Introduction
Thank you for choosing S5850-24XMG switch. This guide is designed to familiarize you with the layout
of the switch and describes how to deploy the switch in your network.
S5850-24XMG
SYS ID MGMT
CON
MGMT
S5850-24XMG
21
43
65 87
10
9
12
11
14
13 16
15
18
17
20
19
22
21 24
23
123
26 100G
25
4Breakout
Accessories
Grounding Cable x1
Console Cable x1
M4 Screw x12Front Mounting Bracket x2
Power Cord x2
Back Mounting Bracket x2
Sliding Rail x2

EN
2
Hardware Overview
Front Panel Ports
Ports Description
CON
MGMT
USB
RJ45
An RJ45 console port for serial management
An Ethernet management port
A USB port for software and conguration backup and
oine software upgrade
10/100/1000/2.5G/5G/10GBASE-T ports for Ethernet connection
QSFP28 QSFP28 ports for 40/100G transceivers
RJ45
SYS ID MGMT
CON
MGMT
S5850-24XMG
21
43
65 87
10
9
12
11
14
13 16
15
18
17
20
19
22
21 24
23
123
26 100G
25
4Breakout
CON
MGMT
USB
QSFP28
Front Panel LEDs
SYS ID MGMT
CON
MGMT
S5850-24XMG
21
43
65 87
10
9
12
11
14
13 16
15
18
17
20
19
22
21 24
23
123
26 100G
25
4Breakout
SYS
MGMT
ID
RJ45
QSFP28
O
Blue
Amber
O
Green
LEDs State Description
ID indication function enable.
ID
SYS
MGMT
ID indication function disable.
System is running normally.
System occurs alarm or error.
No power or no system runs or runs abnormally.
Port is receiving or transmitting packets.
Port is linked.
Green
Blinking Green
O Port is not linked.

3
EN
Blinking(L)
On(L)
Amber(R)
Green(R)
Green
LEDs State Description
Port is linked.
RJ45
QSFP28
Port is receiving or transmitting packets.
Port is not linked.
The rate hasn’t reached the maximum.
The rate has reached the maximum.
O(R) Port is not linked.
Packets are receiving or transmitting at 40/100G.
Port is linked at 40/100G.
O(L)
Blinking Green
Amber
Blinking Amber
O
Port is linked at 10/25G.
Packets are receiving or transmitting at 10/25G.
Port is not linked.
Back Panel
4 Hot-swappable Fans 2 Hot-swappable Power Supplies
Grounding Point
Installation Requirements
Phillips screwdriver.
Before you begin the installation, make sure that you have the followings:
Standard-sized, 19" wide rack with a minimum of 1U height available.
Category 5e or higher RJ-45 Ethernet cables for connecting network devices.

EN
4
Site Environment
Do not install the equipment in a dusty environment.
The installation site must be free from leaking or dripping water, heavy dew, and humidity.
Do not operate it in an area that exceeds an ambient temperature of 45°C.
The installation site must be well ventilated. Ensure that there is adequate air ow around the
switch.
Be sure that the switch is level and stable to avoid any hazardous conditions.
Mounting the switch
Desk Mounting
1. Attach four rubber pads to the bottom.
2. Place the chassis on a desk.
SYS ID MGMT
CON
MGMT
S5850-24XMG
21
43
65 87
10
9
12
11
14
13 16
15
18
17
20
19
22
21 24
23
123
26
100G
25
4Breakout
SYS ID MGMT
CON
MGMT
S5850-24XMG
21
43
65 87
10
9
12
11
14
13

5
EN
Rack Mounting
1. Fix front mounting brackets and silding rails to the two sides of the switch with screws.
2. Push back mounting brackets onto the silding rails.
18
17
20
19
22
21 24
23
123
26 100G
25
4Breakout
SYS ID MGMT
CON
MGMT
S5850-24XMG
21
43
65 87
10
9
12
11
14
13 16
15
18
17
20
19
22
21 24
23
123
26 100G
25
4Breakout

EN
6
3. Attach the switch to the rack with screws and cage nuts.
Grounding the Switch
CAUTION: The earth connection must not be removed unless all supply connections have
been disconnected.
1. Connect one end of the grounding cable to a proper earth ground, such as the rack in which the
switch is mounted.
2. Secure the grounding lug to the grounding point on the back panel of the switch with the washer
and screws.

7
EN
Connecting the Power
1. Plug the AC power cord into the power port on the back of the switch.
2. Connect the other end of the power cord to an AC power source.
Connecting the RJ45 Ports
1. Connect an Ethernet cable to the RJ45 port of a computer, printer, network storage, or other
network devices.
2. Connect the other end of the Ethernet cable to the RJ45 port of the switch.
WARNING: Do not install power cable while the power is on.
10
9
12
11
14
13 16
15
18
17
20
19
22
21 24
23
123
26 100G
25
4Breakout
SYS ID MGMT
CON
MGMT
S5850-24XMG
21
43
65 87

EN
8
10
12
11
14
13 16
15
18
17
20
19
22
21 24
23
123
26 100G
25
4Breakout
1. Plug the compatible QSFP+ transceiver into the QSFP28 port.
2. Connect a ber optic cable to the transceiver, then connect the other end of the cable to
another ber device.
3. Or directly connect DAC/AOC cable to the QSFP28 port.
Connecting the QSFP28 Ports
CAUTION: Laser beams will cause eye damage. Do not look into bores of optical modules
or optical bers without eye protection.

9
EN
Connecting the Console Port
1. Insert the RJ45 connector into the RJ45 console port on the switch.
2. Connect the DB9 female connector of the console cable to the serial port on the computer.
Connecting the MGMT Port
1. Connect one end of a standard RJ45 Ethernet cable to a computer.
2. Connect the other end of the cable to the MGMT port on the switch.
Connecting the Management Ports
SYS ID MGMT
CON
MGMT
S5850-24XMG
21
43
65 87
10
9
12
11
14
13 16
15
18
17
20
19
22
21 24
23
SYS ID MGMT
CON
MGMT
S5850-24XMG
21
43
65 87
10
9
12
11
14
13 16
15
18
17
20
19
22
21 24
23

EN
10
123
26
25
4Breakout
Conguring the Switch
Conguring the Switch Using the Web-based Interface
Step1: Connect the computer to the Management port of the switch using the network cable.
Step 2: Set the IP address of the computer to 192.168.1.x. ("x" is any number from 2 to 254.). Set the
subnet mask of the computer to 255.255.255.0.
Step 3: Open a browser, type http://192.168.1.1, and enter the default username and
password (admin/admin).
Step 4: Click sign in to display the web-based conguration page.
?x
OK Cancel
General
IP address:
Subnet mask:
Default gateway:
You can get IP settings assigned automatically if your network
supports this capability. Otherwise, you need to ask your network
administrator for the appropriate IP settings.
Internet Protocol Version 4(TCP/IPv4) Properties
Use the following IP address:
Obtain an IP address automatically
Preferred DNS server:
Alternate DNS server:
Validate settings upon exit Advanced...
. . . 21168192
0255
255255
. . .
. . .
. . .
. . .
Obtain DNS server address automatically
Use the following DNS server addresses:
3
26
4Breakout

EN
11
Conguring the Switch Using the Console Port
Step 1: Connect a computer to the console port of the switch with supplied console cable.
Step 2: Start the terminal simulation software such as HyperTerminal on the computer.
Step 3: Set the parameters of the HyperTerminal: 115200 bits per second, 8 data bits, no parity,
1 stop bit and no ow control.
Step 4: Enter the default username and password (admin/admin).
x
Quick Connect
Protocol: Serial
Flow Control
DTR/DSR
RTS/CTS
XON/XOFF
Save sessionShow quick connect on startup
Open in a tab
Connect Cancel
COM3
115200
8
None
1
Port:
Baud rate:
Data bits:
Parity:
Stop bits:
Name of pipe:

EN
12
Troubleshooting
Loading Failure
1. Check whether the port is properly connected. If some ports are not connected, then re-connect them
to ensure that connections are correct, and try to re-loading.
2. Check the loading process information displayed on the super terminal to verify whether there are
input errors. If there are input errors, correct them and re-load.
If system password is lost or forgotten, the following method can be used to reset the password:
1. Connect the console port of the switch to the computer through the console cable.
2. Press Ctrl + B to enter the Uboot mode.
3. Start the system with an empty conguration le with no password.
Bootrom#boot_ash_nopass
Bootrom#Do you want to revert to the default cong le?[Y|N|E]:
1. Make sure the power supply is normal and the console cable is properly connected.
2. Check whether the console cable is the right type.
3. Check whether the control cable driver is properly installed on the computer.
4. Ensure the parameters of the HyperTerminal are correct.
User Password Lost
Accessing the Web-based Conguration Page Unsuccessfully
NOTE: Forgetting your username and password and restoring them through console port
may cause conguration loss and business interruption. Please remember your username
and password.

EN
13
Online Resources
Download
Help Center
Contact Us
https://www.fs.com/products_support.html
https://www.fs.com/service/fs_support.html
https://www.fs.com/contact_us.html
Product Warranty
FS ensures our customers that if there are any damage or faulty items due to our workmanship, we
will oer a free return within 30 Days from the day you receive your goods. This excludes any custom
made items or tailored solutions.
Warranty: This product enjoys 5 years limited warranty against defect in materials or
workmanship. For more details about warranty, please check at
https://www.fs.com/policies/warranty.html
Return: If you want to return item(s), information on how to return can be found at
https://www.fs.com/policies/day_return_policy.html
5

S5850-24XMG
SYS ID MGMT
CON
MGMT
S5850-24XMG
21
43
65 87
10
9
12
11
14
13 16
15
18
17
20
19
22
21 24
23
123
26 100G
25
4Breakout
DE
14
Einführung
Vielen Dank, dass Sie sich für den S5850-24XMG Switch entschieden haben. Diese Anleitung soll Sie mit
dem Aufbau des Switches vertraut machen und erklärtt, wie Sie den Switch in Ihrem Netzwerk einsetzen.
Zubehör
Erdungskabel x1
Console-Kabel x1
M4-Schraube x12Montagehalterung für
die Vorderseite x2
Netzkabel x2
Montagehalterung für
die Rückseite x2
Gleitschiene x2

RJ45
SYS ID MGMT
CON
MGMT
S5850-24XMG
21
43
65 87
10
9
12
11
14
13 16
15
18
17
20
19
22
21 24
23
123
26 100G
25
4Breakout
CON
MGMT
USB
QSFP28
SYS ID MGMT
CON
MGMT
S5850-24XMG
21
43
65 87
10
9
12
11
14
13 16
15
18
17
20
19
22
21 24
23
123
26 100G
25
4Breakout
SYS
MGMT
ID
RJ45
QSFP28
DE
15
Hardware-Übersicht
Ports an der Vorderseite
Port Beschreibung
CON
MGMT
USB
RJ45
Ein RJ45-Console-Port für die serielle Verwaltung
Ein Ethernet-Verwaltungsport
Ein USB-Port für Software- und Kongurations-Backups und
Oine-Software-Upgrades
10/100/1000/2,5G/5G/10GBASE-T Ports für Ethernet-Verbindung
QSFP28 QSFP28-Ports für 40/100G-Transceiver
LEDs an der Vorderseite
Aus
Blau
Braun
Aus
Grün
LED Status Beschreibung
ID-Anzeigefunktion ist aktiviert.
ID
SYS
MGMT
ID-Anzeigefunktion ist deaktiviert.
Das System funktioniert normal.
Das System zeigt einen Alarm oder Fehler an.
Kein Strom, das System läuft nicht oder läuft fehlerhaft.
Der Port empfängt oder sendet Datenpakete.
Der Port ist verbunden.
Grün
Blinkt Grün
Aus Der Port ist nicht verbunden.

DE
16
Blinkt (L)
An (L)
Braun (R)
Grün (R)
Grün
LED Status Beschreibung
Der Port ist verbunden.
RJ45
QSFP28
Der Port empfängt oder sendet Datenpakete.
Der Port ist nicht verbunden.
Die Rate hat nicht den Höchstwert erreicht.
Die Rate hat den Höchstwert erreicht.
Aus (R) Der Port ist nicht verbunden.
Datenpakete werden mit 40/100G empfangen oder gesendet.
Der Port ist mit 40/100G verbunden.
Aus (L)
Blinkt Grün
Braun
Blinkt Braun
Aus
Der Port ist mit 10/25G verbunden.
Datenpakete werden mit 10/25G empfangen oder gesendet.
Der Port ist nicht verbunden.
Rückseite
4 Hot-swap-fähige Lüfter 2 Hot-Swap-fähige Stromversorgungen
Erdungspunkt
Installationsvoraussetzungen
Kreuzschlitzschraubendreher.
Bevor Sie mit der Installation beginnen, vergewissern Sie sich, dass Sie über
die folgenden Dinge verfügen:
Ein 19"-Rack in Standardgröße mit einer Mindesthöhe von 1 HE.
RJ-45-Ethernet-Kabel der Kategorie 5e oder höher für den Anschluss von Netzwerkgeräten.

SYS ID MGMT
CON
MGMT
S5850-24XMG
21
43
65 87
10
9
12
11
14
13 16
15
18
17
20
19
22
21 24
23
123
26
100G
25
4Breakout
SYS ID MGMT
CON
MGMT
S5850-24XMG
21
43
65 87
10
9
12
11
14
13
DE
17
Standortumgebung
Installieren Sie das Gerät nicht in einer staubigen Umgebung.
Der Installationsort muss frei von austretendem oder tropfendem Wasser, starkem Tau und
Feuchtigkeit sein.
Betreiben Sie das Gerät nicht in einem Bereich, in dem die Umgebungstemperatur 45°C übersteigt.
Der Installationsort muss gut belüftet sein. Stellen Sie sicher, dass um den Switch herum ein
ausreichender Luftstrom herrscht.
Achten Sie darauf, dass der Switch eben und stabil steht, um gefährliche Bedingungen zu vermeiden.
Montage des Switches
Montage auf einem Tisch
1. Bringen Sie vier Gummipads an der Unterseite an.
2. Stellen Sie das Gehäuse auf einen Tisch.

18
17
20
19
22
21 24
23
123
26 100G
25
4Breakout
SYS ID MGMT
CON
MGMT
S5850-24XMG
21
43
65 87
10
9
12
11
14
13 16
15
18
17
20
19
22
21 24
23
123
26 100G
25
4Breakout
DE
18
Rack-Montage
1. Befestigen Sie die Montagehalterungen für die Vorderseite und die Gleitschienen mit Schrauben an
den beiden Seiten des Switches.
2. Schieben Sie die Halterungen zurück auf die Gleitschienen.

SYS ID MGMT
CON
MGMT
S5850-24XMG
21
43
DE
19
3. Befestigen Sie den Switch mit Schrauben und Kägmuttern am Rack.
Erdung des Switches
ACHTUNG: Der Erdungsanschluss darf erst dann entfernt werden, wenn alle
Versorgungsanschlüsse getrennt wurden.
1. Schließen Sie ein Ende des Erdungskabels an eine geeignete Erdung an, z. B. an das Rack, in dem der
Switch montiert ist.
2. Befestigen Sie die Erdungslasche mit der Unterlegscheibe und den Schrauben am Erdungspunkt auf
der Rückseite des Switches.
Table of contents
Languages:
Other FS Switch manuals

FS
FS S5800-48MBQ User manual

FS
FS KVM-160217IP User manual

FS
FS PoE+ Series Operating instructions

FS
FS S5900-24S4T2Q User manual

FS
FS S1900-16TP User manual

FS
FS S3700-24T4F Instruction Manual

FS
FS S1150-8T2F User manual

FS
FS S5860-48SC Operating manual

FS
FS S3150-8T2FP User manual

FS
FS S5900-24S4T2Q Quick guide
Popular Switch manuals by other brands

ZyXEL Communications
ZyXEL Communications GS1915-8 quick start guide

Generac Power Systems
Generac Power Systems HTS owner's manual

Edge-Core
Edge-Core ECS4510-52P installation guide

Kathrein
Kathrein EXD 1524 manual

Versitron
Versitron S72450 installation guide

Ex-Tech
Ex-Tech XPEW Series operating instructions