SubDrive75, SubDrive100, SubDrive150, MonoDrive & MonoDriveXT
Power Supply
From Circuit Breaker
BLACK
RED
RED
YEL BLK
(BRN)
E4
(BLU)
GND
(OUTPUT)
E3
RV2
E5
E1
E2
E6
TO
L1 L2
(INPUT)
RED
YEL
INPUT
FILTER
TO
OUTPUT
FILTER
RV1
BLK
225505101 REVB GND
J2
J1
RV4
RV3
RV8
RV9
RV10
PRESSURE
SENSOR
SENSOR
213
3FAN
SW2
PRESSURE
SW1 2
4
14
R1
ADJUST
From Power Source
J1
L1 L2
(Input)
Output to Motor
Red Yel Blk
(Brn) (Blue) (Blk)
(Output)
J2
Feed the motor leads through
the large enclosure opening and
securely attach to the terminals
matching the lead colors to the
colors shown.
Feed the pressure sensor wires
through the small enclosure opening
and securely attach to the sensor
terminals.
Feed the 230 V power leads through
the large enclosure opening and
securely attach to the terminals
marked L1, GND and L2.
1 2 3 4
O
N
1 2 3 4
O
N
1 2 3 4
O
N
Configuration Switch SW1
See chart below for appropriate controller
setting. Reference the SubDrive/MonoDrive
Installation Manual or access cover for
more information.
BlkRed
Sensor Connection
PRESSURE
SENSOR
MonoDrive MonoDriveXT SubDrive75 SubDrive100 SubDrive150
1/2 hp (motor) 1.5 hp (motor)* 3/4 hp (pump)* 1 hp (pump)* 1.5 hp (pump)*
Power Supply
From Circuit Breaker
YEL BLK
(BRN) (BLU)
(OUTPUT)
L1 L2
(INPUT)
RED
PRESSURE
SENSOR
From Power Source
J1
L1 L2
(Input)
Output to Motor
Red Yel Blk
(Brn) (Blue) (Blk)
(Output)
J2
Feed the motor leads through
the large enclosure opening and
securely attach to the terminals
matching the lead colors to the
colors shown.
Feed the pressure sensor wires
through the small enclosure opening
and securely attach to the sensor
terminals.
Feed the 230 V power leads through
the large enclosure opening and
securely attach to the terminals
marked L1, GND and L2.
1 2 3 4
O
N
1 2 3 4
O
N
1 2 3 4
O
N
Configuration Switch SW1
See chart below for appropriate controller
setting. Reference the SubDrive/MonoDrive
Installation Manual or access cover for
more information.
BlkRed
Sensor Connection
PRESSURE
SENSOR
#3 Switch
Underload sensitivity selection
OFF Position - Normal(default) ON Position - Low
See SubDrive/MonoDrive Installation Manual for more information.
#4 Switch
Steady Flow - Control selection
OFF Position - Standard(default) ON Position - Steady Flow
See SubDrive/MonoDrive Installation Manual for more information.
SubDrive75, SubDrive100, SubDrive150, MonoDrive & MonoDriveXT
MonoDrive MonoDriveXT SubDrive75 SubDrive100 SubDrive150
3/4 hp (motor)* N/A 1 hp (pump) 1.5 hp (pump) 2 hp (pump)
MonoDrive MonoDriveXT SubDrive75 SubDrive100 SubDrive150
1 hp (motor) 2 hp (motor) 1.5 hp (pump) 2 hp (pump) 3 hp (pump)
Configuration Switch SW1
Wiring/Configuration-NEMA 4
To operate a different pump size, a Configuration Switch (SW1) must be positioned to select the correct pump rating.
Reference the chart below for appropriate Configuration Switch setting.
*(default)