3.3 Specifications of Operation Panel
Figure 3.3.1 shows the external view of the panels and Table 3.3.1 shows the function of each part of the panels.
Fig. 3.3.1 External view of S5U1C88000H5 panels
Table 3.3.1 Function list of operation parts
No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Position
Side
Front
Front
Front
Front
Front
Front
Front
Front
Front
Front
Front
Back
Back
Function
The breaker cuts off the power of the S5U1C880000H5 system (ICE
board, Peripheral Circuit board and target board) at consumption
current of 4 A or more. A small staff of the breaker comes up at the
shut-off. The staff should be at the recessed position for normal
operating status. The breaker does not work at the normal operation.
Upon coincidence of trigger conditions with a tracing trigger point, a
pulse is output from this terminal.
When the S1C88 CPU is in HALT or SLEEP status, low level signal
is output from this terminal. This is used to measure execution rate
of the CPU. At the break mode, low level signal is also output.
Information is stored in the trace memory by connection with a
signal of the target system.
A running program enters in break status by input a low level signal
from the target system.
In case the above terminal is monitored with such an oscilloscope,
the GND line of the oscilloscope is connected to this terminal. This
is also used as a GND in case the signals are input to the above
terminals.
This green LED lights upon power-on of S5U1C880000H5.
This red LED lights when the target program is in running status.
This yellow LED lights when the S1C88 CPU stops executing the
program.
This switch reset S5U1C880000H5. (for maintenance)
Setting up when the S5U1C880000H5 power on, execute the self
diagnostic test or not
This is a connector to connect the USB interface cable.
This is a connector to connect the DC cable of the AC adapter
dedicated for S5U1C880000H5.
Turns the S5U1C880000H5 power on and off.
Indicated symbol
CB
TRGOUT
STOPOUT
TRCIN
BRKIN
GND
POWER
EMU
SLP/HLT
RESET
DIAG
DC 5V
POWER SW
Name
Circuit breaker
Tracing trigger output
terminal
HALT/SLEEP status
output terminal
Trace input terminal
Break input terminal
Ground terminal
for above
Power-on LED
Emulation LED
Halt LED
Reset switch
Diagnostic switch
Connector for connecting
USB interface cable
DC input connector
Power switch
Note: In case of change the mode by the diagnostic switch, be sure to shift it at power off the S5U1C88000H5.
POWER
CB
POWERSW
DC5VIN
EMU
SLP/HALT
RESET
TRGOUT
STOPOUT
TRCIN
BRKIN
GND
ICE88UR
E0C88 Family In-Circuit Emulator
ON
OFF
7 8 2
14
1
13
345610 12119
ON/OFF
DIAG
Front
Front ←
Back