Elko iNels RFSAI-61B User manual

02-50/2015 Rev.1
RFSAI-61B
Wireless switch unit with the input
EN
L
N
1/5
☺
☺
☺
☺
RFRP-20
☺
Characteristics /
• The switching unit with 1 output channel is used for controlling appliances and lights. It is
possible to connect the existing button to the internal terminal in the wiring.
• It can be combined with Control or System units iNELS RF Control.
• T
he BOX design lets you mount it right in an installation box, a ceiling or controlled appliance cover.
• It enables connection of the switched load up to 16A (4.000 W).
• Function: button, impulse relay and time function of delayed start or return with time setting
range of 2s-60min.
• External button is programmed as a wireless button.
• Input is not galvanic isolated!
• The switching unit may be controlled by up to 32 channels (1 channel represents 1 button on
the controller).
• The programming button on the unit is also used for manual control of the output.
• Range up to 200 m (in open space), if the signal is insufficient between the controller and unit,
use the signal repeater RFRP-20.
• Communication frequency with bidirectional protocol iNELS RF Control.
Assembly / Connection /
mounting in an installation box
(even under the existing button / switch)
mounting into the light cover ceiling mounted
Radio frequency signal penetration through various construction materials /
60 - 90 % 80 - 95 % 20 - 60 % 0 - 10 % 80- 90 %
brick walls wooden structures
with plaster boards reinforced
concrete metal partitions common glass
Indication, manual control /
button /
terminal
board /
LED
• Terminal board - connection for external button.
• LED STATUS - indication of the device status.
• Manual control is performed by pressing the PROG button for
less than 1s.
• Programming is performed by pressing the PROG button for
more than 1s.
www.elkoep.com
ELKO EP, s.r.o. | Palackého 493 | 769 01 Holešov, Všetuly | Česká republika | e-mail: [email protected]
EN Support: +420 778 427 366 | CZ Technická podpora: +420 775 444 609
Spínací bezdrátový prvek se vstupem pro tlačítko
CZ
Charakteristika
• Spínací prvek s 1 výstupním kanálem slouží k ovládání spotřebičů a světel. Na interní svorku lze
připojit stávající tlačítko v elektroinstalaci.
• Lze je kombinovat s Ovladači nebo Systémovými prvky iNELS RF Control.
• Provedení BOX nabízí montáž přímo do instalační krabice, podhledu nebo krytu ovládaného
spotřebiče.
• Umožnuje připojení spínané zátěže do 16A (4000W).
• Funkce: tlačítko, impulsní relé a časové funkce zpožděného rozběhu nebo návratu s časovým
nastavením 2s-60 min.
• Externí tlačítko se programuje stejně jako bezdrátové.
• Vstup není galvanicky oddělený.
• Spínací prvek může být ovládán až 32 kanály (1 kanál představuje jedno tlačítko na ovladači).
• Programovací tlačítko na prvku slouží také jako manuální ovládání výstupu.
• Dosah až 200 m (na volném prostranství), v případě nedostatečného signálu mezi ovladačem a
prvkem použijte opakovač signálu RFRP-20.
• Komunikační frekvence s obousměrným protokolem iNELS RF Control.
Montáž Zapojení
montáž do instalační krabice
(i pod stávající tlačítko / vypínač)
montáž do krytu svítidla montáž do podhledu
Prostup radiofrekvenčních signálů různými stavebními materiály
cihlové zdi dřevěné konstrukce
se sádrokart.
deskami
vyztužený beton kovové přepážky běžné sklo
Indikace, manuální ovládání
tlačítko PROG svorkovnice
• Svorkovnice - připojení pro externí tlačítko.
• LED STATUS - indikace stavu přístroje.
• Manuální ovládní se provádí stiskem tlačítka PROG < 1s.
• Programování se provádí stiskem tlačítka PROG > 1s.

02-50/2015 Rev.1
RFSAI-61B
Wireless switch unit with the input
EN
13
PROG > 1s
1 x PROG >1s
1 x
13
PROG > 1s
1 x PROG >1s
1 x
1 x
1 x
3
PROG > 1s
1 x PROG >1s
1 x
1 x
1
2/5
Functions and programming with RF transmitters /
Function button /
Description of button /
The output contact will be closed by pressing the button and opened by releasing
the button.
Programming /
Press of programming button
on receiver RFSAI-61B for
1 second will activate receiver
RFSAI-61B into programming
mode. LED is flashing in 1s
interval.
Select and press one button on
wireless switch, to this button
will be assigned function
Button.
Press of programming button
on receiver RFSAI-61B shorter
then 1 second will finish
programming mode, LED
switches off.
Function switch on /
Description of switch on /
The output contact will be closed by pressing the button.
Programming /
Press of programming button
on receiver RFSAI-61B for
1 second will activate receiver
RFSAI-61B into programming
mode. LED is flashing in 1s
interval.
Two presses of your selected
button on the RF transmitter
assigns the function switch on
(must be a lapse of 1s between
individual presses).
Press of programming button
on receiver RFSAI-61B shorter
then 1 second will finish
programming mode (LED
switches off).
Function switch off /
Description of switch o /
The output contact will be opened by pressing the button.
Programming /
Press of programming button
on receiver RFSAI-61B for
1 second will activate receiver
RFSAI-61B into programming
mode. LED is flashing in 1s
interval.
Three presses of your selected
button on the RF transmitter
assigns the function switch off
(must be a lapse of 1s between
individual presses).
Press of programming button
on receiver RFSAI-61B shorter
then 1 second will finish
programming mode (LED
switches off).
2
1 x
2
2 x
2
3 x
www.elkoep.com
ELKO EP, s.r.o. | Palackého 493 | 769 01 Holešov, Všetuly | Česká republika | e-mail: [email protected]
EN Support: +420 778 427 366 | CZ Technická podpora: +420 775 444 609
Spínací bezdrátový prvek se vstupem pro tlačítko
CZ
Funkce a programování RF ovladači
Funkce tlačítko
Popis funkce tlačítko
Výstupní kontakt stiskem tlačítka sepne, uvolněním tlačítka rozepne.
Programování
Stiskem programovacího
tlačítka na prvku RFSAI-61B na
dobu 1 vteřiny se uvede prvek
do programovacího režimu.
LED bliká v intervalu 1 vteřiny.
Stisk Vámi zvoleného tlačítka
na RF ovladači přiřadí funkci
tlačítko. Stiskem programovacího
tlačítka na prvku RFSAI-61B na
dobu kratší než 1 vteřina se
ukončí programovací režim,
LED zhasne.
Funkce sepnout
Popis funkce sepnout
Výstupní kontakt stiskem tlačítka sepne.
Programování
Stiskem programovacího
tlačítka na prvku RFSAI-61B na
dobu 1 vteřiny se uvede prvek
do programovacího režimu.
LED bliká v intervalu 1 vteřiny.
Dva stisky Vámi zvoleného
tlačítka na RF ovladači
přiřadí funkci sepnout (mezi
jednotlivými stisky musí být
prodleva 1s).
Stiskem programovacího
tlačítka na prvku RFSAI-61B
na dobu kratší než 1 vteřina
se ukončí programovací režim
(LED zhasne).
Funkce vypnout
Popis funkce vypnout
Výstupní kontakt stiskem tlačítka rozepne.
Programování
Stiskem programovacího
tlačítka na prvku RFSAI-61B na
dobu 1 vteřiny se uvede prvek
do programovacího režimu.
LED bliká v intervalu 1 vteřiny.
Tři stisky Vámi zvoleného
tlačítka na RF ovladači
přiřadí funkci vypnout (mezi
jednotlivými stisky musí být
prodleva 1s).
Stiskem programovacího
tlačítka na prvku RFSAI-61B
na dobu kratší než 1 vteřina
se ukončí programovací režim
(LED zhasne).

02-50/2015 Rev.1
RFSAI-61B
Wireless switch unit with the input
EN
23
PROG > 1s
1 x PROG >1s
1 x
4 x
1 x
1 x
1
3
PROG > 5s
1 x
5
PROG < 1s
1 x
1
PROG > 1s
1 x
t = 2s . . . 60min.
3/5
Function impulse relay /
Description of impulse relay /
The output contact will be switched to the opposite position by each press of the
button. If the contact was closed, it will be opened and vice versa.
Programming /
Press of programming button
on receiver RFSAI-61B for
1 second will activate receiver
RFSAI-61B into programming
mode. LED is flashing in 1s
interval.
Four presses of your selected
button on the RF transmitter
assigns the function impulse relay
(must be a lapse of 1s between
individual presses).
Press of programming button
on receiver RFSAI-61B shorter
then 1 second will finish
programming mode (LED
switches off).
Funcion delayed off /
Description of delayed o /
The output contact will be closed by pressing the button and opened after the set
time interval has elapsed.
Programming /
Press of programming button
on receiver RFSAI-61B for
1 second will activate receiver
RFSAI-61B into programming
mode. LED is flashing in 1s
interval.
Assignment of the delayed off
function is performed by five
presses of the selected button
on the RF transmitter (must
be a lapse of 1s between
individual presses).
Press of programming button
longer then 5 seconds, will
activate actuator into timing
mode. LED flashs 2x in each
1s interval. Upon releasing the
button, the delayed return
time starts counting.
After the desired time has
elapsed (range of 2s...60min),
the timing mode ends by
pressing the button on the
RF transmitter, to which the
delayed return function is
assigned. This stores the set
time interval into the actuator
memory.
Press of programming button
on receiver RFSAI-61B shorter
then 1 second will finish
programming mode (LED
switches off).
4
1 x
2
5 x
www.elkoep.com
ELKO EP, s.r.o. | Palackého 493 | 769 01 Holešov, Všetuly | Česká republika | e-mail: [email protected]
EN Support: +420 778 427 366 | CZ Technická podpora: +420 775 444 609
Spínací bezdrátový prvek se vstupem pro tlačítko
CZ
Funkce impulsní relé
Popis funkce impulsní relé
Výstupní kontakt se každým stiskem tlačítka přepne na opačný stav. Pokud byl
sepnutý - rozepne, pokud byl rozepnutý - sepne.
Programování
Stiskem programovacího
tlačítka na prvku RFSAI-61B na
dobu 1 vteřiny se uvede prvek
do programovacího režimu.
LED bliká v intervalu 1 vteřiny.
Čtyři stisky Vámi zvoleného
tlačítka na RF ovladači přiřadí
funkci impulsní relé (mezi
jednotlivými stisky musí být
prodleva 1s).
Stiskem programovacího
tlačítka na prvku RFSAI-61B
na dobu kratší než 1 vteřina
se ukončí programovací režim
(LED zhasne).
Funkce zpožděný návrat
Popis funkce zpožděný návrat
Výstupní kontakt stiskem tlačítka sepne / rozepne po uplynutí nastaveného časo-
vého intervalu.
Stiskem programovacího
tlačítka na dobu 1 vteřiny
na prvku RFSAI-61B se prvek
uvede do programovacího
režimu. LED problikává ve
vteřinových intervalech.
Požadované přiřazení funkce
zpožděný návrat se provede
5-ti stisky zvoleného tlačítka na
RF ovladači (mezi jednotlivými
stisky musí být prodleva 1s).
Stisk programovacího tlačítka
delší než 5 vteřin uvede prvek
do časovacího režimu. LED
2x problikne ve vteřinových
intervalech. Po uvolnění
tlačítka se začne načítat čas
zpožděného návratu.
Poodčasování požadovaného
času (v rozmezí 2s ... 60min) se
časovací režim ukončí stiskem
tlačítka na RF ovladači, ke
kterému je přiřazena funkce
zpožděný návrat. Tím se
nastavený časový interval
uloží do paměti prvku.
Programování ukončí stisk
programovacího tlačítka na
prvku RFSAI-61B, kratší než 1
vteřina (LED zhasne).
Programování

02-50/2015 Rev.1
RFSAI-61B
Wireless switch unit with the input
EN
1 x
1
PROG > 1s
1 x
3
PROG > 5s
1 x
45
PROG < 1s
1 x
1 x
PROG > 5s
1 x PROG > 8s
1 x
xxxxxx
t = 2s . . . 60min.
4/5
Function delayed on /
Description of delayed on /
The output contact will be opened by pressing the button and closed after the set
time interval has elapsed.
Programming /
Press of programming button
on receiver RFSAI-61B for
1 second will activate receiver
RFSAI-61B into programming
mode. LED is flashing in 1s
interval.
Assignment of the delayed on
function is performed by six
presses of the selected button
on the RF transmitter (must
be a lapse of 1s between
individual presses).
Press of programming button
longer then 5 seconds, will
activate actuator into timing
mode. LED flashs 2x in each
1s interval. Upon releasing the
button, the delayed return
time starts counting.
After the desired time has
elapsed (range of 2s...60min),
the timing mode ends by
pressing the button on the
RF transmitter, to which the
delayed return function is
assigned. This stores the set
time interval into the actuator
memory.
Press of programming button
on receiver RFSAI-61B shorter
then 1 second will finish
programming mode (LED
switches off).
Programming with RF control units /
adress / The address listed on the front of the actuator is used for programming and
controlling actuators by RF control units.
Delete actuator /
Deleting one position of the transmitter /
By pressing the programming button on the actuator for
5 seconds, deletion of one transmitter activates. The LED
flashes in an interval of 1s.
Pressing the required button on the transmitter deletes it from
the actuator's memory.
The LED goes out and the actuator returns to operating mode.
Deleting the entire memory /
By pressing the programming button on the actuator for
8 seconds, deletion occurs of the actuator's entire memory. The
LED flashes three times and goes out, then again flashes three
times and goes out.
The actuator goes into the programming mode, the LED flashes
in 0.5s intervals (max. 4min.).
You can return to the operating mode by pressing the Prog
button for less than 1s.
2
6 x
www.elkoep.com
ELKO EP, s.r.o. | Palackého 493 | 769 01 Holešov, Všetuly | Česká republika | e-mail: [email protected]
EN Support: +420 778 427 366 | CZ Technická podpora: +420 775 444 609
Spínací bezdrátový prvek se vstupem pro tlačítko
CZ
Funkce zpožděný rozběh
Popis funkce zpožděný rozběh
Výstupní kontakt stiskem tlačítka rozepne / sepne po uplynutí nastaveného časo-
vého intervalu.
Programování
Stiskem programovacího
tlačítka na dobu 1 vteřiny
na prvku RFSAI-61B se prvek
uvede do programovacího
režimu. LED problikává ve
vteřinových intervalech.
Požadované přiřazení
funkce zpožděný rozběh se
provede 6-ti stisky zvoleného
tlačítka na RF ovladači (mezi
jednotlivými stisky musí být
prodleva 1s).
Stisk programovacího tlačítka
delší než 5 vteřin uvede prvek
do časovacího režimu. LED
2x problikne ve vteřinových
intervalech. Po uvolnění
tlačítka se začne načítat čas
funkce zpožděného rozběhu.
Poodčasování požadovaného
času (v rozmezí 2s ... 60min) se
časovací režim ukončí stiskem
tlačítka na RF ovladači, ke
kterému je přiřazena funkce
zpožděný rozběh. Tím se
nastavený časový interval
uloží do paměti prvku.
Programování ukončí stisk
programovacího tlačítka na
prvku RFSAI-61B, kratší než 1
vteřina (LED zhasne).
Programování RF systémovými prvky
adresa Pro programování a ovládání prvků RFSAI-61B RF systémovými prvky slouží
adresa, uvedená na přední straně prvku.
Mazání prvku
Mazání jedné pozice ovladače
Stiskem programovacího tlačítka na prvku RFSAI-61B na dobu
5-ti vteřin se aktivuje mazání jednoho ovladače. LED bliká v
intervalu 1s. Stisk tlačítka na ovladači ho z paměti prvku vymaže.
LED zhasne a prvek se vrátí do provozního režimu.
Vymazání celé paměti
Stiskem programovacího tlačítka na prvku RFSAI-61B na dobu
8 vteřin se vymaže celá paměť prvku. LED třikrát problikne,
zhasne, opět třikrát problikne a zhasne.
Prvek přejde do programovacího režimu, LED bliká v 0.5s
intervalech (max. 4min.).
Návrat do provozního režimu provedete stiskem Prog tlačítka
na dobu kratší než 1s.

02-50/2015 Rev.1
RFSAI-61B
Wireless switch unit with the input
EN
5/5
↯
Technical parameters /
Supplyvoltage:
Apparent power:
Dissipated power:
Supplyvoltagetolerance:
Output
Number of contacts:
Rated current:
Switching power:
Peak current:
Switching voltage:
Min. switching power DC:
Mechanical service life:
Electrical service life(AC1):
Controlling
RF command from the transmitter:
Manual control:
External button:
Rangein open space:
Other data
Voltageof open contact:
Resist. of connection for closed
contact:
Resist. of connection for open
contact:
Galvanic isolation of input:
Operating temperature:
Working position:
Mounting:
Protection:
Overvoltagecategory:
Contamination degree:
Terminals(CY wire, Cross-section):
Terminal length:
Dimensions:
Weight:
Related standards:
Control button input is at the supply voltage potential.
Warning
Instruction manual is designated for mounting and also for user of the device. It is always a part of its packing.
Installation and connection can be carried out only by a person with adequate professional qualification upon
understanding this instruction manual and functions of the device, and while observing all valid regulations.
Trouble-free function of the device also depends on transportation, storing and handling. In case you notice any
sign of damage, deformation, malfunction or missing part, do not install this device and return it to its seller. It
is necessary to treat this product and its parts as electronic waste after its lifetime is terminated. Before starting
installation, make sure that all wires, connected parts or terminals are de-energized. While mounting and servicing
observe safety regulations, norms, directives and professional, and export regulations for working with electrical
devices. Do not touch parts of the device that are energized – life threat. Due to transmissivity of RF signal, observe
correct location of RF components in a building where the installation is taking place. RF Control is designated only
for mounting in interiors. Devices are not designated for installation into exteriors and humid spaces. The must not
be installed into metal switchboards and into plastic switchboards with metal door – transmissivity of RF signal is
then impossible. RF Control is not recommended for pulleys etc. – radiofrequency signal can be shielded by an
obstruction, interfered, battery of the transceiver can get flat etc. and thus disable remote control.
↯
Attention:
The minimum distance between the controller (system unit) and the actuator must not be less
than one centimeter.
Between the individual commands must be an interval of at least 1s.
www.elkoep.com
ELKO EP, s.r.o. | Palackého 493 | 769 01 Holešov, Všetuly | Česká republika | e-mail: [email protected]
EN Support: +420 778 427 366 | CZ Technická podpora: +420 775 444 609
Spínací bezdrátový prvek se vstupem pro tlačítko
CZ
230VAC/ 50 -60 Hz120 VAC/ 60Hz12-24VAC/DC 50-60Hz
7VA / cos φ = 0.1 7VA / cos φ = 0.1 -
0.7W 0.7 W 0.7 W
+10 %; -15 %
1x switching /spínací (AgSnO2)
16 A/ AC1
4000 VA / AC1, 384 W / DC
30A/ <3 s
250 VAC1 / 24VDC
500 mW
3x107
0.7x105
868 MHz, 915 MHz, 916 MHz
button PROG / tlačítko PROG (ON/OFF)
max.12 mcable/ kabelu
up to / až 200 m
3V
<1kΩ
>10 kΩ
↯no / ne
-15 ... + 50 °C
any / libovolná
free at lead-in wires / volné na přívodních vodičích
IP30
III.
2
2x 0.75mm2, 2x 2.5 mm2
90 mm
49x 49x 21 mm
46g
EN 60669, EN 300220, EN 301489 R&TTE Directive, Order. No426/2000 Coll.(Directive 1999/EC)/
EN 60669, EN 300 220, EN 301 489 směrnice RTTE, NVč.426/2000Sb(směrnice 1999/ES)
Technické parametry
Napájecí napětí:
Příkon zdánlivý:
Příkon ztrátový:
Tolerance napájecího napětí:
Výstup
Počet kontaktů:
Jmenovitý proud:
Spínaný výkon:
Špičkový proud:
Spínané napětí:
Min. spínaný výkon DC:
Mechanická životnost:
Elektrická životnost (AC1):
Ovládání
RF povelem zovladače:
Manuální ovládání:
Externímtlačítkem:
Dosah na volném prostranství:
Další údaje
Napětí otevřeného kontaktu:
Odpor na vedení pro sepnuté
tlačítko:
Odpor na vedení pro
rozepnuté tlačítko:
Galvanické oddělení vstupu:
Pracovní teplota:
Pracovní poloha:
Upevnění:
Krytí:
Kategorie přepětí:
Stupeň znečištění:
Vývody (drát CY, průřez):
Délka vývodů:
Rozměr:
Hmotnost:
Související normy:
Vstup ovládacího tlačítka je na potenciálu síťového napájecího napětí.
Varování
Návod na použití je určen pro montáž a pro uživatele zařízení. Návod je vždy součástí balení. Instalaci a připojení
mohou provádět pouze pracovníci s příslušnou odbornou kvalifikací, při dodržení všech platných předpisů, kteří se
dokonale seznámili s tímto návodem a funkcí prvku. Bezproblémová funkce prvku je také závislá na předchozím
způsobu transportu, skladování a zacházení. Pokud objevíte jakékoliv známky poškození, deformace, nefunkčnosti
nebo chybějící díl tento prvek neinstalujte a reklamujte jej u prodejce. S prvkem či jeho částmi se musí po
ukončení životnosti zacházet jako s elektronickým odpadem. Před zahájením instalace se ujistěte, že všechny
vodiče, připojené díly či svorky jsou bez napětí. Při montáži a údržbě je nutné dodržovat bezpečnostní předpisy,
normy, směrnice a odborná ustanovení pro práci s elektrickými zařízeními. Nedotýkejte se částí prvku, které jsou
pod napětím - nebezpečí ohrožení života. Z důvodu prostupnosti RF signálu dbejte na správné umístění RF prvků
v budově, kde se bude instalace provádět. RF Control je určen pouze pro montáž do vnitřních prostor. Prvky
nejsou určeny pro instalaci do venkovních a vlhkých prostor, nesmí být instalovány do kovových rozvaděčů a do
plastových rozvaděčů s kovovými dveřmi - znemožní se tím prostupnost radiofrekvenčního signálu. RF Control se
nedoporučuje pro ovládání přístrojů zajišťujících životní funkce nebo pro ovládání rizikových zařízení jako jsou např.
čerpadla, el. topidla bez termostatu, výtahy, kladkostroje ap. - radiofrekvenční přenos může být zastíněn překážkou,
rušen, baterie vysílače může být vybita ap. a tím může být dálkové ovládání znemožněno.
Upozornění:
Minimální vzdálenost mezi ovladačem (systémovou jednotkou) a prvkem nesmí být menší než 1 cm.
Mezi jednotlivými povely musí být rozestup minimálně 1s.
Table of contents
Other Elko Switch manuals

Elko
Elko DIM-13 User manual

Elko
Elko RFSAI-62B-SL User manual

Elko
Elko HRH-5 User manual

Elko
Elko RFJA-12B/230V User manual

Elko
Elko CRM-42 User manual

Elko
Elko inels RFUS-61 User manual

Elko
Elko RFSA-11B User manual

Elko
Elko inels RFSA-166M User manual

Elko
Elko RFSA-11B User manual

Elko
Elko RFSA-62B User manual

Elko
Elko RFSA-66M User manual

Elko
Elko HRH-7 User manual

Elko
Elko CRM-4 User manual

Elko
Elko SmartDim EKO0727 Series User manual

Elko
Elko iNels RFSAI-62B User manual

Elko
Elko iNELS RFJA-12B User manual

Elko
Elko iNels RFJA-32B-SL User manual

Elko
Elko RFWB-20/G User manual

Elko
Elko RFSTI-11B-SL User manual

Elko
Elko EKO07115 User manual