Grizzl-E Smart Connect Classic Installation and operating instructions

GRIZZL E ™
SMART
EV Charger
Grizzl-E Connect
User Manual
& Installation Guide

2
Grizzl-E Smart Connect Manual
Model Numbers:
Classic
GRS-14-24-P
GRS-6-24-P
Avalanche Edition
GRS-14-24-AB
GRS-6-24-AB
Extreme Edition
GRS-14-24-PC
Grizzl-E Smart Connect Version 2: All units manufactured after July 5, 2023*.
Manual Revision: 2.0
*Check the MFG Date on the label. If the MFG date is
before 2023/07/05, see Version 1 ChargeLab Manual.

3
Grizzl-E Smart Home EV Charging Station
The Grizzl-E Smart is the Wi-Fi connected smart EV Charger built from the proven Grizzl-E
design. Grizzl-E Smart has Wi-Fi connectivity to work with the Grizzl-E Connect application. It is
a simple, powerful, heavy-duty, and portable electric vehicle charging station made in Canada
and built to withstand the harshest conditions.
The Grizzl-E Smart comes exclusively with a 24ft Premium cable. Internal design and
components of the charger have been selected to provide maximum operational life of the
device and be able to withstand the elements.
Grizzl-E Smart provides up to 10kW of power to a BEV or PHEV. Maximum current output can
be set through DIP Switches to provide 16 Amps, 24 Amps, 32Amps or 40 Amps adjustable
maximum current.
IMPORTANT SAFETY INSTRUCTIONS
This document contains instructions and warnings that must be followed when installing and
using the Grizzl-E Smart Electric Vehicle Supply Equipment (EVSE). Before installing or using
the EVSE, read this document including any WARNING and CAUTION symbols.
The Symbols Used Have the Following Meanings
Warning: risk of personal injury Warning: risk of fire
Warning: risk of electric shock Caution: risk of damage to equipment
• This document provides instructions for the charging station and should not be used for
any other product. Before installation or use of this product, review this manual carefully
and consult with a licensed contractor, licensed electrician, or trained installation expert to
ensure compliance with local building codes and safety standards.
• Consult a licensed electrician to ensure that this product can be safely installed and used.
• Ensure that the materials used, and the installation procedures, follow local building codes
and safety standards.
• The information provided in this manual in no way exempts the user of responsibility to
follow all applicable codes or safety standards.

4
Basic precautions should always be followed when using electrical products, including the
following:
• Read all the instructions before using this product.
• Children should not use this device.
• Do not put fingers into the EV connector.
• Do not touch live electrical parts.
• Do not use this product if the flexible power cord or EV cable is ragged, has broken
insulation, or any other signs of damage.
• Do not use this product if the enclosure or the EV connector is broken, cracked, open,
or shows any other indication of damage.
• To avoid a risk of fire or electric shock, do not use this device with an extension cord or
electrical adapter.
• Improper connection of the equipment grounding conductor can result in a risk of electric
shock. Check with a licensed electrician if there are doubts as to whether the product is
properly connected and grounded.
Repair and Maintenance Clause
• All United Chargers products do not require routine maintenance however, periodic
inspections should be conducted to ensure that all parts remain in good working order
and no damage exists.
• Do not attempt to disassemble, repair, tamper with, or modify any components of the
products. Contact United Chargers for any repairs.
WARNING: This equipment is intended only for charging vehicles
that do not require ventilation during charging. Please refer to the
vehicle’s owner’s manual to determine ventilation requirements.

5
Product Specifications
Description Specifications
Model Numbers GRS-14-24-PB GRS-14-24-AB GRS-14-24-PC
GRS-6-24-PB GRS-6-24-AB
EVSE Level SAE J1772; AC Level 2
Max Output
Rating 40A; 9.6 kW Maximum Output – For use with 50A Circuit Rating
Alternate
Adjustable Output
Ratings
32A; 7.68 kW Maximum Output – For use with 40A Circuit Rating
24A; 5.76 kW Maximum Output – For use with 30A Circuit Rating
16A; 3.84 kW Maximum Output – For use with 20A Circuit Rating
Charge Cable Length 24 ft.
Electrical Circuit
/ Input Power
Requirements
Circuit Requirement: Dedicated Single Phase 208 or Split Phase
240VAC, 50/60 Hz.; Branch Breaker: Double pole;
Circuit Conductors: Line 1, Line 2, Earth / Ground
Input Power
Connection
Standard: Plug-in, NEMA 6-50 or NEMA 14-50 Plug.
Plug is removable for Hardwire Connection.
Installation Rating NEMA 4X, Indoor/Outdoor Rated
Operational Ratings Temperature: -22⁰F to 122⁰F (-30⁰C to 50⁰C);
Humidity: 95% RH non-condensing
Overall Dimensions EVSE: 10.25 x 6.25 x 3.75 inches (26.0 x 16.0 x 9.3 cm)
Overall Weight 21lbs (9.5kg)
Display & Indicators LED Charge Status Indicators (Power/Ready, Charging, Fault)
Connectivity 2.4Ghz Wi-Fi network
Standards &
Compliance UL Certified E510712, Energy Star Certified 2378449

6
Table of Contents
1. Introduction & Unpacking ................................................................................................7
1.1 Your Charger.................................................................................................................. 7
1.2 Package Contents.......................................................................................................... 8
2. Installation Planning and Service Wiring: .......................................................................9
2.1 Electrical Source Requirements .................................................................................. 9
2.2 Grounding Instructions ............................................................................................... 9
3. Adjustable Maximum Current Output ...........................................................................10
3.1 Adjust Maximum Current Output ............................................................................. 10
4. Installation ........................................................................................................................13
4.1 Tools & Parts Required for Installation .................................................................... 13
4.2 Install the Charging Station ....................................................................................... 14
5. Wiring Connection ............................................................................................................17
5.1 Optional Hardwire Connection................................................................................. 17
5.2 Replace Output Cable ................................................................................................ 19
6. EasyEvPlug Holster and Cable Management System....................................................20
7. Charging Status Indicators and Buzzers ........................................................................21
7.1 Charging Status Indicators ........................................................................................ 21
7.2 Fault Indicators ........................................................................................................... 22
7.3 Self-Monitoring and Recovery (Auto Restart) .........................................................22
7.4 Reset Charger .............................................................................................................. 22
8. Set Up Smart Functionality..............................................................................................23
8.1 Network Requirements .............................................................................................. 23
8.2 Connect the Grizzl-E to Wi-Fi...................................................................................... 23
8.3 Change W-Fi Network ................................................................................................. 24
8.4 Troubleshoot Connection Errors.............................................................................. 25
9. Station Wi-Fi Network ......................................................................................................26
9.1 Change Station Wi-Fi Password................................................................................. 26
9.2 Reset Wi-Fi.................................................................................................................... 27
10. Operation ........................................................................................................................28
10.1 Connect and Charge ................................................................................................ 28
10.2 Smart Charging ......................................................................................................... 28
10.3 Stop Charging ........................................................................................................... 28
11. General Product Care and Use Information ...............................................................29
12. Warranty .........................................................................................................................30

7
1.1 Your Charger
Charger Components
1. Input Cable NEMA 14-50P or NEMA 6-50P
2. Output Cable J1772 Connector
3. Latch Release Button
4. Indicator Light
1
4
2
3
1. Introduction & Unpacking

8
1.2 Package Contents
Mounting Bracket (x1)
Security Pin (x1)
Front Plate
Screw (x4)
Back Plate
Screws (x2)
Holster (x1)
Holster
Anchor (x4)
Holster
Screws (x4)
Mounting Kit
EasyEvPlug Holster

9
2. Installation Planning and Service Wiring:
WARNING: Disconnect the power supply to the charging station
before installing, adjusting, or repairing the charging. Failure to do so
may result in physical injury or damage to the power supply system
and the charging station.
CAUTION: To reduce the risk of fire, connect only to a circuit provided
with the minimum branch circuit overcurrent protection requirements
in accordance with the National Electrical Code ANSI/NFPA 7- and the
Canadian Electrical Safety Code, Part 1, C22.1. If unsure if the circuit
meets these requirements consult a licensed electrician.
2.1 Electrical Source Requirements
• Prior to mounting, locate an available electrical source that can support the following
Input Requirements for the Charging Station Per local Electrical Safety Code requirements:
»40A Maximum Output Setting (Default Factory Setting): a DEDICATED CIRCUIT rated
for 50A; 208VAC Single Phase or 240VAC Split Phase, 50-60 Hz,
»32A Maximum Output Setting (Default Factory Setting): a DEDICATED CIRCUIT rated
for 40A; 208VAC Single Phase or 240VAC Split Phase, 50-60 Hz,
»24A Maximum Output Setting (Default Factory Setting): a DEDICATED CIRCUIT rated
for 30A; 208VAC Single Phase or 240VAC Split Phase, 50-60 Hz,
»16A Maximum Output Setting (Default Factory Setting): a DEDICATED CIRCUIT rated
for 20A; 208VAC Single Phase or 240VAC Split Phase, 50-60 Hz, A Double Pole Circuit
Breaker of the circuit rating must be used.
»The Charging Unit has a built in GFCI protection. Additional GFCI protection upstream
of the charging unit is not necessary. In locations where GFCI at the outlet is mandated
by code, the charger will not experience negative effects.
• The Charging Stations can connect a Standard NEMA 14-50, NEMA 6-50 Receptacle, or the
unit can be hardwired.
• It is recommended to use Grizzl-E Chargers with a Circuit Breaker. It is not recommended
to use a Fuse Box as this can lead to unexpected blown fuses.
2.2 Grounding Instructions
The charging station must be grounded through a permanent wiring system or an equipment
grounding conductor. Use a cable with a dedicated grounding conductor connected to the
equipment ground terminal block.

10
3. Adjustable Maximum Current Output
The GRIZZL-E Smart charging station features the ability to adjust the maximum Charging
Station current output to support 50A, 40A, 30A, or 20A Dedicated Circuit ratings as follows:
Circuit Rating Maximum Charging Station Output
50A 40A (9.6 kW)
40A 32A (7.68 kW)
30A 24A (5.76 kW)
20A 16A (3.84 kW)
• The Charging Station Default Factory Maximum Current Output Setting is 40A (9.6 kW) for
use with a 50A Circuit Rating.
• The Circuit must be a DEDICATED CIRCUIT 208-240 VAC, 50-60 Hz.
• Requirements govern that only 80% of the circuit rated load may be utilized, hence the
higher Circuit Ratings Requirement relative to maximum Charging Station output.
3.1 Adjust Maximum Current Output
To adjust the Maximum Current Output Setting:
1. Remove the front cover by removing the 4 screws at each corner of the charging station.
Use a M4 Allen Key to remove the screws.

11
CAUTION: The LED pipe is attached to the front cover. When the
front cover is removed, place it on a flat surface facing down to avoid
damage to the LED pipe.
2. With the front cover placed to the side, locate the DIP switch on the charging station circuit
board. The DIP switch is a 4-position switch on the main circuit board, located near the LED.
UP UP UP DOWN
WARNING: Do not touch live electrical parts. Disconnect the power
supply to the charging station and verify no power is present before
adjusting the DIP Switches. Failure to do so may result in physical
injury or damage to the power supply system and the charging station.

12
3. Adjust the Maximum Current Output to either 40A, 32A, 24A or 16A, using the following
combination of DIP switch settings:
Maximum Current Output Switch 1 Switch 2 Switch 3 Switch 4 DIP Switch Setting
40A Maximum Current Output
(Factory Default Setting) UP UP UP DOWN
32A Maximum Current Output UP DOWN UP DOWN
24A Maximum Current Output UP UP DOWN DOWN
16A Maximum Current Output UP DOWN DOWN DOWN
4. Once the DIP Switch Setting is adjusted, reassemble the charging station. Reinstall the top
cover to the charging station using the following torque force to secure the 4 socket cap
screws:
Screw Torque
5/32” 13.88 lbf-in (1.56Nm)

13
4. Installation
Prior to mounting, determine the location of an acceptable mounting support. All charging
station products must be anchored into a mounting support such as a 2” x 4” stud or a solid
concrete wall. DO NOT mount this unit directly to a stucco/drywall/wall board.
4.1 Tools & Parts Required for Installation
Tool Size Source of Supply Remark
Mounting Bracket 255 x148
x 36 mm Included with Product For mounting the charging
station to the wall/structure
Front Plate
screws (x4) 5/16” Included with Product
For securing the charging
station to the Mounting
Bracket
Back Plate
Screws (x2) #14 Included with Product For installing the Mounting
Bracket to the wall/structure
EasyEvPlug™
Holster/Tesla Holster Included with Product To store the EV charging Plug
and Cable
Holster
Screw (x4) #8 Included with Product
For installing the
EasyEvPlug™to the wall/
structure
Anchors
(x4) #8 Included with Product
For installing the
EasyEvPlug™to the wall/
structure
Philips Screwdriver PH3 Commercially
Available
For optional
Hardwire Install
Allen key 5/32” Commercially
Available
For Charging Station Cover
Screws
Allen key 3/16” Commercially
Available
For installing the enclosure
plate to the back of the
station body.

14
4.2 Install the Charging Station
1. Separate the front and back piece of the mounting bracket by pushing down on the
notch.
Front Piece
Back Piece
2. Attach the front piece of the mounting bracket to the back of the charging station
using the Front Plate screws. Ensure the top of the mounting bracket is matched with
the top of the charging station.
TOP

15
3. Secure the back piece of the mounting bracket to the wall or other suitable structure using
the Back Plate screws.
The back piece of the mounting bracket has 3 holes to support attachment to various
surfaces. Use the top two holes to attach the mounting bracket to a wall stud.
Mounting Screw Recommendations:
• For finished walls supported by wood studs, use #14 or M6 tapping screws. (Included).
• For masonry walls, use M6 mechanical screws. (Commercially available)
• Use following torque force:
Screw Torque
M6 43.4 lbf-in 44.85Nm
1/4” 43.4 lbf-in
Mount the unit at least 18in (460mm) above floor level. The charging station should be less
than 24in (610mm) from the NEMA outlet. The NEMA outlet should be located in compliance
with all applicable local electrical safety codes and standards.
44.85Nm

16
4. Mount the charger on the wall by securing the front piece of the mounting bracket to the
back piece of the mounting bracket.
5. Secure the charger in place by inserting either the security pin or the outdoor security lock
into the mounting bracket.
6. Plug in the power cord to the NEMA 14-50 or NEMA 6-50 Wall Outlet/Receptacle. Ensure
the indicator light is Magenta, indicating the charger is ready and not connected to the
Wi-Fi network.

17
5. Wiring Connection
1. Choose the appropriate conduit in accordance with all applicable, local, and electrical
safety codes and standards.
2. Using the appropriate tool, clamp the ring wire terminal to the copper wire. For non-
insulated terminals, use heat shrink tube to cover the non-insulated portion of the
terminal. Choose a terminal ring with the following characteristics:
»Recommended Wire Strip length: 8mm (0.32in)
»Width of the terminal block opening: 10.2mm (0.41in)
3. Remove the front cover by removing the 4 screws at each corner of the charging station.
For more information on how to remove the front cover refer to Chapter 3.1 Adjust
Maximum Current Output on page 10.
4. With the front cover placed to the side, use Philips screwdriver to release terminal screws
of the input cable. Loosen the Strain Relief Fitting for the 6-50 or 14-50 Plug and Remove
the Plug. Remove the Strain Relief connector.
5. Insert the wire end passing through the conduit and insert them into the input wiring hole.
(Use Red wire for L1, Black wire for L2, Green wire for G). Attach the copper wire on the
corresponding terminal block. Use the following wire and torque force when connecting to
input terminal block.
5.1 Optional Hardwire Connection
Terminal
L1, L2, G
Conductor
6-8 AWG
(10AWG for ground)
Screw
M4
Rating
75C,
copper wire
Torque
max 1.8Nm | 16 LBF.IN

18
CAUTION: To reduce the risk of fire, connect only to a circuit
provided with the appropriate amperes minimum branch circuit
overcurrent protection in accordance with the National Electrical
Code, ANSI/NFPA 70, and the Canadian Electrical Code, Part I, C22.1.
6. Once the input wiring and conduit are connected, reassemble the charging station.
Reinstall the charging station font cover using the following torque force to secure the
(4) screws:
Screw Torque
5/32” 13.88 lbf in (1.56Nm)

19
5.2 Replace Output Cable
1. Remove the front cover by removing the 4 screws at each corner of the charging station.
2. Loosen the gland beneath the charger.
3. Loosen strain relief clamp on inside of charger. Use a screwdriver or other tool to break
metal clamp.
4. Use Philips screwdriver to release terminal screws of the output cable.
5. Pull the terminal wires out of the enclosure. Remove cable completely from charger.
6. Insert Output Cable through Output Cable Gland. Route the 4 terminal wires through the
Cable Gland and into the enclosure. Feed the cable through the enclosure such that ½” of
the black rubber jacket is exposed.
7. Place metal strain relief clamp through terminal wires and over exposed rubber jacket.
8. Tighten strain relief clamp by squeezing on the notch with vise grip or other tool. Tighten
until cable is secure.
9. Insert the terminal wires into the corresponding input wiring hole. Terminal wires and
terminals will be labeled. Use Philips screwdriver to tighten each terminal wire to the
terminal block. Torque terminal screws to 16 LBF.IN.
10. Once the input wiring is connected, re-tighten the cable gland.
11. Reinstall the charging station font cover.

20
6. EasyEvPlug Holster and Cable Management System
The EasyEVPlug™ Holster or Tesla EasyEVPlug™ Holster is the new innovative method to
protect the charging plug and manage the cord. It has the following features:
• No need to aim – awless plug even in the dark.
• EV Charging Plug will always be in a convenient location.
• Saves space – special angle for less wall clearance.
• Integrated cable management – holds up to 25 feet of cable.
The EasyEvPlug holster can be installed at any location near the charging station.
1. Hold back of holster against the mounting
surface. Fasten Phillips head screws through
back holes. Use anchors if attaching directly to
drywall.
(x4)
2. Insert charging connector into holster.
3. Wrap cable on top of EasyEvPlug.
Note: Remove rubber cap from charging gun before inserting into holster.
Failure to do so may result in damage to the cap or holster.
This manual suits for next models
7
Table of contents
Other Grizzl-E Batteries Charger manuals

Grizzl-E
Grizzl-E United Chargers GRS-14-24-P User manual

Grizzl-E
Grizzl-E Mini User manual

Grizzl-E
Grizzl-E United Chargers GRS-14-24-P User manual

Grizzl-E
Grizzl-E GR1-6-18 Series Installation and operating instructions

Grizzl-E
Grizzl-E GR1-6-18-R Installation and operating instructions

Grizzl-E
Grizzl-E Extreme Edition Installation and operating instructions

Grizzl-E
Grizzl-E DUO Installation and operating instructions

Grizzl-E
Grizzl-E DUO GCD-14-24-P Installation and operating instructions

Grizzl-E
Grizzl-E United Chargers GRS-6-24-P User manual

Grizzl-E
Grizzl-E Mini GRM-14-24-PB User manual