manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. ENFORCER
  6. •
  7. Power Supply
  8. •
  9. ENFORCER SECO-LARM SLI PC-U0405-PULQ User manual

ENFORCER SECO-LARM SLI PC-U0405-PULQ User manual

®
12VDC Switching CCTV Power Supply
Manual
PC-U1820-PULQ shown
Model
Number
Number of
Outputs
Total Supply
Current
Max. Current
per Output
PC-U0405-PULQ 4 5A 1.6A
PC-U0910-PULQ 9 10A 1.6A
PC-U1810-PULQ 18 10A 1.1A
PC-U1820-PULQ 18 20A 1.6A
PC-U1830-PULQ 18 30A 1.85A
ENFORCER 12VDC Switching CCTV Power Supply
2SECO-LARM U.S.A., Inc.
Model PC-U0405-PULQ PC-U0910-PULQ PC-U1810-PULQ PC-U1820-PULQ PC-U1830-PULQ
Outputs 4 9 18 18 18
Total supply
current 5A 10A 10A 20A 30A
Max. current per
output 1.6A 1.1A 1.6A 1.85A
Output fuse PTC
Output voltage 11.0~13.8 VDC (adjustable by trimpot, ±10%)
Input voltage* 100~220 VAC ±10% (47~63 Hz) 110/220 VAC (50/60 Hz)
LED
Indicators
Cover Green: AC Input, Red: DC Output
PDM** Red: DC Output
Operating
humidity 90% (non-condensing)
Operating
temperature 32°~104° F (0°~40° C)
Dimensions 97/16"x101/4"x23/8" (240x260x60 mm) 10"x105/16"x31/8" (254x262x79 mm)
Weight 4-lb 3-oz
(1.89kg)
4-lb 7-oz
(2.01kg)
5-lb 2-oz
(2.31kg)
6-lb 1-oz
(2.76kg)
6-lb 4-oz
(2.84kg)
*UL listed for 90~120 VAC
**Power distribution module
Specifications:
Overview:
Features:
Parts List:
1x Power supply 1x Power cord 2x Rubber rings
2x Keys 1x Manual
100~220 VAC Input*
New lightweight, cost-effective design
Improved efficiency
Adjustable output to reduce voltage drop
Outputs protected with PTC fuses
Individual output status LEDs
Heavy-duty steel case with cover
Built-in short circuit and overheat protection
Output indicator LEDs
Power output terminals
Power output switch
Power input socket
Output voltage trimpot
(location varies)
ENFORCER 12VDC Switching CCTV Power Supply
SECO-LARM U.S.A., Inc. 3
Installation:
Power cable
knock-outs
Cam lock
Ventilation holes
Fig. 1 - Knock-Outs
Fig. 2 - Power Input Socket
Fig. 3 - Connecting power
outputs
Negative (-)
Positive (+)
Fig. 4 - Adjusting output
voltage
Min.
Max.
LED Indicator Status:
1. Find a suitable location to install the power supply.
The power supply should be installed out of sight,
and in a place protected from weather and high
humidity. The power supply must have adequate
ventilation. Insufficient ventilation may cause
overheating and damage could result.
2. Remove one of more of the cable knock-outs,
depending on how many connections will be made.
Knock-outs are shown in Fig. 1 to the right. If
desired, use an optional bushing, grommet, or other
sleeve to protect wires passing through the hole(s).
3. Screw the power supply to the wall or other mounting
surface using 5/32"x1" (4x26 mm) screws and plastic
anchors (not included). First, screw in the top
screw(s) and hang the power supply. Then, if
applicable, screw in the bottom two screws to fully
secure the unit in place.
4. Plug the power cable into the power input socket
(Fig. 2).
WARNING: Always test output voltage before
connecting devices to the power supply.
5. Connect cameras and other devices to the power
outputs, while observing correct polarity as shown in
Fig. 3. To minimize voltage drop, use 18-guage or
larger wire.
6. If voltage drop is large, adjust the output voltage
trimpot as shown in Fig. 4.
NOTE: The output voltage trimpot changes voltage for
all outputs by ±10%. Test all outputs to ensure
voltage does not exceed device specifications.
Location Color ON OFF
Cover
Green Connected to AC power No AC input
Red DC Output to PDM OK No DC output
Power distribution
module Red Terminal pair of output is
working correctly
Terminal pair of output has no
DC power
ENFORCER 12VDC Switching CCTV Power Supply
4SECO-LARM U.S.A., Inc.
Installation Notes:
Input Voltage Note (for PC-U1820-PULQ & PC-U1830-PULQ only):
NOTICE: The SECO-LARM policy is one of continual development and improvement. For that reason, SECO-LARM
reserves the right to change specifications without notice. SECO-LARM is also not responsible for misprints. All trademarks
are the property of SECO-LARM U.S.A., Inc. or their respective owners. Copyright © 2019 SECO-LARM U.S.A., Inc. All
rights reserved.
WARRANTY: This SECO-LARM product is warranted against defects in material and workmanship while used in normal
service for two (2) years from the date of sale to the original customer. SECO-LARM’s obligation is limited to the repair or
replacement of any defective part if the unit is returned, transportation prepaid, to SECO-LARM. This Warranty is void if
damage is caused by or attributed to acts of God, physical or electrical misuse or abuse, neglect, repair or alteration,
improper or abnormal usage, or faulty installation, or if for any other reason SECO-LARM determines that such equipment
is not operating properly as a result of causes other than defects in material and workmanship. The sole obligation of
SECO-LARM and the purchaser’s exclusive remedy, shall be limited to the replacement or repair only, at SECO-LARM’s
option. In no event shall SECO-LARM be liable for any special, collateral, incidental, or consequential personal or property
damage of any kind to the purchaser or anyone else.
IMPORTANT: Users and installers of this product are responsible for ensuring this product complies with all national,
state, and local laws and statutes. SECO-LARM will not be held responsible for the use of this product in violation of any
current laws or statutes.
Also Available from SECO-LARM®:
SECO-LARM
® U.S.A., Inc.
16842 Millikan Avenue, Irvine, CA 92606 Website: www.seco-larm.com
Phone:
(
949
)
261-2999
|
(
800
)
662-0800 Email: sales
@
seco-larm.com
PICSN7
MI_PC-Uxxxx-PULQ_190321.doc
x
CCTV Power
Supplies 12VDC AC Adapters Power Converters DC Connectors
PA-U0405-NULQ
shown
ST-UV12-S1.0Q
shown
ST-LA115-TPQ
shown
CA-161T / CA-151T
shown
ALWAYS TEST OUTPUT VOLTAGE BEFORE CONNECTING DEVICES.
Indoor use only. Do not mount the unit where it may be exposed to weather or high humidity.
For professional installation only.
Installation must conform to all local laws and building codes.
For 220VAC input voltage, locate the input voltage switch
on the bottom of the enclosure. Switch the input voltage
from 110V to 220V as shown in Fig. 5.
110V 220V
Fig. 5 - Input voltage switch

This manual suits for next models

4

Other ENFORCER Power Supply manuals

ENFORCER EVP-1SD2P4UL User manual

ENFORCER

ENFORCER EVP-1SD2P4UL User manual

ENFORCER EB-P501-01Q User manual

ENFORCER

ENFORCER EB-P501-01Q User manual

ENFORCER EVP-224D2-P4Q User manual

ENFORCER

ENFORCER EVP-224D2-P4Q User manual

ENFORCER SB-P1012-26Q User manual

ENFORCER

ENFORCER SB-P1012-26Q User manual

ENFORCER PS-U0406-PULQ User manual

ENFORCER

ENFORCER PS-U0406-PULQ User manual

ENFORCER EVP-1SA4P4UL User manual

ENFORCER

ENFORCER EVP-1SA4P4UL User manual

ENFORCER PH-U1820-PULQ User manual

ENFORCER

ENFORCER PH-U1820-PULQ User manual

ENFORCER ST-Series User manual

ENFORCER

ENFORCER ST-Series User manual

ENFORCER SECO-LARM SLI ST-2406-3AEQ User manual

ENFORCER

ENFORCER SECO-LARM SLI ST-2406-3AEQ User manual

ENFORCER PA-U0405-NULQ User manual

ENFORCER

ENFORCER PA-U0405-NULQ User manual

ENFORCER ST Series User manual

ENFORCER

ENFORCER ST Series User manual

ENFORCER PA-U0405-NULQ User manual

ENFORCER

ENFORCER PA-U0405-NULQ User manual

ENFORCER ENFORCER PH-A3224-PUQ User manual

ENFORCER

ENFORCER ENFORCER PH-A3224-PUQ User manual

ENFORCER EAP-5D1Q User manual

ENFORCER

ENFORCER EAP-5D1Q User manual

ENFORCER PC-L1620-PQ User manual

ENFORCER

ENFORCER PC-L1620-PQ User manual

ENFORCER ENFORCER ST Series User manual

ENFORCER

ENFORCER ENFORCER ST Series User manual

ENFORCER ST-1206-1.5AQ User manual

ENFORCER

ENFORCER ST-1206-1.5AQ User manual

Popular Power Supply manuals by other brands

PASCO SF-9582 instruction sheet

PASCO

PASCO SF-9582 instruction sheet

Kenwood PS-30 operating manual

Kenwood

Kenwood PS-30 operating manual

GEZE E260 Series Connection Schema

GEZE

GEZE E260 Series Connection Schema

Pulsar PSCL12070 quick start guide

Pulsar

Pulsar PSCL12070 quick start guide

Desoutter ESP2 manual

Desoutter

Desoutter ESP2 manual

Jantar SPIDER W40 quick start guide

Jantar

Jantar SPIDER W40 quick start guide

DuraComm LP-10 owner's guide

DuraComm

DuraComm LP-10 owner's guide

Agilent Technologies E3631-90002 user guide

Agilent Technologies

Agilent Technologies E3631-90002 user guide

WFCO WF-9900 Series Operator's manual

WFCO

WFCO WF-9900 Series Operator's manual

Altronix AL600X220 Series installation guide

Altronix

Altronix AL600X220 Series installation guide

Elmdene 2405STE manual

Elmdene

Elmdene 2405STE manual

BEGA 70 567 Instructions for use

BEGA

BEGA 70 567 Instructions for use

MRC PWR-3030 Operation manual

MRC

MRC PWR-3030 Operation manual

Energizer Arc3 quick start guide

Energizer

Energizer Arc3 quick start guide

TDK-Lambda LZS-A1500-3 Installation, operation and maintenance manual

TDK-Lambda

TDK-Lambda LZS-A1500-3 Installation, operation and maintenance manual

ELC ALR3003D instruction manual

ELC

ELC ALR3003D instruction manual

Rohde & Schwarz NGP800 Series Getting started

Rohde & Schwarz