gebatronic Cody Universal 3 User manual

X0506 V1.1
Cody Universal
3
GB
Assembly, connection and maintenance of the device
may only be executed by personnel trained accordingly.
At this the underlying national and local regulations have
to be observed.

The Cody Universal 3 consists of a decoder and a control
element. The units are connected by a simple two-wire cable
without a special plug. Programming of the Cody Universal 3 is
possible with the keypad and the master code.
The Cody Universal 3 gives you the possibility of direct control of
an industrial door control. fter entering a valid pass code, the
user can use the STOP button and the arrow keys
UP and DOWN to drive a motor in dead man.
The two relays are electrically interlocked, so it is not possible
that both relays are activated simultaneously.
Mastercode:
The mastercode is an 8 digit numeral code necessary for all
programming procedures.
Only after the input of this code the appliance can be
programmed according to your personal needs. Cody Universal 3
is preset by the company with the master code 12345678.
Pass code:
The pass code is either a four or five digit numeral code, by which
you operate your door drive unit. You have the possibility to store
up to 50 different pass codes, which means that up to 50 different
persons with individual pass codes can open the door. If you are
accompanied by another person when entering your pass code
you can first press as many keys as you like before you finally
enter your code. This ensures that no other person can
notice your pass code. The Cody Universal 2 is preset with the
pass code 1234 on memory slot 00.
Gerätebeschreibung
Note: Optional Cody Universal Service ool
The Cody Universal Service Tool gives you the possibility to program
your Cody Universal conveniently to your requirements.
LCD display shows you every programming step, including the # of a
used memory slot, relays settings etc.
It also allows you to delete transponders directly by their used memory
slot.
Ref. 500.S U0.00

A EN ION!!!
After you have made yourself familiar with the functions of the
appliance, please program your personal mastercode as well as a
pass code with which you replace the pass code which is located
on the memory place 00. Only by this your Cody Universal 3 is
protected against manipulation!
IP OMA IC:
The Cody Universal 3 has three potential free relay outputs enabling
direct control of a industrial door control unit. fter having entered a
valid pass code the user can, within a period of 60 seconds, trigger the
installed drive unit in the dead man’s mode with the STOP button or
the arrow keys UP and DOWN .
The relay is activated only as long as the arrow keys are pushed. The
relays are interlocked against each other, so it is not possible that both
relays can be switched at the same time. fter expiration of the of 60
seconds the Cody Universal 3 locks automatically. This function,
however, can be interrupted prior to the expiration of the 60 seconds,
by pressing the button.
Lock-out function:
If the lock-out function is activated, the Cody Universal 3 automatically
blocks any input for a set period after the input of a wrong pass code
which is signalled with a (3 beeps) sound signal.
You can freely program the lock-out time according to your
requriments.
The end of the lock-out time is signalled by a long sound signal.
General reset
General reset
Push reset button
on the PCB
> 5 sec.
Factory settings (default settings):
all slots erased (except 00)
mastercode = sequence 1-8
pass code 00 = sequence 1-4
Tiptomatic time = 60 sec.
look-out time = 20 sec.
Put DIP switch 4 to
ON Put DIP switch
back to OFF
All factory settings are restored by the general reset !

geba GmbH is released of its obligations regarding guarantee and product liability if – without prior
permission - the unit has been modified, or if the installation is unproper or not in accordance with our
instruction manual. The installer has to take care that the EMC-regulations are respected.
Interior mounting of the logic:
1. Put the screw-driver into the gap of the enclosure front, push the screw-driver up and
open the enclosure.
2. Remove the control PCB (which is force fitted to the inside of the enclosure).
3. Locate the screwed glands supplied (sealing nipple left side) in the
enclosure and replace the PCB. (Please ensure PCB is firmly in position)
4. Bore the fastening holes and fix the enclosure bracket at the wall.
5. The wires for the keyboard ensure through the left cable entry (sealing nipple), the wires
for the relay contact through the middle cable entry and the wires for the supply voltage ensure
through the right cable entry. Ensure tight seating of sealing nipple and cable gland, otherwise the
water-protection ot the appliance cannot be assured.
6. ccording to connection diagram connect the wires to the corresponding terminals:
Mounting instructions
he specific transmitter is now deleted!
RC transmitter
Program 2
Deleting of remote controls
Delete specific transmitter:
he taught-in transmitters are now all deleted !
Set DIP 1 to
ON
Press the button of the
RC transmitter
> 5 sec.
Put all DIP to OFF
Press the reset
button on the
logic board
> 5 sec.
Put
DIP 4 to ON LED flashes
2x long
Delete all transmitters :
Put all DIP to OFF
Put
DIP 4 to ON Set DIP 1 to
ON

Transponder
230/240V C
DOWN
UP
STOP
(NO)
(NC)
(NO)
This product complies with:
EC Electromagnetic Compatibility Directives
EN 61000-6-1 08/2002
EN 61000-6-3 08/2002
Low Voltage Directive 2006/42/EC
echnical Data:
Supply voltage: 20-28V C/DC, 230-240 V C
Output: 250V C 5
Connections: 1.5 mm² max.
mbient temperature: -20 °C to +60 °C
Keypad
Program 1
each-in of remote controls
RC transmitter
Make sure before the teach-in that the optional wireless module is plugged in firmly at the logic board.
he transmitter is programmed !
Put DIP 4 to ON
Press the desired
button on the remote
control LED flashes
1x long
Put DIP 1 to
ON
Put all DIP to OFF

Transponder
All keys of this specific block are now deleted !
Delete all transponder keys of an individual relay or block:
he individual transponder key is now deleted!
Put DIP of the
specific block or
relay (1/2/3) to ON
Press reset button
on the logic board
> 5 sec Set all DIP to
OFF
Program 2
Deleting transponder keys
Delete specific keys:
LED flashes
(2x long)
Put DIP of the
taught-in key
to ON
Put the desired
key to the
reader Set all DIP to
OFF
Keypad
Programming
instructions
Please read first - then do the programming!!!
Before programming your Cody Universal 3 with your personal codes, please check the faultless
function of the appliance with the help of the factory‘s pass code 1234 and the button.
Usually, any programming is made via your personal mastercode. In order to get familiar with that kind
of programming, you start with the input of a new pass code, which replaces the one preset by the
factory (1234). The procedure is explained under item “Program 2“.
fter that please change the factory set mastercode to your personal code of choice.
Attention / Note
In case you made a mistake on programming, you can start over again by pushing the
button
Factory setting = 1-8
Program 1
Input of a new mastercode
Enter 8 digit
mastercode
he new mastercode is now saved!
Sound signal
2x long
push
button
push
button
Sound signal
1x long
Enter 8 digit
NEW
mastercode
button
push

Transponder
* Note:
Cody Universal 3
The keys are distributed among three blocks with each 255 keys of on color. The blocks
correspond to the first 3 DIP switches.
Program 1
each-in of transponder keys
Put the desired
key to the
reader
LED flashes
(1x long)
Put DIP of the
desired relay or block
* (1/2/3) to ON
Set all DIP to
OFF
TTENTION:
It is not possible to teach-in key different colors in one and the same block!
The reader should not be mounted directly on metal. Then use a spacer case (No. 508.000G.00).
he transponder key is programmed to the desired block!
push
button
push
button
Program 2
Creating a new pass code
Factory setting = 1- 4
sound signal
2x long
Enter 8 digit
mastercode
Enter 2 digit
memory slot,
e.g. 07 or 28
push
button
Enter 4 or 5
digit pass code sound signal
1x long
he new pass code is now saved!
You can enter up to 50 different pass on the memories 00-49!
he entered pass code is now stored in the selected memory slot !
he selected memory slot of the pass code
is now deleted!
push
button
push
button
sound signal
2x long
Enter 8 digit
mastercode
Enter 2 digit
memory slot,
e.g. 07 or 28
push
button
push
button
sound signal
1x long
Program 3
Deleting a pass code
Keypad

S OP
Program 6
Entering a pass code
Keypad
Enter 4 or 5 digit
pass code
button
push
sound signal
1x long
Before the actual pass code, you can press any other keys to prevent fraud.
If an incorrect pass code is entered, you will hear a sound signal (3 beeps).
Entering a new pass code is only possible after the lock-out period (factory: 20 sec.) which end is
signalled by a long sound signal.
A correct code is detected, the corresponding relay is switched!
Program 5
Changing the control time - lock-out time
Enter 8 digit
mastercode
Enter 3 digit
time 001-255
he modified lock-out time is saved!
*Lock out time:
dynamic = The lock-out time is extended by 10 sec. with
every wrong entry (max. 255 sec.)
static = The lock-out time is according the set time( 000 = turned off)
= dynamic*
= static*
button
push
button
push
sound signal
1x long
sound signal
1x long
sound signal
2x long
push
button button button
push push
Program 4
Changing the control time / iptomatic time
Enter 8 digit
mastercode
he modified iptomatic time is saved!
his set time is the same for all relays (factory 60 sec.).
Enter 3 digit
time 001-255
push
button
push
button
push
button
push
button
sound signal
2x long
sound signal
1x long push
push
push
button
button
button
Keypad
Table of contents
Other gebatronic Keypad manuals