Gemas ECOSLIM LED LIGHT Manual

INSTALLATION AND MAINTENANCE MANUAL
KURULUM VE BAKIM TALİMATI
Version: 2.0
ECOSLIM LED LIGHT
ECOSLIM LED LAMBA

2. TECHNICAL FEATURES
Ambient temperature should be maximum 30°C.
Changes in ambient temperature and product temperature alter current and light intensity values.
The light should never be operated without a transformer.
No voltage above 12V ± 2V should definitely go to the light.
The maximum operating temperature of the light is 30°C.
This guide; It contains basic information about the security measures to be applied for
installation and use. Therefore, the person and user to install; should read these instructions
carefully before installation and operation. Keep this manual for future reference.
1. GENERAL FEATURES
• It has a special, elegant, stylish and patented design.
• It can be easily installed in all swimming pools.
• Compatible with all PAR56 lamp niche on the market.
• It gives instant beam thanks to the LEDs used in the light.
• Light scattering angle is 120 °.
• The light complies with IP68 protection degree at 2 m nominal depth.
• Diffuser glass is made of polycarbonate.
• Body part consists of gray PA6.
• The light operating voltage is very low (12V AC / DC), making it a Class III electrical device.
• Energy input cable length is 1 meter.
1
ENGLISH
Name Number of
Leds
Voltage
(±2V)
Power
(Watt)
Luminous
Flux (Lumen)
Light Beam
Angle
ECOSlim White
EC lim Daylight
ECOSlim Turquoise
ECOSlim Blue
ECOSlim Red
ECOSlim Green
ECOSlim RGB Built-in Control
ECOSlim RGB Central Control
72
72
72
72
72
72
72
72
12V AC/DC
12V AC/DC
12V AC/DC
12V AC/DC
12V AC/DC
12V AC/DC
12V AC/DC
12V DC
24
24
20
20
20
20
20
20
1614
1614
671
671
671
671
671
671
120 Ý
120 Ý
120 Ý
120 Ý
120 Ý
120 Ý
120 Ý
120 Ý
100mm
35mm
168mm
278mm
191mm
100mm
Ø 168mm
29mm
14,50mm
Ø 176mm
Ø 168mm
179mm

3. INSTALLATION - USE
3.1. Safety Warnings
• The persons who are in charge of assembly should have the required qualifications for this type of work.
• Avoid making contact with the electric voltage.
• Comply with the current standards regarding accident prevention.
In this regard, the IEC 364-7-702 standards must be observed:
WIRING IN BUILDINGS. SPECIAL WIRING. SWIMMING POOLS.
• Any operation related to the maintenance or replacement of parts should be performed with the light’s electricity
disconnected from the main power.
• Any electrical material should not be touched with wet hands and feet.
2
3.2. Mounting
The persons who are in charge of assembly should have the required qualifications for this type of work.
Before starting the installation, make sure that the disconnect the line from the lamps. RGB lights must be
connected to a single source of suitable capacity. The lamp should be operated only under water and fixed
to the vertical wall of the pool. The lamp must not be operated if it is not under water.
• Lamp in concrete pools with
two dowels and two screws
frame. In addition, it can be
easily mounted on the pool
wall (concrete, polyester,
lining) with the mounting
apparatus.
• The insulation seal is
adhered to meet the holes on
the lamp connection nozzle.
• The mounting bracket is
fixed to the lamp connection
nozzle with 6 (six) screws as
shown in the photo, meeting
the same holes on the gasket.
• The cable connections of the lamp are made:
- Before starting the connection process, make sure that the line is de-energized
- Connect the power cable of the lamp to the appropriate voltage line (12VAC / DC).
- Make sure that the power cable connections are tight and correct.
- Cable splices should be made with specially insulated waterproof tubing or watertight cable splice connector.
• The lamp is placed on the mounting bracket to meet the screw holes on the mounting bracket and the holes on the
frame.
• Screw the lamp onto the mounting bracket using the screw holes on the frame.
3.2.1. Niche Mounting with Exchange Kit

3.3.2. Multiple Light Synchronization
Check the lights after connecting and activating all RGB lights. Make sure all lights work in different colors. Turn off the
power and turn it back on after 4-7 seconds. After this process, all RGB lights will turn to the first light pattern (RED).
By using the color changing function (by cutting the energy and re-energizing within 3 seconds), you can use all RGB
lights in any color or animation you desire.
4. MAINTENANCE
There is no need for any maintenance for this lamp. If there is a deterioration, it must be replaced. Make sure the lamp
is de-energized before any operation. Make sure that the new lamp is the same model and feature as the replaced
lamp.
5. GUARANTEE
The manufacturer warrants this light against manufacturing defects and material defects for a period of 2 years from
the date of purchase. This warranty does not cover damage caused by misuse, accidental damage, failures arising from
the installation of unauthorized persons and does not assume direct liability.
Loremipsum
3
RGB Light Has 13 Different Lighting Patterns Detailed Below:
Red Green Blue Red and Green Red and Blue Blue and Green Red Green Blue
Light Conversion 256 Color Tone Changing Flashing Seven Intermediate Color Tones
Sixteen Color Change Single Color Change
3.3. Use and Color Changing
The lamp is energized (12VAC / DC) after making sure that the installation and electrical connection is done correctly.
There is no color changing and color transition feature in single color lamps. Color changing and transition of RGB lamps
(within 3 seconds) is provided by cutting off the energy and re-energizing. This process is repeated and different colors
and animations are performed. Thanks to the GEMAS 2T RGB Lamp Control units designed for this process, it can be
made very comfortably and with a remote control.
3.3.1. RGB Light Mode List

*(1(/g=(//ú./(5
•g]HO]DULIü×NYHSDWHQWOLELUWDVDU×PDVDKLSWLU
7P\]PHKDYX]ODU×QDNROD\O×NODPRQWDM×\DS×ODELOLU
3L\DVDGDNLWP3$5ODPEDNRYDQODU×LOHX\XPOXGXU
/DPEDLoHULVLQGHNXOODQ×ODQ/('OHUVD\HVLQGHDQ×QGD×ü×NYHULU
,ü×NGDù×OPDDo×V×·GLU
• Lamba, 2 m nominal derinlikte IP68 koruma derecesine uygundur.
'LI]|UFDP×SROLNDUERQDWWDQUHWLOPLüWLU
*|YGHN×VP×JUL3$GDQROXüPDNWDG×U
/DPEDoDO×üPDYROWDM×oRNGüNROGXùXQGDQ9$&'&6×Q×I,,,NDSVDP×QGDHOHNWULNOLELUFLKD]G×U
(QHUMLJLULüNDEORVXX]XQOXùXPHWUHGLU
7(.1ú.g=(//ú./(5
2UWDPV×FDNO×ù×PDNVLPXP&ROPDO×G×U
2UWDPV×FDNO×ù×YHUQV×FDNO×ù×QGDNLGHùLüLNOLNDN×PYH×ü×NüLGGHWLGHùHUOHULQLGHùLüWLUPHNWHGLU
úVLP Led
6D\×V×
Voltaj
(±2V)
Güç
(W)
,ü×N$N×V×
(LM)
Led
$o×V×
ECOSlim Beyaz
(&26OLP*Q×ü×ù×
ECOSlim Turkuaz
ECOSlim Mavi
(&26OLP.×UP×]×
(&26OLP<HüLO
ECOSlim RGB Kendinden Entegreli
ECOSlim RGB Merkezi Entegreli
72
72
72
72
72
72
72
72
12V AC/DC
12V AC/DC
12V AC/DC
12V AC/DC
12V AC/DC
12V AC/DC
12V AC/DC
12V DC
24
24
20
20
20
20
20
20
1614
1614
671
671
671
671
671
671
120 Ý
120 Ý
120 Ý
120 Ý
120 Ý
120 Ý
120 Ý
120 Ý
/DPEDNHVLQOLNOHWUDQVIRUPDW|UROPDGDQoDO×üW×U×OPDPDO×G×U
/DPED\DNHVLQOLNOH99]HULYROWDMJLWPHPHOLGLU
/DPEDQ×QPDNVLPXPoDO×üPDV×FDNO×ù×&·GLU
%XN×ODYX]NXUXOXPYHNXOODQ×PLoLQX\JXODQDFDNJYHQOLN|QOHPOHULQHLOLüNLQWHPHOELOJLOHUL
LoHULU %X QHGHQOH NXUXOXPX \DSDFDN NLüL YH NXOODQ×F× NXUXOXP YH NXOODQ×P |QFHVL EX
WDOLPDWODU×GLNNDWOLFHRNXPDO×G×U%XN×ODYX]XLOHULGHEDüYXUPDN]HUHVDNOD\×Q×]
TÜRKÇE
4
100mm
35mm
168mm
278mm
191mm
100mm
Ø 168mm
29mm
14,50mm
Ø 176mm
Ø 168mm
179mm

0RQWDMGDQVRUXPOXNLüLOHUEXWULüOHULoLQJHUHNOLQLWHOLNOHUHVDKLSROPDO×G×U0RQWDMLüOHPLQHEDüODPDGDQ
|QFH KDWW×Q HQHUMLVLQLQ NHVLN ROGXùXQGDQ HPLQ ROXQX] 5*% ODPEDODU X\JXQ NDSDVLWHOL WHN ELU ND\QDùD
EDùODQPDO×G×U/DPEDVDGHFHVXDOW×QGDYHKDYX]XQGLNH\GXYDU×QDVDELWOHQPLüüHNLOGHoDO×üW×U×OPDO×G×U6X
DOW×QGDGHùLOLVHDVODODPEDoDO×üW×U×OPDPDO×G×U
3. KURULUM - KULLANIM
3*YHQOLN8\DU×ODU×
•0RQWDMGDQVRUXPOXNLüLOHUEXWULüOHULoLQJHUHNOLQLWHOLNOHUHVDKLSROPDO×G×U
(OHNWULNYROWDM×\ODWHPDVHWPHNWHQNDo×Q×OPDO×G×U
.D]DODU×Q|QOHQPHVLQHLOLüNLQPHYFXWVWDQGDUWODUDX\XOPDO×G×U
BuEDùODPGD,(&VWDQGDUWODU×QDX\XOPDO×G×U
%ú1$/$5'$(/(.75ú.7(6ú6$7,g=(/(/(.75ú.7(6ú6$7,<h=0(+$98=/$5,
•3DUoDODU×QEDN×P×YH\DGHùLüLPL\OHLOJLOLKHUWUOLüOHPODPED\DJLGHQHOHNWULNNHVLOGLNWHQVRQUD\DS×OPDO×G×U
,VODNHOYHD\DNODKHUKDQJLELUHOHNWULNOLPDO]HPH\HGRNXQXOPDPDO×G×U
3.2. Montaj
• Lamba beton havuzlarda iki
adet dubel ve iki adet vida ile
çerçeve üzerindeki
deliklerden direk duvara
PRQWDM\DS×ODELOLU$\U×FD
PRQWDMDSDUDW×LOHKDYX]
GXYDU×QDEHWRQSRO\HVWHU
OLQHUUDKDWELUüHNLOGHPRQWDM×
\DS×ODELOLU
• YDO×W×PFRQWDV×ODPED
EDùODQW×QR]XOX]HULQGHNL
GHOLNOHULNDUü×OD\DFDNüHNLOGH
\DS×üW×U×O×U
• MRQWDMDSDUDW×FRQWD]HULQH
D\Q×GHOLNOHULNDUü×OD\DFDNüHNLOGHIRWRùUDIWDJ|UOGùJLELDOW×DGHWYLGDLOHODPEDEDùODQW×QR]XOXQDVDELWOHQLU
• LDPEDQ×QNDEOREDùODQW×ODU×\DS×O×U
- %DùODQW×LüOHPLQHEDüODPDGDQ|QFHKDWW×QHQHUMLVLQLQNHVLNROGXùXQGDQHPLQROXQX]
/DPEDQ×QHQHUMLNDEORVXQXX\JXQYROWDMKDWW×QD9$&'&EDùOD\×Q×]
(QHUMLNDEORVXEDùODQW×ODU×Q×QV×N×YHGRùUXROGXùXQGDQHPLQROXQX]
.DEORHNEDùODQW×ODU×|]HOL]ROHOLVXJHoLUPH]PDNDURQLOHYH\DVXJHoLUPH]NDEORHNNRQQHNW|ULOH\DS×OPDO×G×U
dHUoHYH]HULQGHEXOXQDQGHOLNOHULOHPRQWDMDSDUDW×]HULQGHNLYLGDGHOLNOHULELUELULQLNDUü×OD\DFDNüHNLOGHODPED
PRQWDMDSDUDW×]HULQHRWXUWXOXU
• ÇHUoHYH]HULQGHNLYLGDGHOLNOHULNXOODQ×ODUDNODPEDPRQWDMDSDUDW×QDYLGDODQ×U
'HùLüLP.LWLúOH.RYDQD0RQWDM
5

Loremipsum
dRNOX/DPED6HQNURQL]DV\RQX
7P5*%ODPEDODU×EDùOD\×SGHYUH\HDOG×NWDQVRQUDODPEDODU×NRQWUROHGLQ7PODPEDODU×QIDUNO×UHQNOHUGHGHROVD
oDO×üW×ù×QGDQHPLQROXQ(QHUML\LNDSDW×QYHVDQL\HVRQUDWHNUDUHQHUML\LDo×Q%XLüOHPVRQUDV×WP5*%ODPEDODU
LON×ü×NPRGHOLQH.,50,=,G|QHFHNWLU5HQNGHùLüWLUPHIRQNVL\RQXQXNXOODQDUDNVDQL\HLoHULVLQGHHQHUMLQLQNHVLOLS
WHNUDUHQHUMLYHULOPHVL\OHWP5*%ODPEDODU×LVWHQLOHQUHQNYH\DDQLPDV\RQGDNXOODQDELOLUVLQL]
4. BAKIM
BuODPEDLoLQKHUKDQJLELUEDN×PDJHUHN\RNWXU(ùHUELUER]XOPDROXUVDGHùLüLPLJHUHNPHNWHGLU+HUKDQJLLüOHPGHQ
|QFHODPEDQ×QHQHUMLVLQLQNHVLNROGXùXQGDQHPLQROXQ<HQLODPEDQ×QGHùLüWLULOHQODPEDLOHD\Q×PRGHOYH|]HOOLNWH
ROGXùXQGDQHPLQROXQ
*$5$17ú
hUHWLFLEXODPED\×VDW×QDOPDWDULKLQGHQLWLEDUHQ\×OER\XQFDLPDODWKDWDODU×QDYHPDO]HPHER]XOPDODU×QDNDUü×JDUDQWL
HGHU%XJDUDQWLKDWDO×NXOODQ×PQHGHQL\OHROXüDQKDVDU×ND]DUDRODQKDVDU×\HWNLVL]NLPVHOHULQPRQWDM×QGDQND\QDNO×
DU×]DODU×NDSVDPD]YHGRùUXGDQVRUXPOXOXNVWOHQPH]
.XOODQ×PYH5HQN'HùLüWLUPH
0RQWDMYHHOHNWULNVHOEDùODQW×LüOHPLQLQGRùUX\DS×OG×ù×QDHPLQROGXNWDQVRQUDODPED\DHQHUMLYHULOLU9$&'&7HN
UHQNODPEDODUGDUHQNGHùLüWLUPHYHUHQNJHoLüL|]HOOLùLEXOXQPDPDNWDG×U5*%ODPEDODUGDUHQNGHùLüWLUPHYHJHoLüL
VDQL\HLoHULVLQGHHQHUMLQLQNHVLOLSWHNUDUHQHUMLYHULOPHVL\OHVDùODQ×U%XLüOHPWHNUDUODQDUDNIDUNO×UHQNOHUYHDQLPDV\RQODU
JHUoHNOHüWLULOLU%XLüOHPLoLQWDVDUODQP×ü75*%/DPED.RQWUROQLWHOHULVD\HVLQGHoRNUDKDWELUüHNLOGHYHX]DNWDQ
NXPDQGDLOH\DS×ODELOPHNWHGLU
5*%,ü×N0RGX/LVWHVL
6
5*%/DPEDIDUNO××ü×NPRGHOLQHVDKLSWLU
.×UP×]× <HüLO Mavi .×UP×]×YH<HüLO .×UP×]×YH0DYL 0DYLYH<HüLO .×UP×]×<HüLO0DYL
,ü×N'|QüWUPH 5HQN7RQX'HùLüWLUPH <DQ×S6|QPH Yedi Ara Renk Tonu
2Q$OW×5HQN'HùLüLPL 7HN5HQN'HùLüWLUPH

• We reserve to change all of the articles or contents of this document, without prior notice.
)LUPDP¿]EXEHOJHQLQLoHUL½LQGHKDEHUYHUPHNVL]LQGH½LÁOLNOHU\DSDELOLU
This manual suits for next models
1
Table of contents
Other Gemas Swimming Pool Lighting manuals
Popular Swimming Pool Lighting manuals by other brands

Halco
Halco J&J Electronics PureWhite LPL-P2-WHT-12 Installation and operation guide

Champlain
Champlain ACM-125 Installation

Pentair Pool Products
Pentair Pool Products SpaBrite Installation procedures

weltico
weltico EASYLED instruction manual

Wiedamark
Wiedamark LPL-6 Series instructions

Steinbach
Steinbach 060060 instructions