manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. GEZE
  6. •
  7. Security Sensor
  8. •
  9. GEZE GC 333 C User manual

GEZE GC 333 C User manual

2
1
4
5
1
1
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
1
1
2
3
2
GEZE GmbH / Reinhold-Vöster-Straße 21-29 / 71229 Leonberg / Germany / Tel. ++49(0)7152-203-0 / Fax ++49(0)7152-203-310
GEZE hereby declares that the GC 333 C is in conformity with the basic requirements and the other relevant provisions of the
standards 2004/108/EC and 2006/42/EC.
Notified Body for EC inspection: 0044 - TÜV NORD CERT GmbH, Langemarckstr. 20, D-45141 Essen
LED-SIGNALS
The ORANGE LED
flashes 1 x.
The ORANGE LED
flashes 2 x.
The ORANGE LED
flashes 4 x.
The ORANGE LED
flashes 5 x.
The ORANGE LED
flashes every second.
The ORANGE LED
is on.
The RED LED flashes
quickly after an
assisted setup.
The RED LED
lights up
sporadically.
The LED is off.
The reaction of
the door does not
correspond to the
LED-signal.
The sensor goes into
security mode.
The sensor signals
an internal fault.
Irregularities in the
power supply
The sensor receives
not enough IR-energy.
The sensor receives
too much IR-energy.
The sensor encounters
a memory problem.
The sensor vibrates.
The sensor sees the door
during the assisted setup.
The sensor sees the door.
The sensor is disturbed
by the rain.
Check power supply.
Check wiring.
Check the angle of the IR-curtains.
Adapt background if necessary
(floor is too absorbing).
Launch a new assisted setup.
Cut and restore power supply.
Cut and restore power supply.
If orange LED lights up again, replace sensor.
Check the angle of the IR-curtains.
Launch a new assisted setup.
Attention: Do not stand in the detection field!
Check connections to test output.
If your door controller is not able to test the sensor,
connect the red and blue cable to power supply.*
Check output configuration setting.
Switch value 1 (P) to 2 (A) or 2 to 1 by remote
control.
Check the angle of the IR-curtains.
Adapt background if necessary
(floor is too reflective).
Check if the sensor is fastened firmly.
Check position of prism and cover.
Increase the IR-immunity filter by remote control.*
Launch an assisted setup and adjust the IR angle.
Cut and restore power supply.
If orange LED flashes again, replace sensor.
Only for EC countries: According the European Guideline 2002/96/EC for Waste Electrical and Electronic Equipment (WEEE)
SAFETY INSTRUCTIONS
The manufacturer of the door system is responsible for carrying out a risk assessment and installing the sensor and the door system
in compliance with applicable national and international regulations and standards on door safety and if applicable, the machinery
directive 2006/42/EC.
Only trained and qualified personnel may install and set-up the sensor.
The warranty is void if unauthorized repairs are made or attempted by unauthorized personnel.
Avoid touching any electronic and optical components.
*excludes DIN18650-conformity of the door equipment
O
ri
g
ina
l
instructions
|
4
2
.
0685
/
V
5
-
11.1
0
Leonberg, November 2010 Hermann Alber, Authorized representative
Id. No. 127109 Modification level 05 Drawing No. 70706-9-9502 Printed in Germany Subject to change without notice
2
1
3
4
5
E
R
L
A
U
B
T
Z
E
R
T
I
F
I
Z
I
E
R
U
N
G
N
A
C
H
DIN 18650
E
N
A
B
L
E
S
A
C
C
O
R
D
A
N
C
E
W
I
T
H
GC 333 C
TECHNICAL SPECIFICATIONS
1. IR-prism (50 cm RIGHT HIGH)
2. cover
DESCRIPTION
Presence
Typical response time: <128 ms (max. 500 ms)
Active infrared (wave length: 880 nm) with background analysis
Spot diameter: 0.1 m max.
Number of spots: 6 by curtain
Number of curtains: 1 or 2 (adjustable)
From -4 ° to +4 ° (adjustable)
Solid-state-relay (free of potential, free of polarity)
Max. contact current: 100 mA
Max. contact voltage: 42 V AC/DC
0.3 s or 1 s (not adjustable)
Typical: < 15 ms (max. 25 ms)
ENGLISH
Safety sensor
for automatic revolving doors
3. push buttons
4. IR-curtain ajustment screw
5. main connector
12 V - 24 V AC +/-10% ; 12 V - 30 V DC -5%/+10%
< 3 W
1.8 m to 2.7 m
< 1 V : Log. L; > 10 V: Log. H (max. 30 V)
-25 °C to +55 °C
IP54
EMC 2004/108/EC; MD 2006/42/EC
EN ISO 13849-1:2008 Performance Level «c» CAT. 2; EN 12978
(under the condition that the door control system monitors the sensor at least once per door cycle)
Supply voltage:
Power consumption:
Mounting height:
Sensitivity of the test input:
Temperature range:
Degree of protection:
Norm conformity:
Detection mode:
Technology:
Angle:
Output:
Hold-open time:
Response time on test request:
Other use of the device is outside the permitted purpose
and can not be guaranteed by the manufacturer.
The manufacturer cannot be held responsible for incorrect
installations or inappropriate adjustments of the sensor.
Speci
fi
cations are subject to changes without prior notice
.
M
easure
d
in optima
l
con
d
itions
.
For product version 0600 and more
Please keep for further use
Designed for colour printing
1
2
right
h
igh 50 right
high
50 cm
RIGHT HIGH
«click»
max 5 cm
50 cm
LEFT HIGH
5
L
50 left
high
GC 333 C
BN
GN
GY
PK
BU
RD
WH
YE
IR-Vorhang
125 mA
Test
-UB
+UB
COM
nicht belegt
nicht belegt
VPS116
1GND
2 24V
30 TST2
VPS1
VPS2
17
1GND
2 24V
30 TST2
VPS2
innerer
Vorderpfosten
äußerer
Vorderpfosten
24V
KI
siehe TIP
MOUNTING & WIRING
INFRARED FIELD
WIDTHANGLE
CLOSER
CLOSER
AWAY
AWAY
For compliance with DIN 18650 connection required to door controller test
output.
TIP: Launch an ASSISTED SETUP to verify wiring, position of the curtains and correct functioning of the sensor.
It is recommended to clean the optical parts at least once a year or more often if required due to
environmental conditions.
The door control unit and the door cover profile should be
correctly earthed. 12
3
4
GC 333 C
+
P-AP-P
A-PA-A
QUICK SETUP = ASSISTED SETUP* =
SETTINGS
SETUP (by push button or remote control)
NUMBER OF
CURTAINS
IMMUNITY FILTER
MAX. PRESENCE
TIME
TEST (MONITORING)
OUTPUT
CONFIGURATION
auto = the sensor will automatically adapt to the door controller:
on if testable, off if not testable
on auto
off
PUSH RIGHT UNTIL
FACTORY VALUES
1 DOOR
CYCLE
RED-GREEN OFF
RED-GREEN
30 s1 min 2 min 5 min 10 min 20 min 60 min
normal higher
high
RED-GREEN OFF
* Yellow and white cable have to be connected.
Please step out of the infrared field.
OUTPUT
REDIRECTION
excludes DIN18650-conformity
of the door equipment
IMPORTANT: Test the good functioning of the installation before leaving the premises.
OR
RESETTING TO
FACTORY VALUES
safety safety
+
opening
0 presence detection on safety input
1 presence detection on safety and opening input
A = active output (NO-contact)
P = passive output (NC-contact) Opening
Safety

Other GEZE Security Sensor manuals

GEZE GC 172 User manual

GEZE

GEZE GC 172 User manual

GEZE GC 173 User manual

GEZE

GEZE GC 173 User manual

GEZE GC 304 R User manual

GEZE

GEZE GC 304 R User manual

GEZE SecuLogic RWS TZ 300 Operator's manual

GEZE

GEZE SecuLogic RWS TZ 300 Operator's manual

GEZE GC 363 R User manual

GEZE

GEZE GC 363 R User manual

GEZE GC 173 User manual

GEZE

GEZE GC 173 User manual

GEZE GC 334 User manual

GEZE

GEZE GC 334 User manual

GEZE GC 307+ User manual

GEZE

GEZE GC 307+ User manual

GEZE GC 304 R User manual

GEZE

GEZE GC 304 R User manual

GEZE GC 365 R User manual

GEZE

GEZE GC 365 R User manual

Popular Security Sensor manuals by other brands

Hi-Link HLK-LD1125H-24G Applications manual

Hi-Link

Hi-Link HLK-LD1125H-24G Applications manual

Abus AirSecure CO2WM110 user manual

Abus

Abus AirSecure CO2WM110 user manual

Alarmcom ADC-IS-300-LP installation guide

Alarmcom

Alarmcom ADC-IS-300-LP installation guide

Axio MET AX-T03 manual

Axio MET

Axio MET AX-T03 manual

C-SCOPE L2 Series instruction manual

C-SCOPE

C-SCOPE L2 Series instruction manual

wattstopper Legrand LMPX-100 quick start guide

wattstopper

wattstopper Legrand LMPX-100 quick start guide

HIK VISION DS-PD2-D12-W manual

HIK VISION

HIK VISION DS-PD2-D12-W manual

Maxouttech RF-SHK-319-NN quick start guide

Maxouttech

Maxouttech RF-SHK-319-NN quick start guide

HIK VISION AX PRO DS-PDC15-EG2-WE user manual

HIK VISION

HIK VISION AX PRO DS-PDC15-EG2-WE user manual

Paradox PMD75N installation manual

Paradox

Paradox PMD75N installation manual

HIK VISION DS-PDEB1-EG2-WB quick start guide

HIK VISION

HIK VISION DS-PDEB1-EG2-WB quick start guide

B-Link NANO SENSE instructions

B-Link

B-Link NANO SENSE instructions

q-Tech XLINE Series Installation and programming manual

q-Tech

q-Tech XLINE Series Installation and programming manual

Redline RAS-Extend M Installation guidelines

Redline

Redline RAS-Extend M Installation guidelines

Innohome Stove Guard SGK430 Reference manual

Innohome

Innohome Stove Guard SGK430 Reference manual

EPE Conseil CEMPROTEC 34 user guide

EPE Conseil

EPE Conseil CEMPROTEC 34 user guide

Paradox EB-N94 installation guide

Paradox

Paradox EB-N94 installation guide

C.P. Electronics MWS6-DD-LV installation guide

C.P. Electronics

C.P. Electronics MWS6-DD-LV installation guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.