electric

Mitsubishi Electric PUHZ-RP50VHA4 Service manual

Panasonic CS-S18HKQ Service manual

Panasonic

Panasonic CS-S18HKQ Service manual

Panasonic CS-E15NKE3 operating instructions

Panasonic

Panasonic CS-E15NKE3 operating instructions

Gree GWH18TC-K3DNA1B/I Service manual

Gree

Gree GWH18TC-K3DNA1B/I Service manual

Friedrich ZoneAire Compact P08SA owner's manual

Friedrich

Friedrich ZoneAire Compact P08SA owner's manual

Daikin R32 Split Series installation manual

Daikin

Daikin R32 Split Series installation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

EXl09HL1W
EXl12HL1W
EXl18HL1W
......................................................... .........................................................
BG ɂɇȼȿɊɌɈɊɇȺɋɉɅɂɌɋɂɋɌȿɆȺ
EN SPLIT INVERTER HEAT PUMP
HU 26=7277È7$/$.Ë7Ï+ė6=,9$77<Ò
PL ,1:(57(52:<./,0$7<=$72563/,7
=3203Ą&,(3à$
RO 6,67(0'(&/,0$7,=$5(
&8,19(572563/,7
SK '(/(1e,19(572529e./,0$7,=$ý1e
=$5,$'(1,(67(3(/1é0ý(53$'/20
ɊɔɄɈȼɈȾɋɌȼɈɁȺɍɉɈɌɊȿȻȺ 
USER MANUAL 27
.(=(/e6,Ò7087$7Ï 
,16758.&-$2%6à8*, 
0$18$/8/87,/,=$7258/8, 
1È92'1$328äË9$1,( 
27
Table of Contents
Congratulations ...................................................................28
Safety Precautions ..............................................................29
Product´s Description ..........................................................31
Indoor Unit Display ..............................................................32
Remote Control ...................................................................32
Quick Start Guide ................................................................33
Remote Control Description ................................................34
Remote Control Display Indicators ......................................37
First Use ..............................................................................38
How to use the Remote Control ..........................................38
How to use the Indoor Unit ..................................................43
Emergency Operation ..........................................................45
Optimal Operation ...............................................................46
Cleaning and Maintenance ..................................................46
Operation Tips .....................................................................50
Troubleshooting ...................................................................51
Product List ..........................................................................52
.eeStKe UePote FontUol ZKeUe Lts sLJnal Fan UeaFK tKe
UeFeLYeUof tKe LnGooUXnLt
:Ken oSeUate tKe aLU FonGLtLoneU PaNe sXUe tKe UePote
FontUol Ls SoLntLnJto tKe sLJnal UeFeLYeUof tKe LnGooU
XnLt
:Ken tKe UePote FontUol senGs oXt a sLJnaltKe s\Pbol
ZLll blLnNfoUaboXt seFonGon tKe GLsSla\of tKe
UePote FontUol
TKe LnGooUXnLt ZLll aFNnoZleGJe tKe sLJnal ZLtKa beeS
ZKen Lt UeFeLYes tKe sLJnal fUoPtKe UePote FontUol
3lease SUess tKe bXtton of tKe UePote FontUol anG
UesenGtKe sLJnal Lf \oXGLG not KeaUa beeSfUoPtKe
LnGooUXnLt
,PSoUtant 5ePLnGeU
28
&RQJUDWXODWLRQV
 The air conditioner is not intended for use by
\RXQJFKLOGUHQRULQ¿UPHGSHUVRQVZLWKRXW
supervision.
 Young children should be supervised to ensure
that they do not play with the air conditioner.
 Contact an authorised installer for installation
of this air conditioner.
 Contact an authorised service technician for
repair or maintenance of this unit.
 If the power cord is to be replaced,
replacement work shall be performed by
authorised personnel only.
 Installation work must be performed in
accordance with the national wiring Standards
by authorised personnel only.
Congratulations and thank you for choosing a split-
W\SHDLUFRQGLWLRQHU:HDUHVXUH\RXZLOO¿QG\RXU
new air conditioner a pleasure to use.
Before you use the air conditioner, we recommend
that you read through the entire user manual, which
provides the description of the air conditioner and
its functions.
To avoid the risks that are always present when
you use an electrical appliance, it is important that
the air conditioner is installed correctly and that
you read the safety instructions carefully to avoid
misuse and hazards.
We recommend that you keep this instruction
booklet for future reference and pass it on to any
future owners.
After unpacking the air conditioner please check
it is not damaged. If in doubt, do not use the air
conditioner but contact your local authorised
service centre.
&RQGLWLRQVRIXVH
This appliance is intended to be used in
household and similar applications such as:
 6WDIINLWFKHQDUHDVLQVKRSVRI¿FHVDQGRWKHU
working environments.
 Farm houses.
 By clients in hotels, motels, and other
residential type environments.
 Bed and breakfast type environments.
,PSRUWDQWQRWHV
Contact an authorised installer for installation of
this unit.
Contact an authorised service technician for
repair or maintenance of this unit.
 The socket oultet required to supply power
must be connected and commissioned by a
licenced contractor.
 This appliance is not intended for use by
persons (including children) with reduced
physical, sensory or mental capabilities,
or lack of experience and knowledge,
unless they have been given supervision or
instruction concerning use of the appliance
by a person responsible for their safety.
 Young children should be supervised to
ensure that they do not play with the air
conditioner.
 If the power cord is to be replaced,
replacement work shall be performed by
authorised personnel only.
 Installation work must be performed
in accordance with the national wiring
standards and the electricity suppliers service
rules by authorised personnel only.
 If the unit is to be moved to another location
RUGLVSRVHGRIRQO\DVXLWDEO\TXDOL¿HG
person is permitted to undertake such work.
 7DNHFDUHQRWWRFDWFK¿QJHUVRQWKHIDQ
blade when adjusting vertical louvers.
 This air conditioner uses R410A refrigerant
&RQ¿UPEHIRUHLQVWDOODWLRQ
Information on disposal for users
 Most of the packing materials are recyclable.
Please dispose of those materials through
your local recycling depot or by placing them in
appropriate collection containers.
 If you wish to discard this air conditioner, please
contact your local authorities and ask for the
correct method of disposal.
FDXWLRQ
HQYLURQPHQWDO WLS
29
If you notice an unusal situation, such
as a burning smell, please switch off
the power to the air conditioner and
contact an authorised service agent. If
this abnormal status continues the air
conditioner may be damaged or even
FDXVHHOHFWULFVKRFNRU¿UH
Do not operate the air conditioner with
wet hands. This may cause electric
shock.
Do not damage or cut off the power cord
or other wires. If this occurs, please have
it repaired or replaced by an accredited
technician
Do not connect this air conditioner to a
multi outlet powerboard.
Please switch off the power supply to
the air conditioner if it is not to be used
for an extended period. Otherwise, it will
DFFXPXODWHGXVWDQGPD\FDXVHD¿UH
Before cleaning the air conditioner,
please disconnect the power supply in
order to eliminate the possibility of electric
shock.
The power supply should be matched
with the air conditioner according to
the installation manual. Air conditioners
provided with a supply cord should be
connected directly to a power outlet with
a suitable safety switch.
Air conditioners that are hard wired must
be connected to a suitable safety circuit
breaker according to the installation
manual.
Please ensure that the power supply to
the air conditioner is stable and meets the
requirements set out in the installation
manual.
Always ensure the product is installed
with appropriate earthing/grounding.
For safety, be sure to turn off the
circuit breaker before performing any
maintenance or cleaning or when the
product is not used for an extended
period of time. Accumulated dust may
FDXVH¿UHRUHOHFWULFVKRFN
6DIHW\SUHFDXWLRQV
,QVLGHWKLVPDQXDO\RXZLOO¿QGPDQ\KHOSIXOKLQWV
on how to use and maintain your air conditioner
properly. Just a little preventive care on your part
can save you a great deal of time and money over
WKHOLIHRI\RXUDLUFRQGLWLRQHU<RX¶OO¿QGPDQ\
answers to common problems in the chart of
troubleshooting tips on page 20-21. If you review the
FKDUWRIWURXEOHVKRRWLQJWLSV¿UVW\RXPD\QRWQHHG
to call for service.
Meanings of symbols used in this manual are shown
below:
This indicates information concerning your personal
safetyand how to avoid damaging the appliance.
This symbol indicates tips and information about use
of the appliance.
This symbol indicates tips and information about
economical and ecological use of the appliance.
This symbol indicates never to do this.
Always do this.
,PSRUWDQWQRWHV
1 Do not operate unit with horizontal louvre inclosed
position.
2 'RQRWRSHUDWHXQLWZLWKRXWWKHDLU¿OWHU
FDXWLRQ
ZDUQLQJ
HQYLURQPHQWDO WLS
WLSV DQG LQIRUPDWLRQ
30
6DIHW\SUHFDXWLRQV
8VDJH
([SRVXUHWRGLUHFWDLUÀRZIURPWKHDLU
conditioner for an extended period of time could
be hazardous to your health.
Do not expose people, pets or plants to the
GLUHFWDLUÀRZIRUDQH[WHQGHGSHULRG
&OHDQLQJDQGPDLQWHQDQFH
1 :KHQFOHDQLQJWKHXQLW¿UVWPDNHVXUHWKDW
the power and circuit breaker are turned off.
2 Do not touch the metal parts of the unit
ZKHQUHPRYLQJWKH¿OWHUV,QMXULHVFDQRFFXU
when handling sharp metal edges.
3 Do not use water to clean inside the air
conditioner. Exposure to water may lead to
possible electric shock.
6HUYLFH
For repair and maintenance, contact your
authorised service dealer.
3ULRUWR2SHUDWLRQ
1 &RQWDFWDQLQVWDOODWLRQTXDOL¿HGIRU
installation.
2 Plug in the power plug properly.
3 Do not use a damaged or non-standard
power cord.
4 Do not share the same outlet with other
appliances.
5 Do not use an extension cord.
6 Do not start/stop operation by plugging /
unplugging the power cord.
FDXWLRQ
Select the most appropriate temperature.
It can save electricity.
Do not keep windows and doors open for
a long time during operation. It will result
LQLQVXI¿FLHQWSHUIRUPDQFH
Do not block the air inlet or outlet.
,WZLOOUHVXOWLQLQVXI¿FLHQWSHUIRUPDQFH
and cause malfunctions.
Keep combustible materials away from
WKHXQLWVDWOHDVWP,WPD\FDXVH¿UH
Do not step on the top of the outdoor unit
or place heavy things on it.
It may cause damage or injury.
Do not attempt to repair the air
conditioner by yourself. Incorrect repairs
PD\FDXVHHOHFWULFVKRFNRU¿UH3OHDVH
contact your local authorised service
centre.
Do not insert your hands or objects into
the air inlet or outlet. It may cause injury.
Do not expose animals or plants directly
WRWKHDLUÀRZ
Do not use the unit for any other purpose,
such as preserving food or drying clothes.
Do not splash water on the air
conditioner. It may cause electric shock
or malfunction.
31
3URGXFW'HVFULSWLRQ
Air inlet
,QGRRU8QLW
Air Outlet
2XWGRRU8QLW Air inlet (rear)
Air inlet
(side)
Air inlet
(side)
Air Outlet
7KHDERYHGUDZLQJVDUHIRUH[SODQDWLRQSXUSRVHRQO\
<RXUDLUFRQGLWLRQHUPD\EHVOLJKWO\GLIIHUHQW
7KHDFWXDOVKDSHVKDOOSUHYDLO
1RWH
Display indicator
Mounting plate
Front panel
+HDOWK\DLU¿OWHU
EHKLQGWKHGXVW¿OWHU
'XVW¿OWHU
Horizontal air louver
Vertical air louver
(Behind the
horizontal air louver)
Manual control button
Cold plasma generator
Plasma dust collector
Remote control
Remote control holder
Power cable
Wall pipe
Binding tape
Refrigerant pipe
Drain hose
Connecting cable
Drain connector
32
5HPRWH&RQWURO
 The air conditioner will not operate if curtains,
doors or other materials block the signals from
the remote control to the indoor unit.
 Prevent any liquid from falling into the remote
control. Do not expose the remote control to
direct sunlight or heat.
 If the infrared signal receiver on the indoor
unit is exposed to direct sunlight, the air
conditioner may not function properly. Use
curtains to prevent the sunlight from falling on
the receiver.
 If other electrical appliances react to the
remote control, either move these appliances
or consult your local dealer.
,QGRRU8QLW'LVSOD\
Signal
receiver
 If you keep the remote control in a position that
hinders proper signal transmission, a time lag of
up to 15 minutes may occur.
Temperature
sensor
window
Back view
:KHQ,)((/RSHUDWLRQLVDFWLYDWHGWKHUHPRWH
FRQWUROVHQGVWKHWHPSHUDWXUHLQIRUPDWLRQDW
LWVORFDWLRQWRWKHLQGRRUXQLWHYHU\WHQ
PLQXWHV,IWKHLQGRRUXQLWGRHVQRWUHFHLYH
VXFKWHPSHUDWXUHLQIRUPDWLRQIRUVXFFHVVLYH
HOHYHQPLQXWHVWKHDLUFRQGLWLRQHUZLOO
TXLW,)((/RSHUDWLRQDQGUHYHUWWRQRUPDO
RSHUDWLRQ
+($7RSHUDWLRQLQGLFDWRU
It lights when the operation mode is HEAT.
&22/RSHUDWLRQLQGLFDWRU
It lights when the operation mode is COOL.
7HPSHUDWXUHLQGLFDWRU
Displays the temperature settings when the air
conditioner is in operation.
3RZHU212))LQGLFDWRU
It lights when the unit connected with power
supply.
'(+80,',)<RSHUDWLRQLQGLFDWRU
It lights when the operation mode is
DEHUMIDIFY.
+RZWRXVHWKH5HPRWH&RQWURO
 Point the remote control to the signal receiver of
indoor unit.
 :KHQWKHUHPRWHFRQWUROVHQGVRXWDVLJQDO
WKHV\PERO ZLOOEOLQNIRUDERXWVHFRQG
RQWKHGLVSOD\RIWKHUHPRWHFRQWURO7KH
LQGRRUXQLWZLOODFNQRZOHGJHWKHVLJQDOZLWKD
EHHSZKHQLWUHFHLYHVDQHIIHFWLYHVLJQDO
 Make sure there is no obstacle that may interfere
with the signal.
/RFDWLRQRIWKHUHPRWHFRQWURO
 .HHSWKHUHPRWHFRQWUROZKHUHLWVVLJQDO
FDQUHDFKWKHUHFHLYHURIWKHLQGRRUXQLWD
PD[LPXPGLVWDQFHRIPLVDOORZHG
 When you select the timer operation, the remote
control automatically transmits a signal to the
LQGRRUXQLWDWWKHVSHFL¿HGWLPH
FDXWLRQ
5HPLQGHU
33
4XLFN6WDUW*XLGH
6ZLQJ9DQG6ZLQJ+%XWWRQV
The swing buttons will allow you to select
horizontal (H) or vertical (V) swing of the air
guding louvers.
6OHHS%XWWRQ
Pressing this button to select sleep mode.
7LPHU2Q7LPHU2II%XWWRQV
Press to set automatic start and stop of the
conditioner.
/LJKW%XWWRQ
Press to switch the indicating lights of the indoor
unit on or off.
7XUER%XWWRQ
Press to put the fan into the high speed to allow
for rapid cooling or heating.
6SHFLDOIXQFWLRQV
;)$1
After the unit is turned off the indoor fan will continue
operation for 10 minutes to remove the moisture
of the indoor unit to avoid the growth of mould and
bacteria.
$ERXW$872UXQ
In this mode the set temperature will not be displayed
on the remote control, and the unit will automatically
judge and select the suitable operation method to
make ambient comfortable.
5HPRWHORFN
Press Swing-V and ION-Filter buttons simultaneously
to lock or unlock the keyboard. If the remote control
is locked, the icon will be displayed on it, in which
FDVHSUHVVDQ\EXWWRQWKHPDUNZLOOÀLFNHUWKUHH
times. If the keyboard is unlocked, the mark will
disappear.
6ZLWFKEHWZHHQ&HQWLJUDGHDQG)DKUHQKHLW
With the air conditioner switched off, press the
Swing-H and ION-Filter buttons simultaneously to
switch between °C and °F.
(QHUJ\VDYLQJ
In COOL mode, press ION-Filter and Clock buttons
simultaneously to start or stop energy saving
function. The remote control display will show “SE” in
temperature display area when it is active.
/RZKHDWPRGH
In HEAT mode, pressing ION-Filter and Clock buttons
simultaneously will put the air conditioner into a low
heat mode that will operate to a temperature of 8°C.
Repeat the operation to quit.
212))%XWWRQ
Press this button to turn the air conditioner
ON or OFF.
0RGH%XWWRQ
Press this button to select the desired operation
mode, AUTO, COOL, DEHUMIDIFY, FAN, and
HEAT.
&RQWURO%XWWRQ DQG
Press these two buttons to set the desired
temperature.
)DQ%XWWRQ
Press this button to set the fan speed at Auto,
Low, Medium-low, Medium, Medium -high, and
High.
COOL Power
DEHUMIDIFY Set temp
HEAT
34
4XLFN6WDUW*XLGH
AUTO mode is default while power on.
Under AUTO mode, the temperature will not be
displayed;
Under HEAT mode, the initial value is 28°C;
Under other modes, the initial value is 25°C.
&RQWURO%XWWRQ )RUZDUG
Press the button to increase the temperature
setting. holding this button down for 2 seconds
and more will increase the temperature setting
more quickly. Maximum setting is 30°C.
In Timer On/Off or Clock functions, use this
button to set the clock or timer adjustment.
&RQWURO%XWWRQ %DFNZDUG
Press the button to decrease the temperature
setting. holding this button down for 2 seconds
and more will decrease the temperature setting
more quickly. Maximum setting is 16°C.
In Timer On/Off or Clock functions, use this
button to set the clock or timer adjustment.
)DQ%XWWRQ
By pressing this button, Auto, Low, Medium-low,
Medium, Medium-high, and High speed can be
progressively selected.
When the unit is turned on, Auto fan speed is
the default.
,Q'(+80,',)<PRGHWKHIDQVSHHGLV¿[HGDW
Low speed.
212))%XWWRQ
Press this button to turn the air conditioner
ON or OFF.
Sleep function will be cancelled while the unit is
switched off.
0RGH%XWWRQ
By pressing this button, AUTO, COOL,
DEHUMIDIFY, FAN, and HEAT (COOL only
model has no HEAT feature) mode can be
selected progressively.
Low fan speed
Medium-low fan speed
Medium fan speed
Medium-high fan speed
High fan speed
The lower 12
buttons are
revealed by
sliding the panel
downwards
AUTO DEHUMIDIFY COOL FAN HEAT
35
7XUER%XWWRQ
Press this button in COOL or HEAT mode to
put the fan into the high speed Turbo mode
and the air conditioner will work at maximum
power.
The Turbo symbol will be displayed on the
remote control.
Turbo function will be cancelled if the Turbo
button is pressed again, or if the mode or fan
speed is changed.
6ZLQJ9%XWWRQ
Press this button, the horizontal louver will
swing up and down automatically, and will
be displayed on the remote control.
Press again to cancel it and the louver will
stay at its last position.
6ZLQJ+%XWWRQ
Press this button, the vertical louver will
swing left to right automatically, and will be
displayed on the remote control.
Press again to cancel it and the louver will
stay at its last position.
4XLHW%XWWRQ
Press this button the indoor fan operates at
ultra-low speed, the indoor noise is low.
symbol will be displayed on the remote
control once the Quiet function is activated.
Quiet function and Turbo function can not be
activated at the same time.
Quiet function will be cancelled if the Quiet
button is pressed again, or if the mode or fan
speed is changed.
6OHHS%XWWRQ
Pressing this button to select sleep mode ,
sleep mode , sleep mode and cancel the
Sleep mode.
STOP
 6OHHSPRGH
In COOL or DEHUMIDIFY mode, the set
temperature will increase 1°C after an hour,
and increase another 1°C after 2 hours, then
continue to run at this setting.
 6OHHSPRGH
In this mode, the air conditioner will run according
to a preset sleep temperature curve.
In COOL mode
(1) When setting the initial temperature between
16-23°C, after turning on the Sleep function,
the temperature will increase 1°C every hour,
after 3°C the temperature will be maintained,
after 7 hours, the temperature will be
decreased a further 1°C, after that the unit will
keep running at this temperature;
(2) When setting the initial temperature between
24-27°C, after turning on the Sleep function,
the temperature will increase 1°C every hour,
after 2°C the temperature will be maintained,
after 7 hours, the temperature will be
decreased a further 1°C, after that the unit will
keep running at this temperature;
(3) When setting the initial temperature between
28-29°C, after turning on the Sleep function,
WKHWHPSHUDWXUHZLOOLQFUHDVH&LQWKH¿UVW
hour, after 7 hours, the temperature will be
decreased a further 1°C, after that the unit will
keep running at this temperature;
(4) When setting the initial temperature to
30°C, after 7 hours the temperature will be
decreased 1°C, after that the unit will keep
running at this temperature.
In HEAT mode, the set temperature will decrease
1°C after an hour, and decrease another 1°C after
2 hours, then continue to run at this setting.
Set
Temperature
1 hour
1 hour
1 hour
1 hour
Set
Temperature