SECTION 1 - GENERAL DESCRIPTION.
Warning. Use only Water in this appliance.
This appliance must not be used for the heating of Liquid oils or Solid fats.
The units are provided with wire mesh basket(s) that may be drained by supporting them upon lift off draining board.
Water temperature is controlled by an adjustable users thermostat and a pre-set safety thermostat.
The multifunctional gas control (MFC), has pilot, main gas and flame failure controls built in. If pilot flame
extinguishes for any reason or if main gas supply is turned off, the burner will shut down until lighting procedure is
repeated.
A spark igniter is fitted to light pilot. A drain valve is located within controls compartment to empty pan when
necessary.
User Thermostat
This is an adjustable control that provides settings from 70°C through to continuous boil.
Safety Thermostat
This is pre-set at factory. In event of pan boiling dry, safety
thermostat will shut gas off at pilot and main burners.
If this occurs, the reason for failure must be investigated and rectified. The device is located next to burner control
(MFC) and is reset by removing black cap that protects button.
Ensure pan has cooled down before filling with cold water. Push reset button down gently using a slim, blunt
implement (i.e. a pen) and replace cap.
Warning: Filling an overheated pan with water is dangerous and may cause damage to pan structure.
Gas Control
Situated at left side of MFC, the control knob is set
correctly when appropriate symbol is alongside position
indicator. (See Figure 1)
Flame Failure Device
Operated by pilot flame. If pilot becomes extinguished, gas to main burner will be shut off.
Warning
If pilot is turned off for any reason, wait a minimum of
three minutes before attempting to relight it. The burner
control is built in to the flame failure device and the method of operation is detailed here.
Training and competence
To help ensure the safe use of this appliance there is a requirement for you to provide whatever information,
instruction, training and supervision as is necessary to ensure, so far as is reasonably practicable, the health and
safety of all users.
For further help and information on training and competence we would refer you the Health and Safety Executive
website; www.hse.gov.uk document ref: health and safety training INDG345. International customers should default
to the health and safety guidelines provided by your government body.
Risk assessment
As part of managing the health and safety of your business you must control any risks identified in your commercial
kitchen. To do this you need to think about what might cause harm to people and decide whether you are taking
reasonable steps to prevent that harm. This is known as risk assessment. It is important to consider the environment
around the product as well as the product itself. For example liquid or food spills will present a significant risk so
users so the need to immediately clean up such spills must be reflected in staff training.
For further help and information on risk assessments we would refer you to you the Health and Safety Executive
website; www.hse.gov.uk document ref: risk assessment INDG163. International customers should default to the
health and safety guidelines provided by your government body.