LED-SIGNALS
The ORANGE LED
flashes 1 x.
The ORANGE LED
flashes 2 x.
The ORANGE LED
flashes 4 x.
The ORANGE LED
flashes 5 x.
The ORANGE LED
flashes every second.
The ORANGE LED
is on.
The RED LED flashes
quickly after an
assisted setup.
The RED LED
lights up
sporadically.
The LED is off.
The reaction of
the door does not
correspond to the
LED-signal.
The sensor goes into
security mode.
The sensor signals
an internal fault.
Irregularities in the
power supply
The sensor receives
not enough IR-energy.
The sensor receives
too much IR-energy.
The sensor encounters
a memory problem.
The sensor vibrates.
The sensor sees the door
during the assisted setup.
The sensor sees the door.
The sensor is disturbed
by the rain.
Check power supply.
Check wiring.
Check the angle of the IR-curtains.
Adapt background if necessary
(floor is too absorbing).
Launch a new assisted setup.
Cut and restore power supply.
Cut and restore power supply.
If orange LED lights up again, replace sensor.
Check the angle of the IR-curtains.
Launch a new assisted setup.
Attention: Do not stand in the detection field!
Check connections to test output.
If your door controller is not able to test the sensor,
connect the red and blue cable to power supply.*
Check output configuration setting.
Switch value 1 (P) to 2 (A) or 2 to 1 by remote
control.
Check the angle of the IR-curtains.
Adapt background if necessary
(floor is too reflective).
Check if the sensor is fastened firmly.
Check position of prism and cover.
Increase the IR-immunity filter by remote control.*
Launch an assisted setup and adjust the IR angle.
Cut and restore power supply.
If orange LED flashes again, replace sensor.
Only for EC countries: According the European Guideline 2002/96/EC for Waste Electrical and Electronic Equipment (WEEE)
SAFETY INSTRUCTIONS
The manufacturer of the door system is responsible for carrying out a risk assessment and installing the sensor and the door system
in compliance with applicable national and international regulations and standards on door safety and if applicable, the machinery
directive 2006/42/EC.
Only trained and qualified personnel may install and set-up the sensor.
The warranty is void if unauthorized repairs are made or attempted by unauthorized personnel.
Avoid touching any electronic and optical components.
*excludes DIN18650-conformity of the door equipment
ri
ina
instructions
4
.
V
11.1
Leonberg, November 2010 Hermann Alber, Authorized representative
Id. No. 127109 Modification level 05 Drawing No. 70706-9-9502 Printed in Germany Subject to change without notice
2
1
3
4
5
E
R
L
A
U
B
T
Z
E
R
T
I
F
I
Z
I
E
R
U
N
G
N
A
C
H
DIN 18650
E
N
A
B
L
E
S
A
C
C
O
R
D
A
N
C
E
W
I
T
H
GC 333 C
TECHNICAL SPECIFICATIONS
1. IR-prism (50 cm RIGHT HIGH)
2. cover
DESCRIPTION
Presence
Typical response time: <128 ms (max. 500 ms)
Active infrared (wave length: 880 nm) with background analysis
Spot diameter: 0.1 m max.
Number of spots: 6 by curtain
Number of curtains: 1 or 2 (adjustable)
From -4 ° to +4 ° (adjustable)
Solid-state-relay (free of potential, free of polarity)
Max. contact current: 100 mA
Max. contact voltage: 42 V AC/DC
0.3 s or 1 s (not adjustable)
Typical: < 15 ms (max. 25 ms)
ENGLISH
Safety sensor
for automatic revolving doors
3. push buttons
4. IR-curtain ajustment screw
5. main connector
12 V - 24 V AC +/-10% ; 12 V - 30 V DC -5%/+10%
< 3 W
1.8 m to 2.7 m
< 1 V : Log. L; > 10 V: Log. H (max. 30 V)
-25 °C to +55 °C
IP54
EMC 2004/108/EC; MD 2006/42/EC
EN ISO 13849-1:2008 Performance Level «c» CAT. 2; EN 12978
(under the condition that the door control system monitors the sensor at least once per door cycle)
Supply voltage:
Power consumption:
Mounting height:
Sensitivity of the test input:
Temperature range:
Degree of protection:
Norm conformity:
Detection mode:
Technology:
Angle:
Output:
Hold-open time:
Response time on test request:
Other use of the device is outside the permitted purpose
and can not be guaranteed by the manufacturer.
The manufacturer cannot be held responsible for incorrect
installations or inappropriate adjustments of the sensor.
Speci
cations are subject to changes without prior notice
easure
in optima
con
itions
For product version 0600 and more
Please keep for further use
Designed for colour printing