ENFORCER Power Supplies/Chargers
2SECO-LARM U.S.A., Inc.
Wires for backup battery charger
Acrylic foam tape for PCB mount
(4x for ST-2406-7AQ and ST-2406- 0AQ)
(Continuous) .5A 2.0A 2.5A 4.0A 7.0A 9.0A
2V=220mA 6V= 00mA, 2V=220mA, 24V=450mA
temperature -4°~ 49° F (-20°~65° C)
Dimensions
series of power supplies/chargers ensure that alarm systems and access control systems
have enough power to do their job. Protected by fused outputs, input polarity protection diodes, and backup
battery polarity reverse protection, these power supplies/chargers can be used to maximize the security and
efficiency of nearly any alarm or access control installation.
Note: The LED, DIP switch, and terminal placement may be different on other models.
ST-2406-2AQ, ST-2406-3AQ,
and ST-2406-5AQ only.
Alarm or Access
Control Panel
VDC Output
Master Fuse
Voltage Selector DIP Switch
ENFORCER Power Supplies/Chargers
SECO-LARM U.S.A., Inc. 3
Mount the PC board in the desired location or enclosure. It
be easily accessible for future
servicing.
2. Set the DC power output:
a. Set the desired DC output voltage (6, 2, or 24VDC*) of the power
supply using the DIP switch as in Table (for ST- 206- .5AQ,
ST-2406-2AQ, ST-2406-3AQ, and ST-2406-5AQ), or Table 2 (for
ST-2406-7AQ, ST-2406- 0AQ) on the right.
IMPORTANT: Disconnect power before changing these DIP
switches (Note the default voltage output setting is 2VDC).
b. Connect a transformer with appropriate specifications (See
Table 3 below):
voltage ST 1206 1.5AQ ST 2406 2AQ ST 2406 3AQ ST 2406 5AQ ST 2406 7AQ ST 2406 10AQ
6VDC 2VAC/20VA 2VAC/20VA
28VAC/350VA
3. Connect the wires to their respective terminals (see "Wiring Diagram," pg. 2).
. Before connecting any external devices, temporarily power up the unit and measure the DC output
voltage to avoid damage to devices. Then disconnect power before connecting external devices.
2. LED status:
3. The ST- 206- .5AQ comes with a 3A fuse. The ST-2406-2AQ, ST-2406-3AQ, and ST-2406-5AQ models
come with a 5A fuse. The ST-2406-7AQ and ST-2406- 0AQ models come with a 0A fuse. Use only the
correct fuses to prevent short circuits and damage to the power supplies/chargers or the alarm access
control panel.
4. The automatic low battery cutoff will cut power when battery voltage drops below 20% of the set output
voltage (ST-2406-2AQ, ST-2406-3AQ, and ST-2406-5AQ only).
Warning:
. Using a higher AC input than recommended may damage the unit.
2. Avoid touching the heat sink to avoid injury. It may be very hot under full load.
3. DO NOT USE METAL SPACERS TO MOUNT THE POWER SUPPLY'S PC BOARD.
4. Connect these power supplies/chargers only to a rechargeable backup battery. Use of a non-
rechargeable backup battery could result in damage to the power supplies/chargers or the alarm access
control panel.