manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Greenheck
  6. •
  7. Fire And Smoke Damper
  8. •
  9. Greenheck Vektor-M Series User manual

Greenheck Vektor-M Series User manual

Greenheck’s bypass air dampers and isolation dampers are designed to provide superior
airflow control in severe environments.
System dampers are designed and sized for specified application pressure and flow requirements. Both isolation
and/or bypass air dampers on Vektor systems are available with factory-mounted and wired electric actuators.
Each actuator is selected and sized to handle the specific torque requirements of the laboratory application.
Greenheck Advantages:
• Bypass air dampers are custom selected for each system static pressure and flow
• Structurally rigid, airfoil formed steel blades are corrosion-resistant coated steel, formed to operate against
high static pressures
• Damper shaft, bearings, and jamb seals are 316 SS
• All non-stainless components have a polyester resin powder coating, electrostatically applied and baked at
400ºF. (Standard on isolation dampers, optional on bypass air dampers).
• Damper and drive linkage is factory set and welded to prevent mechanical slippage. Linkage and operators
are outside of the hazardous/corrosive exhaust.
• Bypass air dampers use opposed blades for accurate flow control. Isolation dampers maintain plenum
containment using tight shut-off parallel blades.
• Industrial isolation and bypass air dampers are manufactured by Greenheck Fan Corporation, Schofield,
Wisconsin USA
Isolation & Bypass
Dampers and Controls
for Vektor Laboratory Exhaust
Vektor-M Series Bypass Air Plenum
and Roof Curb
Vektor-C Series Bypass Air Plenum
and Roof Curb
April
2018
Vektor Isolation Dampers Features and Options Vektor-M Series Vektor-C Series
Standard Construction Material (Frame, Blade) Galv. Steel Galv. Steel
Stainless Steel Construction Material (Frame, Blade) Optional Optional
Hi-Pro Polyester Coating Yes Yes
Blade Style Airfoil Airfoil
Electric Actuator Optional Optional
Greenheck isolation dampers are designed to prevent air leakage into the system when the fans operate in
“stand-by” mode or the system is off. Isolation dampers are two-position actuated as standard (provided with
electric actuators as an option), or can be provided as gravity backdraft (please consult the factory).
Isolation dampers are factory installed and shipped with the bypass
air plenum as an assembly; constant volume systems (no bypass
air plenum) may have curb mounted isolation dampers
Standard isolation damper construction includes a polyester resin
powder coated and baked, heavy-gauge steel formed casing and airfoil
blades. Jamb seals, bearing and blade shafts are stainless steel.
Isolation dampers can be removed by detaching the cover (Vektor-M)
or by removing the compact square-to-round transition (Vektor-C)
without accessing the contaminated interior of the bypass air plenum
Shaft extensions are provided for all actuators. Actuators can be
factory-mounted.
Isolation dampers use parallel airfoil damper blades
Damper linkage and optional actuator are located
outside the exhaust airstream and protected
by a weatherproof cover
4
3
2
5
6
1
6
5
4
3
1
2
Isolation Dampers
Greenheck’s bypass air dampers mix ambient air with exhaust air from the laboratory space. On variable
volume lab exhaust systems, bypass air damper modulation allows reduction in lab exhaust flow while
maintaining constant fan discharge flow rate, velocity, and plume rise.
A weatherhood with the stainless steel
birdscreen protects the bypass damper,
actuator and damper controls from the
ambient elements. Damper actuators
and controls are mounted outside of the
contaminated exhaust allowing servicing
without accessing the contaminated
plenum interior.
Bypass dampers utilize opposed blades for
flow control and are sized for each unique
system application. Construction includes
a polyester resin coated and baked, heavy-
gauge steel formed casing and airfoil
blades. Jamb seals, bearing and blade
shafts are stainless steel. Damper blade
edge seals are silicone.
Bypass dampers are available with
optional factory-mounted electric
modulating or pneumatic actuators.
Vektor Bypass Damper Features and Options Vektor-M Series Vektor-C Series
Standard Construction Material (Frame, Blade) Galv. Steel Galv. Steel
Stainless Steel Construction Material (Frame, Blade) Optional Optional
Hi-Pro Polyester Coating Optional Optional
Blade Style Airfoil Airfoil
Electric Actuator Optional Optional
1
3
2
1
23
Bypass Air
Damper
Isolation Damper
Bypass Air Plenum
Lab Exhaust
(Horizontal Intake)
Lab Exhaust
(Vertical Intake)
Bypass Air
What Does Bypass Air Do?
As the lab exhaust flow requirement
diminishes, the bypass air damper opens,
reducing the lab exhaust flow and adding
ambient air to the reduced lab exhaust
flow. The added bypass air assists in the
dispersion of hazardous lab effluent while
maintaining constant fan discharge flow,
velocity, and plume rise.
When the lab exhaust flow requirement
increases, the bypass air damper closes
and reduces the amount of added
ambient air to the increased lab exhaust.
Bypass air dampers are typically
controlled with modulating actuators tied
into the laboratory control system.
Bypass Air Dampers and Weatherhoods
Vektor lab exhaust isolation and bypass air dampers are available with factory-mounted electric or pneumatic
actuators to expedite system installation and to contribute to a safe, operational lab system.
Isolation Damper Actuator Options
• 2-position spring return actuator with end switches
• Electric actuators in 230 VAC, 115 VAC, 24 VAC, or 24 VDC are
mounted and wired with transformer
• Single point wiring of the transformer and actuator
• NEMA-1 enclosure (NEMA-4 enclosure optional)
Bypass Damper Actuator Options
• Modulating operation for bypass airflow control
• Electronic actuators in 230 VAC, 115 VAC, 24 VAC, or 24 VDC
(transformers optional)
• NEMA-1 enclosure (NEMA-4 enclosure optional)
Isolation Damper Actuator
and Transformer
Bypass Damper Actuator
Prepared to Support
Green Building Efforts
Family of Lab Exhaust Systems
Vektor®-MHVektor®-H
Vektor®-CS
Vektor®-CD
Vektor®-MD
Vektor®-MS
Vektor®-HS
Our Commitment
As a result of our commitment to continuous improvement, Greenheck reserves the right to change
specifications without notice.
Specific Greenheck product warranties are located on greenheck.com within the product
area tabs and in the Library under Warranties.
P.O. Box 410 • Schofield, WI 54476-0410 • Phone (715) 359-6171 • greenheck.com
Damper Controls
Copyright © 2018 Greenheck Fan Corp. • 00.LAB.1006 R2 4-2018 RG
Vektor®-CH

This manual suits for next models

1

Other Greenheck Fire And Smoke Damper manuals

Greenheck FSDR Series Installation and operating instructions

Greenheck

Greenheck FSDR Series Installation and operating instructions

Greenheck HTD Series User manual

Greenheck

Greenheck HTD Series User manual

Greenheck HPR Series User manual

Greenheck

Greenheck HPR Series User manual

Greenheck RBDR Series User manual

Greenheck

Greenheck RBDR Series User manual

Greenheck RBD Series User manual

Greenheck

Greenheck RBD Series User manual

Greenheck FSD Series Owner's manual

Greenheck

Greenheck FSD Series Owner's manual

Greenheck DFD Series User manual

Greenheck

Greenheck DFD Series User manual

Greenheck CRD-300WT User manual

Greenheck

Greenheck CRD-300WT User manual

Greenheck VCD Series User manual

Greenheck

Greenheck VCD Series User manual

Greenheck SMD Series User manual

Greenheck

Greenheck SMD Series User manual

Greenheck HBS Series Manual

Greenheck

Greenheck HBS Series Manual

Greenheck CRD-300WT User manual

Greenheck

Greenheck CRD-300WT User manual

Greenheck DFD Series User manual

Greenheck

Greenheck DFD Series User manual

Greenheck CFSD Series User manual

Greenheck

Greenheck CFSD Series User manual

Greenheck ES Series User manual

Greenheck

Greenheck ES Series User manual

Greenheck ESK-402 Installation and operating instructions

Greenheck

Greenheck ESK-402 Installation and operating instructions

Greenheck FD 150 Series User manual

Greenheck

Greenheck FD 150 Series User manual

Greenheck FSDR Series User manual

Greenheck

Greenheck FSDR Series User manual

Greenheck FSD Series Owner's manual

Greenheck

Greenheck FSD Series Owner's manual

Greenheck HSD-401 Manual

Greenheck

Greenheck HSD-401 Manual

Greenheck Vektor-MD User manual

Greenheck

Greenheck Vektor-MD User manual

Greenheck MBD-15 User manual

Greenheck

Greenheck MBD-15 User manual

Greenheck EHH-401 User manual

Greenheck

Greenheck EHH-401 User manual

Greenheck HBT Series User manual

Greenheck

Greenheck HBT Series User manual

Popular Fire And Smoke Damper manuals by other brands

mercor mcr EXi-F Operation and maintenance manual

mercor

mercor mcr EXi-F Operation and maintenance manual

VPro WT Series instruction manual

VPro

VPro WT Series instruction manual

NCA HVC 100 Series installation guide

NCA

NCA HVC 100 Series installation guide

SUGATSUNE Lapcon LAMP HG-JH installation manual

SUGATSUNE

SUGATSUNE Lapcon LAMP HG-JH installation manual

Trox Technik FKR-EU Installation and operating manual

Trox Technik

Trox Technik FKR-EU Installation and operating manual

CARNES EFOA Installation, operation and maintenance instructions

CARNES

CARNES EFOA Installation, operation and maintenance instructions

Exhausto VEX40T Assembly instruction

Exhausto

Exhausto VEX40T Assembly instruction

KOOLAIR SAFEAIR BDK60 Technical documentation

KOOLAIR

KOOLAIR SAFEAIR BDK60 Technical documentation

mercor mcr LAM Operation and maintenance manual

mercor

mercor mcr LAM Operation and maintenance manual

SOLID AIR FDC2 Technical manual

SOLID AIR

SOLID AIR FDC2 Technical manual

Ideal Heating EVOMAX 2 40 Installation

Ideal Heating

Ideal Heating EVOMAX 2 40 Installation

Price FD-RD installation instructions

Price

Price FD-RD installation instructions

klimaoprema FD25 product manual

klimaoprema

klimaoprema FD25 product manual

Johnson Controls FD-1300 Installation

Johnson Controls

Johnson Controls FD-1300 Installation

KOOLAIR FDS-3G Series manual

KOOLAIR

KOOLAIR FDS-3G Series manual

Rf-t CA2 installation manual

Rf-t

Rf-t CA2 installation manual

Advanced Air AIR CONTROL 0400FME Installation, operation and maintenance manual

Advanced Air

Advanced Air AIR CONTROL 0400FME Installation, operation and maintenance manual

Advanced Air 2530 CE Series manual

Advanced Air

Advanced Air 2530 CE Series manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.