3. INSTALLATION - USE
3.1. Safety Warnings
• The persons who are in charge of assembly should have the required qualifications for this type of work.
• Avoid making contact with the electric voltage.
• Comply with the current standards regarding accident prevention.
In this regard, the IEC 364-7-702 standards must be observed:
WIRING IN BUILDINGS. SPECIAL WIRING. SWIMMING POOLS.
• Any operation related to the maintenance or replacement of parts should be performed with the light’s electricity
disconnected from the main power.
• Any electrical material should not be touched with wet hands and feet.
2
3.2. Mounting
The persons who are in charge of assembly should have the required qualifications for this type of work.
Before starting the installation, make sure that the disconnect the line from the lamps. RGB lights must be
connected to a single source of suitable capacity. The lamp should be operated only under water and fixed
to the vertical wall of the pool. The lamp must not be operated if it is not under water.
• Lamp in concrete pools with
two dowels and two screws
frame. In addition, it can be
easily mounted on the pool
wall (concrete, polyester,
lining) with the mounting
apparatus.
• The insulation seal is
adhered to meet the holes on
the lamp connection nozzle.
• The mounting bracket is
fixed to the lamp connection
nozzle with 6 (six) screws as
shown in the photo, meeting
the same holes on the gasket.
• The cable connections of the lamp are made:
- Before starting the connection process, make sure that the line is de-energized
- Connect the power cable of the lamp to the appropriate voltage line (12VAC / DC).
- Make sure that the power cable connections are tight and correct.
- Cable splices should be made with specially insulated waterproof tubing or watertight cable splice connector.
• The lamp is placed on the mounting bracket to meet the screw holes on the mounting bracket and the holes on the
frame.
• Screw the lamp onto the mounting bracket using the screw holes on the frame.
3.2.1. Niche Mounting with Exchange Kit