Introduction
Preliminary
information
Safety notes
Installation and
part identification
Instructions
Suction
Instructions
Fibrelight
Technical data
Read these Instructions before use
Keep these ‘Instructions for use’ in a safe convenient place for future reference during
installation, operation and maintenance procedures.
Eschmann After Sales Service Department
The Eschmann After Sales Service Department is staffed and equipped to provide advice and
assistance during normal office hours. To avoid delays when making enquires, please quote the
Model and Serial Number of your Suction Unit and the part number of any part referred to.
(NOTE:ForlocationoftheSerialNumberPlateseebelow,thealphapartsoftheSNaresignificant).
Serial plate location for basic unit .....................................................inside vertical support
Serial plate location for unit with Fibrelight (only) ...............................back of Fibrelight unit
Serial plate location for unit with Suction ............................................. back of Suction unit
For further information visit www.eschmann.co.uk
All correspondence relating to the after sales service of Eschmann Equipment to be addressed to :
UK Customers
Eschmann Equipment, Peter Road, Lancing, West Sussex BN15 8TJ, England.
Tel: +44 (0) 1903 765040. Fax: +44 (0) 1903 762006.
Overseas Customers
Contact your local distributor. In case of doubt contact Eschmann Equipment.
Trade marks
The ESCHMANN name and logo are registered trade marks of Eschmann Holdings Limited.
“Eschmann Equipment” is a trading name of Eschmann HoldingsLimited.
“ST80” is a trade mark of Eschmann Holdings Limited.
Copyright © 2003
All rights reserved. This booklet is protected by copyright. No part of it may be reproduced, stored in a
retrieval system or transmitted in any form or by any means, electronic, mechanical, photocopying,
recording or otherwise without written permission from Eschmann HoldingsLimited.
The information in this publication was correct at the time of going to print. The Company, however,
reservesthe rightto modifyor improvethe equipmentreferred to.
If the CE mark is affixed to the product, it indicates compliance with Council Directive
93/42/EEC of 14 June 1993 concerning medical devices.
E-IM65c August 2003

E-IM65c P3/11
ST80
TROLLEY SYSTEM
CONTENTS
INTRODUCTION
Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
1. PRELIMINARY INFORMATION
General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Optional Extras . . . . . . . . . . . . . . . . . . . . . . . . . 4
2. SAFETY NOTES
Safetynotes . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
3. INSTALLATION & PART IDENTIFICATION
Unpacking &Assembly . . . . . . . . . . . . . . . . . . . 7
Electrical Connection. . . . . . . . . . . . . . . . . . . . . 7
PartsIdentification . . . . . . . . . . . . . . . . . . . . . . . 7
Important Operating Notes . . . . . . . . . . . . . . . . 7
4. INSTRUCTIONS FOR USE - SUCTION
Liner use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Starting the unit . . . . . . . . . . . . . . . . . . . . . . . . . 8
Suctionadjustment . . . . . . . . . . . . . . . . . . . . . . 8
Overflowprotection . . . . . . . . . . . . . . . . . . . . . . 8
Pump protection . . . . . . . . . . . . . . . . . . . . . . . . 8
Cleaning & Disinfection . . . . . . . . . . . . . . . . . . . 8
Sterilisation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Care - daily checks . . . . . . . . . . . . . . . . . . . . . . 9
Faultdiagnosis . . . . . . . . . . . . . . . . . . . . . . . . . 9
5. INSTRUCTIONS FOR USE - FIBRELIGHT
Attaching light guide . . . . . . . . . . . . . . . . . . . . 10
Using the fibrelight source . . . . . . . . . . . . . . . . 10
Lamp changing . . . . . . . . . . . . . . . . . . . . . . . . 10
Cleaning and Disinfection . . . . . . . . . . . . . . . . 10
6. TECHNICAL DATA
Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
FIGURES
Fig.1 ST80 Part identification . . . . . . . . . . . . . . . . 6
Fig.2 ST80 Changing fibrelight lamp . . . . . . . . . . 10
Fig.3 ST80 Fibrelight part identification . . . . . . . . 10
INTRODUCTION
NOTE: These Instructions for Use apply to the following
ST80 Trolley Units :-
REF 83-063-05 Electrosurgical trolley
REF 83-063-05-0002Trolleyplus Fibrelight,230V
REF 83-063-05-0004Trolley plusFibrelight, 110V
REF 83-063-05-0005Trolley plusSuction,
230V, 2 Jars
REF 83-063-05-0006Trolley plusSuction,
100/120V, 2 Jars
REF 83-063-05-0007Trolley plusSuction,
230V, 4 Jars
REF 83-063-05-0008Trolley plusSuction,
100/120V, 4 Jars
REF 83-063-05-0010Trolley+Fibrelight+Suction,
230V, 2 Jars
REF 83-063-05-0012Trolley+Fibrelight+Suction,
110V, 2 Jars
REF 83-063-05-0014Trolley+Fibrelight+Suction,
230V, 4 Jars
REF 83-063-05-0016Trolley+Fibrelight+Suction,
110V, 4 Jars
with Serial Number S8? B 8 B 0000 or later
(‘?’indicates model variant).

P4/11 E-IM65c
1. PRELIMINARY INFORMATION
GENERAL
1.1 The ST80 Trolley system is a modular piece of
theatre equipment available in a range of options:
a) Basic trolley.
b) Trolley with fibrelight system.
c) Trolley with suction system.
d) Trolley with both fibrelight and suction systems.
1.2 The reusable jars supplied with the suction unit are
used with a disposable liner system, as detailed on the
laminated leaflet S-IM08 enclosed with the ST80 Trolley if
a suction unit is fitted.
1.3 The mobile trolley has two breaking castors and a
flat working surface for an electrosurgical unit (optional
extra)or otherequipment. It also incorporates removable,
reversibleshelving.
1.4 All the information necessary to use the ST80Trolley
will be found in these Instructions for Use or the Jar and
liner card supplied (if applicable). Because of the modular
nature of this product not all sections of this booklet will
apply. For basic units refer to the relevant parts of the
cleaning and disinfection details section 4.8 - 4.9.
1.5 The following related publications, available from
Eschmann Equipment, also apply to the ST80 Trolley
System.
E-SM52 - Service Manual
S-IM08 - Instructions for Use
(disposable suction liner system)
OPTIONAL EXTRAS
Suction System (see Section 4 for details)
1.6 The vacuum pump is an oil-lubricated electrically-
driven pump/motor unit of the rotary vane type, with
replaceableblades. The motor unit is designed to operate
from the mains electrical supply. If required this module
can be added, please contact the Eschmann After Sales
Service Department (see inside front cover).
1.7 The pump/motor unit, its associated pipework and
electrical connections are all contained within a tough,
hygienicplastic case atthe base ofthe ST80. Controlsare
mounted on the top of the case and comprise an on/off
powerswitch,avacuumcontrolvalveandavacuumgauge.
1.8 A silencer unit in the pump exhaust line ensures
that the pump operates with the minimum of noise, while
thepumpinletisprotectedbyanexternallymountedsealed
bacterial or combined hydrophobic/bacterial filter both of
which are disposable.
Fibrelight System (see Section 5 for details)
1.9 The Fibrelightsystemisa fan-cooled,twin150 watt
Halogenlampunit, withbothFibrelight guide adaptersand
all controls accessible from the front of the system. Failed
lamps can be easily replaced without the need for any
special tools. If required this module can be added later,
please contact the Eschmann After Sales Service
Department (see inside front cover).
Twin Drip Pole Kit
1.10 The Twin Drip Pole Kit (REF 81-464-03) can be
fitted easily to either, or both sides, of the ST80 Trolley.
The Kit comes complete with all fittings and Instructions
for Use. It provides a conventional style twin drip stand,
takinguplessspace than anadditionalfree-standingpiece
of equipment.
ST80 Trolley System Accessories / Parts List
REF 82-961-68
Filters (pack of 10, bacterial)
REF 82-961-85
Filters (pack of 10, hydrophobic/bacterial)
REF 82-923-61
Jar (with V-mount for disposable liner)
REF 82-923-88
Tapered connector (pack of 10)
REF 82-923-96
Incineration box (pack of 25)
REF 82-929-14
Suction tubing 6.35mm i.d.
REF 82-930-15
Suction tubing (black) 12.7mm i.d.
REF 82-931-12
Suction tubing (clear) 12.7mm i.d.
REF 82-923-57
Disposable liner, standard bore 8.5mm (box of 25)
REF 82-923-69
Disposable liner, wide bore 12.5mm (box of 25)
REF 82-923-65
Disposableliner,Cascade,std.bore8.5mm(boxof25)
REF 82-929-36
Cascade connecting tube (box of 50)
REF 83-121-41
Fibrelight adaptor, to fit Storz/G.U. guides
REF 83-121-68
Fibrelight adaptor, to fit BS/ACMI guides
REF 81-464-03
ST80 Twin drip pole kit
PartNo.697603
Fibrelight lamp

E-IM65c P5/11
ST80
TROLLEY SYSTEM
2. SAFETY NOTES
When using the ESCHMANN ST80 TROLLEY
SYSTEM, attention to the following points will
prolong the life of your Trolley System and help
promote safe use.
DO clean all suction equipment and the unit thoroughly
after use.
DO change the disposable filter after each day’s use, or,
IMMEDIATELYifwetted,or,afteraspirationofinfective
fluids.
DO keep an adequate supply of spare disposable filters
handy.
DO unplug and/or isolate power lead before cleaning
suction unit and when not in use.
DO treat receiver jars carefully, avoiding mechanical or
thermal shock.
DO examineconditionofjarsandsuctiontubingregularly,
replacing if worn or damaged.
DO seal disposable liner after use and don’t reopen.
DO use a new liner and a new suction tube for each
patient - don’t risk cross infection.
DO autoclave receiver jar daily.
DO keep ‘sharps’ away from liners.
DO readthese‘InstructionsforUse’carefullyandkeepin
an accessible place.
DON’T start unit without removing transit bolt and filling
pump with oil.
DON’T use substitute disposable filters (see available
spares list on page 4).
DON’T continue to use unit, without attention, if vacuum
reading or suction rate is too low.
DON’T obstruct or cover ventilation holes in unit cabinet.
DON’T use the electrical power lead or suction tubing as
a tow rope, use the unit’s handle.
DON’T leave part filled liners in the system overnight -
always incinerate.
DON’T overfillsuctionliners-changewhenthreequarters
full.
DON’T use phenols or solvent based disinfectants to
clean receiver jar, use Savlon, Hibitane or similar
(also see leaflet S-IM08 supplied with the unit).
DON’T touch inside surface of fibrelight lamp reflector or
the quartz bulb.
WARNING
Operators of this unit should be aware of the
potential risks of ‘Cross Contamination’ and
‘Biological Contamination’ whilst using this
equipment. The correct procedures for the handling
of potentially contaminated components (e.g. Jar,
Tubing, Filters) and liquids should be followed
rigidly during Use, Cleaning and Maintenance.
Always change filters regularly and if they become
wettedor contaminated.All users should befamiliar
with the procedures for dealing with, and disposing
of, potentially contaminated components and
liquids. Suction equipment should only be used by
persons who have received adequate instructions
in its use.
The contents of the liner and accessories should
be disposed of safely and carefully, taking into
accountany National, Local or Hospital procedures,
covering the disposal of potentially contaminated
liquid, or solid, waste.
The maintenance procedures described in these
‘Instructions for Use’ should be made the
responsibility of the engineer in charge of services
in the hospital. If maintenance is neglected, suction
performance could be found inadequate in an
emergency situation. It is also recommended that if
placed on stand-by for emergency duty the unit is
tested by switching on, at regular intervals.
Table of contents
Other eschmann Medical Equipment manuals
Popular Medical Equipment manuals by other brands

Getinge
Getinge Arjohuntleigh Nimbus 3 Professional Instructions for use

Mettler Electronics
Mettler Electronics Sonicator 730 Maintenance manual

Pressalit Care
Pressalit Care R1100 Mounting instruction

Denas MS
Denas MS DENAS-T operating manual

bort medical
bort medical ActiveColor quick guide

AccuVein
AccuVein AV400 user manual