manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. GEZE
  6. •
  7. Security Sensor
  8. •
  9. GEZE GC 173 User manual

GEZE GC 173 User manual

GC 173
Wireless ceiling-mounted
thermal detector
EN Supplementary sheet
183155_01
Germany
GEZE GmbH
Niederlassung Süd-West
Tel. +49 (0) 7152 203 594
E-Mail: [email protected]
GEZE GmbH
Niederlassung Süd-Ost
Tel. +49 (0) 7152 203 6440
E-Mail: [email protected]
GEZE GmbH
Niederlassung Ost
Tel. +49 (0) 7152 203 6840
E-Mail: [email protected]
GEZE GmbH
Niederlassung Mitte/Luxemburg
Tel. +49 (0) 7152 203 6888
E-Mail: [email protected]
GEZE GmbH
Niederlassung West
Tel. +49 (0) 7152 203 6770
E-Mail: [email protected]
GEZE GmbH
Niederlassung Nord
Tel. +49 (0) 7152 203 6600
E-Mail: [email protected]
GEZE Service GmbH
Tel. +49 (0) 1802 923392
E-Mail: service-info[email protected]
Austria
GEZE Austria
E-Mail: [email protected]
www.geze.at
Baltic States –
Lithuania / Latvia / Estonia
E-Mail: [email protected]
Benelux
GEZE Benelux B.V.
E-Mail: [email protected]
www.geze.be
www.geze.nl
Bulgaria
GEZE Bulgaria - Trade
E-Mail: o[email protected]
www.geze.bg
China
GEZE Industries (Tianjin) Co., Ltd.
E-Mail: [email protected]
www.geze.com.cn
GEZE Industries (Tianjin) Co., Ltd.
Branch Oce Shanghai
E-Mail: [email protected]
www.geze.com.cn
GEZE Industries (Tianjin) Co., Ltd.
Branch Oce Guangzhou
E-Mail: [email protected]
www.geze.com.cn
GEZE Industries (Tianjin) Co., Ltd.
Branch Oce Beijing
E-Mail: [email protected]
www.geze.com.cn
France
GEZE France S.A.R.L.
E-Mail: [email protected]
www.geze.fr
Hungary
GEZE Hungary Kft.
E-Mail: oce-hungar[email protected]
www.geze.hu
Iberia
GEZE Iberia S.R.L.
E-Mail: info.es@geze.com
www.geze.es
India
GEZE India Private Ltd.
E-Mail: o[email protected]
www.geze.in
Italy
GEZE Italia S.r.l. Unipersonale
E-Mail: [email protected]
www.geze.it
GEZE Engineering Roma S.r.l
E-Mail: [email protected]
www.geze.it
Korea
GEZE Korea Ltd.
E-Mail: [email protected]
www.geze.com
Poland
GEZE Polska Sp.z o.o.
E-Mail: [email protected]
www.geze.pl
Romania
GEZE Romania S.R.L.
E-Mail: o[email protected]
www.geze.ro
Russia
OOO GEZE RUS
E-Mail: o[email protected]
www.geze.ru
Scandinavia – Sweden
GEZE Scandinavia AB
E-Mail: [email protected]
www.geze.se
Scandinavia – Norway
GEZE Scandinavia AB avd. Norge
E-Mail: [email protected]
www.geze.no
Scandinavia – Denmark
GEZE Danmark
E-Mail: [email protected]
www.geze.dk
Singapore
GEZE (Asia Pacic) Pte, Ltd.
E-Mail: [email protected]
www.geze.com
South Africa
GEZE South Africa (Pty) Ltd.
E-Mail: [email protected]
www.geze.co.za
Switzerland
GEZE Schweiz AG
E-Mail: [email protected]
www.geze.ch
Turkey
GEZE Kapı ve Pencere Sistemleri
E-Mail: o[email protected]
www.geze.com
Ukraine
LLC GEZE Ukraine
E-Mail: o[email protected]
www.geze.ua
United Arab Emirates/GCC
GEZE Middle East
E-Mail: [email protected]
www.geze.ae
United Kingdom
GEZE UK Ltd.
E-Mail: info.uk@geze.com
www.geze.com
GEZE GmbH
Reinhold-Vöster-Straße 21–29
71229 Leonberg
Germany
Tel.: 0049 7152 203 0
Fax: 0049 7152 203 310
www.geze.com
1 Safety instructions
To ensure personal safety, it is important to follow these
safety instructions. These instructions must be kept.
úBefore installation, read and observe the safety notes
for these components and the drive. Warranty claims
require proper mounting, installation and maintenance in
accordance with the manufacturer's specications.
úOnly appropriately qualied people may carry
out installation, commissioning and maintenance.
Unauthorised modications to the system release GEZE
from liability for any resulting damages.
úOnly use GEZE original parts for repair and service work.
úObserve the latest versions of guidelines, standards and
country-specic regulations.
úProtect the components of the GC173 from construction
dirt and water.
2 Brief description of wireless kit
The wireless kit is part of the GEZE hold-open system FA GC
150 or FA GC 160.
The wireless module GC 171, ID 163051, makes wireless com-
munication possible between the lintel-mounted smoke
switch and the various wireless devices.
úWireless ceiling-mounted smoke detector GC172 ID 195522
úWireless ceiling-mounted thermal detector GC173 ID 195523
úWireless input module GC 175, ID 163068 (for the connection of
manual trigger switches or contacts for the re alarm system)
3.2 Technical data
Wireless ceiling-mounted thermal
detector GC173 comprising: ID 195523
úBase GC170 B
úWireless thermal detector GC003 F
úTwo batteries
Battery type CR 123A (3 V DC)
Colour White, RAL 9016
Dimensions (with base, Ø × H) 110 mm × 65 mm
Functional principle Alarm if the ambient temperature exceeds the alarm temperature or if the ambient temperature
increases very quickly, no alarm saving (self-resetting as soon as the ambient temperature has
dropped again)
Alarm temperature 57°C
EN 54-5 classication A1R
Installation position Ceiling mounting
IP rating (in accordance with EN
60529) IP20, only for dry areas
Relative humidity 95% (non-condensing)
Ambient temperature -10 °C to 55 °C
Detector test To activate test mode:
XMove the test magnet near to the magnetic sensor (GEZE logo).
The LED ashes green.
Alarm triggering:
XMove the test magnet near to the magnetic sensor (GEZE logo) again.
XTrigger the alarm using the heat detector testing device.
The detector test using a test magnet tests the electrical components. The detector test which
forms part of the regular testing of the hold-open system must be carried out using a heat
detector testing device.
Battery life span 8 years
Signal transfer period 60 s
Antenna Integrated
Frequency range 868.15 MHz to 869.85 MHz
Range 10 m (100 m in space)
Number of frequency channels 7
Modulation technique FSK (frequency shift keying)
Radiated power 10 dBm / 10 mW
1
2
3
6
7
8
60
4 5
1 Magnetic sensor for testing (behind the GEZE logo)
2 LED for displaying state
3 Battery compartment cover
4 Battery compartment
5 Batteries
6 Set-up switch
7 Sabotage contact
8 Base
3 Wireless ceiling-mounted thermal
detector GC173
3.1 Use
The GC173 is a wireless ceiling-mounted thermal detector for
use in the GEZE hold-open system FA GC150 or FAGC160.
Signal transfer from the detector takes place wirelessly.
A wireless module GC171 is essential for use of the
wireless ceiling-mounted thermal detector GC173.
Thermal detectors measure the ambient temperature and
respond if the temperature exceeds a certain maximum
value or increases quickly within a certain time.
Usually, smoke and re gases spread quickly when a re
breaks out. It is only later that the temperature increases.
As far as possible, smoke detectors should generally be
used for hold-open systems. In areas where disruption such
as steam, dust, condensation or operation-related smoke
development (workshops, kitchens) occurs, it may, however,
be sensible to use thermal detectors rather than smoke
detectors.
German
institute for
construction
technology
Smoke detectors must be used for hold-
open systems for closers on rescue routes.
Heed the document for the hold-open system FA GC 150 or
FA GC 160 - Instructions for the installation, commissioning,
operation and maintenance - see www.geze.com.
Set up wireless connection
XSlide a free wireless device switch SW1x of the wireless module GC171 to the ON
position.
The corresponding wireless device LED1x starts to ash green. If a connection has
already been set up for the wireless device switch selected, this is overwritten by the
following process. The wireless module GC171 waits for the connection query for
a new wireless device.
If a new wireless device does not respond within 2 minutes, the wireless module GC171
cancels the connection attempt, the corresponding wireless device LED1x lights up red.
XTo start the connection attempt again, slide the corresponding wireless device
switch SW1x to the OFF position briey, then slide it back into the ON position.
The corresponding wireless device LED1x now ashes green again for 2 minutes.
LED1x
SW1x
Install batteries
XRemove the protective lms from the battery compartment (4) of the new wireless
detector and install the batteries (5) in the new wireless detector. Make sure of
correct polarity.


The LED (2) on the new wireless ceiling-mounted detector ashes green twice rst,
then lights up orange for one second and then ashes red four times.
As soon as the LED (2) goes out after that, the connection can be set up.
2
XSlide the set-up switch (6) on the new wireless detector to the 1 position.
After a short time, the LED of the new wireless detector will ash green for a few seconds.
The corresponding wireless device LED1x of the wireless module GC171 lights up green
permanently.

If the LED (2) on the new wireless detector lights up red permanently, no connection
has been made.
XIn this case, remove the batteries from the new wireless detector, slide the set-up
switch (6) on the new wireless detector back and forward six times and install the
batteries (5) again. Continue as described above.
XFit the wireless ceiling-mounted thermal detector to the base (8).
XSlide the wireless device switch SW1x of the wireless module GC171 to the OFF
position again.
The colour the corresponding wireless device LED1x ashes indicates the quality of the
wireless connection (see connection quality).
XOptimise the quality of the wireless connection if necessary by changing the position
of the wireless detector.
LED1x
SW1x
The connection of the wireless module GC171 to the new wireless detector has been
set up.
XNote the set-up connection (the number of the assigned wireless device switch)
onto the identication plate of the new wireless detector.
XTo set up further wireless connections, continue with step “Set up wireless connection”.
XPress the PB1 push button on the wireless module GC171 briey to change to the
“operating” mode.
The status LED2 of the wireless module GC171 goes o.
1
2
3
4
KL1 SW1 LED1
24V
GND
MRB
AS
1
2
3
4
LED2
PB1 SW2
GC161 GC151
KL1 SW1 LED1
24V
GND
MRB
AS
1
2
3
4
LED2
PB1 SW2
GC161 GC151
EN 54-5*
EN 54-25*
EN 14637**
German
institute for
construction
technology
* EN 54-5 and EN 54-25 certied by BRE Global Ireland only with the GC171_L gateway (see document L20-GC171_-0001_REV_A.1).
** EN 14637 certied by KRIWAN with GC 172, GC 173, GC 175 and GC171 gateway.
3.3 Signalling
State, event LED for displaying state
Switch on lights up green for 1 s, then repeated red
Start set-up of the wireless connection ashes green until the wireless connection is established
Fault during set-up of the wireless connection lights up red
Operation o
Alarm ashes red (0.5s on – 0.5s o)
Battery 1 discharged ashes orange (0.1s on – 5s o)
Battery 2 discharged ashes green (0.1s on – 5s o)
Both batteries discharged ashes orange/green alternately (0.1s on – 5s o)
Other faults ashes orange/green alternately (0.5s each)
Manipulation o
Loss of connection o
Test mode – the detector reacts sensitively to heat ashes green every second for 1 minute
3.4 Battery replacement
The wireless detector signals “low battery charge” to the wireless module GC171 if the charge state of the batteries
is no longer
sucient. Both batteries (5) always have to be replaced together. The set-up switch (6) for the wireless detector must not be activated.
XTake the wireless detector out of the base (8).
XRemove the battery compartment cover (3).
XRemove both batteries (5).
XInsert new batteries (type CR123A) – make sure polarity is correct.
XReplace the battery compartment cover (3).
XInsert the wireless detector into the base (8).
XTest the wireless detector. It can take up to a minute for the wireless detector to be ready for operation after battery replacement.
3.5 Connecting the wireless ceiling-mounted thermal detector GC173 to wireless module GC171
A maximum of 6 wireless connections can be set up at one wireless module GC171.
Pre-conditions
úAll the wireless device switches of the wireless module GC171 are in the OFF position.
SW1x
úThe set-up switch (6) of the new wireless detector is set to the ON position.

úThe protective lms are on the battery compartment of the new wireless detector
and the batteries for the new wireless detector have not been tted.
Set up a new wireless connection
XSwitch the supply voltage for the wireless module GC171 on.
The wireless module is in “operating” mode.
XPress the PB1 push button on the wireless module GC171 briey to change to the
“set up wireless connection” mode. The status LED2 of the wireless module GC171
now lights up red permanently.
1
2
3
4
KL1 SW1 LED1
24V
GND
MRB
AS
1
2
3
4
LED2
PB1
SW2
GC161 GC151
KL1 SW1 LED1
24V
GND
MRB
AS
1
2
3
4
LED2
PB1 SW2
GC161 GC151
GEZE GmbH hereby declares that the components of the wireless kit for hold-open systems complies with the Directives
2014/53/EU and 2011/65/EU. The complete text of the EU Declaration of Conformity, and the Declaration of Performance, is
available at the following internet address: www.geze.com

Other GEZE Security Sensor manuals

GEZE GC 334 User manual

GEZE

GEZE GC 334 User manual

GEZE GC 365 R User manual

GEZE

GEZE GC 365 R User manual

GEZE GC 173 User manual

GEZE

GEZE GC 173 User manual

GEZE GC 363 R User manual

GEZE

GEZE GC 363 R User manual

GEZE GC 304 R User manual

GEZE

GEZE GC 304 R User manual

GEZE GC 333 C User manual

GEZE

GEZE GC 333 C User manual

GEZE SecuLogic RWS TZ 300 Operator's manual

GEZE

GEZE SecuLogic RWS TZ 300 Operator's manual

GEZE GC 172 User manual

GEZE

GEZE GC 172 User manual

GEZE GC 307+ User manual

GEZE

GEZE GC 307+ User manual

GEZE GC 304 R User manual

GEZE

GEZE GC 304 R User manual

Popular Security Sensor manuals by other brands

Hi-Link HLK-LD1125H-24G Applications manual

Hi-Link

Hi-Link HLK-LD1125H-24G Applications manual

Abus AirSecure CO2WM110 user manual

Abus

Abus AirSecure CO2WM110 user manual

Alarmcom ADC-IS-300-LP installation guide

Alarmcom

Alarmcom ADC-IS-300-LP installation guide

Axio MET AX-T03 manual

Axio MET

Axio MET AX-T03 manual

C-SCOPE L2 Series instruction manual

C-SCOPE

C-SCOPE L2 Series instruction manual

wattstopper Legrand LMPX-100 quick start guide

wattstopper

wattstopper Legrand LMPX-100 quick start guide

HIK VISION DS-PD2-D12-W manual

HIK VISION

HIK VISION DS-PD2-D12-W manual

Maxouttech RF-SHK-319-NN quick start guide

Maxouttech

Maxouttech RF-SHK-319-NN quick start guide

HIK VISION AX PRO DS-PDC15-EG2-WE user manual

HIK VISION

HIK VISION AX PRO DS-PDC15-EG2-WE user manual

Paradox PMD75N installation manual

Paradox

Paradox PMD75N installation manual

HIK VISION DS-PDEB1-EG2-WB quick start guide

HIK VISION

HIK VISION DS-PDEB1-EG2-WB quick start guide

B-Link NANO SENSE instructions

B-Link

B-Link NANO SENSE instructions

q-Tech XLINE Series Installation and programming manual

q-Tech

q-Tech XLINE Series Installation and programming manual

Redline RAS-Extend M Installation guidelines

Redline

Redline RAS-Extend M Installation guidelines

Innohome Stove Guard SGK430 Reference manual

Innohome

Innohome Stove Guard SGK430 Reference manual

EPE Conseil CEMPROTEC 34 user guide

EPE Conseil

EPE Conseil CEMPROTEC 34 user guide

Paradox EB-N94 installation guide

Paradox

Paradox EB-N94 installation guide

C.P. Electronics MWS6-DD-LV installation guide

C.P. Electronics

C.P. Electronics MWS6-DD-LV installation guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.