GE WIU-4 User manual

GE
Security
U.S.
T 888 GE SECURITY (1 888 437 3287)
F 561 998 6224
Asia
T 852 2907 8108
F 852 2142 5063
Australia
T 61 3 9259 4700
F 61 3 9259 4799
Europe
T 32 2 725 11 20
F 32 2 721 86-13
Latin America
T 305 593 4301
F 305 267 4300
www.gesecurity.com
©2005 General Electric Company
All Rights Reserved.
460487001F/11-05
Wiegand Interface Unit Four-State (WIU-4)
Installation Manual

Copyright Copyright © 2005, GE Security Inc. All rights reserved.
This document may not be copied or otherwise reproduced, in whole or in part,
except as specifically permitted under US and international copyright law,
without the prior written consent from GE.
Document number/460487001F (November 2005).
Disclaimer THE INFORMATION IN THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT
NOTICE. GE ASSUMES NO RESPONSIBILITY FOR INACCURACIES OR OMISSIONS
AND SPECIFICALLY DISCLAIMS ANY LIABILITIES, LOSSES, OR RISKS, PERSONAL OR
OTHERWISE, INCURRED AS A CONSEQUENCE, DIRECTLY OR INDIRECTLY, OF THE
USE OR APPLICATION OF ANY OF THE CONTENTS OF THIS DOCUMENT. FOR THE
LATEST DOCUMENTATION, CONTACT YOUR LOCAL SUPPLIER OR VISIT US ONLINE
AT WWW.GESECURITY.COM.
This publication may contain examples of screen captures and reports used in
daily operations. Examples may include fictitious names of individuals and
companies. Any similarity to names and addresses of actual businesses or
persons is entirely coincidental.
Trademarks
and patents
GE and the GE monogram are registered trademarks of General Electric.
Wiegand Interface Unit-Four State (WIU-4) product and logo are trademarks of
GE Security.
Other trade names used in this document may be trademarks or registered
trademarks of the manufacturers or vendors of the respective products.
Intended use Use this product only for the purpose it was designed for; refer to the data sheet
and user documentation. For the latest product information, contact your local
supplier or visit us online at www.gesecurity.com.
FCC
compliance
This equipment has been tested and found to comply with the limits for a
Class A digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference when
the equipment is operated in a commercial environment. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the instruction manual, may cause harmful inter-
ference to radio communications.
You are cautioned that any changes or modifications not expressly approved
by the party responsible for compliance could void the user's authority to
operate the equipment.
Regulatory

i
Contents
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Safety. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Radio interference. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Electrostatic discharge (ESD) precaution . . . . . . . . . . . . . . . . . . . . . . . . .2
Product features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
System requirements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Technical specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Parts list . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Installation overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Mounting the WIU-4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Configuring the WIU-4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
J3: Door and REX switch connector. . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
J4: Door and REX supervision connector . . . . . . . . . . . . . . . . . . . . . . . .10
J5: Reserved . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
J6: Reader interface connector. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
J7: Reserved . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
J8: Micro interface connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
J9: Reserved . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
J10: Door strike relay connectors. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
LED indicators. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
Connecting the WIU-4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Wiring diagrams. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
Testing the WIU-4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
Troubleshooting the WIU-4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Regulatory approvals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
UL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
CE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21

Wiegand Interfact Unit Four State (WIU-4)
Installation Manual
ii
Figures
Figure 1. Mounting instructions .................................................................. 7
Figure 2. WIU-4 connectors and jumpers.............................................. 9
Figure 3. Sample WIU-4 configuration..................................................14
Figure 4. WIU-4 to Micro/5 8RP board...................................................15
Figure 5. WIU-4 to Micro/PX-2000, PXN-2000, or
M2000PXNplus interface ..........................................................16

Introduction 1
Introduction
The Wiegand Interface Unit-Four State (WIU-4) board features a
Wiegand to F/2F data converter, which can accommodate both
conventional and proprietary Wiegand reader protocols, and
includes an 8 Amp relay for door strike control (entrance/exit)
activity. It provides the communications interface that enables
support of up to 16 Wiegand-output readers.
When combined with most conventional Proximity, Mifare®, and
ISO-15693 Wiegand-output readers, the WIU-4 reports
immediate alarm notification of short circuit, cut line, open
circuit, or closed circuit conditions to the GE access control
system.

Wiegand Interface Unit Four State (WIU-4)
Installation Manual
2
Safety
Radio interference
Electrostatic discharge (ESD) precaution
WARNING: This is an FCC Class A product. In a domestic
environment, this product may cause radio
interference, in which case, the user may be
required to take adequate measures.
WARNING: Circuit board components are vulnerable to damage
by electrostatic discharge (ESD). ESD can cause
immediate or subtle damage to sensitive electronic
parts. An electrostatic charge can build up on the
human body and then discharge when you touch a
board. A discharge can be produced when walking
across a carpet and touching a board, for example.
Before handling any board, make sure you dissipate
your body’s charge by touching ground. This
discharges any static electricity build-up.

Product features 3
Product features
The WIU-4 provides the following:
• Conversion of multiple Wiegand formats into GE
supervised F/2F format.
• Junction box capabilities with removable connectors for
ease of wiring.
• Built-in door strike relay with surge protecting diodes.
• Red LED, green LED, and beeper control outputs.
• Supports reader tamper and external tamper inputs.
• Self-resetting fuse protection on all power and signal
outputs.
• Options for supervised or unsupervised Door DI and
request-to-exit (REX) DI inputs.
• Built-in surge protection circuitry for data lines.
• Four built-in LEDs to help with installation and
troubleshooting.
• Supports Wiegand formats up to 64 bits.
• Supports most 8 bit keypad reader output formats.
Note: Do not use the WIU-4 with a 2SRP supervised reader processor
board/microcontroller configuration.

Wiegand Interface Unit Four State (WIU-4)
Installation Manual
4
System requirements
For UL compliant installation notes, refer to “UL Listed Installations” on
page 20.
Host software • Secure Perfect®Edition 3.0 or later
•PicturePerfect
™1.7 or later
Microcontrollers • Micro/5-PX with 2RP or 8RP
•Micro/5-PXNwith2RPor8RP
•M5PXNplus
• Micro/PX-2000
• Micro/PXN-2000
• M2000PXNplus
• M3000PXNplus
Reader support • Wiegand data output up to 64 bits
• Most 8 bit keypad readeroutput formats
Wiegand data
formats
•26-bit
•32-bit
• 35-bit Corporate 1000
•37-bit
• 40-bit GE formats
• Custom Wiegand formats up to 64 bits

Technical specifications 5
Technical specifications
For UL compliant installation notes, refer to “UL” on page 20.
Operating temperature
range
-31 F (-35 C) to +150 F (+66 C)
Relative humidity 5% to 95% (non-condensing)
Physical dimensions
(HxWxD)
3.1" (78.74 mm) x 2.5" (63.50 mm) x 0.644"
(16.35 mm)
Index of protection IP00
Input voltage range 9 to 16 VDC
Power consumption 40 mA @ 12 VDC (no reader attached)
Cable specifications*
* GE recommends using shielded cable for all installations.
Belden 8725 or equivalent, 20 AWG minimum
Maximum cabling distance
WIU-4 to micro:**
WIU-4 to reader:***
** WIU-4 to micro: The maximum cabling distance of 1,000 ft (304.8 meters) is
influenced by wire gauge, reader power requirements, and the 12 VDC level from
the microcontroller.
*** WIU-4 to reader: The maximum cabling distance of 250 ft (76.20 meters) is
influenced by wire gauge, reader power requirements, minimum input voltage at
the reader when using the 12 VDC from the WIU-4 (originally from the micro), and
the cabling between the WIU-4 and micro.
1000 ft (304.8 m) @ 12 VDC with 20 AWG cable
250 ft (76.2 m) @ 12 VDC with 20 AWG cable
Door strike relay****
**** The life of the relay decreases as the current switched by the contacts is
increased. Use low current door strikes for high traffic doors to maximize the
relay life. Use an external relay for high current applications.
8.0 A @ 30 VDC maximum
Agency approvals FCC Class A part 15
CE
UL 294

Wiegand Interface Unit Four State (WIU-4)
Installation Manual
6
Parts list
•WIU-4
• Mounting hardware kit
• Installation manual
Refer to the GE product catalog for part numbers and ordering
information.
Installation overview
The following is the general sequence of steps to follow when
installing the Wiegand Interface Unit-4. Each step is explained in
further detail in the sections that follow:
1. Mount the WIU-4.
Refer to “Mounting the WIU-4” on page 7.
Note: The WIU-4 must be mounted indoors, in a protective enclosure or
standard 2-gang electrical box (Installer supplied) as shown in
Figure 1.
2. Configure the WIU-4.
Refer to “Configuring the WIU-4” on page 8.
3. Connect the WIU-4.
Refer to “Connecting the WIU-4” on page 14.
4. Test the WIU-4.
Refer to “Testing the WIU-4” on page 17.

Mounting the WIU-4 7
Mounting the WIU-4
Figure 1. Mounting instructions
1. To mount the WIU-4 board in the 2 gang electrical box,
remove the electrical box cover and clean it with the
alcohol wipes provided in the mounting hardware kit.
2. Apply the four standoffs, provided in the mounting
hardware kit, to the four corners of the WIU-4 board, as
shown in Figure 1.
3. Remove the adhesive liner on the standoffs and attach the
WIU-4 board to the electrical box cover, making sure the
WIU-4 board does not interfere with or touch the sides of
the electrical box.

Wiegand Interface Unit Four State (WIU-4)
Installation Manual
8
Configuring the WIU-4
The WIU-4 has the following connectors and jumpers:
•J3: Door and REX switch connector
•J4: Four state door supervision jumper (Enabled)
•J5: Reserved. (A jumper must be installed on pins 1
and 2)
•J6: Reader interface connector
•J7: Reserved
•J8: Micro interface connector
•J9: Reserved
•J10: Door strike relay connector

Configuring the WIU-4 9
Figure 2. WIU-4 connectors and jumpers

Wiegand Interface Unit Four State (WIU-4)
Installation Manual
10
J3: Door and REX switch connector
The 6-pin connector, J3, is the door and REX switch interface.
If the door or REX switch is set up as supervised (1K resistor in
series with switch between high and return pins, 1K in parallel
with switch), the WIU-4 treats both the door and REX switch as
supervised and reports four states: cut line, short circuit, closed
circuit, and open circuit.
Note: To enable four-state supervision for the door and the REX, install a
jumper at position J4. Both points must be terminated with
resistors as shown in Figure 4 on page 15.
If supervision is required for only one (the door or the REX), then
also insert a 1K resistor across J3, pins 3 and 4 or pins 5 and 6, as
applicable.
If the door or REX is not set as supervised, the adapter reports
two states: open when there is no connection between the high
and return pins, or closed when a short exists between high and
return pins.
J4: Door and REX supervision connector
The 2-pin connector, J4, is the door and REX supervision
connector. By default, a jumper is installed on pins 1 and 2 to
enable 4-state supervision. Remove the jumper to disable 4-state
supervision and enable 2-state supervision.
Table 1. J3 Door and REX switch connector
PIN Description
1 Power 12 VDC fused power, 250 mA maximum
2 Ground
3 Door (high) 5 VDC output
4Door(return)0-5VDCinput
5 REX (high) 5 VDC output
6 REX (return) 0-5 VDC input

Configuring the WIU-4 11
J5: Reserved
The 3-pin connector, J5, is reserved. A jumper must be installed
across pins 1 and 2.
J6: Reader interface connector
The 10-pin connector, J6, is the reader interface connector.
If a tamper switch is desired, connect a single-pole, single-throw
(SPST), normally-closed pushbutton switch (installer supplied) to
connector J6, pins 8 and 9 on the WIU-4. When used with a
Micro/5-PX, Micro/5-PXN, M5PXNplus, Micro/PX-2000,
Micro/PXN-2000, M2000PXNplus, or M3000PXNplus, the
WIU-4 sends a supervised reader alarm message.
Table 2. J6 Reader interface connector
PIN Description
1*
* Use pin 1 or pin 10 for reader power, not both.
Power 12 VDC fused power to reader, 250 mA maximum
2 Ground
3 Wiegand DATA 0, normally at 5 VDC
4 Wiegand DATA 1, normally at 5 VDC
5 Green LED switches to ground during door unlock time
6 Red LED switches to ground to activate the red LED.
7 Signal switches to ground to activate the beeper
8**
** If the tamper feature is not used, a jumper must be installed across pins 8 and 9.
Tamper Select
0 VDC = no tamper
open = tamper
9** Tamper Common (ground output)
10* Power 5 VDC non-fused power to reader

Wiegand Interface Unit Four State (WIU-4)
Installation Manual
12
J7: Reserved
The 2-pin connector, J7, is reserved. A jumper is installed by
default across pins 1 and 2.
J8: Micro interface connector
The 4-pin connector, J8, is the Micro interface connector.
J9: Reserved
The 2-pin connector, J9, is reserved.
J10: Door strike relay connectors
The 5-pin connector, J10, is the door strike relay connection.
Table 3. J8 Micro interface connector
PIN Description
1 Power 12 VDC (power for WIU-4)
2 Ground
3DoorDO
4 Reader F/2F data
Table 4. J10 Door strike relay connector
PIN Description
1 Relay power (Source)
2 Relay power (Return)
3 Normally closed (NC) contact
4Notused
5 Normally open (NO) contact

Wiegand Interface Unit Four State (WIU-4)
Installation Manual
14
Connecting the WIU-4
Connect the WIU-4 between the GE microcontroller and access
control reader as indicated in Figure 3.
Figure 3. Sample WIU-4 configuration
WARNING: It is important to ensure all connections are
made prior to applying power.

Connecting the WIU-4 15
Wiring diagrams
Figure 4. WIU-4 to Micro/5 8RP board

Wiegand Interface Unit Four State (WIU-4)
Installation Manual
16
Figure 5. WIU-4 to Micro/PX-2000, PXN-2000, or M2000PXNplus interface
Table of contents
Other GE Control Unit manuals

GE
GE Intellix BMT 330 User manual

GE
GE Evolution Series E9000 User manual

GE
GE ARITECH ATS7300 User manual

GE
GE CR194 User manual

GE
GE SX TRANSISTOR CONTROL IC3645SR4U404N2 User manual

GE
GE VersaMax IC200ALG630 User manual

GE
GE WH18X28174 Configuration guide

GE
GE b30 User manual

GE
GE 10000 User manual

GE
GE ATS7310 Assembly instructions
Popular Control Unit manuals by other brands

Franke
Franke AQUA422 Installation and operating instructions

Mitsubishi Electric
Mitsubishi Electric A1S64TCTT-S1 user manual

jablotron
jablotron JA-114E quick start guide

Wiznet
Wiznet WIZ105SR user manual

SIATA
SIATA V260 Use and maintenance manual

PSA
PSA ELA Installation, operation and maintenance instructions