Contents
1. Specifications and Configuration....................................................................... 1
2. Installation Into Inverter ...................................................................................... 2
3. Parallel Data Input................................................................................................ 4
3-1. Connection and setting procedure.................................................................. 4
3-2. Data input mode selection and signal specifications....................................... 5
3-3. Signal logic and circuit format selection.......................................................... 7
4. Usage of PSO Terminal Function........................................................................ 8
Appendix Table 1 CN1 pin layout ............................................................................... 9
Appendix Table 2 TB1 terminal functions.................................................................. 9
Appendix Table 3 Hardware Option Function Setting ............................................ 10

1. Specifications and Configuration
- 1 -
1. Specifications and Configuration
Table 1-1 U2KV23PI0 specifications
Item Specifications
Parallel input section
Frequency setting/Speed setting
resolution Min. 0.01Hz (0.1rpm)
Data format Select from a total of eleven types including
binary/BCD, 8/16 bits
Synchronization method Select from synchronous method with strobe signal or
asynchronous method with sample
Data width Select from 16-bit non-multiplexed or 8-bit multiplexed
Circuit voltage/current 24VDC/5mA (tolerable leakage current 0.5mA)
Interface power 24V±10%, 0.2A or higher capacity to be provided by
the user.
Open collector output section
No. of points 2 points (PSO4, 5)
Max. voltage/current 30VDC/50mA
Control PCB
Parallel data
input section
Open collector
output section
TB1
CN1
V23-PI0 Option PCB
External power
supply for parallel
input
Fig. 1-1 Configuration

2. Installation Into Inverter
- 2 -
2. Installation Into Inverter
The installation procedure and points of caution are as described below.
(1)Remove the inverter unit's front cover.
CAUTION
1. Wait at least 20 minutes after turning the power OFF before starting work. Make sure that the
displays on the operation panel have gone out before removing the cover.
2. After removing the cover, confirm that the “CHARGE” LED on the unit has gone out.
Also check that the voltage between terminals L+1 or L+2 and L- is 15V or less before starting
the inspections.
(Check with the “CHARGE” LED if the unit is not provided with the L- terminal.)
(2)If the other option PCB is installed onto the position for option II on the control PCB cover,
install this PCB onto the position for option III.
Refer to Fig. 2-1.
(3)When wiring to TB1 use AWG26 to 16 (0.14 to 1.5mm2) for the wires.
Wires should be terminated correctly, with suitable crimp terminals or ferrules.
Pass the wires through the cable connection hole on the inverter unit and then connect.
CAUTION
1. Observe the cautions listed in Fig. 3-1 and Section 2-4 in the VAT2000 Instruction Manual
(PCST-3251) when wiring.

2. Installation Into Inverter
- 3 -
Option cover
Option
III
Control PCB cover
Option
I
Option
II
The mounting position
of V23-PI0
Fig. 2-1 Installation of optional PCB
NPSF - ST19 -
01
MEIDEN
N62P30449 1/5A MADE IN JAPAN
TB1
1
25
26
2
SOURCE
SINK1
W1
2
CP1
1
2
CN1
Fig. 2-2 Optional PCB

3. Parallel Data Input
- 4 -
3. Parallel Data Input
3-1. Connection and setting procedure
(1) Connection
The parallel data input connection is shown in Fig. 3-1.
The parallel data is input from CN1. CN1 is a DDK FRC2-C26L11-0L.
The flat cable (FRC2-AA26-10S) must be provided by the user.
CAUTION
1. The cable length must be 30m or less.
2. The external power can be supplied from the flat cable; but if the cable length is 2m or more,
supply the power from TB1.
The wires that can be used for TB1 are AWG26 to 16 (0.14 to 1.5mm2).
If the flat cable cannot be passed through the inverter unit's cable connection hole, remove the
plate of the cable connection hole.
In this case, the protective structure will be IP00.
CN125 1
26 2
Max. 30m
26-core
flat cable
Sequencer or digital switch
W1
1
2
Parallel data
input short pin
TB1
12
24V power
supply
EX0
EX24
Note) The 24V power supply is to be provided by the user
Fig. 3-1 Connection of parallel data input section
(2)Setting procedure
1) Decide the circuit format and data format.
2) Decide the circuit format (open collector/open emitter) with W1. (Fig. 3-5).
3) Turn ON the power, Set the parameter C02-0 to 2 (parallel fixed). (Refer to Fig. 5-9 in the
VAT2000 Instruction Manual (PCST-3251).)
4) Set the data input mode, circuit format, and parallel data format in C32-0 to C32-2.
Note) Set the A05-2 setting value to 1 to cancel the hardware option display skip when setting
the C32-0 to C32-2 parameters.
(The default value is display skip.)

3. Parallel Data Input
- 5 -
3-2. Data input mode selection and signal specifications
The following three methods can be used for the parallel input data input method.
1) 16-bit with strobe
2) 8-bit multiplexed with strobe
3) 16-bit sample
These methods are selected with parameter No. C32-0.
(1) 16-bit with strobe (C32-0 = 1)
The 16-bit data (D0 to 15) is loaded with the rising edge of the strobe (STB).
D0~D15
STB OFF
ON
Data 0 Data 1 Data 2
ts th
tcy
Data 0 Data 1
tw
tds
Internal data
Fig. 3-2 16-bit with strobe time chart
(2) 8-bit multiplexed with strobe (C32-0 = 2)
The 16-bit data is divided into the low-order 8-bit and high-order 8-bit with the LSB signal, and
each is loaded with the rising edge of the strobe (STB).
D0~D7
STB OFF
ON
Data 0 (high-order) Data 1 (low-order) Data 2 (high-order)
ts th
tcy
Data 0 Data 1
tw
tds
Internal data
LSB OFF
ON
Fig. 3-3 8-bit multiplexed with strobe time chart

3. Parallel Data Input
- 6 -
(3) 16-bit sample (C32-0 = 3)
The 16-bit data is sampled every 10mS, and is loaded when the data for four samples match.
tda
Data 0 Data 1
Data 0 Data 1 Data 2 Data 3
1234123412121
tsp
Note)
Data 2 and 3 are not loaded
in this case.
Fig. 3-4 Sample mode time chart
(4) Timing specifications
Table 3-1
Symbol Name Specifications
t cy Cycle time • 25mS
t w STB pulse width • 3mS
t s Data setup time • 2mS
t h Data hold time • 2mS
t ds Strobe delay 15 ~ 25mS
t da Sample mode delay 50 ~ 60mS
t sp Internal sample time 10 ± 2mS

3. Parallel Data Input
- 7 -
3-3. Signal logic and circuit format selection
(1) Signal logic selection (D0 ~ D15)
Dn = 1 when the contact connected to D0 to D15 is ON (closed circuit), or Dn = 1 when the
contact is OFF (open circuit) can be selected with parameter No. C32-1. (Appendix Table 3)
(2)Signal common selection (W1)
Setting of all signal commons to EX0 or EX24 can be selected with the W1 setting.
The sequence output method open collector and open emitter can both be corresponded to with
this.
V23-PI0
W1 EX0
EX24
1
2
D0~D15
TB1-2
TB1-1
STB,LSB
Controller such as sequencer
Open collector output
Open emitter output
External
24V power supply
+
-
5 K
5 K
Fig. 3-5 Short pin W1 setting

4. Usage of PSO Terminal Function
- 8 -
4. Usage of PSO Terminal Function
When using the U2KV23PI0 PSO4, 5 terminals, set parameter C33-0, 1 sequence output signal.
(Appendix Table 3)
Refer to Table 5-4 in the VAT2000 Instruction Manual (PCST-3251) for details on the sequence
output signal functions.
Table 4-1 PSO terminal settings
Sequence output signal
default values
Terminal Parameter No. setting data output signal
PSO4A-PSO4B-PSO4C C33-0 5 LCL
PSO5A-PSO5B-PSO5C C33-1 6 REV
The sequence output (PSO4, 5) terminals are laid out in CN1. (Appendix Table 1)
CN1-21
CN1-24
CN1-25,26
Load
max. 50mA max. 30V
PSO4
PSO5
V23-PI0
CN1-22,23
Fig. 4-1 PSO terminal connection

Appendix Table
- 9 -
Appendix Table 1 CN1 pin layout
Terminal No. Symbol Function
CN1 - 1 D0
- 2 D1
- 3 D2
- 4 D3
- 5 D4
- 6 D5
- 7 D6
- 8 D7
- 9 D8
- 10 D9
CN1 - 11 D10
- 12 D11
- 13 D12
- 14 D13
- 15 D14
- 16 D15
< Low significant bit >
Parallel data
< Most significant bit >
- 17 LSB Indicates low-order 8-bit when ON. (Use for 8-bit time
multiplexed mode)
- 18 STB Loaded at the strobe ON to OFF edge. (Use for strobe
mode)
- 19 EX24 External 24V power supply input for the parallel data
input
- 20 EX0 External 24V power supply input common for the
parallel data input
CN1 - 21 PSO4 PSO4 output terminal (open collector)
- 22 COM1
- 23 COM1 PSO output terminal common
- 24 PSO5 PSO5 output terminal (open collector)
- 25 COM1
- 26 COM1 PSO output terminal common
CN1
25 1
26 2
View from connector insertion side
1
Appendix Table 2 TB1 terminal functions
Terminal No. Symbol Function
TB1 - 1 EX24 External 24V power supply input for the parallel data
input
- 2 EX0 External 24V power supply input common for the
parallel data input

Appendix Table
- 10 -
Appendix Table 3 Hardware Option Function Setting
Block-C parameters (Basic function constants) list Application
No. Parameter Unit Default Min. Max. Function ST V/f VEC PM
C02 – Various setting input selection
0Speed setting input
points selection 4. 1. 4.
=1: Analog fixed
=2: Serial/parallel fixed
=3: Panel fixed
=4: Sequence
O
1Traverse center
frequency input
points selection 2. 1. 3. =1: Analog fixed
=2: Panel fixed
=3: Sequence O
2Torque setting
input points
selection 3. 1. 4.
=1: Analog fixed
=2: Serial fixed
=3: Panel fixed
=4: Sequence
OO
3Torque ratio 1
setting input points
selection 2. 1. 3. =1: Serial fixed
=2: Panel fixed
=3: Sequence OO
4Torque bias 1
setting input points
selection 3. 1. 4.
=1: Analog fixed
=2: Serial fixed
=3: Panel fixed
=4: Sequence
OO
5Torque ratio 2
setting input points
selection 2. 1. 3. =1: Serial fixed
=2: Panel fixed
=3: Sequence OO
6Drive/regenerative
torque limit input
points selection 3. 1. 3. =1: Analog fixed
=2: Serial fixed
=3: Sequence OO
7ASR response
input points
selection 2. 1. 3. =1: Serial fixed
=2: Panel fixed
=3: Sequence OO
8Machine time
constant input
points selection 2. 1. 3. =1: Serial fixed
=2: Panel fixed
=3: Sequence OO
Block-C parameters (H/W option function constants) list Application
No. Parameter Unit Default Min. Max. Function ST V/f VEC PM
C32 – PC (parallel) Interface
0Input mode
(strobe) 1. 1. 3. =1: 16-bit strobe
=2: 8-bit time multiplexed strobe
=3: 16-bit sample O
1Input mode (input
logic) 1. 1. 2. =1: 1 at closed circuit
=2: 1 at opened circuit O
2 Data format 1. 0. 10. Set according to the following
table. O
Setting data Format Setting resolution Setting range
0
1
2
3
16-bit binary
16-bit binary
16-bit binary
16-bit binary
0.01Hz/LSB (0.1rpm/LSB)
0.1Hz/LSB ( 1rpm/LSB)
0.01%LSB
0.1%LSB
0 to 440.00Hz (0.0 to 6553.5rpm or Nmax)
440.0Hz (0 to Nmax rpm)
100.00%
100.0%
4
5
6
7
16-bit BCD
16-bit BCD
16-bit BCD
16-bit BCD
0.01Hz/LSB (0.1rpm/LSB)
0.1Hz/LSB ( 1rpm/LSB)
0.01%LSB
0.1%LSB
99.99Hz (0.0 to 999.9rpm)
100.0Hz (0 to Nmax rpm)
99.99%
100.0%
8
9
10
8-bit binary
12-bit binary
16-bit binary
1/255%
1/4095%
1/65535%
100.0%
100.0%
100.0%
Hz = Frequency setting [ For V/f control (Constant torque, reduced torque) (C30-0 = 1, 2) ]
rpm: Speed setting For IM speed sensorless vector control (C30-0 = 3)
For IM speed vector control (C30-0 = 4)
For PM motor control (C30-0 = 5)
Set this when the Parallel interface option (U2KV23PL0) has been mounted.

Appendix Table
- 11 -
Block-C parameters (H/W option function constants) list Application
No. Parameter Unit Default Min. Max. Function ST V/f VEC PM
C33 – Sequence output terminal function (Option)
0PSO4 Output
parameters 5. 0. 24. O
1PSO5 Output
parameters 6. 0. 24.
Set this when the relay interface
option (U2KV23RY0) and Parallel
interface option (U2KV23PI0) are
mounted.
Refer to Instruction Manual
(PCST-3301) for other details. O
Value Output
signal Value Output
signal Value Output
signal Value Output
signal
0 RUN 8 ATN 16 ACC 24 ULMT
1 FLT 9 SPD1 17 DCC
2 MC 10 SPD2 18 AUXDV
3 RDY1 11 COP 19 ALM
4RDY2 12EC0 20FAN
5 LCL 13 EC1 21 ASW
6 REV 14 EC2 22 ZSP
7 IDET 15 EC3 23 LLMT
Other manuals for VAT2000 Series
2
This manual suits for next models
1
Table of contents
Other GE Controllers manuals
Popular Controllers manuals by other brands

Mitsubishi Electric
Mitsubishi Electric MELSEC iQ-R Series user manual

Dynamite
Dynamite DYNM3865 instruction manual

Yisutongma Network Technology
Yisutongma Network Technology ESM-9013 instruction manual

Skov
Skov DOL 278AT user manual

NI
NI sbRIO-961 series quick reference

Federal Signal Corporation
Federal Signal Corporation UltraVoice Installation, operation and service manual