913-326A 2 of 7
November 2005
Foundation Fieldbus
Communications
Foundation Fieldbus provides a means of communicating with the XMT
flowmeter. The patent numbers which apply are 5,909,363 and 6,424,872.
This Foundation Fieldbus device supports 2 Analog Input (AI) blocks,
which can be configured to supply the following measurements on the
network.
Table 1: Available Measurements
Description Units Description Units Description Units
Ch1 Velocity ft/s or m/s* Ch2 Totalizer Time seconds Ch1 Power POWER_U
Ch1 Volumetric VOL_U Ch2 Error Value none Ch1 +Energy ENERGY_U
Ch1 +Totals TOT_U Ch2 SSUP none Ch1 –Energy ENERGY_U
Ch1 -Totals TOT_U Ch2 SSDN none Ch1 TempS Deg F or C*
Ch1 Tot Digits** none Ch2 SNDSP ft/s or m/s* Ch1 TempR Deg F or C*
Ch1 Totalizer Time seconds Avg Velocity ft/s or m/s* Ch1 TS-TR Deg F or C*
Ch1 Error Value none Avg Volumetric VOL_U Ch1 DELTH Btu/lb J/gm
Ch1 SSUP none Avg +Totals TOT_U Ch2 Power POWER_U
Ch1 SSDN none Avg -Totals TOT_U Ch2 +Energy ENERGY_U
Ch1 SNDSP ft/s or m/s* Avg Tot Digits** none Ch2 –Energy ENERGY_U
Ch2 Velocity ft/s or m/s* Avg Totalizer Time seconds Ch2 TempS Deg F or C*
Ch2 Volumetric VOL_U Avg Error Value none Ch2 TempR Deg F or C*
Ch2 +Totals TOT_U Avg SSUP none Ch2 TS-TR Deg F or C*
Ch2 –Totals TOT_U Avg SSDN none Ch2 DELTH Btu/lb J/gm
Ch 2 Tot Digits** none Avg SNDSP ft/s or m/s*
*Metric or English units are determined by the setup of the XMT868 flow meter.
**Totalizer digits are available for informational purposes only. Respective totals are automatically scaled by
the Tot Digits value selected in the XMT flow meter setup.
VOL_U, TOT_U, POWER_U and ENERGY_U are determined by the units chosen for these measurements in the
setup for the XMT868 flow meter. See the instrument User's Manual for the setup of these parameters.