10 W1 Installation Manual
Before You Begin Installation
Review the following information before installing the F-Drive W1.
Installation Requirements
• Ambient operating temperature 0°C–40°C (32°F–104°F), 5%–95% non-condensing
humidity.
• Dry locations only.
• Refer to the
ArcSystem Navis 100 Installation Guide
for luminaire installation
requirements. All ETC documents are available for free download from our website:
etcconnect.com.
Power Disconnect Device
Before installation, make sure you have an accessible input power disconnect device installed
ahead of your F-Drive W1.
WARNING: RISK OF DEATH BY ELECTRIC SHOCK! Failure to disconnect all
power to the system before installation, maintenance, cleaning, or any other
system modification could result in serious injury or death.
AVERTISSEMENT : RISQUE DE MORT PAR DÉCHARGE ÉLECTRIQUE!
Négliger de débrancher toutes les sources d’alimentation du système avant
l’installation, l’entretien, le nettoyage ou toute autre modification du
système peut causer des blessures graves ou la mort.
De-energize main feed to F-Drive Power Control products and follow
appropriate Lockout/Tagout procedures as mandated by NFPA 70E. It is
important to note that electrical equipment such as breaker panels can
present an arc flash hazard if improperly serviced. This is due to the high
amounts of short-circuit current available on the electrical supply to this
equipment. Any work must comply with OSHA Safe Working Practices.
WARNING: RISK OF ELECTRIC SHOCK! Circuits that are installed without an
accessible power disconnect device cannot be serviced or operated safely.
AVERTISSEMENT : RISQUE DE DÉCHARGE ÉLECTRIQUE! Il est imprudent
d'utiliser ou de réparer les circuits installés sans qu'un dispositif de
déconnexion de l'alimentation ne soit accessible.
Third-Party Fixtures
The W1 CC Driver and W1 CV Driver support a wide variety of third-party loads. Determining
compatibility between these loads and the driver is an important step toward ensuring the
success of a project. Search the LED Dimming Compatibility Database at
etcconnect.com/compatibility to see if your load is compatible. If your load is not in the
compatibility database, follow the instructions at the link above to contact the ETC
Applications Engineering department to arrange for compatibility testing.
Visit the F-Drive System Design Tool (etcconnect.com/FDriveSysDesignTool) to design an F-
Drive R12 rack unit or F-Drive W1 driver with different luminaires, breakout boxes, cable
lengths, and other system components.