Fhiaba Integrated Series User manual

Installation guide
Notice d’installation


3
EN
1
1.1
1.2
IMPORTANT INSTRUCTIONS
Important safety instructions
Children safety
4
4
4
2
2.1
2.2
2.3
2.4
2.5
2.6
2.7
TECHNICAL REQUIREMENTS
Appliance features and installation requirements
Installation niche features: Integrated Series
Installation niche features: Integrated Series
Installation niche features: StandPlus
Installation niche features: X-Pro
Installation niche features: Brilliance-Integrated
Installation niche features: Brilliance-Classic
4
4
6
7
8
9
10
11
3
3.1
3.2
3.3
3.4
PREPARING THE INSTALLATION
Transport to installation site and unpacking
Electrical and Water connection
Energy: Alternatives and Home Automation
Levelling
12
12
12
13
14
4
4.1
4.2
4.3
4.4
4.5
NICHE DIMENSIONS
Niche Dimensions and Installation Styles: Integrated Series
Niche Dimensions and Installation Styles: StandPlus and X-Pro Series
Flush installation with standard aluminum trims
Prominent installation with standard aluminum trims
Stand-Proud (for StandPlus and X-Pro series)
14
14
15
15
15
16
5
5.1
5.2
5.3
5.4
5.5
5.6
5.7
5.8
5.9
5.10
5.11
5.12
5.13
PANELS MOUNTING
Decorative door and Bottom-Drawer panels layout
Decorative panels layout for Fridge with one Bottom-Drawer
Decorative panels layout for Fridge Brilliance
Decorative panels layout for Fridge with two Bottom-Drawers
Decorative panels layout for Fridge with Glass door and one Bottom-Drawer
Decorative panels layout for Fridge with Glass door and two Bottom-Drawers
Decorative panels layout for Fridge Column
Decorative panels layout for Fridge column with glass door
Panels Dimensions Single Bottom - Drawer
Panels Dimensions Two Bottom - Drawers
Panels Dimensions Column Models
Mounting the handles
Mounting panels to the door and the drawer
16
16
18
19
20
21
22
23
24
25
26
27
28
28
6
6.1
6.2
INSTALLATION
Built-in installation of single appliance
Built-in installation of two or more appliances
30
30
30
7
7.1
7.2
7.3
7.4
7.5
COMPLETING THE INSTALLATION
Anti-tipping safety assembly
Mounting the handles on stainless front
Ventilation
Post installation control
Start Up
32
32
33
33
34
34
INDEX EN

4www.fhiaba.com · [email protected]
1.1 Important safely instruction
Symbols used in the Guide:
Note
Tips for the correct use of the appliance
Important
Directions to avoid appliance damage
Warning
directions to prevent injury
1.2 Children safety
DANGER: Risk of child entrapment. Before you throw
away your old refrigerator or freezer:
> Take o the doors
>Leave the shelves in place so that children may not
easily climb inside.
Important!
Dimensions in parentheses are in inches.
Weights in parentheses are in pounds.
Temperatures in parentheses are
in Fahrenheit degrees.
1.IMPORTANT INSTRUCTIONS
Appliance
dimensions
Integrated
Series 599 / 24”
w: 599 mm (23 5/8”)
h: 2120 mm (83 1/2”)
d: 610 mm (24”)
Series 749 / 30”
w: 749 mm (29 1/2”)
h: 2120 mm (83 1/2”)
d: 610 mm (24”)
Series 899 / 36”
w: 899 mm (35 3/8”)
h: 2120 mm (83 1/2”)
d: 610 mm (24”)
Appliance
dimensions
StandPlus
Series 599 / 24”
w: 599 mm (23 5/8”)
h: 2120 mm (83 1/2”)
d: 629 mm (24 3/4”)
Series 749 / 30”
w: 749 mm (29 1/2”)
h: 2120 mm (83 1/2”)
d: 629 mm (24 3/4”)
Series 899 / 36”
w: 899 mm (35 3/8”)
h: 2120 mm (83 1/2”)
d: 629 mm (24 3/4”)
Appliance
dimensions
X-Pro
Series 599 / 24”
w: 599 mm (23 5/8”)
h: 2120 mm (83 1/2”)
d: 635 mm (25”)
Series 749 / 30”
w: 749 mm (29 1/2”)
h: 2120 mm (83 1/2”)
d: 635 mm (25”)
Series 899 / 36”
w: 899 mm (35 3/8”)
h: 2120 mm (83 1/2”)
d: 635 mm (25”)
Appliance
dimensions
Brilliance
-Integrated
Series 599 / 24”
w: 599 mm (23 5/8”)
h: 2120 mm (83 1/2”)
d: 610 mm (24”)
Series 749 / 30”
w: 749 mm (29 1/2”)
h: 2120 mm (83 1/2”)
d: 610 mm (24”)
Series 899 / 36”
w: 899 mm (35 3/8”)
h: 2120 mm (83 1/2”)
d: 610 mm (24”)
2.1 Appliance features and installation
requirements
2. TECHNICAL REQUIREMENTS

EN
5
EN
Appliance
dimensions
Brilliance-Classic
Series 599 / 24”
w: 599 mm (23 5/8”)
h: 2120 mm (83 1/2”)
d: 635 mm (25”)
Series 749 / 30”
w: 749 mm (29 1/2”)
h: 2120 mm (83 1/2”)
d: 635 mm (25”)
Series 899 / 36”
w: 899 mm (35 3/8”)
h: 2120 mm (83 1/2”)
d: 635 mm (25”)
Packaging
dimensions
Integrated /
Brilliance
Series 599 / 24”
w: 650 mm (25 5/8”)
h: 2210 mm (87”)
d: 800 mm (31 1/2”)
Series 749 / 30”
w: 800 mm (31 1/2”)
h: 2210 mm (87”)
d: 800 mm (31 1/2”)
Series 899 / 36”
w: 950 mm (37,4 in)
h: 2210 mm (87”
d: 800 mm (31 1/2”)
Packaging
dimensions
StandPlus / X-Pro
Series 599 / 24”
w: 650 mm (25 5/8”)
h: 2260 mm (89”)
d: 800 mm (31 1/2”)
Series 749 / 30”
w: 800 mm (31 1/2”)
h: 2260 mm (89”)
d: 800 mm (31 1/2”)
Series 899 / 36”
w: 950 mm (37 3/8”)
h: 2260 mm (89”)
d: 800 mm (31 1/2”)
Weight with
packaging Series 599 / 24”
up to 230 kg (507 lb)
Series 749 / 30”
up to 275 kg (606 lb)
Series 899 / 36”
up to 295 kg (650 lb)
Voltage Europe Version:
AC 220-240V 50 Hz
North America Version:
110V 60Hz
Power supply
cable Europe Version:
Schuko 16 A plug
North America Version:
15 A
Potable water
supply pressure from 0.05 MPa to 0.5 MPa
(0.5 Bar - 5 Bar)
Water supply
tube 3/4” female attachment
Provided
installation
accessories
- Customized panels
mounting Kit
- Anti-tipping Kit (B04000200)
- Lateral connecting kit
(KCLIT/KCLIH)
- 4 mm (1/8”) allen wrench
Additional
equipment
necessary
- Phillips head screwdriver
- wood and percussion drill
- 2.5 mm (1/8”) bit for wood
- 8 mm (3/8”) bit for walls
- 17 mm (3/4”) wrench

6www.fhiaba.com · [email protected]
2.2 Installation niche features:
Integrated Series
A - area to be left clear for the anti-tipping brackets
Minimum Niche Height
2134 mm (84”)
Minimum Niche Width
S899 / FI36: 900 mm (35 1/2”)
S749 / FI30: 750 mm (29 5/8”)
S599 / FI24: 600 mm (23 3/4”)
Minimum Niche Depth
650 mm (25 5/8”)
Door Swing Clearance
S899 / FI36: 1470 mm (57 7/8”)
S749 / FI30: 1320 mm (52”)
S599 / FI24: 1170 mm (46”)
Door Opening Angle
105°
Width
S899 / FI36: 899 mm (35 3/8”)
S899 / FI36: 749 mm (29 1/2”)
S899 / FI36: 599 mm (23 5/8”)
Height
2120 mm (83 1/2”) + 25 mm (1”)
Depth with door (without panel)
610 mm (24”)
Minimum distance from the wall (hinge side)
S899: 160 mm (6 1/4”)
S749: 125 mm (5”)
S599: 90 mm (3 1/2”)
Dimensions in parentheses
are in inches.
2. TECHNICAL REQUIREMENTS
248 (9
¾”
)
+ 25 (1”)
330
(13”)
259
(10
¼”
)
min 2134 (84”)
A A
140 (5 ½”) 140 (5 ½”)
100 (4”)
100 (4”)
S899 / FI36: 900 (35 ½”)
S599 /FI24: 600 (23 ¾”)
S749 / FI30: 750 (29 ⅝”)
610 (24”)
560 (22”)
610 (24”)
560 (22”)
1293 (50 ⅞” )
474
(18 ⅝”)
231 (9
⅛”
) +
25 (1”)
500 (19 ¾”)
500 (19 ¾”)
248 (9
¾”
)
+ 25 (1”)
231 (9
⅛”
) +
25 (1”) 20 (¾”)
20 (¾”)10 (⅜”)
721 (28 ⅜”) +25 (1”)
2120 (83 ½”) +25 (1”)
846 (33 ¼”) +25 (1”)
2120 (83 ½”) +25 (1”)
1168(46”)
105°
560 (22”)
610 (24”)
899 / FI36: 899 (35 ⅜”)
749 / FI30: 749 (29 ½”)
599 / FI24: 599 (23 ⅝”)
10 (⅜”)
992 (39”)
899 / FI36: 1470 (57 ⅞”)
749 / FI30: 1320 (52”)
599 / FI24: 1170 (46”)
899 / FI36: 160 (6 ¼”)
749 / FI30: 125 (5”)
599 / FI24: 90 (3 ½”)

EN
7
EN
2.3 Installation niche features:
Integrated Series
A - area to be left clear for the anti-tipping brackets
Minimum Niche Height
2064 mm (81 1/4”)
Minimum Niche Width
S899 / FI36: 900 mm (35 1/2”)
S749 / FI30: 750 mm (29 5/8”)
S599 / FI24: 600 mm (23 3/4”)
Minimum Niche Depth
650 mm (25 5/8”)
Door Swing Clearance
S899 / FI36: 1475 mm (58”)
S749 / FI30: 1325 mm (52 1/8”)
S599 / FI24: 1175 mm (46 1/4”)
Door Opening Angle
105°
Width
S899 / FI36: 899 mm (35 3/8”)
S899 / FI36: 749 mm (29 1/2”)
S899 / FI36: 599 mm (23 5/8”)
Height
PPŘPPŘ
Depth with door (without panel)
615 mm (24 1/4”)
Minimum distance from the wall (hinge side)
S899: 160 mm (6 1/4”)
S749: 125 mm (5”)
S599: 90 mm (3 1/2”)
Dimensions in parentheses
are in inches.
233 (9
¼”
)
+ 25 (1”)
min 2134 (84”)
A A
140 (5 ½”) 140 (5 ½”)
100 (4”)
100 (4”)
S899 / FI36: 900 (35 ½”)
S599 /FI24: 600 (23 ¾”)
S749 / FI30: 750 (29 ⅝”)
610 (24”)
560 (22”)
1808 (71 ¼” )
231 (9
⅛”
) +
25 (1”)
500 (19 ¾”)
2120 (83 ½”) +25 (1”)
105°
992 (39 ¼”)
S899 / FI36: 1475 (58”)
S749 / FI30: 1325 (52 ⅛”)
S599 / FI24: 1175 (46 ¼”)
565 (22 ¼”)
615 (24 ¼”)
S899 / FI36: 899 (35 ⅜”)
S749 / FI30: 749 (29 ½”)
S599 / FI24: 599 (23 ⅝”)
10 (⅜”)
S899 / FI36: 160 (6 ¼”)
S749 / FI30: 125 (5”)
S599 / FI24: 90 (3 ½”)

8www.fhiaba.com · [email protected]
2. TECHNICAL REQUIREMENTS
2.4 Installation niche features:
StandPlus Series
A - area to be left clear for the anti-tipping brackets
Minimum Niche Height
2134 mm (84”)
Minimum Niche Width
MS899 / FM36: 900 mm (35 1/2”)
MS599 / FM24: 600 mm (23 3/4”)
Door Swing Clearance
MS899 / FM36: 1470 mm (57 7/8”)
MS599 / FM24: 1170 mm (46”)
Door Opening Angle
105°
Width
MS899 / FM36: 899 mm (35 3/8”)
MS599 / FM24: 599 mm (23 5/8”)
Height
2120 mm (83 1/2”) + 25 mm (1”)
Depth with door
629 mm (24 3/4”)
Minimum distance from the wall (hinge side)
MS899 / FM36: 230 mm (9”)
MS599 / FM24: 160 mm (6 1/4”)
Important!
If the units are to be installed inside a
niche or within an enclosed structure, it
is necessary to design a ventilation shaft
at the back of the niche to assure proper
ventilation at the back of the unit.
Dimensions in parentheses
are in inches.
A A
140 (5 ½”) 140 (5 ½”)
100 (4”)
100 (4”)
min 2134 (84”)
MS899 / FM36: 900 (35 ½”)
MS599 / FM24: 600 (23 ¾”)
560 (22”)
2120 (83 ½”) +25 (1”)
613 (24 ⅛”)+25 (1”)
629 (24 ¾”)
615 (24 ¼”)
666 (26 ¼”)
485 (19 ⅛”) 1296 (50”)
195 (7 ⅝”)
8 (⅜”) 8 (⅜”)
128 (5)
+ 25 (1”)
min 10 (⅜”)
min 50 (2”)
105°
1010 (39 ¾”)
560 (22”)
MS899 / FM36: 899 (35 ⅜”)
MS599 / FM24: 599 (23 ⅝”)
10 (⅜”)
629 (24 ¾”)
37 (1 ½”)
69 (2 ¾”)
MS899 / FM36: 1470 (57 ⅞”)
MS599 / FM24: 1170 (46”)
MS899 / FM36: 230 (9”)
MS599 / FM24: 160 (6 ¼”)

EN
9
EN
2.5 Installation niche features:
X-Pro Series
A - area to be left clear for the anti-tipping brackets
Minimum Niche Height
2134 mm (84”)
Minimum Niche Width
XS899 / FP36: 900 mm (35 1/2”)
XS749 / FP30: 750 mm (29 5/8”)
XS599 / FP24: 600 mm (23 3/4”)
Door Swing Clearance
XS899 / FP36: 1470 mm (57 7/8”)
XS749 / FP30: 1320 mm (52”)
XS599 / FP24: 1170 mm (46”)
Door Opening Angle
105°
Width
XS899 / FP36: 899 mm (35 3/8”)
XS749 / FP30: 749 mm (29 1/2”)
XS599 / FP24: 599 mm (23 5/8”)
Height
2120 mm (83 1/2”) + 25 mm (1”)
Depth with door
635 mm (25 ”)
Minimum distance from the wall (hinge side)
XS899 / FP36: 230 mm (9”)
XS749 / FP30: 195 mm (7 3/4”)
XS599 / FP24: 160 mm (6 1/4”)
Important!
If the units are to be installed inside a
niche or within an enclosed structure, it
is necessary to design a ventilation shaft
at the back of the niche to assure proper
ventilation at the back of the unit.
Dimensions in parentheses
are in inches.
A A
140 (5 ½”) 140 (5 ½”)
100 (4”)
100 (4”)
min 2134 (84”)
XS899 / FP36: 900 (35 ½”)
XS599 /FP24: 600 (23 ¾”)
XS749 / FP30: 750 (29 ⅝”)
560 (22”)
2120 (83 ½”) +25 (1”)
613 (24 ⅛”)+25 (1”)
635 (25”)
693 (27 ¼”)
516 (20 ⅜”) 1296 (50”)
195 (7 ⅝”)
8 (⅜”) 8 (⅜”)
97 (3 ⅞”)
+ 25 (1”)
1016 (40”)
XS899 / FP36: 1470 (57 ⅞”)
XS749 / FP30: 1320 (52”)
XS599 / FP24: 1170 (46”)
560 (22”)
75 (3”)
XS899 / FP36: 899 (35 ⅝”)
XS749 / FP30: 749 (29 ½”)
XS599 / FP24: 599 (23 ⅝”)
10 (⅜”)
58 (2 ¼”)
105°
635 (25”)
XS899 / FP36: 230 (9”)
XS749 / FP30: 195 (7 ¾”)
XS599 / FP24: 160 (6 ¼”)
min 10 (⅜”)
min 50 (2”)

10 www.fhiaba.com · [email protected]
2.6 Installation niche features:
Brilliance-Integrated Series
A - area to be left clear for the anti-tipping brackets
Minimum Niche Height
2064 mm (81 1/4”)
Minimum Niche Width
899 / BI36: 900 mm (35 1/2”)
749 / BI30: 750 mm (29 5/8”)
Minimum Niche Depth
615 mm (24 1/4”)
Door Swing Clearance
899 /BI36: 1435 mm (56 1/2” in)
749 / BI30:: 1285 mm (50 5/8” in)
Door Opening Angle
105°
Width
899 /BI36: 899 mm (35 3/8”)
749 / BI30:: 749 mm (29 1/2”)
Height
PPŘPPŘ
Depth with door (without panel)
575 mm (22 5/8” in)
Minimum distance from the wall (hinge side)
899 /BI36: 160 mm (6 1/4”)
749 / BI30:: 125 mm (5”)
Dimensions in parentheses
are in inches.
2. TECHNICAL REQUIREMENTS
105°
560 (22”)
610 (24”)
899 / BI36: 899 (35 ⅜”)
749 / BI30: 749 (29 ½”)
10 (⅜”)
992 (39”)
899 / BI36: 1470 (57 ⅞”)
749 / BI30: 1320 (52”)
899 / BI36: 160 (6 ¼”)
749 / BI30: 125 (5”)
A A
140 (5 ½”) 140 (5 ½”)
100 (4”)
100 (4”)
min 2064 (81 ¼”)
899 / BI36: 900 (35 ½”)
749 / BI30: 750 (29 ⅝”)
610 (24”)
560 (22”)
1293 (50 ⅞” )
474
(18 ⅝”)
231 (9
⅛”
) +
25 (1”)
500 (19 ¾”)
248 (9
¾”
)
+ 25 (1”)
20 (¾”)
721 (28 ⅜”) +25 (1”)
2120 (83 ½”) +25 (1”)

EN
11
EN
2.7 Installation niche features:
Brilliance-Classic Series
A - area to be left clear for the anti-tipping brackets
Minimum Niche Height
2064 mm (81 1/4”)
Minimum Niche Width
899 / BKI36: 900 mm (35 1/2”)
749 / BKI30: 750 mm (29 5/8”)
Minimum Niche Depth
615 mm (24 1/4”)
Door Swing Clearance
899 / BKI36: 1435 mm (56 1/2” in)
749 / BKI30: 1285 mm (50 5/8” in)
Door Opening Angle
105°
Width
899 / BKI36: 899 mm (35 3/8”)
749 / BKI30: 749 mm (29 1/2”)
Height
PPŘPPŘ
Depth with door
600 mm (23 3/4” in)
Minimum distance from the wall (hinge side)
899 / BKI36: 230 mm (9”)
749 / BKI30: 195 mm (7 3/4”)
Dimensions in parentheses
are in inches.
A A
140 (5 ½”) 140 (5 ½”)
100 (4”)
100 (4”)
min 2134 (84”)
899 / BKI36: 900 (35 ½”)
749 / BKI30: 750 (29 ⅝”)
2120 (83 ½”) +25 (1”)
635 (25”)
560 (22”)
693 (27 ¼”)
1378 (54 ¼”)587 (23 ⅛”)
146 (5 ¾”)
+ 25(1”)
9 ( ⅜”)
732 (28 ⅞”)+25 (1”)
105°
899 / BKI36: 1470 (57 ⅞”)
749 / BKI30: 1320 (52”)
560 (22”)
635 (25”)
899 / BKI36: 899 (35 ⅜”)
749 / BKI30: 749 (29 ½”)
10 (⅜”)
75 (3”)
58 (2 ¼”)
899 / BKI36: 230 (9”)
749 / BKI30: 195 (7 ¾”)
1016 (40”)

12 www.fhiaba.com · [email protected]
3.1 Transport to installation site
and unpacking
The appliance is very heavy.
Take maximum care during handling
to avoid injury.
The appliance should always be
transported in an erect position.
Avoid at all costs leaning it on its front
side.
Since this is a large and heavy appliance,before trans-
porting the appliance, check the access to the loca-
tion where it will be installed (door size, manoeuvring
space in stairwells, etc.).
The appliance is attached to the base of the packaging
(pallet) through four bolts which can be removed us-
ing a 17 mm (3/4”) wrench.
It is recommended to use a manual transporting de-
vice to move the appliance to the installation site, and
only at this point to remove the base of the packaging.
The appliance should always be transported in an
erect position.
If this is not possible, transport the appliance laying
on its rear side.
Once at the installation site, the appliance, which is
equipped with four wheels, can be taken o the pallet
and positioned in the installation area.
Operate as follows:
> Take o the four boltshsecuring [ 1 ] the appliance to
the pallet by means of a 17 mm (3/4”) open spanner.
>Remove the fixing brackets [ 3 ] and [ 4 ] .
>To remove the front fixing bracket [ 3 ] , unscrew for
one or two turns the rear wheel adjusting bolt [ 2 ] by
means of a 13 mm (1/2”) box spanner, avoiding too
much strenght while thightening the nut, which could
damage the leveling feet adjusting system.
>From the back of the unit and by means of a suit-
able, high duty hand trolley, take o the appliance and
place it on the floor.
Be very careful to avoid any damage to floors. Delicate
floors should be protected with plywood, hard card-
board or similar material panels.
3. PREPARING THE INSTALLATION
3.2 Electrical and Water connection
The Built-in Fhiaba filter cannot make it
safe to drink any water which is not suit-
able for human consumption.
The appliance should be connected only
to a drinkable water supply system.
Do not use extension cords or adapters.
Once the appliance is fully installed, con-
nected to the water supply (if applicable)
and operational, in the event that the wa-
ter supply must be turned off,(touch the
button on control panel to switch it off)
before the main water is shut off to pre-
vent the appliance from entering a ‘NO
WATER IN’ alarm state.
The appliances are delivered from the factory for op-
eration at 110V-120V AC - 60Hz (US and Canada).
They are provided with a suitable supply cable and
plug to be connected to an appropriate 15A socket
(US and Canada) provided with an eective grounding.
A circuit breaker should also be installed and should
be easily accessible so that it can be easily switched
o before performing any installation or maintenance.
To connect to the water supply system (for appliances
equipped with ice makers) a 1/4” waterline with ac-
cessible shut-o valve must be supplied.
The appliance is provided with a water adapter elbow
which is suitable for high water pressure and com-
plies the Food Regulations.
The water filter cartridge, which is provided with the
appliance, should be installed according to the ac-
companying instructions. Use only the new adapter
which is supplied with the appliance. The solenoid
connection on the appliance is 3/4” diameter but is
metric threaded. A standard garden hose threaded
connector such as a braided stainless hose found at
typical hardware stores will strip or damage the sole-
noid threads. Use only the supplied 1/4” quick connect
1
4
1
2
3
EW
E W
EW
E W

EN
13
EN
elbow adapter for connecting a 1/4” copper or poly-
ethylene source water line to the appliance.
Do not use extension cords and/or mul-
tiple adapters for the power supply con-
nection.
ELECTRICAL AND WATER SUPPLY
BEHIND THE UNIT
INTEGRATED
AND BRILLIANCE SERIES:
STANDPLUS AND X-PRO
SERIES:
3.3 Energy: Alternatives
and Home Automation
If energy is supplied through an alternative en-
ergy power source (solar, geothermal, etc..) or
if home automation systems are installed, it is
necessary to install the Alternative Energy Kit to
integrate the unit into the power grid.
INTEGRATED AND BRILLIANCE SERIES:
fig.1 Back of appliance
Operate as follows:
> Unwind the electric cable and connect it directly to
the wall socket.
> Make sure the appliance is in the Stand-by con-
dition and that all lights are o; should it be not so
press the Unit button to switch it o.
> Fit one end of the water hose onto the connector at
the appliance’s back [ 1 ] .
> Fit the other end of the hose to the water tap, use
the gaskets provided in the Owner’s Kit [ 2 ].
STANDPLUS AND X-PRO SERIES:
Operate as follows:
> Unwind the electric cable and connect it directly to
the wall socket.
> Make sure the appliance is in the Stand-by con-
dition and that all ights are o; should it be not so
press the Unit button to switch it o.
> Connect the water line to the threaded connection
at the base of the unit, as in figure [ 1 ].
fig.2 Back of appliance
fig.3 Front of appliance
Water connection
Electrical connection
Electrical connection
Water connection
E
W
E
W
1
1 2

14 www.fhiaba.com · [email protected]
3.4 Levelling
Adjust the appliance level by means of the front
levelling feet and the rear adjustable wheels.
Operate as follows:
> After removing the bottom plinth or grille (it is
kept in position by magnets), adjust the height of
the levelling feet [ 1 ] by means of a 17 mm (3/4”)
open spanner.
> Then adjust the height of the rear wheels by
turning the front adjusting bolts [ 2 ] clockwise or
anticlockwise as it may be required.
> Remount the bottom plinth or grille.
4.1 Niche Dimensions and Installation
Styles: Integrated Series
A - KCLITU: Lateral connection Kit
(not included - must be ordered as a separate
accessory)
B - KCCITU: Central connection Kit
(not included - must be ordered as a separate
accessory)
FI36
FI30
FI24
897 (35 1/4”)900 (35 1/2”)
750 (29 5/8”)
600 (23 3/4”)
747 (29 3/8”)
597 (23 1/2”)
Panels WidthNiche
Series
> Fit the other end of the hose to the water tap, use
the gaskets provided in the Owner’s Kit [ 2 ].
Firmly tighten with fingers - a tool / wrench should
not be needed to
make a proper seal. Turn on the water and ensure all
connections are not leaking prior to pushing the unit
into the niche.
4. NICHE DIMENSIONS
1
2
1
2
FI24: 600 (23 ¾”)
FI30: 750 (29 ⅝”)
FI36: 900 (35 ½”)
CCB
2

EN
15
EN
4.2 Niche Dimensions and Installation
Styles: StandPlus and X-Pro Series
Stand-Proud
KCLXB: Lateral connection Kit
(not included - must be ordered as a separate ac-
cessory)
4.3 Flush installation with standard
aluminum trims
4.4 Prominent installation with standard
aluminum trims
A - KCLITU: Lateral connection Kit
(not included - must be ordered as a separate
accessory)
B - KCCITU: Central connection Kit
(not included - must be ordered as a separate
accessory)
A
B
6,5 (¼”)
A
B
6,5 (¼”)
10 (3⁄8”)
A - KCLITU: Lateral connection Kit
(not included - must be ordered as a separate
accessory)
B - KCCITU: Central connection Kit
(not included - must be ordered as a separate
accessory)
900 (35 1/2”)
750 (29 5/8”)
600 (23 3/4”)
914 (36”
)
762
(30”)
610 (24”)
36
30
24
MAXMIN
Series
NICHE
24: 610 (24”)
30: 762 (30”)
36: 914 (36”)

16 www.fhiaba.com · [email protected]
INTEGRATED SERIES
5.1 Decorative door and bottom-drawer
panels layout
The dimensions of the panels are indicated in the
table and drawings on next pages.
Nevertheless, according to the requirements for
aligning with other kitchen structures, the door
panel can be higher than the upper edge of the
refrigerator door, and the drawer panel can be
lower than the edge of the drawer.
The panels must be mounted using special bra-
ces which attach to adjustable devices provided
on the door and drawer and with brackets that
anchor and adjust the panel’s vertical direction.
Braces, brackets and fixing screws are provided
with the appliance and must be applied to the pa-
nel as indicated.
Operate as follows:
To prepare the panels to be mounted on the ap-
pliance, follow these steps, working on the back
of the panel.
Door Panel
> Trace, a line dividing the panel width in half [ 1 ].
> Starting form the Bottom edge of the panel,
mark the positioning of the brackets [ 2 ].
5. PANELS MOUNTING
4.5 Stand-Proud (for StandPlus and
X-Pro series)
Niche 610 mm (24”)
KCLXB: Lateral connection Kit
(not included - must be ordered as a separate
accessory)
25 (1”)
20 (
¾”
)
15 (
5⁄8”
)
10 (
3⁄8”
)
610 (24”)
2
1

EN
17
EN
> Following the corresponding table, mark the
external and then the internal hole [ 3 ].
> Position the brackets on each set of marks to
make sure they are aligned [ 4 ], then drill holes
through the panel (pay close attention to the pa-
nel’s thickness) [ 5 ].
> Screw the brackets in place [ 6 ].
Drawer Panel
> When preparing the Drawer Panel, follow the
same instructions as per the door panel, but
make sure measurements are taken starting
from the top edge [ 7 ].
The support bracket faces the opposite way [ 8 ]
(note imgs 4 and 8).
8
7
65
4
3

18 www.fhiaba.com · [email protected]
5.2 Decorative panels layout for Fridge
with one Bottom-Drawer
SERIES 899 / 36” SERIES 749 / 30” SERIES 599 / 24”
HINGE LEFT HINGE RIGHT HINGE LEFT HINGE RIGHT HINGE LEFT HINGE RIGHT
A897 (35 1/4”) 897 (35 1/4”) 747 (29 3/8”) 747 (29 3/8”) 597 (23 1/2”) 597 (23 1/2”)
B355,5 (14”) 261 (10 1/4”) 279 (11”) 187 (7 3/8”) 205 (8 1/8”) 111 (4 3/8”)
C261 (10 1/4”) 355,5 (14”) 187 (7 3/8”) 279 (11”) 111 (4 3/8”) 205 (8 1/8”)
D418 (16 1/2”) 386 (15 1/4”) 343 (13 1/2”) 311 (12 1/4”) 276,5 (10 7/8”) 236,5 (9 3/8”)
E386 (15 1/4”) 418 (16 1/2”) 311 (12 1/4”) 343 (13 1/2”) 236,5 (9 3/8”) 276,5 (10 7/8”)
F/G 354,5 (14”) 354,5 (14”) 279,5 (11”) 279,5 (11”) 203,5(8”) 203,5(8”)
Holes positions:
5. PANELS MOUNTING
D E
D E
A
B C
F G
13 (½”)
13 (½”)
34 (1 3⁄8”)
34 (1 3⁄8”)
1285 (50 5⁄8”)
1163 (45 ¾”)
660 (26”)
157 (6 ¼”)
min 1390 (54 ¾”)max 635 (25”)
507.5 (20”)
382 (15 1⁄8”)
100 (4”)

EN
19
EN
5.3 Decorative panels layout
for Fridge Brilliance
SERIES 899 / 36” SERIES 749 / 30”
HINGE LEFT HINGE RIGHT HINGE LEFT HINGE RIGHT
A897 (35 1/4”) 897 (35 1/4”) 747 (29 3/8”) 747 (29 3/8”)
B417 (16 3/8”) 417 (16 3/8”) 342 (13 1/2”) 342 (13 1/2”)
C354,5 (14”) 354,5 (14”) 279,5 (11”) 279,5 (11”)
Holes positions:
A
BB
A
BB
C C
13 (½”)
34 (1 3⁄8”)
6,5 (¼”) 6,5 (¼”)
34 (1 3⁄8”)
1273 (50 1⁄8”)
1163 (45 ¾”)
660 (26”)
157 (6 ¼”)
min 1390 (54 ¾”)max 635 (25”)
507.5 (20”)
382 (15 1⁄8”)
100 (4”)

20 www.fhiaba.com · [email protected]
5.4 Decorative panels layout
for Fridge with two Bottom-Drawers
SERIES 899 / 36” SERIES 749 / 30”
HINGE LEFT HINGE RIGHT HINGE LEFT HINGE RIGHT
A897 (35 1/4”) 897 (35 1/4”) 747 (29 3/8”) 747 (29 3/8”)
B355,5 (14”) 261 (10 1/4”) 279 (11”) 187 (7 3/8”)
C261 (10 1/4”) 355,5 (14”) 187 (7 3/8”) 279 (11”)
D418 (16 1/2”) 386 (15 1/4”) 343 (13 1/2”) 311 (12 1/4”)
E386 (15 1/4”) 418 (16 1/2”) 311 (12 1/4”) 343 (13 1/2”)
F/G 354,5 (14”) 354,5 (14”) 279,5 (11”) 279,5 (11”)
Holes positions:
5. PANELS MOUNTING
D E
A
BC
F G
D E
min 1265 (49 ¾”)
1160 (45 5⁄8”)
1044 (41 1⁄8”)
600 (23 5⁄8”)
268 (10 ½”)
292,5 (11 ½”)
183 (7 ¼”)
73 (2 7⁄8”)66 (2 5⁄8”) 157 (6 ¼”)
337 (13 ¼”)max 415 (16 3⁄8”)
13 (½”)
13 (½”)
34 (1 3⁄8”)
Other manuals for Integrated Series
3
This manual suits for next models
4
Table of contents
Languages:
Other Fhiaba Wine Cooler manuals

Fhiaba
Fhiaba 1T User manual

Fhiaba
Fhiaba GranMaestro Series Assembly instructions

Fhiaba
Fhiaba KS5990TWT User manual

Fhiaba
Fhiaba XS8991TWT6 User manual

Fhiaba
Fhiaba FP24BWRLGS User manual

Fhiaba
Fhiaba TriMode User manual

Fhiaba
Fhiaba StandPlus Series User manual

Fhiaba
Fhiaba XS8990TWT3 User manual

Fhiaba
Fhiaba Premium Series Assembly instructions

Fhiaba
Fhiaba 1T User manual