Gasmate OPTIMUM EH633R Manual

1
• Metal radiant heater with non glowing element
• Adjustable wall and ceiling bracket
• Black anodised aluminium
• 1.5m long power cord
• Designed for indoor and outdoor use
• Ideal for use in alfresco areas, verandahs and garages
• EH633 + EH633R - requires 15A power point to be installed by qualified electrician
03455 05/16
Gasmate®is a registered trademark of: Sitro Group Australia Pty Ltd www.gasmate.com.au
Aber Holdings Ltd - N.Z www.gasmate.co.nz
OPTIMUM RADIANT HEATER
EH600 SERIES
Important: Retain these instructions for future use.
03240 07/16

3
2
INSTALLATION, OPERATION AND
MAINTENANCE INSTRUCTIONS
Safety
Before attempting to operate this heater, the following
basic safety precautions should be taken to reduce
the risk of re, electric shock and personal injury. It
is important to read the instruction manual and to
understand its’ applications, limitations and potential
hazards associated with this heater. This heater is not
intended for use by persons (including children) with
reduced physical, sensory or mental capabilities, or lack
of experience and knowledge, unless they have been
given supervision or instruction concerning the use of
the appliance by a person responsible for their safety.
This heater is not designed for use within 1m or above
a water source. It is important that you read, understand
and follow these instructions very carefully. They are
designed for the safety of yourself and others ensuring a
long and trouble free service life from your heater. This
electric heater complies with Australian and International
standards and safety requirements. Repairs should only
be carried out by qualied persons using original spare
parts. Failure to do so may result in considerable danger
to the operator.
Safe Operation
Beware of Children and Pets
Children should not be allowed to touch or operate
heaters or touch extension cords, if used. All heaters
should be kept out of reach of children, preferably stored
or locked in a secure cabinet or room when not in use.
Do Not Abuse the Power Cord
Never yank or pull on the power cord to disconnect it from
the mains supply socket. Never carry your heater by its’
power cord. Keep the power cord away from heat, oil,
solvents and sharp edges. Check the power cord regularly
for any damage and if the power cord becomes damaged
have it replaced by an authorised service facility.
Extension Cords and Reels
This heater is NOT designed to run off an extension cord.
If you require an additional power point please have one
installed by a qualied electrician.
The use of extension cords may cause power voltage loss
which will result in damage to the appliance this will NOT
be covered under warranty.
Installation
Always ensure you select the correct xing accessories
which suit the particular wall/ceiling material you are
attaching to, if in doubt please discuss with your local
retailer or local hardware store. This heater is not
designed for use within 1m or above a water source.
All installations must meet the requirements of Australia
Standard
AS/NZS 3000:2007.
Ensure that the heater is not positioned directly above,
below or in front of a power point or switch.
This heater is not designed to be used with 3rd party timer
or programmable system.
FOR YOUR SAFETY
WARNING: Fire risk exists if this heater is covered by
or positioned close to curtains or other combustible
materials.
NOTE: If using this heater outside ensure that it is
connected directly to an outdoor power point.
The electrical system of this heater must be
connected with an automatic 30mA circuit breaker
and/or residual current device (RCD). If uncertain
have a qualied electrician check your electrical
system before installation and/or use.
All electrical connections are made in a dry area.
Outdoor power points must be weatherproof and
installed by a qualied electrician.
Sitro Group Australia Pty Ltd is not responsible for
incorrectly chosen xing accessories or any damage
which may be caused by an incorrectly tted wall
heater.
If required 15AMP power points must be installed by
a qualied electrician.
For any queries or assistance call
Customer Service
Australia Only
1300 174 876
Hours of operation:
Monday to Friday 8.30am - 5.30pm EST
Do not return to place of purchase.
Keep your purchase receipt, this will be required to
make any claims under the 12 month warranty.

3
2
Specific Safety Instructions
WARNINGS
Do not use the heater in areas where there is a
risk of explosion or re from ammable gases.
Ensure that the heating area is kept clear of combustible
materials. Do not use the heater in damp areas, without
suitable ventilation. This heater is not designed for use
within 1m or above a water source. Do not place within
one metre (1m) of any water source. Do not place
directly in front of, below or above any power points or
switches.
Fire risk exists if this heater is covered by or
positioned close to curtains or other combustible
materials.
• This heater is intended for domestic/
household use only.
• Always ensure that this heater is installed as per
the requirements noted in Australian Standard
AS/NZS 3000:2007.
• Always keep heater at least one metre (1m)
from combustible materials.
• DO NOT locate this heater directly below,
above or in front of the power supply socket
or switch.
• DO NOT use this heater within 1 metre
or above any water source.
• DO NOT use this heater in either the
bathroom or ensuite without suitable
ventilation.
• DO NOT use a 3rd party timer, or
programmable system with this heater.
• DO NOT clean the heater while the heater is
on or plugged into the mains power supply.
• DO NOT touch any part of the heater while
on, hot surfaces may burn.
• DO NOT use the wall heater as a dryer.
• DO NOT attempt to modify the heater,
power cord, power plug or the supplied
accessories in any way.
• DO NOT expose the heater to rain, water, or
use in damp wet conditions.
• NEVER cover this heater.
• NEVER carry the heater by its power supply cord.
• NEVER use with the power cord coiled,
bundled up or tied up. Always extend fully
before use.
• NEVER use the heater if any part of it is
damaged.
• Ensure that the heater is disconnected from
the mains supply when installing, cleaning
or removing/installing.
• Ensure this heater is not left on when
unattended.
• Ensure the heater is not used in areas
where ammable gases are present, e.g.
paint, petrol etc.
• Always turn the heater OFF at the unit
switch and the power point switch when not
in use for extended periods of time.
• Always allow the heater to cool, about one
(1) hour after the heater has been turned
off, before cleaning the heater.
• Always ensure that the power cord is fully
extended and NOT in contact with any part
of the heater.
• Always ensure that the heater is kept clean
and free from dust.
• Only use this heater when securely attached
to the wall/ceiling.

5
4
Electrical Data
IMPORTANT
This product is tted with a sealed electrical connection plug that is compatible with the heater, the mains supply for
Australia and meets the requirements of international standards. This heater must be connected to a supply voltage
that is equal to that stated on the rating label. If the mains connection plug or power cord becomes damaged it must be
replaced with a complete assembly that is identical to the original, and this must be replaced by an authorised service
centre. Always follow the Australian requirements for connection to the mains supply. If in doubt always consult a
qualied electrician.
Note: EH633 + EH633R (3200W) requires installation of a 15AMP socket by a qualied electrician before use.
Technical Specication
MODEL EH613/EH613R/B EH623/EH623R/B EH633/EH633R/B
Remote Control No / Yes No / Yes No / Yes
Voltage 220-240V AC ~ 50Hz 220-240V AC ~ 50Hz 220-240V AC ~ 50Hz
Input Wattage 1800W 2400W 3200W (15AMP)
Unit Weight 6.8Kg/7.5Kg 7.5Kg/8.2Kg 9.0Kg/9.7Kg
IP Rating IPx4 IPx4 IPx4
Heater specications can be found on the data label. B = BLACK COLOUR
Assembly
HEATER HEAD
Attach the heater rear bracket (B) to the heater body (A) using bolts, washers and nuts. You can either mount side or
lengthways depending on the mounting surface.
Mounting Bolts
Mounting Nuts
and Washers
Mounting Bolts To adjust mounting bolts,
remove nut and slide
mounting bolts between units
mounting bolt groove then
fit bracket, replace nut and
tighten.
(B) Heater Rear
Bracket
(B) Heater Rear
Bracket
(A) Heater Body

5
4
Mounting Heater
General Mounting Suggestions
If unsure please discuss with your local hardware store.
• Ensure the xing screws are at least suitable for 10Kg each.
• If tting to a stud wall or ceiling ensure all xing screws are into timber. Plasterboard IS NOT
suitable by itself.
• If no timber stud/joists are available we would suggest installing a timber batten to attach to.
Wall/Ceiling Bracket Assembly
1. The bottom of the heater body should be 1.8m above the oor, see page 6.
2. Do not position the heater directly above or below a power point or switch.
Do not position heater in front of a power point.
3. Mark and drill 2 mounting holes for bracket (C).
4. Using 2 suitable screws (not supplied) attach the bracket to the wall or ceiling.
Note: If unsure what screws to use please discuss with your local hardware store.
5. Using the nuts and bolts join the bracket (C) to the heater bracket (B) and tighten fully.
6. Heater is now mounted and ready for use. Check the safety distance between the
heater body and ammable surface when wall or corner mounted (see page 6). Do not
mount the heater in the ceiling, always mount to the ceiling (see page 6).
(C) Ceiling/Wall
Brackets
(C) Ceiling/Wall
Brackets
(A) Heater Body
Heater ON/OFF
Switch
Locking Bolt
Locking Nut and Washer
Head Tilt Bolt
Head Tilt Nut and Washer
NOTE: To adjust bracket position, see bottom page 4
This manual suits for next models
9
Table of contents
Other Gasmate Electric Heater manuals

Gasmate
Gasmate EH325 User manual

Gasmate
Gasmate GM135-010 User manual

Gasmate
Gasmate EH714 User manual

Gasmate
Gasmate HELLION GM135-042 User manual

Gasmate
Gasmate Radion GM135-040 User manual

Gasmate
Gasmate GM135-008 User manual

Gasmate
Gasmate GM135-045 User manual

Gasmate
Gasmate EH431 User manual

Gasmate
Gasmate GM135-044 User manual

Gasmate
Gasmate HELLION GM135-041 User manual